{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,25]],"date-time":"2026-10-25T19:33:10Z","timestamp":1792956790854,"version":"4.5.0"},"reference-count":50,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T00:00:00Z","timestamp":1677715200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T00:00:00Z","timestamp":1677715200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Hip joint prostheses are used to replace hip joint function in the human body. The latest dual-mobility hip joint prosthesis has an additional component of an outer liner that acts as a cover for the liner component. Research on the contact pressure generated on the latest model of a dual-mobility hip joint prosthesis under a gait cycle has never been done before. The model is made of ultrahigh molecular weight polyethylene (UHMWPE) on the inner liner and 316L stainless steel (SS 316L) on the outer liner and acetabular cup. Simulation modeling using the finite element method is considered static loading with an implicit solver for studying the geometric parameter design of dual-mobility hip joint prostheses. In this study, simulation modeling was carried out by applying varying inclination angles of 30\u00b0, 40\u00b0, 45\u00b0, 50\u00b0, 60\u00b0, and 70\u00b0 to the acetabular cup component. Three-dimensional loads were placed on femoral head reference points with variations of femoral head diameter used at 22\u00a0mm, 28\u00a0mm, and 32\u00a0mm. The results in the inner surface of the inner liner, the outer surface of the outer liner, and the inner surface of the acetabular cup showed that the variations in inclination angle do not have a major effect on the maximum contact pressure value on the liner component, where the acetabular cup with an inclination angle of 45\u00b0 can reduce contact pressure more than the other studied inclination angle variations. In addition, it was found that the 22\u00a0mm diameter of the femoral head increases the contact pressure. The use of a larger diameter femoral head with an acetabular cup configuration at a 45\u00b0 inclination can minimize the risk of implant failure due to wear.<\/jats:p>","DOI":"10.1038\/s41598-023-30725-6","type":"journal-article","created":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T15:02:58Z","timestamp":1677769378000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":65,"title":["Analysis of contact pressure in a 3D model of dual-mobility hip joint prosthesis under a gait cycle"],"prefix":"10.1038","volume":"13","author":[{"given":"Mohammad","family":"Tauviqirrahman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad Imam","family":"Ammarullah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Jamari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eko","family":"Saputra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tri Indah","family":"Winarni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Febri Dwi","family":"Kurniawan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shidnan Amir","family":"Shiddiq","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emile","family":"van der Heide","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,3,2]]},"reference":[{"key":"30725_CR1","doi-asserted-by":"publisher","first-page":"1125","DOI":"10.1007\/s00264-014-2313-2","volume":"38","author":"J Caton","year":"2014","unstructured":"Caton, J., Prudhon, J. L., Ferreira, A., Aslanian, T. & Verdier, R. International orthopaedics. Int. Orthop. 38, 1125\u20131129 (2014).","journal-title":"Int. Orthop."