{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T12:30:56Z","timestamp":1781526656619,"version":"3.54.1"},"reference-count":48,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,3,1]],"date-time":"2023-03-01T00:00:00Z","timestamp":1677628800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,3,1]],"date-time":"2023-03-01T00:00:00Z","timestamp":1677628800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100007308","name":"Arthrex GmbH","doi-asserted-by":"publisher","award":["EMEA19052"],"award-info":[{"award-number":["EMEA19052"]}],"id":[{"id":"10.13039\/100007308","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The aim of this biomechanical investigation was to evaluate a repair technique for type IV FDP tendon avulsions using a suture anchor, addressing the bony and the tendinous aspect of this injury simultaneously. In 45 distal phalanges from human anatomical specimens the injury was simulated and repairs were performed with a suture anchor using an innovative technique, interosseous sutures and a combination of screws and an interosseous suture. Repetitive loading for 500 cycles simulated postoperative mobilization. Repairs were loaded to failure thereafter. Elongation of the tendon-suture complex, gap formation at the bone-bone contact line and at the bone-tendon insertion line, load at first noteworthy displacement (2\u00a0mm), load at failure and the mechanism of failure were assessed. The suture anchor technique was superior biomechanically considering load at failure (mean: 72.8 N), bony gap formation (mean: 0.1\u00a0mm) as well as tendinous gap formation (mean: 0.7\u00a0mm), implying a preferable stability of the repair. Overall, this study demonstrates good ex vivo mechanical stability for a proposed suture anchor repair technique for type IV FDP tendon avulsion injuries, which might enable early postoperative mobilization in patients. The technique's subcutaneous implant placement and low implant load are expected to reduce potential complications observed in other commonly used repair techniques. This approach warrants further evaluation in vivo.\u00a0<\/jats:p>","DOI":"10.1038\/s41598-023-30373-w","type":"journal-article","created":{"date-parts":[[2023,3,1]],"date-time":"2023-03-01T15:03:56Z","timestamp":1677683036000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A suture anchor-based repair technique for type IV jersey finger injuries: a biomechanical investigation"],"prefix":"10.1038","volume":"13","author":[{"given":"Gabriel","family":"Hal\u00e1t","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lukas Leopold","family":"Negrin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paul Lennart","family":"Hoppe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ewald","family":"Unger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Koch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lena","family":"Hirtler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Hajdu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,3,1]]},"reference":[{"key":"30373_CR1","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/S0363-5023(77)80012-9","volume":"2","author":"JP Leddy","year":"1977","unstructured":"Leddy, J. P. & Packer, J. W. Avulsion of the profundus tendon insertion in athletes. J. Hand Surg. Am. 2, 66\u201369 (1977).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR2","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/S0749-0712(21)01334-2","volume":"1","author":"JP Leddy","year":"1985","unstructured":"Leddy, J. P. Avulsions of the flexor digitorum profundus. Hand Clin. 1, 77\u201383 (1985).","journal-title":"Hand Clin."},{"key":"30373_CR3","unstructured":"Robins, P. R. Avulsion of the insertion of the flexor digitorum profundus tendon associated with fracture of the distal phalanx. In A. A. O. S. Symposium on Tendon Surgery in the Hand 151\u2013156 (1975)."},{"key":"30373_CR4","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1054\/jhsb.2001.0619","volume":"26","author":"MM Al-Qattan","year":"2001","unstructured":"Al-Qattan, M. M. Type 5 avulsion of the insertion of the flexor digitorum profundus tendon. J. Hand Surg. Br. 26, 427\u2013431 (2001).","journal-title":"J. Hand Surg. Br."