{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T06:51:15Z","timestamp":1794293475913,"version":"4.9.0"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,3,7]],"date-time":"2023-03-07T00:00:00Z","timestamp":1678147200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,3,7]],"date-time":"2023-03-07T00:00:00Z","timestamp":1678147200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100014188","name":"Ministry of Science and ICT, South Korea","doi-asserted-by":"publisher","award":["No. 2022R1A5A1022977"],"award-info":[{"award-number":["No. 2022R1A5A1022977"]}],"id":[{"id":"10.13039\/501100014188","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Ministry of Health & Welfare, Republic of Korea","award":["No: HI20C1566"],"award-info":[{"award-number":["No: HI20C1566"]}]},{"DOI":"10.13039\/501100003052","name":"Ministry of Trade, Industry and Energy","doi-asserted-by":"publisher","award":["20010978"],"award-info":[{"award-number":["20010978"]}],"id":[{"id":"10.13039\/501100003052","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Regarding stent expansion indices, previous optical coherence tomography (OCT) studies have shown minimal stent area (MSA) to be most predictive of adverse events. We sought to evaluate the impact of various stent expansion and apposition indices by post-stent OCT on clinical outcomes and find OCT-defined optimal stent implantation criteria. A total of 1071 patients with 1123 native coronary artery lesions treated with new-generation drug-eluting stents with OCT guidance and final post-stent OCT analysis were included. Several stent expansion indices (MSA, MSA\/average reference lumen area, MSA\/distal reference lumen area, mean stent expansion, and stent expansion by linear model [stent volume\/adaptive reference lumen volume]) were evaluated for their association with device-oriented clinical endpoints (DoCE) including cardiac death, target vessel-related myocardial infarction (MI) or stent thrombosis, and target lesion revascularization. MSA was negatively correlated with the risk of DoCE (hazard ratio [HR] 0.80 [0.68\u20120.94]). However, stent expansion by linear model representing the overall volumetric stent expansion was associated with greater risk of DoCE (HR 1.02 [1.00\u20121.04]). As categorical criteria, MSA\u2009&lt;\u20095.0 mm<jats:sup>2<\/jats:sup> (HR 3.90 [1.99\u20127.65]), MSA\/distal reference lumen area\u2009&lt;\u200990% (HR 2.16 [1.12\u20124.19]), and stent expansion by linear model\u2009\u2265\u200965.0% (HR 1.95 [1.03\u20123.89]) were independently associated with DoCE. This OCT study highlights the importance of sufficient stent expansion to achieve adequate, absolute, and relative MSA criteria for improving clinical outcome. It also emphasises that overall volumetric excessive stent expansion may have detrimental effects.<\/jats:p>","DOI":"10.1038\/s41598-023-30717-6","type":"journal-article","created":{"date-parts":[[2023,3,7]],"date-time":"2023-03-07T11:04:33Z","timestamp":1678187073000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":22,"title":["Stent expansion evaluated by optical coherence tomography and subsequent outcomes"],"prefix":"10.1038","volume":"13","author":[{"given":"Bom","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Teklay Gebrehaweria","family":"Baraki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byung Gyu","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong-Joon","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seung-Jun","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sung-Jin","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chul-Min","family":"Ahn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong-Ho","family":"Shin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byeong-Keuk","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Young-Guk","family":"Ko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Donghoon","family":"Choi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Myeong-Ki","family":"Hong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yangsoo","family":"Jang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jung-Sun","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,3,7]]},"reference":[{"key":"30717_CR1","doi-asserted-by":"publisher","first-page":"995","DOI":"10.1016\/j.jacc.2004.12.066","volume":"45","author":"K Fujii","year":"2005","unstructured":"Fujii, K. et al. Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: An intravascular ultrasound study. J. Am. Coll. Cardiol. 45, 995\u2013998 (2005).","journal-title":"J. Am. Coll. Cardiol."},{"key":"30717_CR2","doi-asserted-by":"publisher","first-page":"1305","DOI":"10.1093\/eurheartj\/ehi882","volume":"27","author":"MK Hong","year":"2006","unstructured":"Hong, M. K. et al. Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation. Eur. Heart J. 27, 1305\u20131310 (2006).","journal-title":"Eur. Heart J."},{"key":"30717_CR3","doi-asserted-by":"publisher","first-page":"873","DOI":"10.1002\/ccd.24560","volume":"83","author":"HG Song","year":"2014","unstructured":"Song, H. G. et al. Intravascular ultrasound assessment of optimal stent area to prevent in-stent restenosis after zotarolimus-, everolimus-, and sirolimus-eluting stent implantation. Catheter. Cardiovasc. Interv. 83, 873\u2013878 (2014).","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"30717_CR4","doi-asserted-by":"publisher","first-page":"3281","DOI":"10.1093\/eurheartj\/ehy285","volume":"39","author":"L Raber","year":"2018","unstructured":"Raber, L. et al. Clinical use of intracoronary imaging. Part 1: Guidance and optimization of coronary interventions. An expert consensus document of the European Association of Percutaneous Cardiovascular Interventions. Eur. Heart J. 39, 3281\u20133300 (2018).","journal-title":"Eur. Heart J."},{"key":"30717_CR5","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1161\/CIRCULATIONAHA.114.014704","volume":"132","author":"T Soeda","year":"2015","unstructured":"Soeda, T. et al. Incidence and clinical significance of poststent optical coherence tomography findings: One-year follow-up study from a multicenter registry. Circulation 132, 1020\u20131029 (2015).","journal-title":"Circulation"},{"key":"30717_CR6","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1016\/j.jcmg.2015.08.013","volume":"8","author":"F Prati","year":"2015","unstructured":"Prati, F. et al. Clinical impact of OCT findings during PCI: The CLI-OPCI II study. JACC Cardiovasc. Imaging 8, 1297\u20131305 (2015).","journal-title":"JACC Cardiovasc. Imaging"},{"key":"30717_CR7","doi-asserted-by":"publisher","first-page":"906","DOI":"10.1161\/CIRCULATIONAHA.116.024393","volume":"134","author":"N Meneveau","year":"2016","unstructured":"Meneveau, N. et al. Optical coherence tomography to optimize results of percutaneous coronary intervention in patients with non-ST-elevation acute coronary syndrome: Results of the multicenter, randomized DOCTORS Study (Does Optical Coherence Tomography Optimize Results of Stenting). Circulation 134, 906\u2013917 (2016).","journal-title":"Circulation"},{"key":"30717_CR8","doi-asserted-by":"publisher","first-page":"2618","DOI":"10.1016\/S0140-6736(16)31922-5","volume":"388","author":"ZA Ali","year":"2016","unstructured":"Ali, Z. A. et al. Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): A randomised controlled trial. Lancet 388, 2618\u20132628 (2016).","journal-title":"Lancet"},{"key":"30717_CR9","doi-asserted-by":"publisher","first-page":"1467","DOI":"10.1016\/j.jcin.2018.06.049","volume":"11","author":"D Nakamura","year":"2018","unstructured":"Nakamura, D. et al. New volumetric analysis method for stent expansion and its correlation with final fractional flow reserve and clinical outcome: An ILUMIEN I substudy. JACC Cardiovasc. Interv. 11, 1467\u20131478 (2018).","journal-title":"JACC Cardiovasc. Interv."},{"key":"30717_CR10","doi-asserted-by":"publisher","first-page":"2155","DOI":"10.1001\/jama.2015.15454","volume":"314","author":"SJ Hong","year":"2015","unstructured":"Hong, S. J. et al. Effect of Intravascular ultrasound-guided vs angiography-guided everolimus-eluting stent implantation: The IVUS-XPL randomized clinical trial. JAMA 314, 2155\u20132163 (2015).","journal-title":"JAMA"},{"key":"30717_CR11","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.jcmg.2021.03.008","volume":"15","author":"BG Kim","year":"2022","unstructured":"Kim, B. G. et al. Clinical implications of poststent optical coherence tomographic findings: Severe malapposition and cardiac events. JACC Cardiovasc. Imaging 15, 126\u2013137 (2022).","journal-title":"JACC Cardiovasc. Imaging"},{"key":"30717_CR12","doi-asserted-by":"publisher","first-page":"624","DOI":"10.3349\/ymj.2018.59.5.624","volume":"59","author":"C Kim","year":"2018","unstructured":"Kim, C. et al. Randomized comparison of strut coverage between ticagrelor and clopidogrel in acute myocardial infarction at 3-month optical coherence tomography. Yonsei Med. J. 59, 624\u2013632 (2018).","journal-title":"Yonsei Med. J."