},{"key":"30725_CR2","doi-asserted-by":"publisher","first-page":"528","DOI":"10.3390\/medicina58040528","volume":"58","author":"I Aguado-Maestro","year":"2022","unstructured":"Aguado-Maestro, I. et al. Dual mobility cups as the routine choice in total hip arthroplasty. Medicina (B. Aires) 58, 528 (2022).","journal-title":"Medicina (B. Aires)"},{"key":"30725_CR3","doi-asserted-by":"publisher","first-page":"2898","DOI":"10.1016\/j.arth.2017.03.056","volume":"32","author":"J Jamari","year":"2017","unstructured":"Jamari, J., Anwar, I. B., Saputra, E. & van der Heide, E. Range of motion simulation of hip joint movement during salat activity. J. Arthroplasty 32, 2898\u20132904 (2017).","journal-title":"J. Arthroplasty"},{"key":"30725_CR4","doi-asserted-by":"publisher","first-page":"70","DOI":"10.3390\/geriatrics6030070","volume":"6","author":"RL Alberio","year":"2021","unstructured":"Alberio, R. L., Rusconi, M., Martinetti, L., Monzeglio, D. & Grassi, F. A. Total hip arthroplasty (THA) for femoral neck fractures: Comparison between standard and dual mobility implants. Geriatrics 6, 70 (2021).","journal-title":"Geriatrics"},{"key":"30725_CR5","doi-asserted-by":"publisher","DOI":"10.3990\/1.9789036552264","volume-title":"The Tribological Behaviour of the Dual Mobility Hip Prosthesis in Relation to Impingement","author":"S Eko","year":"2021","unstructured":"Eko, S. The Tribological Behaviour of the Dual Mobility Hip Prosthesis in Relation to Impingement (University of Twente, 2021). https:\/\/doi.org\/10.3990\/1.9789036552264."},{"key":"30725_CR6","doi-asserted-by":"publisher","first-page":"2411","DOI":"10.1007\/s00264-012-1678-3","volume":"36","author":"A Grazioli","year":"2012","unstructured":"Grazioli, A., Ek, E. T. H. & R\u00fcdiger, H. A. Biomechanical concept and clinical outcome of dual mobility cups. Int. Orthop. 36, 2411\u20132418 (2012).","journal-title":"Int. Orthop."},{"key":"30725_CR7","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-95387-8","volume":"11","author":"P Damm","year":"2021","unstructured":"Damm, P., Bender, A., Waldheim, V., Winkler, T. & Duda, G. N. Surgical cup placement affects the heating up of total joint hip replacements. Sci. Rep. 11, 15851 (2021).","journal-title":"Sci. Rep."},{"key":"30725_CR8","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41598-016-0001-8","volume":"6","author":"Z Cui","year":"2016","unstructured":"Cui, Z., Tian, Y. X., Yue, W., Yang, L. & Li, Q. Tribo-biological deposits on the articulating surfaces of metal-on-polyethylene total hip implants retrieved from patients. Sci. Rep. 6, 1\u20138 (2016).","journal-title":"Sci. Rep."},{"key":"30725_CR9","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/j.jor.2021.04.004","volume":"25","author":"A Bistolfi","year":"2021","unstructured":"Bistolfi, A. et al. Ultra-high molecular weight polyethylene (UHMWPE) for hip and knee arthroplasty: The present and the future. J. Orthop. 25, 98\u2013106 (2021).","journal-title":"J. Orthop."},{"key":"30725_CR10","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-017-11225-w","volume":"7","author":"A Di Laura","year":"2017","unstructured":"Di Laura, A. et al. The chemical form of metal species released from corroded taper junctions of hip implants: Synchrotron analysis of patient tissue. Sci. Rep. 7, 10952 (2017).","journal-title":"Sci. Rep."},{"key":"30725_CR11","doi-asserted-by":"publisher","first-page":"5729","DOI":"10.1038\/srep05729","volume":"4","author":"B Scharf","year":"2015","unstructured":"Scharf, B. et al. Molecular analysis of chromium and cobalt-related toxicity. Sci. Rep. 4, 5729 (2015).","journal-title":"Sci. Rep."},{"key":"30725_CR12","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-99053-x","volume":"11","author":"S Hochgeschurz","year":"2021","unstructured":"Hochgeschurz, S. et al. Author Correction: Avian extremity reconstruction via osseointegrated leg-prosthesis for intuitive embodiment. Sci. Rep. 11, 19231 (2021).","journal-title":"Sci. Rep."