{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,16]],"date-time":"2026-05-16T15:18:15Z","timestamp":1778944695488,"version":"3.51.4"},"reference-count":53,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,2,21]],"date-time":"2023-02-21T00:00:00Z","timestamp":1676937600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,2,21]],"date-time":"2023-02-21T00:00:00Z","timestamp":1676937600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["21K171530"],"award-info":[{"award-number":["21K171530"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["19K19283"],"award-info":[{"award-number":["19K19283"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["15H05048"],"award-info":[{"award-number":["15H05048"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The purpose of the present study was to fabricate a miniscrew possible for clinical application using Zr<jats:sub>70<\/jats:sub>Ni<jats:sub>16<\/jats:sub>Cu<jats:sub>6<\/jats:sub>Al<jats:sub>8<\/jats:sub>bulk metallic glass (BMG), which has high mechanical strength, low elastic modulus, and high biocompatibility. First, the elastic moduli of Zr-based metallic glass rods made of Zr<jats:sub>55<\/jats:sub>Ni<jats:sub>5<\/jats:sub>Cu<jats:sub>30<\/jats:sub>Al<jats:sub>10<\/jats:sub>, Zr<jats:sub>60<\/jats:sub>Ni<jats:sub>10<\/jats:sub>Cu<jats:sub>20<\/jats:sub>Al<jats:sub>10<\/jats:sub>, Zr<jats:sub>65<\/jats:sub>Ni<jats:sub>10<\/jats:sub>Cu<jats:sub>17.5<\/jats:sub>Al<jats:sub>7.5<\/jats:sub>, Zr<jats:sub>68<\/jats:sub>Ni<jats:sub>12<\/jats:sub>Cu<jats:sub>12<\/jats:sub>Al<jats:sub>8<\/jats:sub>, and Zr<jats:sub>70<\/jats:sub>Ni<jats:sub>16<\/jats:sub>Cu<jats:sub>6<\/jats:sub>Al<jats:sub>8<\/jats:sub>were measured. Zr<jats:sub>70<\/jats:sub>Ni<jats:sub>16<\/jats:sub>Cu<jats:sub>6<\/jats:sub>Al<jats:sub>8<\/jats:sub>had the lowest elastic modulus among them. Then, we fabricated Zr<jats:sub>70<\/jats:sub>Ni<jats:sub>16<\/jats:sub>Cu<jats:sub>6<\/jats:sub>Al<jats:sub>8<\/jats:sub>BMG miniscrews with diameters from 0.9 to 1.3\u00a0mm, conducted a torsion test, and implanted them into the alveolar bone of beagle dogs to compare insertion torque, removal torque, Periotest, new bone formation around the miniscrew, and failure rate compared with 1.3\u00a0mm diameter Ti-6Al-4\u00a0V miniscrew. The Zr<jats:sub>70<\/jats:sub>Ni<jats:sub>16<\/jats:sub>Cu<jats:sub>6<\/jats:sub>Al<jats:sub>8<\/jats:sub>BMG miniscrew exhibited a high torsion torque even if the miniscrew had a small diameter. Zr<jats:sub>70<\/jats:sub>Ni<jats:sub>16<\/jats:sub>Cu<jats:sub>6<\/jats:sub>Al<jats:sub>8<\/jats:sub>BMG miniscrews with a diameter of 1.1\u00a0mm or less had higher stability and lower failure rate than 1.3\u00a0mm diameter Ti-6Al-4\u00a0V miniscrews. Furthermore, the smaller diameter Zr<jats:sub>70<\/jats:sub>Ni<jats:sub>16<\/jats:sub>Cu<jats:sub>6<\/jats:sub>Al<jats:sub>8<\/jats:sub>BMG miniscrew was shown, for the first time, to have a higher success rate and to form more new bone around the miniscrew. These findings suggested the usefulness of our novel small miniscrew made of Zr<jats:sub>70<\/jats:sub>Ni<jats:sub>16<\/jats:sub>Cu<jats:sub>6<\/jats:sub>Al<jats:sub>8<\/jats:sub>BMG for orthodontic anchorage.<\/jats:p>","DOI":"10.1038\/s41598-023-30102-3","type":"journal-article","created":{"date-parts":[[2023,2,21]],"date-time":"2023-02-21T14:01:38Z","timestamp":1676988098000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Mechanical properties and biocompatibility of a novel miniscrew made of Zr70Ni16Cu6Al8 bulk metallic glass for orthodontic anchorage"],"prefix":"10.1038","volume":"13","author":[{"given":"Shutaro","family":"Sasaki","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masahiro","family":"Seiryu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroto","family":"Ida","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shunro","family":"Miyashita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nobuo","family":"Takeshita","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daiki","family":"Irie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshihiko","family":"Yokoyama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teruko","family":"Takano-Yamamoto","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,2,21]]},"reference":[{"key":"30102_CR1","first-page":"35","volume":"31","author":"S Lesz","year":"2008","unstructured":"Lesz, S. & Kwapuli\u0144ski, P. Formation and physical properties of Fe-based bulk metallic glasses with Ni addition. Form. Phys. Prop. Fe-Based Bulk Met. Glas Ni Addit. 