{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T01:39:30Z","timestamp":1791509970651,"version":"4.3.4"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,1,10]],"date-time":"2023-01-10T00:00:00Z","timestamp":1673308800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,1,10]],"date-time":"2023-01-10T00:00:00Z","timestamp":1673308800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    Dynamic alignment in prosthetic fitting is important because it affects the user\u2019s stability, kinematics, and kinetics such as socket reaction moments. It is performed by tuning the spatial relationship between the transtibial prosthetic socket and the foot following sequential observational gait analysis in the three anatomical planes. However, the order of planes in which the adjustment should be performed is still unclear. To investigate the appropriate sequence of dynamic alignment adjustment, ten participants with transtibial amputation were asked to walk in different alignment conditions (flexion, extension, adduction, abduction; lateral, medial, anterior, and posterior translation of the socket, and plantarflexion, dorsiflexion, inversion, and eversion of the foot) to measure socket reaction moments in the out-of-planes (e.g., the effect of sagittal alignment on the coronal moment). A significant difference was found only among socket posterior translation, socket flexion, and baseline alignment in the coronal moment (\n                    <jats:italic>P<\/jats:italic>\n                    \u2009=\u20090.02). The results of the current and previous studies suggest that moments in the coronal plane are affected by alignment changes in all three planes, whereas moments in the sagittal plane are affected only by sagittal alignment changes. It is suggested that the procedure of alignment adjustments should be finalized in the coronal plane.\n                  <\/jats:p>","DOI":"10.1038\/s41598-023-27438-1","type":"journal-article","created":{"date-parts":[[2023,1,10]],"date-time":"2023-01-10T06:04:55Z","timestamp":1673330695000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["A proper sequence of dynamic alignment in transtibial prosthesis: insight through socket reaction moments"],"prefix":"10.1038","volume":"13","author":[{"given":"Hiroshi","family":"Hashimoto","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiki","family":"Kobayashi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fan","family":"Gao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masataka","family":"Kataoka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,1,10]]},"reference":[{"key":"27438_CR1","first-page":"493","volume-title":"Atlas of Amputations and Limb Deficiencies","author":"WL Childress","year":"2016","unstructured":"Childress, W. L. & Wurdeman, S. S. R. Transtibial amputation: prosthetic management. In Atlas of Amputations and Limb Deficiencies (eds Krajbich, J. I. et al.) 493\u2013508 (American Academy of Orthopaedic Surgeons, 2016)."},{"key":"27438_CR2","first-page":"159","volume":"65","author":"RE Hannah","year":"1984","unstructured":"Hannah, R. E., Morrison, J. B. & Chapman, A. E. Prostheses alignment: Effect on gait of persons with below-knee amputations. Arch. Phys. Med. Rehabil. 65, 159\u2013162 (1984).","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"27438_CR3","first-page":"373","volume":"32","author":"MS Pinzur","year":"1995","unstructured":"Pinzur, M. S. et al. The effect of prosthetic alignment on relative limb loading in persons with trans-tibial amputation: A preliminary report. J. Rehabil. Res. Dev. 32, 373\u2013377 (1995).","journal-title":"J. Rehabil. Res. Dev."},{"key":"27438_CR4","first-page":"120","volume":"32","author":"SA Rossi","year":"1995","unstructured":"Rossi, S. A., Doyle, W. & Skinner, H. B. Gait initiation of persons with below-knee amputation: The characterization and comparison of force profiles. J. Rehabil. Res. Dev. 32, 120\u2013127 (1995).","journal-title":"J. Rehabil. Res. Dev."},{"key":"27438_CR5","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/S0966-6362(02)00008-5","volume":"16","author":"T Schmalz","year":"2002","unstructured":"Schmalz, T., Blumentritt, S. & Jarasch, R. Energy expenditure and biomechanical characteristics of lower limb amputee gait. Gait Posture 16, 255\u2013263 (2002).","journal-title":"Gait Posture"},{"key":"27438_CR6","doi-asserted-by":"publisher","first-page":"17","DOI":"10.3109\/03093640309167973","volume":"27","author":"A Fridman","year":"2003","unstructured":"Fridman, A., Ona, I. & Isakov, E. The influence of prosthetic foot alignment on trans-tibial amputee gait. Prosthet. Orthot. Int. 27, 17\u201322 (2003).","journal-title":"Prosthet. Orthot. Int."