{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T15:50:36Z","timestamp":1768405836643,"version":"3.49.0"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,3,29]],"date-time":"2023-03-29T00:00:00Z","timestamp":1680048000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,3,29]],"date-time":"2023-03-29T00:00:00Z","timestamp":1680048000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Tissue containment systems (TCS) are medical devices that may be used during morcellation procedures during minimally invasive laparoscopic surgery. TCS are not new devices but their use as a potential mitigation for the spread of occult malignancy during laparoscopic power morcellation of fibroids and\/or the uterus has been the subject of interest following reports of upstaging of previously undetected sarcoma in women who underwent a laparoscopic hysterectomy. Development of standardized test methods and acceptance criteria to evaluate the safety and performance of these devices will speed development, allowing for more devices to benefit patients. As a part of this study, a series of preclinical experimental bench test methods were developed to evaluate the mechanical and leakage performance of TCS that may be used in power morcellation procedures. Experimental tests were developed to evaluate mechanical integrity, e.g., tensile, burst, puncture, and penetration strengths for the TCS, and leakage integrity, e.g., dye and microbiological leakage (both acting as surrogates for blood and cancer cells) through the TCS. In addition, to evaluate both mechanical integrity and leakage integrity as a combined methodology, partial puncture and dye leakage was conducted on the TCS to evaluate the potential for leakage due to partial damage caused by surgical tools. Samples from 7 different TCSs were subjected to preclinical bench testing to evaluate leakage and mechanical performance. The performance of the TCSs varied significantly between different brands. The leakage pressure of the TCS varied between 26 and &gt;\u20091293\u00a0mmHg for the 7 TCS brands. Similarly, the tensile force to failure, burst pressure, and puncture force varied between 14 and 80\u00a0MPa, 2 and 78 psi, and 2.5 N and 47 N, respectively. The mechanical failure and leakage performance of the TCS were different for homogeneous and composite TCSs. The test methods reported in this study\u00a0may facilitate the development and regulatory review of these devices, may help compare TCS performance between devices, and increase provider and patient accessibility to improved tissue containment technologies.<\/jats:p>","DOI":"10.1038\/s41598-023-31847-7","type":"journal-article","created":{"date-parts":[[2023,3,29]],"date-time":"2023-03-29T10:02:54Z","timestamp":1680084174000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Mechanical and leakage integrity testing considerations for evaluating the performance of tissue containment systems"],"prefix":"10.1038","volume":"13","author":[{"given":"Alexander","family":"Herman","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nandini","family":"Duraiswamy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Poulomi","family":"Nandy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Veronica","family":"Price","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"George","family":"Gibeily","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Prasanna","family":"Hariharan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,3,29]]},"reference":[{"key":"31847_CR1","doi-asserted-by":"crossref","unstructured":"Multinu, F. et al. practice patterns and complications of benign hysterectomy following the FDA statement warning against the use of power morcellation. JAMA Surg. 153(6), e180141 (2018).","DOI":"10.1001\/jamasurg.2018.0141"},{"key":"31847_CR2","first-page":"176","volume":"114","author":"B Winner","year":"2017","unstructured":"Winner, B. & Biest, S. Uterine morcellation: Fact and fiction surrounding the recent controversy. Mo. Med. 114, 176\u2013180 (2017).","journal-title":"Mo. Med."},{"key":"31847_CR3","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1016\/j.jmig.2019.04.031","volume":"27","author":"S Zaami","year":"2020","unstructured":"Zaami, S. et al. Medicolegal issues in power morcellation: cautionary rules for gynecologists to avoid unfavorable outcomes. J. Minim. Invasive Gynecol. 27, 583\u2013592 (2020).","journal-title":"J. Minim. Invasive Gynecol."},{"key":"31847_CR4","unstructured":"US Food and Drug Administration. UPDATED laparoscopic uterine power morcellation in hysterectomy and myomectomy: FDA safety communication. (Silver Spring, MD, 2014)."},{"key":"31847_CR5","unstructured":"US Government Accountability Office. MEDICAL DEVICES: Cancer risk led FDA to warn against certain uses of power morcellators and recommend new labeling. pp 49 (US Government Accountability Office, Washington, DC, 2017)."},{"key":"31847_CR6","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1016\/j.jmig.2018.03.010","volume":"25","author":"TETF Members","year":"2018","unstructured":"Tissue Extraction Task Force Members. Morcellation during uterine tissue extraction: An update. J. Minim. Invasive Gynecol. 