31, 35\u201340 (2008).","journal-title":"Form. Phys. Prop. Fe-Based Bulk Met. Glas Ni Addit."},{"key":"30102_CR2","doi-asserted-by":"publisher","first-page":"3489","DOI":"10.1016\/j.msec.2013.04.038","volume":"33","author":"YB Wang","year":"2013","unstructured":"Wang, Y. B., Li, H. F., Cheng, Y., Zheng, Y. F. & Ruan, L. Q. In vitro and in vivo studies on Ti-based bulk metallic glass as potential dental implant material. Mater. Sci. Eng. C 33, 3489\u20133497 (2013).","journal-title":"Mater. Sci. Eng. C"},{"key":"30102_CR3","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1016\/S0921-5093(99)00105-7","volume":"267","author":"A Gebert","year":"1999","unstructured":"Gebert, A. et al. Investigations on the electrochemical behaviour of Zr-based bulk metallic glasses. Mater. Sci. Eng. A 267, 294\u2013300 (1999).","journal-title":"Mater. Sci. Eng. A"},{"key":"30102_CR4","doi-asserted-by":"publisher","first-page":"2950","DOI":"10.1016\/j.corsci.2010.05.007","volume":"52","author":"A Kawashima","year":"2010","unstructured":"Kawashima, A., Yokoyama, Y. & Inoue, A. Zr-based bulk glassy alloy with improved resistance to stress corrosion cracking in sodium chloride solutions. Corros. Sci. 52, 2950\u20132957 (2010).","journal-title":"Corros. Sci."},{"key":"30102_CR5","doi-asserted-by":"publisher","first-page":"6097","DOI":"10.1016\/j.actamat.2008.08.026","volume":"56","author":"Y Yokoyama","year":"2008","unstructured":"Yokoyama, Y., Yamasaki, T., Liaw, P. K. & Inoue, A. Study of the structural relaxation-induced embrittlement of hypoeutectic Zr\u2013Cu\u2013Al ternary bulk glassy alloys. Acta Mater. 56, 6097\u20136108 (2008).","journal-title":"Acta Mater."},{"key":"30102_CR6","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1080\/09500830902873575","volume":"89","author":"Y Yokoyama","year":"2009","unstructured":"Yokoyama, Y., Fujita, K., Yavari, A. R. & Inoue, A. Malleable hypoeutectic Zr\u2013Ni\u2013Cu\u2013Al bulk glassy alloys with tensile plastic elongation at room temperature. Philos. Mag. Lett. 89, 322\u2013334 (2009).","journal-title":"Philos. Mag. Lett."},{"key":"30102_CR7","doi-asserted-by":"publisher","first-page":"1468","DOI":"10.1007\/s11661-011-0631-1","volume":"42","author":"Y Yokoyama","year":"2011","unstructured":"Yokoyama, Y. et al. Tough hypoeutectic Zr-based bulk metallic glasses. Met. Mater. Trans. Phys. Met. Mater. Sci. 42, 1468\u20131475 (2011).","journal-title":"Met. Mater. Trans. Phys. Met. Mater. Sci."},{"key":"30102_CR8","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1007\/BF02642403","volume":"13","author":"G Welsch","year":"1982","unstructured":"Welsch, G. & Bunk, W. Deformation modes of the \u03b1-phase of Ti-6Al-4V as a function of oxygen concentration and aging temperature. Met. Mater Trans. A 13, 889\u2013899 (1982).","journal-title":"Met. Mater Trans. A"},{"key":"30102_CR9","volume-title":"Titanium and Titanium Alloys: Scientific and Technological Aspects","author":"AW Bowen","year":"1982","unstructured":"Bowen, A. W. & Stubbington, C. A. Titanium and Titanium Alloys: Scientific and Technological Aspects (Plenum, 1982)."},{"key":"30102_CR10","doi-asserted-by":"publisher","first-page":"1413","DOI":"10.1007\/BF02661812","volume":"9","author":"GR Yoder","year":"1978","unstructured":"Yoder, G. R., Cooley, L. A. & Crooker, T. W. Fatigue crack propagation resistance of beta-annealed Ti-6Al-4V alloys of differing interstitial oxygen contents. Met. Mater. Trans. A 9, 1413\u20131420 (1978).","journal-title":"Met. Mater. Trans. A"},{"key":"30102_CR11","volume-title":"Smithells Metals Reference Book","author":"EA Brandes","year":"1998","unstructured":"Brandes, E. A. Smithells Metals Reference Book (Butterworths, 1998)."