},{"key":"27438_CR7","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1080\/03093640600568617","volume":"30","author":"DHK Chow","year":"2006","unstructured":"Chow, D. H. K., Holmes, A. D., Lee, C. K. L. & Sin, S. W. The effect of prosthesis alignment on the symmetry of gait in subjects with unilateral transtibial amputation. Prosthet. Orthot. Int. 30, 114\u2013128 (2006).","journal-title":"Prosthet. Orthot. Int."},{"key":"27438_CR8","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1097\/00008526-200310000-00005","volume":"15","author":"L Frossard","year":"2003","unstructured":"Frossard, L., Beck, J., Dillon, M. & Evans, J. Development and preliminary testing of a device for the direct measurement of forces and moments in the prosthetic limb of transfemoral amputees during activities of daily living. JPO J. Prosthet. Orthot. 15, 135\u2013142 (2003).","journal-title":"JPO J. Prosthet. Orthot."},{"key":"27438_CR9","doi-asserted-by":"publisher","first-page":"2926","DOI":"10.1016\/j.jbiomech.2008.07.018","volume":"41","author":"C Grumillier","year":"2008","unstructured":"Grumillier, C., Martinet, N., Paysant, J., Andr\u00e9, J. M. & Beyaert, C. Compensatory mechanism involving the hip joint of the intact limb during gait in unilateral trans-tibial amputees. J. Biomech. 41, 2926\u20132931 (2008).","journal-title":"J. Biomech."},{"key":"27438_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1097\/JPO.0b013e31827b360c","volume":"25","author":"ES Neumann","year":"2013","unstructured":"Neumann, E. S., Brink, J., Yalamanchili, K. & Lee, J. S. Regression estimates of pressure on transtibial residual limbs using load cell measurements of the forces and moments occurring at the base of the socket. J. Prosthet. Orthot. 25, 1\u201312 (2013).","journal-title":"J. Prosthet. Orthot."},{"key":"27438_CR11","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1097\/JPO.0000000000000113","volume":"29","author":"G Fiedler","year":"2017","unstructured":"Fiedler, G. & Johnson, M. S. Correlation of transtibial prosthetic alignment quality and step-by-step variance of gait. J. Prosthet. Orthot. 29, 19\u201325 (2017).","journal-title":"J. Prosthet. Orthot."},{"key":"27438_CR12","unstructured":"New York University Post-Graduate Medical School Prosthetics and Orthotics. Gait analysis of below-knee amputee. in Lower-Extremity Prosthetics 171\u2013176 (New York University, 1971)."},{"key":"27438_CR13","volume-title":"The Patellar-Tendon Bearing Below-Knee Prosthesis","author":"CW Radcliffe","year":"1961","unstructured":"Radcliffe, C. W. & Foort, J. The Patellar-Tendon Bearing Below-Knee Prosthesis (University of California Press, 1961)."},{"key":"27438_CR14","doi-asserted-by":"publisher","first-page":"381","DOI":"10.3109\/17483107.2011.637284","volume":"7","author":"AJ Ikeda","year":"2012","unstructured":"Ikeda, A. J. et al. \u00c1 priori alignment of transtibial prostheses: A comparison and evaluation of three methods. Disabil. Rehabil. Assist. Technol. 7, 381\u2013388 (2012).","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"27438_CR15","first-page":"40","volume":"18","author":"Y Wu","year":"1981","unstructured":"Wu, Y., Brncick, M. D., Krick, H. J. & Scotchcast, P. V. C. Interim prosthesis for below-knee amputees. Bull. Prosthet. Res. 18, 40\u201350 (1981).","journal-title":"Bull. Prosthet. Res."},{"key":"27438_CR16","doi-asserted-by":"publisher","first-page":"863","DOI":"10.1080\/09638280701240243","volume":"29","author":"K Reisinger","year":"2007","unstructured":"Reisinger, K. & Casanova, H. Comparison of \u00e1 priori alignment techniques for transtibial prostheses in the developing world-pilot study. Disabil. Rehabil. 29, 863\u2013872 (2007).","journal-title":"Disabil. Rehabil."},{"key":"27438_CR17","doi-asserted-by":"publisher","first-page":"393","DOI":"10.3109\/17483100903125860","volume":"4","author":"KD Reisinger","year":"2009","unstructured":"Reisinger, K. D., Casanova, H., Wu, Y. & Moorer, C. Evaluation and comparison of \u00e1 priori alignment techniques for transtibial prostheses in the developing world\u2014field trial in Nicaragua. Disabil. Rehabil. Assist. Technol. 4, 393\u2013405 (2009).","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"27438_CR18","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1016\/0268-0033(94)90008-6","volume":"9","author":"E Isakov","year":"1994","unstructured":"Isakov, E., Mizrahi, J., Susak, Z., Ona, I. & Hakim, N. Influence of prosthesis alignment on the standing balance of below-knee amputees. Clin. Biomech. 