},{"key":"30725_CR13","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.otsr.2013.12.011","volume":"100","author":"P Adam","year":"2014","unstructured":"Adam, P., Farizon, F. & Fessy, M. H. Dual mobility retentive acetabular liners and wear: Surface analysis of 40 retrieved polyethylene implants. Orthop. Traumatol. Surg. Res. 100, 85\u201391 (2014).","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"30725_CR14","doi-asserted-by":"publisher","DOI":"10.1038\/srep20909","volume":"6","author":"Y Zhao","year":"2016","unstructured":"Zhao, Y. et al. Progranulin suppresses titanium particle induced inflammatory osteolysis by targeting TNF\u03b1 signaling. Sci. Rep. 6, 20909 (2016).","journal-title":"Sci. Rep."},{"key":"30725_CR15","doi-asserted-by":"publisher","DOI":"10.1038\/srep39612","volume":"7","author":"M Eger","year":"2017","unstructured":"Eger, M., Sterer, N., Liron, T., Kohavi, D. & Gabet, Y. Scaling of titanium implants entrains inflammation-induced osteolysis. Sci. Rep. 7, 39612 (2017).","journal-title":"Sci. Rep."},{"key":"30725_CR16","first-page":"1","volume":"1725","author":"E Saputra","year":"2016","unstructured":"Saputra, E., Anwar, I. B., Ismail, R., Jamari, J. & Van Der Heide, E. Finite element study of contact pressure distribution on inner and outer liner in the bipolar hip prosthesis. AIP Conf. Proc. 1725, 1\u20136 (2016).","journal-title":"AIP Conf. Proc."},{"key":"30725_CR17","doi-asserted-by":"publisher","first-page":"23","DOI":"10.3390\/geriatrics6010023","volume":"6","author":"JM Lamo-Espinosa","year":"2021","unstructured":"Lamo-Espinosa, J. M. et al. Cemented dual mobility cup for primary total hip arthroplasty in elder patients with high-risk instability. Geriatrics 6, 23 (2021).","journal-title":"Geriatrics"},{"key":"30725_CR18","doi-asserted-by":"publisher","DOI":"10.3390\/ma13092040","volume":"13","author":"S Affatato","year":"2020","unstructured":"Affatato, S. et al. Revision of a monoblock metal-on-metal cup using a dual mobility component: Is it a reasonable option?. Materials (Basel) 13, 2040 (2020).","journal-title":"Materials (Basel)"},{"key":"30725_CR19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12891-022-05280-2","volume":"23","author":"D Tigani","year":"2022","unstructured":"Tigani, D., Banci, L., Valtorta, R. & Amendola, L. Hip stability parameters with dual mobility, modular dual mobility and fixed bearing in total hip arthroplasty: An analytical evaluation. BMC Musculoskelet. Disord. 23, 1\u201310 (2022).","journal-title":"BMC Musculoskelet. Disord."},{"key":"30725_CR20","doi-asserted-by":"publisher","DOI":"10.3390\/ma14227066","volume":"14","author":"L Maslov","year":"2021","unstructured":"Maslov, L. et al. Finite element analysis of customized acetabular implant and bone after pelvic tumour resection throughout the gait cycle. Materials (Basel) 14, 7066 (2021).","journal-title":"Materials (Basel)"},{"key":"30725_CR21","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/jpm11080780","volume":"11","author":"C Gonz\u00e1lez-bravo","year":"2021","unstructured":"Gonz\u00e1lez-bravo, C., Ortega, M. A., Buj\u00e1n, J., de la Torre, B. & Barrios, L. Wear risk prevention and reduction in total hip arthroplasty. A personalized study comparing cement and cementless fixation techniques employing finite element analysis. J. Pers. Med. 11, 1\u201316 (2021).","journal-title":"J. Pers. Med."},{"key":"30725_CR22","doi-asserted-by":"publisher","first-page":"64","DOI":"10.3390\/jfb13020064","volume":"13","author":"J Jamari","year":"2022","unstructured":"Jamari, J. et al. Computational contact pressure prediction of CoCrMo, SS 316L and Ti6Al4V femoral head against UHMWPE acetabular cup under gait cycle. J. Funct. Biomater. 