},{"key":"30102_CR12","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-80587-5","volume-title":"Titan und Titanlegierungen","author":"U Zwicker","year":"1974","unstructured":"Zwicker, U. Titan und Titanlegierungen (Springer, 1974)."},{"key":"30102_CR13","doi-asserted-by":"publisher","DOI":"10.1017\/CBO9781139878326","volume-title":"Cellular Solids: Structure and Properties","author":"LJ Gibson","year":"1997","unstructured":"Gibson, L. J. & Ashby, M. F. Cellular Solids: Structure and Properties (Cambridge University Press, 1997)."},{"key":"30102_CR14","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/0921-5093(90)90097-M","volume":"128","author":"Y Lee","year":"1990","unstructured":"Lee, Y. & Welsch, G. Young\u2019s modulus and damping of Ti-6Al-4V alloy as a function of heat treatment and oxygen concentration. Mater. Sci. Eng. A 128, 77\u201389 (1990).","journal-title":"Mater. Sci. Eng. A"},{"key":"30102_CR15","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1016\/j.actbio.2018.05.020","volume":"74","author":"H Ida","year":"2018","unstructured":"Ida, H. et al. Biosafety, stability, and osteogenic activity of novel implants made of Zr70Ni16Cu6Al8 bulk metallic glass for biomedical application. Acta Biomater. 74, 505\u2013517 (2018).","journal-title":"Acta Biomater."},{"key":"30102_CR16","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1007\/s11837-008-0031-1","volume":"60","author":"CN Elias","year":"2008","unstructured":"Elias, C. N., Lima, J. H. C., Valiev, R. & Meyers, M. A. Biomedical applications of titanium and its alloys. JOM 60, 46\u201349 (2008).","journal-title":"JOM"},{"key":"30102_CR17","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1080\/17453670610045902","volume":"77","author":"M Sundfeldt","year":"2006","unstructured":"Sundfeldt, M., Carlsson, L. V., Johansson, C. B., Thomsen, P. & Gretzer, C. Aseptic loosening, not only a question of wear: A review of different theories. Acta Orthop. 77, 177\u2013197 (2006).","journal-title":"Acta Orthop."},{"key":"30102_CR18","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.msec.2014.01.048","volume":"38","author":"B Piotrowski","year":"2014","unstructured":"Piotrowski, B. et al. Interaction of bone\u2013dental implant with new ultra low modulus alloy using a numerical approach. Mater. Sci. Eng. C 38, 151\u2013160 (2014).","journal-title":"Mater. Sci. Eng. C"},{"key":"30102_CR19","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.jbiomech.2017.08.017","volume":"63","author":"G Yamako","year":"2017","unstructured":"Yamako, G. et al. Improving stress shielding following total hip arthroplasty by using a femoral stem made of \u03b2 type Ti-33.6Nb-4Sn with a Young\u2019s modulus gradation. J. Biomech. 63, 135\u2013143 (2017).","journal-title":"J. Biomech."},{"key":"30102_CR20","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1111\/ocr.12449","volume":"24","author":"M Migliorati","year":"2021","unstructured":"Migliorati, M., Drago, S., Amorfini, L., Nucera, R. & Silvestrini-Biavati, A. Maximum insertion torque loss after miniscrew placement in orthodontic patients: A randomized controlled trial. Orthod. Craniofac. Res. 24, 386\u2013395 (2021).","journal-title":"Orthod. Craniofac. Res."},{"key":"30102_CR21","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1111\/j.1600-0501.2007.01418.x","volume":"19","author":"Y-H Chen","year":"2008","unstructured":"Chen, Y.-H. et al. Root contact during insertion of miniscrews for orthodontic anchorage increases the failure rate: An animal study. Clin. Oral Implants Res. 19, 99\u2013106 (2008).","journal-title":"Clin. Oral Implants Res."},{"key":"30102_CR22","doi-asserted-by":"publisher","first-page":"130","DOI":"10.2319\/011509-535.1","volume":"80","author":"U-H Choa","year":"2010","unstructured":"Choa, U.-H., Yub, W. & Kyung, H.-M. Root contact during drilling for microimplant placement. Angle Orthod. 80, 130\u2013136 (2010).","journal-title":"Angle Orthod."},{"key":"30102_CR23","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1016\/j.ajodo.2008.11.032","volume":"139","author":"Y-C Hwang","year":"2011","unstructured":"Hwang, Y.