9, 258\u2013262 (1994).","journal-title":"Clin. Biomech."},{"key":"27438_CR19","doi-asserted-by":"publisher","first-page":"231","DOI":"10.3109\/03093649909071639","volume":"23","author":"S Blumentritt","year":"1999","unstructured":"Blumentritt, S., Schmalz, T., Jarasch, R. & Schneider, M. Effects of sagittal plane prosthetic alignment on standing trans-tibial amputee knee loads. Prosthet. Orthot. Int. 23, 231\u2013238 (1999).","journal-title":"Prosthet. Orthot. Int."},{"key":"27438_CR20","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1007\/s11832-013-0530-7","volume":"7","author":"R Mooney","year":"2013","unstructured":"Mooney, R. et al. Radiographic parameters improve lower extremity prosthetic alignment. J. Child Orthop. 7, 543\u2013550 (2013).","journal-title":"J. Child Orthop."},{"key":"27438_CR21","first-page":"81","volume-title":"Atlas of Amputations and Limb Deficiencies","author":"J Brinkmann","year":"2016","unstructured":"Brinkmann, J. & Stevens, P. Clinical consideration of observational gait analysis. In Atlas of Amputations and Limb Deficiencies (eds Krajbich, J. et al.) 81\u201395 (American Academy of Orthopaedic Surgeons, 2016)."},{"key":"27438_CR22","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1682\/JRRD.2011.08.0143","volume":"49","author":"DA Boone","year":"2012","unstructured":"Boone, D. A. et al. Perception of socket alignment perturbations in amputees with transtibial prostheses. J. Rehabil. Res. Dev. 49, 843 (2012).","journal-title":"J. Rehabil. Res. Dev."},{"key":"27438_CR23","first-page":"205566831879540","volume":"5","author":"H Hashimoto","year":"2018","unstructured":"Hashimoto, H., Kobayashi, T., Gao, F., Kataoka, M. & Okuda, K. The effect of coronal prosthetic alignment changes on socket reaction moments, spatiotemporal parameters, and perception of alignment during gait in individuals with transtibial amputation. J. Rehabil. Assist. Technol. Eng. 5, 205566831879540 (2018).","journal-title":"J. Rehabil. Assist. Technol. Eng."},{"key":"27438_CR24","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1016\/j.gaitpost.2007.12.073","volume":"28","author":"C Beyaert","year":"2008","unstructured":"Beyaert, C., Grumillier, C., Martinet, N., Paysant, J. & Andr\u00e9, J.-M. Compensatory mechanism involving the knee joint of the intact limb during gait in unilateral below-knee amputees. Gait Posture 28, 278\u2013284 (2008).","journal-title":"Gait Posture"},{"key":"27438_CR25","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0167466","volume":"11","author":"N Jonkergouw","year":"2016","unstructured":"Jonkergouw, N., Prins, M. R., Buis, A. W. P. & van der Wurff, P. The effect of alignment changes on unilateral transtibial amputee\u2019s gait: A systematic review. PLoS ONE 11, e0167466 (2016).","journal-title":"PLoS ONE"},{"key":"27438_CR26","first-page":"2","volume":"23","author":"MS Zahedi","year":"1986","unstructured":"Zahedi, M. S., Spence, W. D., Solomonidis, S. E. & Paul, J. P. Alignment of lower-limb prostheses. J. Rehabil. Res. Dev. 23, 2\u201319 (1986).","journal-title":"J. Rehabil. Res. Dev."},{"key":"27438_CR27","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1016\/j.gaitpost.2012.10.002","volume":"37","author":"DA Boone","year":"2013","unstructured":"Boone, D. A. et al. Influence of malalignment on socket reaction moments during gait in amputees with transtibial prostheses. Gait Posture 37, 620\u2013626 (2013).","journal-title":"Gait Posture"},{"key":"27438_CR28","doi-asserted-by":"publisher","first-page":"512","DOI":"10.1177\/0309364614545421","volume":"39","author":"T Kobayashi","year":"2015","unstructured":"Kobayashi, T., Orendurff, M. S. & Boone, D. A. Dynamic alignment of transtibial prostheses through visualization of socket reaction moments. Prosthet. Orthot. Int. 39, 512\u2013516 (2015).","journal-title":"Prosthet. Orthot. Int."},{"key":"27438_CR29","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/j.gaitpost.2018.06.119","volume":"65","author":"H Hashimoto","year":"2018","unstructured":"Hashimoto, H. et al. The effect of transverse prosthetic alignment changes on socket reaction moments during gait in individuals with transtibial amputation. Gait Posture 65, 8\u201314 (2018).","journal-title":"Gait Posture"},{"key":"27438_CR30","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1177\/0309364615574161","volume":"40","author":"CWJ Chen","year":"2016","unstructured":"Chen, C. W. J. et al. Evaluation of an instrument-assisted dynamic prosthetic alignment technique for individuals with transtibial amputation. Prosthet. Orthot. Int. 40, 475\u2013483 (2016).","journal-title":"Prosthet. Orthot. Int."