},{"key":"30717_CR13","doi-asserted-by":"publisher","first-page":"1875","DOI":"10.1161\/CIRCULATIONAHA.109.873893","volume":"120","author":"A Maehara","year":"2009","unstructured":"Maehara, A. et al. Volumetric intravascular ultrasound analysis of Paclitaxel-eluting and bare metal stents in acute myocardial infarction: The harmonizing outcomes with revascularization and stents in acute myocardial infarction intravascular ultrasound substudy. Circulation 120, 1875\u20131882 (2009).","journal-title":"Circulation"},{"key":"30717_CR14","doi-asserted-by":"publisher","first-page":"3139","DOI":"10.1093\/eurheartj\/ehx351","volume":"38","author":"T Kubo","year":"2017","unstructured":"Kubo, T. et al. Optical frequency domain imaging vs. intravascular ultrasound in percutaneous coronary intervention (OPINION trial): One-year angiographic and clinical results. Eur. Heart J. 38, 3139\u20133147 (2017).","journal-title":"Eur. Heart J."},{"key":"30717_CR15","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.121.011124","volume":"14","author":"YJ Lee","year":"2021","unstructured":"Lee, Y. J. et al. Impact of intravascular ultrasound-guided optimal stent expansion on 3-year hard clinical outcomes. Circ. Cardiovasc. Interv. 14, e011124 (2021).","journal-title":"Circ. Cardiovasc. Interv."},{"key":"30717_CR16","doi-asserted-by":"publisher","first-page":"2344","DOI":"10.1161\/CIRCULATIONAHA.106.685313","volume":"115","author":"DE Cutlip","year":"2007","unstructured":"Cutlip, D. E. et al. Clinical end points in coronary stent trials: A case for standardized definitions. Circulation 115, 2344\u20132351 (2007).","journal-title":"Circulation"},{"key":"30717_CR17","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1002\/(SICI)1097-0258(19960229)15:4<361::AID-SIM168>3.0.CO;2-4","volume":"15","author":"FE Harrell Jr","year":"1996","unstructured":"Harrell, F. E. Jr., Lee, K. L. & Mark, D. B. Multivariable prognostic models: Issues in developing models, evaluating assumptions and adequacy, and measuring and reducing errors. Stat. Med. 15, 361\u2013387 (1996).","journal-title":"Stat. Med."},{"key":"30717_CR18","doi-asserted-by":"publisher","first-page":"838","DOI":"10.1002\/bimj.200510191","volume":"48","author":"AL Boulesteix","year":"2006","unstructured":"Boulesteix, A. L. Maximally selected chi-square statistics and binary splits of nominal variables. Biom. J. 48, 838\u2013848 (2006).","journal-title":"Biom. J."},{"key":"30717_CR19","doi-asserted-by":"publisher","first-page":"1269","DOI":"10.1016\/j.jcin.2009.10.005","volume":"2","author":"H Doi","year":"2009","unstructured":"Doi, H. et al. Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: An integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials. JACC Cardiovasc. Interv. 2, 1269\u20131275 (2009).","journal-title":"JACC Cardiovasc. Interv."},{"key":"30717_CR20","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1161\/CIRCULATIONAHA.117.026788","volume":"136","author":"T Adriaenssens","year":"2017","unstructured":"Adriaenssens, T. et al. Optical coherence tomography findings in patients with coronary stent thrombosis: A report of the PRESTIGE Consortium (Prevention of Late Stent Thrombosis by an Interdisciplinary Global European Effort). Circulation 136, 1007\u20131021 (2017).","journal-title":"Circulation"},{"key":"30717_CR21","doi-asserted-by":"publisher","first-page":"684","DOI":"10.1038\/s41569-022-00687-9","volume":"19","author":"M Araki","year":"2022","unstructured":"Araki, M. et al. Optical coherence tomography in coronary atherosclerosis assessment and intervention. Nat. Rev. Cardiol. 19, 684\u2013703 (2022).","journal-title":"Nat. Rev. Cardiol"},{"key":"30717_CR22","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.1016\/j.jbiomech.2012.01.033","volume":"45","author":"Y Huo","year":"2012","unstructured":"Huo, Y. et al. Which diameter and angle rule provides optimal flow patterns in a coronary bifurcation?. J. Biomech. 45, 1273\u20131279 (2012).","journal-title":"J. Biomech."},{"key":"30717_CR23","doi-asserted-by":"publisher","first-page":"1639","DOI":"10.1016\/j.jcin.2021.05.019","volume":"14","author":"T Fujimura","year":"2021","unstructured":"Fujimura, T. et al. Stent expansion indexes to predict clinical outcomes: An IVUS substudy from ADAPT-DES. JACC Cardiovasc. Interv. 