-C. & Hwang, H.-S. Surgical repair of root perforation caused by an orthodontic miniscrew implant. Am. J. Orthod. Dentofac. Orthop. 139, 407\u2013411 (2011).","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"30102_CR24","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1016\/j.ajodo.2010.11.017","volume":"139","author":"EY Suzuki","year":"2011","unstructured":"Suzuki, E. Y. & Suzuki, B. Placement and removal torque values of orthodontic miniscrew implants. Am. J. Orthod. Dentofac. Orthop. 139, 669\u2013678 (2011).","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"30102_CR25","first-page":"326","volume":"41","author":"TH Jolley","year":"2007","unstructured":"Jolley, T. H. & Chung, C. H. Peak torque values at fracture of orthodontic miniscrews. J. Clin. Orthod. 41, 326\u2013328 (2007).","journal-title":"J. Clin. Orthod."},{"key":"30102_CR26","doi-asserted-by":"publisher","first-page":"S68","DOI":"10.1016\/j.ajodo.2006.06.017","volume":"131","author":"S Kuroda","year":"2007","unstructured":"Kuroda, S. et al. Root proximity is a major factor for screw failure in orthodontic anchorage. Am. J. Orthod. Dentofac. Orthop. 131, S68\u2013S73 (2007).","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"30102_CR27","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1111\/ocr.12003","volume":"16","author":"H Watanabe","year":"2013","unstructured":"Watanabe, H. et al. Orthodontic miniscrew failure rate and root proximity, insertion angle, bone contact length, and bone density. Orthod. Craniofac. Res. 16, 44\u201355 (2013).","journal-title":"Orthod. Craniofac. Res."},{"key":"30102_CR28","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1016\/j.ajodo.2007.08.031","volume":"136","author":"RC Santiago","year":"2009","unstructured":"Santiago, R. C., de Paula, F. O., Fraga, M. R., Picorelli Assis, N. M. S. & Vitral, R. W. F. Correlation between miniscrew stability and bone mineral density in orthodontic patients. Am. J. Orthod. Dentofac. Orthop. 136, 243\u2013250 (2009).","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"30102_CR29","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.ajodo.2013.03.021","volume":"144","author":"M Suzuki","year":"2013","unstructured":"Suzuki, M. et al. Evaluation of optimal length and insertion torque for miniscrews. Am. J. Orthod. Dentofac. Orthop. 144, 251\u2013259 (2013).","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"30102_CR30","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.ajodo.2004.11.032","volume":"130","author":"H-S Park","year":"2006","unstructured":"Park, H.-S., Jeong, S.-H. & Kwon, O.-W. Factors affecting the clinical success of screw implants used as orthodontic anchorage. Am. J. Orthod. Dentofac. Orthop. 130, 18\u201325 (2006).","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"30102_CR31","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1111\/j.1600-0501.2005.01149.x","volume":"16","author":"A B\u00fcchter","year":"2005","unstructured":"B\u00fcchter, A. et al. Load-related implant reaction of mini-implants used for orthodontic anchorage. Clin. Oral Implants Res. 16, 473\u2013479 (2005).","journal-title":"Clin. Oral Implants Res."},{"key":"30102_CR32","doi-asserted-by":"publisher","first-page":"396","DOI":"10.1093\/ejo\/cjq151","volume":"33","author":"B Wilmes","year":"2011","unstructured":"Wilmes, B., Panayotidis, A. & Drescher, D. Fracture resistance of orthodontic mini-implants: A biomechanical in vitro study. Eur. J. Orthod. 33, 396\u2013401 (2011).","journal-title":"Eur. J. Orthod."},{"key":"30102_CR33","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1093\/ejo\/cjq067","volume":"33","author":"T Muguruma","year":"2011","unstructured":"Muguruma, T. et al. Relationship between the metallurgical structure of experimental titanium miniscrew implants and their torsional properties. Eur. J. Orthod. 33, 293\u2013297 (2011).","journal-title":"Eur. J. Orthod."},{"issue":"333","key":"30102_CR34","first-page":"e1","volume":"134","author":"M Iijima","year":"2008","unstructured":"Iijima, M. et al. Torsional properties and microstructures of miniscrew implants. Am. J. Orthod. Dentofac. Orthop. 