{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T05:57:44Z","timestamp":1791352664892,"version":"4.3.1"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,3,18]],"date-time":"2023-03-18T00:00:00Z","timestamp":1679097600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,3,18]],"date-time":"2023-03-18T00:00:00Z","timestamp":1679097600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"China National Key R&D Program during the \u201c10th Five-Year Plan\u201d","award":["2019YFD1101003"],"award-info":[{"award-number":["2019YFD1101003"]}]},{"name":"Scientific Research Project of Department of Housing and Urban-Rural Development of Gansu Province","award":["JK2020-26"],"award-info":[{"award-number":["JK2020-26"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>For lightweight steel frame structures consisting of steel H-beams and cold-formed steel columns filled with concrete, seismic performance comparison tests and numerical simulation analyses were performed for bare and infilled frames. The effects of the lightweight wall panels, the axial compression ratio and the wall thickness of the steel sections of the columns on the seismic properties of the structure were investigated. The failure of the bare frame was concentrated in the weld fractures at the beam-column joints. When the wall panels were embedded in the frame, the damage was concentrated at the corners and edges of the wall panels and the connectors. The wall panels significantly improved the initial stiffness of the frame, early energy dissipation and resistance, and the wall panel energy dissipation rate was initially as great as 91%. As the axial compression ratio increased, the resistance of the structure significantly decreased. Under monotonic loading, the resistance on the structure with an axial compression ratio of 0.4 was reduced by nearly 44% compared to the structure without axial compression. Increasing the wall thickness of the steel sections of the columns increased the load-bearing capacity of the structure, but the increase diminished with increasing wall thickness.<\/jats:p>","DOI":"10.1038\/s41598-023-31789-0","type":"journal-article","created":{"date-parts":[[2023,3,26]],"date-time":"2023-03-26T16:03:17Z","timestamp":1679846597000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Experimental study on the seismic performance of a cold-formed thin-walled steel\u2013concrete composite column-H steel beam frame"],"prefix":"10.1038","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7018-1546","authenticated-orcid":false,"given":"HongJie","family":"Hou","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0450-7066","authenticated-orcid":false,"given":"ZhiHua","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5579-4763","authenticated-orcid":false,"given":"XiuLi","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,3,18]]},"reference":[{"key":"31789_CR1","unstructured":"Technical Code of Cold-Formed Thin-Wall Steel Structures (GB50018-2002). China Planning Press (2003)."},{"issue":"06","key":"31789_CR2","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1007\/s12205-020-0519-y","volume":"24","author":"YP Chu","year":"2020","unstructured":"Chu, Y. P. et al. Experimental research on the shear performance of the two-storey composite cold-formed thin-walled steel wall. KSCE J. Civ. Eng. 24(06), 537\u2013550. https:\/\/doi.org\/10.1007\/s12205-020-0519-y (2020).","journal-title":"KSCE J. Civ. Eng."},{"key":"31789_CR3","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcsr.2020.106168","author":"YP Chu","year":"2020","unstructured":"Chu, Y. P., Hou, H. J. & Yao, Y. Experimental study on shear performance of composite cold-formed ultra-thin-walled steel shear wall. J. Construct. Steel Res. https:\/\/doi.org\/10.1016\/j.jcsr.2020.106168 (2020).","journal-title":"J. Construct. Steel Res."},{"issue":"01","key":"31789_CR4","doi-asserted-by":"publisher","first-page":"012065","DOI":"10.1088\/1757-899X\/794\/1\/012065","volume":"794","author":"L Liu","year":"2020","unstructured":"Liu, L., Yao, Y. & Chu, Y. P. Study on seismic behaviour of cold formed steel structure based on simplified mechanical model. IOP Conf. Ser. Mater. Sci. Eng. 794(01), 012065. https:\/\/doi.org\/10.1088\/1757-899X\/794\/1\/012065 (2020).","journal-title":"IOP Conf. Ser. Mater. Sci. Eng."},{"key":"31789_CR5","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.jcsr.2019.01.013","volume":"156","author":"Y Jun","year":"2019","unstructured":"Jun, Y., Mojtabaei, S. M. & Hajirasouliha, I. Seismic performance of cold-formed steel bolted moment connections with bolting friction-slip mechanism. J. Constr. Steel Res. 156, 122\u2013136. https:\/\/doi.org\/10.1016\/j.jcsr.2019.01.013 (2019).","journal-title":"J. Constr. Steel Res."},{"issue":"7","key":"31789_CR6","doi-asserted-by":"publisher","first-page":"04020126","DOI":"10.1061\/(ASCE)ST.1943-541X.0002677","volume":"146","author":"FJ Meza","year":"2020","unstructured":"Meza, F. J., Becque, J. & Hajirasouliha, I. Experimental study of cold-formed steel built-up beams. J. Struct. Eng. 146(7), 04020126. https:\/\/doi.org\/10.1061\/(ASCE)ST.1943-541X.0002677 (2020).","journal-title":"J. Struct. Eng."