},{"key":"30373_CR5","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/S0749-0712(21)00577-1","volume":"16","author":"BD Stamos","year":"2000","unstructured":"Stamos, B. D. & Leddy, J. P. Closed flexor tendon disruption in athletes. Hand Clin. 16, 359\u2013365 (2000).","journal-title":"Hand Clin."},{"key":"30373_CR6","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1016\/S0363-5023(81)80141-4","volume":"6","author":"JH Smith Jr","year":"1981","unstructured":"Smith, J. H. Jr. Avulsion of a profundus tendon with simultaneous intraarticular fracture of the distal phalanx\u2013case report. J. Hand Surg. Am. 6, 600\u2013601 (1981).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR7","doi-asserted-by":"publisher","first-page":"366","DOI":"10.1177\/036354658701500413","volume":"15","author":"MJ Buscemi","year":"1987","unstructured":"Buscemi, M. J. & Page, B. J. Flexor digitorum profundus avulsions with associated distal phalanx fractures. A report of four cases and review of the literature. Am. J. Sports Med. 15, 366\u2013370 (1987).","journal-title":"Am. J. Sports Med."},{"key":"30373_CR8","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1016\/0363-5023(90)90146-I","volume":"15","author":"WA Eglseder","year":"1990","unstructured":"Eglseder, W. A. & Russell, J. M. Type IV flexor digitorum profundus avulsion. J. Hand Surg. Am. 15, 735\u2013739 (1990).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR9","first-page":"265","volume":"1992","author":"KJ Ehlert","year":"1992","unstructured":"Ehlert, K. J., Gould, J. S. & Black, K. P. A simultaneous distal phalanx avulsion fracture with profundus tendon avulsion. A case report and review of the literature. Clin. Orthop. Relat. Res. 1992, 265\u2013269 (1992).","journal-title":"Clin. Orthop. Relat. Res."},{"key":"30373_CR10","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1016\/S0266-7681(03)00100-1","volume":"28","author":"N Kang","year":"2003","unstructured":"Kang, N., Pratt, A. & Burr, N. Miniplate fixation for avulsion injuries of the flexor digitorum profundus insertion. J. Hand Surg. Br. 28, 363\u2013368 (2003).","journal-title":"J. Hand Surg. Br."},{"key":"30373_CR11","doi-asserted-by":"publisher","first-page":"227","DOI":"10.1016\/S0363-5023(86)80056-9","volume":"11","author":"V Langa","year":"1986","unstructured":"Langa, V. & Posner, M. A. Unusual rupture of a flexor profundus tendon. J. Hand Surg. Am. 11, 227\u2013229 (1986).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR12","doi-asserted-by":"publisher","first-page":"504","DOI":"10.1007\/BF00387588","volume":"116","author":"H Takami","year":"1997","unstructured":"Takami, H., Takahashi, S., Ando, M. & Masuda, A. Flexor digitorum profundus avulsion with associated fracture of the distal phalanx. Arch. Orthop. Trauma Surg. 116, 504\u2013506 (1997).","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"30373_CR13","doi-asserted-by":"publisher","first-page":"902","DOI":"10.1016\/0363-5023(92)90465-2","volume":"17","author":"TE Trumble","year":"1992","unstructured":"Trumble, T. E., Vedder, N. B. & Benirschke, S. K. Misleading fractures after profundus tendon avulsions: A report of six cases. J. Hand Surg. Am. 17, 902\u2013906 (1992).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR14","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1007\/s11552-009-9199-2","volume":"4","author":"SL Henry","year":"2009","unstructured":"Henry, S. L., Katz, M. A. & Green, D. P. Type IV FDP avulsion: Lessons learned clinically and through review of the literature. Hand (N. Y.) 4, 357\u2013361 (2009).","journal-title":"Hand (N. Y.)"},{"key":"30373_CR15","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/S0072-968X(78)80023-0","volume":"10","author":"H Becker","year":"1978","unstructured":"Becker, H. Primary repair of flexor tendons in the hand without immobilisation-preliminary report. Hand 10, 37\u201347 (1978).","journal-title":"Hand"},{"key":"30373_CR16","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1016\/S0363-5023(79)80043-X","volume":"4","author":"H Becker","year":"1979","unstructured":"Becker, H., Orak, F. & Duponselle, E. Early active motion following a beveled technique of flexor tendon repair: Report on fifty cases. J. Hand Surg. Am. 4, 454\u2013460 (1979).