13, 64 (2022).","journal-title":"J. Funct. Biomater."},{"key":"30725_CR23","doi-asserted-by":"publisher","DOI":"10.3390\/app12073698","volume":"12","author":"HK Lee","year":"2022","unstructured":"Lee, H. K., Kim, S. M. & Lim, H. S. Computational wear prediction of TKR with flatback deformity during gait. Appl. Sci. 12, 3698 (2022).","journal-title":"Appl. Sci."},{"key":"30725_CR24","doi-asserted-by":"publisher","DOI":"10.1088\/1742-6596\/1198\/4\/042012","volume":"1198","author":"H Basri","year":"2019","unstructured":"Basri, H. et al. The analysis of dimple geometry on artificial hip joint to the performance of lubrication. J. Phys. Conf. Ser. 1198, 042012 (2019).","journal-title":"J. Phys. Conf. Ser."},{"key":"30725_CR25","doi-asserted-by":"publisher","first-page":"2395","DOI":"10.3390\/app12052395","volume":"12","author":"I Tijjani","year":"2022","unstructured":"Tijjani, I., Kumar, S. & Boukheddimi, M. A survey on design and control of lower extremity exoskeletons for bipedal walking. Appl. Sci. 12, 2395 (2022).","journal-title":"Appl. Sci."},{"key":"30725_CR26","doi-asserted-by":"publisher","DOI":"10.3390\/app11052123","volume":"11","author":"G Valente","year":"2021","unstructured":"Valente, G., Taddei, F., Leardini, A. & Benedetti, M. G. Effects of hip abductor strengthening on musculoskeletal loading in hip dysplasia patients after total hip replacement. Appl. Sci. 11, 2123 (2021).","journal-title":"Appl. Sci."},{"key":"30725_CR27","doi-asserted-by":"publisher","DOI":"10.1016\/j.heliyon.2022.e12050","volume":"8","author":"J Jamari","year":"2022","unstructured":"Jamari, J. et al. Adopted walking condition for computational simulation approach on bearing of hip joint prosthesis: Review over the past 30 years. Heliyon 8, e12050 (2022).","journal-title":"Heliyon"},{"key":"30725_CR28","doi-asserted-by":"publisher","first-page":"334","DOI":"10.24874\/ti.1233.12.21.03","volume":"44","author":"M Chernets","year":"2022","unstructured":"Chernets, M., Chernets, Y. & Zubrzycki, J. A study on the relationship between contact pressures in a Grade2 TDN\u2013UHMWPE hip implant: Young\u2019s modulus and poisson\u2019s ratio. Tribol. Ind. 44, 334\u2013342 (2022).","journal-title":"Tribol. Ind."},{"key":"30725_CR29","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.3390\/met12081241","volume":"12","author":"J Jamari","year":"2022","unstructured":"Jamari, J. et al. In silico contact pressure of metal-on-metal total hip implant with different materials subjected to gait loading. Metals (Basel) 12, 1241 (2022).","journal-title":"Metals (Basel)"},{"key":"30725_CR30","doi-asserted-by":"publisher","first-page":"503","DOI":"10.3390\/jcm8040503","volume":"8","author":"L Bayam","year":"2019","unstructured":"Bayam, L., Drampalos, E., Nagai, H. & Kay, P. Conversion of failed hip hemiarthroplasty to low friction arthroplasty (LFA). J. Clin. Med. 8, 503 (2019).","journal-title":"J. Clin. Med."},{"key":"30725_CR31","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.clinbiomech.2018.06.009","volume":"57","author":"Y Gao","year":"2018","unstructured":"Gao, Y., Chen, Z., Zhang, Z., Chen, S. & Jin, Z. Effect of inclination and anteversion angles on kinematics and contact mechanics of dual mobility hip implants. Clin. Biomech. 57, 48\u201355 (2018).","journal-title":"Clin. Biomech."