134(333), e1-333.e6 (2008).","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"30102_CR35","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1111\/j.1600-0501.2005.01211.x","volume":"17","author":"M Motoyoshi","year":"2006","unstructured":"Motoyoshi, M., Hirabayashi, M., Uemura, M. & Shimizu, N. Recommended placement torque when tightening an orthodontic mini-implant. Clin. Oral Implants Res. 17, 109\u2013114 (2006).","journal-title":"Clin. Oral Implants Res."},{"key":"30102_CR36","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1016\/S0272-6963(98)00023-0","volume":"16","author":"J Meredith","year":"1998","unstructured":"Meredith, J. Building operations management theory through case and field research. JOM 16, 441\u2013454 (1998).","journal-title":"JOM"},{"key":"30102_CR37","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1093\/ejo\/cjm062","volume":"29","author":"LG Favero","year":"2007","unstructured":"Favero, L. G., Pisoni, A. & Paganelli, C. Removal torque of osseointegrated mini-implants: An in vivo evaluation. Eur. J. Orthod. 29, 443\u2013448 (2007).","journal-title":"Eur. J. Orthod."},{"key":"30102_CR38","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/S0901-5027(05)80837-9","volume":"26","author":"C-J Ivanoff","year":"1997","unstructured":"Ivanoff, C.-J., Sennerby, L., Johansson, C., Rangert, B. & Lekholm, U. Influence of implant diameters on the integration of screw implants: An experimental study in rabbits. Int. J. Oral Maxillofac. Surg. 26, 141\u2013148 (1997).","journal-title":"Int. J. Oral Maxillofac. Surg."},{"key":"30102_CR39","first-page":"390","volume":"5","author":"J Oliv\u00e9","year":"1990","unstructured":"Oliv\u00e9, J. & Aparicio, C. Periotest method as a measure of osseointegrated oral implant stability. Int. J. Oral Maxillofac. Implants 5, 390\u2013400 (1990).","journal-title":"Int. J. Oral Maxillofac. Implants"},{"key":"30102_CR40","doi-asserted-by":"publisher","first-page":"3532","DOI":"10.1016\/j.actbio.2012.05.017","volume":"8","author":"N Harmankaya","year":"2012","unstructured":"Harmankaya, N., Igawa, K., Stenlund, P., Palmquist, A. & Tengvall, P. Healing of complement activating Ti implants compared with non-activating Ti in rat tibia. Acta Biomater. 8, 3532\u20133540 (2012).","journal-title":"Acta Biomater."},{"key":"30102_CR41","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1111\/j.1600-0536.1993.tb03318.x","volume":"28","author":"DA Basketter","year":"1993","unstructured":"Basketter, D. A., Briatico-Vangosa, G., Kaestner, W., Lally, C. & Bontinck, W. J. Nickel, cobalt and chromium in consumer products: A role in allergic contact dermatitis? Contact Derm. 28, 15\u201325 (1993).","journal-title":"Contact Derm."},{"key":"30102_CR42","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1111\/j.1600-0536.1993.tb03427.x","volume":"28","author":"DJ Gawkrodger","year":"1993","unstructured":"Gawkrodger, D. J. Nickel sensitivity and the implantation of orthopaedic prostheses. Contact Derm. 28, 257\u2013259 (1993).","journal-title":"Contact Derm."},{"key":"30102_CR43","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1111\/j.1600-0536.1994.tb01997.x","volume":"31","author":"P Haudrechy","year":"1994","unstructured":"Haudrechy, P., Foussereau, J., Mantout, B. & Baroux, B. Nickel release from nickel-plated metals and stainless steels. Contact Derm. 31, 249\u2013255 (1994).","journal-title":"Contact Derm."},{"key":"30102_CR44","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1111\/j.1600-0536.1994.tb02023.x","volume":"31","author":"L Kanerva","year":"1994","unstructured":"Kanerva, L. et al. Nickel release from metals, and a case of allergic contact dermatitis from stainless steel. Contact Derm. 31, 299\u2013303 (1994).","journal-title":"Contact Derm."},{"key":"30102_CR45","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1111\/j.1365-2133.2010.10016.x","volume":"164","author":"M Kinbara","year":"2011","unstructured":"Kinbara, M. et al. Allergy-inducing nickel concentration is lowered by lipopolysaccharide at both the sensitization and elicitation steps in a murine model. Br. J. Dermatol. 