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR17","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1016\/0266-7681_89_90153-8","volume":"14","author":"KW Cullen","year":"1989","unstructured":"Cullen, K. W., Tolhurst, P., Lang, D. & Page, R. E. Flexor tendon repair in zone 2 followed by controlled active mobilisation. J. Hand Surg. Br. 14, 392\u2013395 (1989).","journal-title":"J. Hand Surg. Br."},{"key":"30373_CR18","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/S0266-7681(05)80062-2","volume":"20","author":"HD Skoff","year":"1995","unstructured":"Skoff, H. D., Hecker, A. T., Hayes, W. C., Sebell-Sklar, R. & Straughn, N. Bone suture anchors in hand surgery. J. Hand Surg. Br. 20, 245\u2013248 (1995).","journal-title":"J. Hand Surg. Br."},{"key":"30373_CR19","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1016\/S0749-0712(21)00547-3","volume":"2","author":"EG Zook","year":"1986","unstructured":"Zook, E. G. Complications of the perionychium. Hand Clin. 2, 407\u2013427 (1986).","journal-title":"Hand Clin."},{"key":"30373_CR20","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/S0749-0712(21)01243-9","volume":"6","author":"EG Zook","year":"1990","unstructured":"Zook, E. G. & Russell, R. C. Reconstruction of a functional and esthetic nail. Hand Clin. 6, 59\u201368 (1990).","journal-title":"Hand Clin."},{"key":"30373_CR21","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1177\/1753193408090118","volume":"33","author":"N Kang","year":"2008","unstructured":"Kang, N., Marsh, D. & Dewar, D. The morbidity of the button-over-nail technique for zone 1 flexor tendon repairs. Should we still be using this technique?. J. Hand Surg. Eur. 33, 566\u2013570 (2008).","journal-title":"J. Hand Surg. Eur."},{"key":"30373_CR22","doi-asserted-by":"publisher","first-page":"973","DOI":"10.1177\/1753193413475748","volume":"38","author":"S Huq","year":"2013","unstructured":"Huq, S., George, S. & Boyce, D. E. The outcomes of zone 1 flexor tendon injuries treated using micro bone suture anchors. J. Hand Surg. Eur. 38, 973\u2013978 (2013).","journal-title":"J. Hand Surg. Eur."},{"key":"30373_CR23","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1016\/j.bjps.2013.04.026","volume":"66","author":"S Huq","year":"2013","unstructured":"Huq, S., George, S. & Boyce, D. E. Zone 1 flexor tendon injuries: A review of the current treatment options for acute injuries. J. Plast. Reconstr. Aesthet. Surg. 66, 1023\u20131031 (2013).","journal-title":"J. Plast. Reconstr. Aesthet. Surg."},{"key":"30373_CR24","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1097\/BTH.0b013e3181abc9c","volume":"13","author":"M Kapickis","year":"2009","unstructured":"Kapickis, M. New, \u201cloop\u201d suture for FDP zone I injuries. Tech. Hand Up Extrem. Surg. 13, 141\u2013144 (2009).","journal-title":"Tech. Hand Up Extrem. Surg."},{"key":"30373_CR25","doi-asserted-by":"publisher","first-page":"46","DOI":"10.1097\/00000637-199901000-00008","volume":"42","author":"RO Schultz","year":"1999","unstructured":"Schultz, R. O., Drake, D. B. & Morgan, R. F. A new technique for the treatment of flexor digitorum profundus tendon avulsion. Ann. Plast. Surg. 42, 46\u201348 (1999).","journal-title":"Ann. Plast. Surg."},{"key":"30373_CR26","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1016\/S0266-7681(96)80146-X","volume":"21","author":"MK Sood","year":"1996","unstructured":"Sood, M. K. & Elliot, D. A new technique of attachment of flexor tendons to the distal phalanx without a button tie-over. J. Hand Surg. Br. 21, 629\u2013632 (1996).","journal-title":"J. Hand Surg. Br."},{"key":"30373_CR27","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1097\/PRS.0b013e3181956572","volume":"123","author":"TC Teo","year":"2009","unstructured":"Teo, T. C., Dionyssiou, D., Armenio, A., Ng, D. & Skillman, J. Anatomical repair of zone 1 flexor tendon injuries. Plast. Reconstr. Surg. 123, 617\u2013622 (2009).","journal-title":"Plast. Reconstr. Surg."},{"key":"30373_CR28","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1177\/1753193408096764","volume":"34","author":"AK Tripathi","year":"2009","unstructured":"Tripathi, A. K., Mee, S. N., Martin, D. L. & Katsarma, E. The, \u201ctransverse intraosseous loop technique\u201d (TILT) to re-insert flexor tendons in zone 1. J. Hand Surg. Eur. 34, 85\u201389 (2009).","journal-title":"J. Hand Surg. Eur."