},{"key":"30725_CR32","first-page":"1","volume":"16","author":"J Bourget-Murray","year":"2021","unstructured":"Bourget-Murray, J. et al. Computational modelling of hip resurfacing arthroplasty investigating the effect of femoral version on hip biomechanics. PLoS\u00a0One 16, 1\u201312 (2021).","journal-title":"PLoS\u00a0One"},{"key":"30725_CR33","first-page":"31","volume":"33","author":"MI Ammarullah","year":"2022","unstructured":"Ammarullah, M. I. et al. Tresca stress study of CoCrMo-on-CoCrMo bearings based on body mass index using 2D computational model. Jurnal Tribologi 33, 31\u201338 (2022).","journal-title":"Jurnal Tribologi"},{"key":"30725_CR34","doi-asserted-by":"publisher","first-page":"3683","DOI":"10.3390\/app11083683","volume":"11","author":"A Amor-Martin","year":"2021","unstructured":"Amor-Martin, A. & Garcia-Castillo, L. E. Adaptive semi-structured mesh refinement techniques for the finite element method. Appl. Sci. 11, 3683 (2021).","journal-title":"Appl. Sci."},{"key":"30725_CR35","first-page":"8","volume":"181","author":"JP Paul","year":"1966","unstructured":"Paul, J. P. Forces transmitted by the joints in the human body. Proc. Inst. Mech. Eng. 181, 8\u201315 (1966).","journal-title":"Proc. Inst. Mech. Eng."},{"key":"30725_CR36","doi-asserted-by":"publisher","first-page":"S143","DOI":"10.1016\/j.matpr.2022.02.055","volume":"63","author":"MI Ammarullah","year":"2022","unstructured":"Ammarullah, M. I. et al. Tresca stress evaluation of metal-on-UHMWPE total hip arthroplasty during peak loading from normal walking activity. Mater. Today Proc. 63, S143\u2013S146 (2022).","journal-title":"Mater. Today Proc."},{"key":"30725_CR37","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1177\/0954411915585380","volume":"229","author":"Y Gao","year":"2015","unstructured":"Gao, Y., Jin, Z., Wang, L. & Wang, M. Finite element analysis of sliding distance and contact mechanics of hip implant under dynamic walking conditions. Proc. Inst. Mech. Eng. Part H J. Eng. Med. 229, 469\u2013474 (2015).","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"30725_CR38","first-page":"466","volume":"43","author":"LA Korduba","year":"2014","unstructured":"Korduba, L. A. et al. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing. Am. J. Orthop. (Belle Mead. NJ) 43, 466\u2013471 (2014).","journal-title":"Am. J. Orthop. (Belle Mead. NJ)"},{"key":"30725_CR39","doi-asserted-by":"publisher","first-page":"53","DOI":"10.3390\/prosthesis3010006","volume":"3","author":"G Solarino","year":"2021","unstructured":"Solarino, G. et al. Preliminary results of total hip arthroplasty in subjects at risk for dislocation using a novel modular cementless dual-mobility cup. A single-center prospective study. Prosthesis 3, 53\u201360 (2021).","journal-title":"Prosthesis"},{"key":"30725_CR40","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-022-04774-2","volume":"12","author":"NH Moon","year":"2022","unstructured":"Moon, N. H., Do, M. U., Kim, J. S., Seo, J. S. & Shin, W. C. The usefulness of dual mobility cups in primary total hip arthroplasty patients at a risk of dislocation. Sci. Rep. 12, 1\u20137 (2022).","journal-title":"Sci. Rep."},{"key":"30725_CR41","doi-asserted-by":"publisher","first-page":"38","DOI":"10.3390\/jfb12020038","volume":"12","author":"J Jamari","year":"2021","unstructured":"Jamari, J. et al. The effect of bottom profile dimples on the femoral head on wear in metal-on-metal total hip arthroplasty. J. Funct. Biomater. 12, 38 (2021).","journal-title":"J. Funct. Biomater."