164, 356\u2013362 (2011).","journal-title":"Br. J. Dermatol."},{"key":"30102_CR46","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/0048-9697(90)90055-Y","volume":"95","author":"C Minoia","year":"1990","unstructured":"Minoia, C. et al. Trace element reference values in tissues from inhabitants of the European community: I\u2014A study of 46 elements in urine, blood and serum of Italian subjects. Sci. Total Environ. 95, 89\u2013105 (1990).","journal-title":"Sci. Total Environ."},{"key":"30102_CR47","doi-asserted-by":"publisher","first-page":"fs7","DOI":"10.1126\/scisignal.aab1125","volume":"8","author":"K Naegle","year":"2015","unstructured":"Naegle, K., Gough, N. R. & Yaffe, M. B. Criteria for biological reproducibility: What does \u2018n\u2019 mean? Sci. Signal. 8, fs7 (2015).","journal-title":"Sci. Signal."},{"key":"30102_CR48","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1177\/154405910308200510","volume":"82","author":"T Deguchi","year":"2003","unstructured":"Deguchi, T. et al. The use of small titanium screws for orthodontic anchorage. J. Dent Res. 82, 377\u2013381 (2003).","journal-title":"J. Dent Res."},{"key":"30102_CR49","doi-asserted-by":"publisher","first-page":"889","DOI":"10.1016\/j.ajodo.2006.12.013","volume":"133","author":"T Deguchi","year":"2008","unstructured":"Deguchi, T. et al. Histomorphometric evaluation of alveolar bone turnover between the maxilla and the mandible during experimental tooth movement in dogs. Am. J. Orthod. Dentofac. Orthop. 133, 889\u2013897 (2008).","journal-title":"Am. J. Orthod. Dentofac. Orthop."},{"key":"30102_CR50","doi-asserted-by":"publisher","first-page":"2316","DOI":"10.2320\/matertrans.43.2316","volume":"43","author":"Y Yokoyama","year":"2002","unstructured":"Yokoyama, Y., Inoue, K. & Fukaura, K. Pseudo float melting state in ladle arc-melt-type furnace for preparing crystalline inclusion-free bulk amorphous alloy. Mater. Trans. 43, 2316\u20132319 (2002).","journal-title":"Mater. Trans."},{"key":"30102_CR51","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1016\/j.jmatprotec.2004.04.154","volume":"153\u2013154","author":"Z Pater","year":"2004","unstructured":"Pater, Z., Gontarz, A. & Wero\u00f1ski, W. New method of thread rolling. J. Mater. Process Technol. 153\u2013154, 722\u2013728 (2004).","journal-title":"J. Mater. Process Technol."},{"key":"30102_CR52","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.ajodo.2011.07.020","volume":"141","author":"S \u00c7ehreli","year":"2012","unstructured":"\u00c7ehreli, S. & Arman-\u00d6z\u00e7\u0131rp\u0131c\u0131, A. Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants. Am. J. Orthod. Dentofac. Orthop 141, 187\u2013195 (2012).","journal-title":"Am. J. Orthod. Dentofac. Orthop"},{"key":"30102_CR53","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1002\/jbm.b.10531","volume":"64","author":"M Assad","year":"2003","unstructured":"Assad, M. et al. Porous titanium-nickel for intervertebral fusion in a sheep model: Part 2: Surface analysis and nickel release assessment. J. Biomed. Mater. Res. Part B Appl. Biomater. 64, 121\u2013129 (2003).","journal-title":"J. Biomed. Mater. Res. Part B Appl. Biomater."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30102-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30102-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30102-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,7]],"date-time":"2023-12-07T09:21:16Z","timestamp":1701940876000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30102-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2,21]]},"references-count":53,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["30102"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-30102-3","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,2,21]]},"assertion":[{"value":"14 November 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 February 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 February 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"3038"}}