},{"issue":"986","key":"30373_CR29","first-page":"e981","volume":"44","author":"S Bond","year":"2019","unstructured":"Bond, S., Rust, P. & Boland, M. The accommodation of bone anchors within the distal phalanx for repair of flexor digitorum profundus avulsions. J. Hand Surg. Am. 44(986), e981-986.e986 (2019).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR30","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1016\/j.jhsa.2013.11.023","volume":"39","author":"G Halat","year":"2014","unstructured":"Halat, G. et al. Biomechanical characteristics of suture anchor implants for flexor digitorum profundus repair. J. Hand Surg. Am. 39, 256\u2013261 (2014).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR31","doi-asserted-by":"publisher","first-page":"9906","DOI":"10.1038\/s41598-018-28250-y","volume":"8","author":"G Halat","year":"2018","unstructured":"Halat, G. et al. Introduction of a new repair technique in bony avulsion of the FDP tendon: A biomechanical study. Sci. Rep. 8, 9906 (2018).","journal-title":"Sci. Rep."},{"key":"30373_CR32","doi-asserted-by":"publisher","first-page":"246","DOI":"10.1016\/j.jhsa.2005.10.020","volume":"31","author":"WV McCallister","year":"2006","unstructured":"McCallister, W. V., Ambrose, H. C., Katolik, L. I. & Trumble, T. E. Comparison of pullout button versus suture anchor for zone I flexor tendon repair. J. Hand Surg. Am. 31, 246\u2013251 (2006).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR33","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.hansur.2017.06.002","volume":"36","author":"C Tempelaere","year":"2017","unstructured":"Tempelaere, C., Brun, M., Doursounian, L. & Feron, J. M. Traumatic avulsion of the flexor digitorum profundus tendon. Jersey finger, a 29 cases report. Hand Surg. Rehabil. 36, 368\u2013372 (2017).","journal-title":"Hand Surg. Rehabil."},{"key":"30373_CR34","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1053\/jhsu.2001.24135","volume":"26","author":"M Brustein","year":"2001","unstructured":"Brustein, M., Pellegrini, J., Choueka, J., Heminger, H. & Mass, D. Bone suture anchors versus the pullout button for repair of distal profundus tendon injuries: A comparison of strength in human cadaveric hands. J. Hand Surg. Am. 26, 489\u2013496 (2001).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR35","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/S0072-968X(78)80025-4","volume":"10","author":"PR Manske","year":"1978","unstructured":"Manske, P. R. & Lesker, P. A. Avulsion of the ring finger flexor digitorum profundus tendon: An experimental study. Hand 10, 52\u201355 (1978).","journal-title":"Hand"},{"key":"30373_CR36","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1016\/J.JHSB.2005.12.004","volume":"31","author":"FB Schreuder","year":"2006","unstructured":"Schreuder, F. B., Scougall, P. J., Puchert, E., Vizesi, F. & Walsh, W. R. The effect of mitek anchor insertion angle to attachment of FDP avulsion injuries. J. Hand Surg. Br. 31, 292\u2013295 (2006).","journal-title":"J. Hand Surg. Br."},{"key":"30373_CR37","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1016\/S0363-5023(05)80109-1","volume":"20","author":"H Tanaka","year":"1995","unstructured":"Tanaka, H., Manske, P. R., Pruitt, D. L. & Larson, B. J. Effect of cyclic tension on lacerated flexor tendons in vitro. J. Hand Surg. Am. 20, 467\u2013473 (1995).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR38","first-page":"15","volume":"2020","author":"L Xu","year":"2020","unstructured":"Xu, L., Wang, M., Trenga, A., Grindel, S. & Daley, R. The ideal insertion site for the flexor digitorum profundus tendon in jersey finger repair: A biomechanical analysis. J. Hand Surg. Am. 2020, 15 (2020).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR39","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1016\/j.jhsa.2004.10.014","volume":"30","author":"K Latendresse","year":"2005","unstructured":"Latendresse, K. et al. Cyclic testing of pullout sutures and micro-mitek suture anchors in flexor digitorum profundus tendon distal fixation. J. Hand Surg. Am. 30, 471\u2013478 (2005).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR40","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1053\/jhsu.2002.35080","volume":"27","author":"FJ Leversedge","year":"2002","unstructured":"Leversedge, F. J. et al. Vascular anatomy of the human flexor digitorum profundus tendon insertion. J. Hand Surg. Am. 27, 806\u2013812 (2002).