},{"key":"31789_CR7","doi-asserted-by":"publisher","first-page":"111532","DOI":"10.1016\/j.engstruct.2020.111532","volume":"228","author":"XH Zhou","year":"2020","unstructured":"Zhou, X. H. et al. Simplified design method of cold-formed steel columns with built-up box sections. Eng. Struct. 228, 111532. https:\/\/doi.org\/10.1016\/j.engstruct.2020.111532 (2020).","journal-title":"Eng. Struct."},{"key":"31789_CR8","doi-asserted-by":"publisher","first-page":"380","DOI":"10.1016\/j.jcsr.2018.04.008","volume":"147","author":"JH Zhang","year":"2018","unstructured":"Zhang, J. H. & Young, B. Experimental investigation of cold-formed steel built-up closed section columns with web stiffeners. J. Construct. Steel Res. 147, 380\u2013392. https:\/\/doi.org\/10.1016\/j.jcsr.2018.04.008 (2018).","journal-title":"J. Construct. Steel Res."},{"key":"31789_CR9","doi-asserted-by":"publisher","first-page":"103854","DOI":"10.1016\/j.jobe.2021.103854","volume":"48","author":"R Rohola","year":"2021","unstructured":"Rohola, R. et al. Fire resistance of concrete-filled cold-formed steel (CF-CFS) built-up short columns. J. Build. Eng. 48, 103854. https:\/\/doi.org\/10.1016\/j.jobe.2021.103854 (2021).","journal-title":"J. Build. Eng."},{"key":"31789_CR10","doi-asserted-by":"publisher","first-page":"109603","DOI":"10.1016\/j.tws.2022.109603","volume":"179","author":"R Rohola","year":"2022","unstructured":"Rohola, R., H\u00e9lder, D. C. & Marco, L. Concrete-filled cold-formed steel (CF-CFS) built-up columns under compression: test and design. Thin-Wall Struct. 179, 109603. https:\/\/doi.org\/10.1016\/j.tws.2022.109603 (2022).","journal-title":"Thin-Wall Struct."},{"issue":"S1","key":"31789_CR11","doi-asserted-by":"publisher","first-page":"44","DOI":"10.14006\/j.jzjgxb.2018.S1.007","volume":"39","author":"Q Liao","year":"2018","unstructured":"Liao, Q., Li, B. X. & Shi, Y. X. Experimental study on seismic performance of RC frames filled with lightweight wallboards. J. Build. Struct. 39(S1), 44\u201351. https:\/\/doi.org\/10.14006\/j.jzjgxb.2018.S1.007 (2018).","journal-title":"J. Build. Struct."},{"issue":"07","key":"31789_CR12","doi-asserted-by":"publisher","first-page":"103","DOI":"10.14006\/j.jzjgxb.2017.07.013","volume":"38","author":"HC Guo","year":"2017","unstructured":"Guo, H. C. et al. Experimental research on seismic behavior of flexible steel frame with infilling recycled concrete wall. J. Build. Struct. 38(07), 103\u2013112128. https:\/\/doi.org\/10.14006\/j.jzjgxb.2017.07.013 (2017).","journal-title":"J. Build. Struct."},{"issue":"02","key":"31789_CR13","doi-asserted-by":"publisher","first-page":"268","DOI":"10.3969\/j.issn.1007-9626.2012.02.024","volume":"15","author":"XS Qu","year":"2012","unstructured":"Qu, X. S., Chen, Z. H. & Sun, G. J. Experimental and numerical analysis study on the structural performance of autoclaved aerated concrete (AAC) wall slab. J. Build. Mater. 15(02), 268\u2013273. https:\/\/doi.org\/10.3969\/j.issn.1007-9626.2012.02.024 (2012).","journal-title":"J. Build. Mater."},{"issue":"12","key":"31789_CR14","doi-asserted-by":"publisher","first-page":"21","DOI":"10.14006\/j.jzjgxb.2018.0297","volume":"40","author":"HT Hou","year":"2019","unstructured":"Hou, H. T. et al. Shake table tests of exterior sandwich composite walls flexibly connected to full-scale steel braced frames. J. Build. Struct. 40(12), 21\u201331. https:\/\/doi.org\/10.14006\/j.jzjgxb.2018.0297 (2019).","journal-title":"J. Build. Struct."},{"issue":"08","key":"31789_CR15","doi-asserted-by":"publisher","first-page":"9","DOI":"10.14006\/j.jzjgxb.2015.08.002","volume":"36","author":"ZG Cao","year":"2015","unstructured":"Cao, Z. G. et al. Experimental research on seismic performance of fabricated frames with lightweight infill walls. J. Build. Struct. 36(08), 9\u201315. https:\/\/doi.org\/10.14006\/j.jzjgxb.2015.08.002 (2015).","journal-title":"J. Build. Struct."},{"key":"31789_CR16","unstructured":"Metallic Materials Tensile Testing at Ambient Temperature (GB\/T 228-2002). Standard Press of China (2002)."},{"key":"31789_CR17","unstructured":"Standard for Test Method of Mechanical Properties on Ordinary Concrete (GB\/T 50081-2002). China Architecture and Building Press (2003)."},{"key":"31789_CR18","volume-title":"Concrete Filled Steel Tubular Structures","author":"ML Han","year":"2004","unstructured":"Han, M. L. Concrete Filled Steel Tubular Structures (Science Press, 2004)."},{"key":"31789_CR19","unstructured":"Code for Design of Concrete Structures (GB\/T 50010-2010). China Architecture and Building Press (2015)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-31789-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-31789-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-31789-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,26]],"date-time":"2023-03-26T16:06:36Z","timestamp":1679846796000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-31789-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,18]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["31789"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-31789-0","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2418315\/v1","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,18]]},"assertion":[{"value":"27 December 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 March 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"4486"}}