},{"key":"27438_CR31","first-page":"31","volume":"7","author":"A Staros","year":"1963","unstructured":"Staros, A. Dynamic alignment of artificial legs with the adjustable coupling. Artif. Limbs 7, 31\u201343 (1963).","journal-title":"Artif. Limbs"},{"key":"27438_CR32","doi-asserted-by":"publisher","first-page":"2603","DOI":"10.1016\/j.jbiomech.2012.08.014","volume":"45","author":"T Kobayashi","year":"2012","unstructured":"Kobayashi, T., Orendurff, M. S., Zhang, M. & Boone, D. A. Effect of transtibial prosthesis alignment changes on out-of-plane socket reaction moments during walking in amputees. J. Biomech. 45, 2603\u20132609 (2012).","journal-title":"J. Biomech."},{"key":"27438_CR33","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/j.gaitpost.2022.06.014","volume":"97","author":"H Hashimoto","year":"2022","unstructured":"Hashimoto, H., Kobayashi, T., Kataoka, M. & Okuda, K. Angulation vs translation of transtibial prosthetic socket: Their difference analyzed by socket reaction moments. Gait Posture 97, 137\u2013146 (2022).","journal-title":"Gait Posture"},{"key":"27438_CR34","doi-asserted-by":"publisher","first-page":"2539","DOI":"10.1016\/j.jbiomech.2013.07.012","volume":"46","author":"T Kobayashi","year":"2013","unstructured":"Kobayashi, T., Orendurff, M. S. & Boone, D. A. Effect of alignment changes on socket reaction moments during gait in transfemoral and knee-disarticulation prostheses: Case series. J. Biomech. 46, 2539\u20132545 (2013).","journal-title":"J. Biomech."},{"key":"27438_CR35","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.clinbiomech.2013.11.005","volume":"29","author":"T Kobayashi","year":"2014","unstructured":"Kobayashi, T. et al. Effect of alignment changes on socket reaction moments while walking in transtibial prostheses with energy storage and return feet. Clin. Biomech. 29, 47\u201356 (2014).","journal-title":"Clin. Biomech."},{"key":"27438_CR36","unstructured":"Plug-in Gait Reference Guide. Vicon Motion Systems Limited. https:\/\/docs.vicon.com\/display\/Nexus210\/PDF+downloads+for+Vicon+Nexus?preview=\/98963539\/98964068\/Plug-inGait ReferenceGuide.pdf. 2020 (2020)."},{"key":"27438_CR37","doi-asserted-by":"crossref","unstructured":"Perry, J. & Burnfield, J. M. Knee. in Gait Analysis 85\u2013102 (Slack, 2010).","DOI":"10.1201\/9781003525592-7"},{"key":"27438_CR38","doi-asserted-by":"publisher","first-page":"1315","DOI":"10.1016\/j.jbiomech.2014.02.012","volume":"47","author":"T Kobayashi","year":"2014","unstructured":"Kobayashi, T., Orendurff, M. S., Arabian, A. K., Rosenbaum-Chou, T. G. & Boone, D. A. Effect of prosthetic alignment changes on socket reaction moment impulse during walking in transtibial amputees. J. Biomech. 47, 1315\u20131323 (2014).","journal-title":"J. Biomech."},{"key":"27438_CR39","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1016\/j.gaitpost.2021.08.011","volume":"90","author":"H Hashimoto","year":"2021","unstructured":"Hashimoto, H., Kobayashi, T., Kataoka, M. & Okuda, K. Influence of coronal and sagittal prosthetic foot alignment on socket reaction moments in transtibial prostheses during walking. Gait Posture 90, 252\u2013260 (2021).","journal-title":"Gait Posture"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-27438-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-27438-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-27438-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,11]],"date-time":"2024-10-11T18:50:28Z","timestamp":1728672628000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-27438-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,10]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["27438"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-27438-1","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,10]]},"assertion":[{"value":"22 October 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 January 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 January 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"HH is an employee of Pacific Supply Co. Ltd., the distributor of Europa in Japan. TK was an employee of Orthocare Innovation LLC, the manufacturer of Europa. FG and MT declare no potential conflict of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"458"}}