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR41","doi-asserted-by":"publisher","first-page":"2214","DOI":"10.1016\/j.jhsa.2014.07.054","volume":"39","author":"R Brar","year":"2014","unstructured":"Brar, R. et al. Reattachment of flexor digitorum profundus avulsion: Biomechanical performance of 3 techniques. J. Hand Surg. Am. 39, 2214 (2014).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR42","doi-asserted-by":"publisher","first-page":"853","DOI":"10.1016\/0363-5023(94)90201-1","volume":"19","author":"DC Rehak","year":"1994","unstructured":"Rehak, D. C., Sotereanos, D. G., Bowman, M. W. & Herndon, J. H. The Mitek bone anchor: Application to the hand, wrist and elbow. J. Hand Surg. Am. 19, 853\u2013860 (1994).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR43","doi-asserted-by":"publisher","first-page":"964","DOI":"10.1177\/1753193412469128","volume":"38","author":"A Sapienza","year":"2013","unstructured":"Sapienza, A., Yoon, H. K., Karia, R. & Lee, S. K. Flexor tendon excursion and load during passive and active simulated motion: A cadaver study. J. Hand Surg. Eur. 38, 964\u2013971 (2013).","journal-title":"J. Hand Surg. Eur."},{"key":"30373_CR44","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1053\/jhsu.1999.0295","volume":"24","author":"E McLarney","year":"1999","unstructured":"McLarney, E., Hoffman, H. & Wolfe, S. W. Biomechanical analysis of the cruciate four-strand flexor tendon repair. J. Hand Surg. Am. 24, 295\u2013301 (1999).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR45","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1177\/1753193411422793","volume":"37","author":"T Moriya","year":"2012","unstructured":"Moriya, T., Larson, M. C., Zhao, C., An, K. N. & Amadio, P. C. The effect of core suture flexor tendon repair techniques on gliding resistance during static cycle motion and load to failure: A human cadaver study. J. Hand Surg. Eur. 37, 316\u2013322 (2012).","journal-title":"J. Hand Surg. Eur."},{"key":"30373_CR46","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1016\/0266-7681(92)90020-3","volume":"17","author":"GA Robertson","year":"1992","unstructured":"Robertson, G. A. & Al-Qattan, M. M. A biomechanical analysis of a new interlock suture technique for flexor tendon repair. J. Hand Surg. Br. 17, 92\u201393 (1992).","journal-title":"J. Hand Surg. Br."},{"key":"30373_CR47","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1016\/0363-5023(92)90408-H","volume":"17","author":"F Schuind","year":"1992","unstructured":"Schuind, F., Garcia-Elias, M., Cooney, W. P. 3rd. & An, K. N. Flexor tendon forces: In vivo measurements. J. Hand Surg. Am. 17, 291\u2013298 (1992).","journal-title":"J. Hand Surg. Am."},{"key":"30373_CR48","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1080\/02844311.1993.12005639","volume":"27","author":"KL Silfverski\u00f6ld","year":"1993","unstructured":"Silfverski\u00f6ld, K. L. & May, E. J. Gap formation after flexor tendon repair in zone II. Results with a new controlled motion programme. Scand. J. Plast. Reconstr. Surg. Hand Surg. 27, 263\u2013268 (1993).","journal-title":"Scand. J. Plast. Reconstr. Surg. Hand Surg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30373-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30373-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30373-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T03:04:18Z","timestamp":1677726258000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30373-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,1]]},"references-count":48,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["30373"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-30373-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,1]]},"assertion":[{"value":"2 August 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 February 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The implants used in all study groups in this manuscript were provided by Arthex GmbH,\u00a0Munich, Germany, following an Investigator - Initiated Research Agreement. As all used implants were provided by the same company, we believe that objectivity, integrity and the value of the results were preserved. \nNo financial support, nor any other non - financial benefits were, or will be recieved. The authors declare no competing interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"3493"}}