14, 1639\u20131650 (2021).","journal-title":"JACC Cardiovasc. Interv."},{"key":"30717_CR24","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/S0735-1097(97)00438-5","volume":"31","author":"R Hoffmann","year":"1998","unstructured":"Hoffmann, R. et al. Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents. J. Am. Coll. Cardiol. 31, 43\u201349 (1998).","journal-title":"J. Am. Coll. Cardiol."},{"key":"30717_CR25","doi-asserted-by":"publisher","DOI":"10.1161\/JAHA.121.023493","volume":"11","author":"H Rai","year":"2022","unstructured":"Rai, H. et al. Stent optimization using optical coherence tomography and its prognostic implications after percutaneous coronary intervention. J. Am. Heart Assoc. 11, e023493 (2022).","journal-title":"J. Am. Heart Assoc."},{"key":"30717_CR26","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/0735-1097(92)90476-4","volume":"19","author":"RS Schwartz","year":"1992","unstructured":"Schwartz, R. S. et al. Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine model. J. Am. Coll. Cardiol. 19, 267\u2013274 (1992).","journal-title":"J. Am. Coll. Cardiol."},{"key":"30717_CR27","doi-asserted-by":"publisher","first-page":"1170","DOI":"10.1016\/S0002-9149(99)00053-3","volume":"83","author":"R Hoffmann","year":"1999","unstructured":"Hoffmann, R. et al. Tissue proliferation within and surrounding Palmaz-Schatz stents is dependent on the aggressiveness of stent implantation technique. Am. J. Cardiol. 83, 1170\u20131174 (1999).","journal-title":"Am. J. Cardiol."},{"key":"30717_CR28","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1016\/S0002-9149(00)01075-4","volume":"86","author":"J Koyama","year":"2000","unstructured":"Koyama, J. et al. Relation between vascular morphologic changes during stent implantation and the magnitude of in-stent neointimal hyperplasia. Am. J. Cardiol. 86, 753\u2013758 (2000).","journal-title":"Am. J. Cardiol."},{"key":"30717_CR29","doi-asserted-by":"publisher","first-page":"2178","DOI":"10.1161\/01.CIR.93.12.2178","volume":"93","author":"NA Scott","year":"1996","unstructured":"Scott, N. A. et al. Identification of a potential role for the adventitia in vascular lesion formation after balloon overstretch injury of porcine coronary arteries. Circulation 93, 2178\u20132187 (1996).","journal-title":"Circulation"},{"key":"30717_CR30","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.116.004231","volume":"9","author":"Y Ino","year":"2016","unstructured":"Ino, Y. et al. Optical coherence tomography predictors for edge restenosis after everolimus-eluting stent implantation. Circ. Cardiovasc. Interv. 9, e004231 (2016).","journal-title":"Circ. Cardiovasc. Interv."},{"key":"30717_CR31","doi-asserted-by":"publisher","first-page":"694","DOI":"10.4070\/kcj.2017.0016","volume":"47","author":"SJ Hong","year":"2017","unstructured":"Hong, S. J. et al. Effect of adjunct balloon dilation after long everolimus-eluting stent deployment on major adverse cardiac events. Korean Circ. J. 47, 694\u2013704 (2017).","journal-title":"Korean Circ. J."},{"key":"30717_CR32","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCINTERVENTIONS.121.011366","volume":"15","author":"YJ Lee","year":"2022","unstructured":"Lee, Y. J. et al. Is routine postdilation during angiography-guided stent implantation as good as intravascular ultrasound guidance? An analysis using data from IVUS-XPL and ULTIMATE. Circ. Cardiovasc. Interv. 15, e011366 (2022).","journal-title":"Circ. Cardiovasc. Interv."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30717-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30717-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30717-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,7]],"date-time":"2023-03-07T11:12:49Z","timestamp":1678187569000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30717-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,7]]},"references-count":32,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["30717"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-30717-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,7]]},"assertion":[{"value":"22 December 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 February 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"3781"}}