},{"key":"30725_CR42","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.1080\/10255842.2014.936856","volume":"18","author":"MS Uddin","year":"2015","unstructured":"Uddin, M. S. Contact of dual mobility implants: Effects of cup wear and inclination. Comput. Methods Biomech. Biomed. Eng. 18, 1611\u20131621 (2015).","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"30725_CR43","doi-asserted-by":"publisher","DOI":"10.3390\/su142013413","volume":"14","author":"MI Ammarullah","year":"2022","unstructured":"Ammarullah, M. I. et al. Minimizing risk of failure from ceramic-on-ceramic total hip prosthesis by selecting ceramic materials based on tresca stress. Sustainability 14, 13413 (2022).","journal-title":"Sustainability"},{"key":"30725_CR44","doi-asserted-by":"publisher","first-page":"321","DOI":"10.3390\/biomechanics1030027","volume":"1","author":"A Lipphaus","year":"2021","unstructured":"Lipphaus, A., Klimek, M. & Witzel, U. Comparative finite element analysis of fixation techniques for APC II open-book injuries of the pelvis. Biomechanics 1, 321\u2013333 (2021).","journal-title":"Biomechanics"},{"key":"30725_CR45","doi-asserted-by":"publisher","DOI":"10.3390\/ma14247554","volume":"14","author":"MI Ammarullah","year":"2021","unstructured":"Ammarullah, M. I. et al. Tresca stress simulation of metal-on-metal total hip arthroplasty during normal walking activity. Materials (Basel) 14, 7554 (2021).","journal-title":"Materials (Basel)"},{"key":"30725_CR46","doi-asserted-by":"publisher","DOI":"10.3390\/ijms23063266","volume":"23","author":"H Farah","year":"2022","unstructured":"Farah, H. et al. Differential metabotypes in synovial fibroblasts and synovial fluid in hip osteoarthritis patients support inflammatory responses. Int. J. Mol. Sci. 23, 3266 (2022).","journal-title":"Int. J. Mol. Sci."},{"key":"30725_CR47","doi-asserted-by":"publisher","DOI":"10.3390\/ma15072573","volume":"15","author":"M Prado-Novoa","year":"2022","unstructured":"Prado-Novoa, M., Perez-Sanchez, L., Estebanez, B., Moreno-Vegas, S. & Perez-Blanca, A. Influence of loading conditions on the mechanical performance of multifilament coreless UHMWPE sutures used in orthopaedic surgery. Materials (Basel) 15, 2573 (2022).","journal-title":"Materials (Basel)"},{"key":"30725_CR48","doi-asserted-by":"publisher","DOI":"10.3390\/polym12020483","volume":"12","author":"R Zhang","year":"2020","unstructured":"Zhang, R. et al. Effect of PEW and CS on the thermal, mechanical, and shape memory properties of UHMWPE. Polymers (Basel) 12, 483 (2020).","journal-title":"Polymers (Basel)"},{"key":"30725_CR49","first-page":"1","volume":"9","author":"KN Chethan","year":"2022","unstructured":"Chethan, K. N., Bhat, N. S., Zuber, M. & Shenoy, B. S. Evolution of different designs and wear studies in total hip prosthesis using finite element analysis: A review. Cogent Eng. 9, 1\u201330 (2022).","journal-title":"Cogent Eng."},{"key":"30725_CR50","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1186\/s12893-022-01804-8","volume":"22","author":"M Wang","year":"2022","unstructured":"Wang, M. et al. 3D-printed hemipelvic prosthesis combined with a dual mobility bearing in patients with primary malignant neoplasm involving the acetabulum: Clinical outcomes and finite element analysis. BMC Surg. 22, 357 (2022).","journal-title":"BMC Surg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30725-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30725-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30725-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,2]],"date-time":"2023-03-02T16:14:16Z","timestamp":1677773656000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-30725-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,2]]},"references-count":50,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["30725"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-30725-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,2]]},"assertion":[{"value":"29 April 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 February 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"3564"}}