25, 543\u2013550 (2018).","journal-title":"J. Minim. Invasive Gynecol."},{"key":"31847_CR7","doi-asserted-by":"publisher","first-page":"787","DOI":"10.1097\/AOG.0000000000000448","volume":"124","author":"KA Kho","year":"2014","unstructured":"Kho, K. A., Anderson, T. L. & Nezhat, C. H. Intracorporeal electromechanical tissue morcellation: A critical review and recommendations for clinical practice. Obstet. Gynecol. 124, 787\u2013793 (2014).","journal-title":"Obstet. Gynecol."},{"key":"31847_CR8","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.ijsu.2018.12.013","volume":"62","author":"R Devassy","year":"2019","unstructured":"Devassy, R. et al. Feasibility of myomatous tissue extraction in laparoscopic surgery by contained in-bag morcellation: A retrospective single arm study. Int. J. Surg. 62, 22\u201327 (2019).","journal-title":"Int. J. Surg."},{"key":"31847_CR9","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1016\/j.ajog.2014.07.046","volume":"212","author":"S Senapati","year":"2015","unstructured":"Senapati, S., Tu, F. F. & Magrina, J. F. Power morcellators: A review of current practice and assessment of risk. Am. J. Obstet. Gynecol 212, 18\u201323 (2015).","journal-title":"Am. J. Obstet. Gynecol"},{"key":"31847_CR10","doi-asserted-by":"publisher","first-page":"15","DOI":"10.3389\/fsurg.2017.00015","volume":"4","author":"E Taylan","year":"2017","unstructured":"Taylan, E., Sahin, C., Zeybek, B. & Akdemir, A. Contained morcellation: Review of current methods and future directions. Front Surg. 4, 15 (2017).","journal-title":"Front Surg."},{"key":"31847_CR11","doi-asserted-by":"publisher","first-page":"834","DOI":"10.1097\/AOG.0000000000001039","volume":"126","author":"B Winner","year":"2015","unstructured":"Winner, B., Porter, A., Velloze, S. & Biest, S. Uncontained compared with contained power morcellation in total laparoscopic hysterectomy. Obstet. Gynecol. 126, 834\u2013838 (2015).","journal-title":"Obstet. Gynecol."},{"key":"31847_CR12","unstructured":"US Food and Drug Administration. FDA allows marketing of first-of-kind tissue containment system for use with certain laparoscopic power morcellators in select patients. (Silver Spring, MD, 2016)."},{"key":"31847_CR13","unstructured":"US Food and Drug Administration. Evaluation of Automatic Class III Designation\u2014De Novo Request for DEN150028. in (CDRH) U.S. Food and Drug Administration,  pp 5 (Silver Spring, MD, 2016)."},{"key":"31847_CR14","unstructured":"US Food and Drug Administration. Evaluation of Automatic Class III Designation\u2014De Novo Request for DEN170075. in (CDRH) U.S. Food and Drug Administration,  pp 5 (Silver Spring, MD, 2017)."},{"key":"31847_CR15","unstructured":"US Food and Drug Administration. Premarket Notification Summary for More-Cell-System. in (CDRH) U.S. Food and Drug Administration,  pp 11 (Silver Spring, MD, 2021)."},{"key":"31847_CR16","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1080\/13645706.2016.1176932","volume":"25","author":"M Anapolski","year":"2016","unstructured":"Anapolski, M. et al. Power morcellation inside a secure endobag: A pilot study. Minim. Invasive Ther. Allied Technol. 25, 203\u2013209 (2016).","journal-title":"Minim. Invasive Ther. Allied Technol."},{"key":"31847_CR17","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.ejogrb.2016.04.012","volume":"201","author":"Y Aoki","year":"2016","unstructured":"Aoki, Y., Matsuura, M., Matsuno, T. & Yamamoto, T. Single-site in-bag morcellation achieved via direct puncture of the pneumoperitoneum cap, a cordless electric morcellator, and a 5-mm flexible scope. Eur. J. Obstet. Gynecol. Reprod. Biol. 201, 126\u2013130 (2016).","journal-title":"Eur. J. Obstet. Gynecol. Reprod. Biol."},{"key":"31847_CR18","doi-asserted-by":"publisher","first-page":"160","DOI":"10.1016\/j.jmig.2014.10.012","volume":"22","author":"A Cholkeri-Singh","year":"2015","unstructured":"Cholkeri-Singh, A. & Miller, C. E. Power morcellation in a specimen bag. J. Minim. Invasive Gynecol. 22, 160 (2015).","journal-title":"J. Minim. Invasive Gynecol."},{"key":"31847_CR19","doi-asserted-by":"publisher","first-page":"251","DOI":"10.1016\/j.jmig.2017.07.030","volume":"25","author":"NV Clark","year":"2018","unstructured":"Clark, N. V. & Cohen, S. L. Tissue extraction techniques during laparoscopic uterine surgery. J. Minim. Invasive Gynecol. 25, 251\u2013256 (2018).","journal-title":"J. Minim. Invasive Gynecol."},{"key":"31847_CR20","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1016\/j.jmig.2018.07.020","volume":"26","author":"SL Cohen","year":"2019","unstructured":"Cohen, S. L. et al. Prospective evaluation of manual morcellation techniques: minilaparotomy versus vaginal approach. J. Minim. Invasive Gynecol. 26, 702\u2013708 (2019).","journal-title":"J. Minim. Invasive Gynecol."},{"key":"31847_CR21","doi-asserted-by":"publisher","first-page":"257.e251","DOI":"10.1016\/j.ajog.2015.08.076","volume":"214","author":"SL Cohen","year":"2016","unstructured":"Cohen, S. L. et al. Contained tissue extraction using power morcellation: Prospective evaluation of leakage parameters. Am. J. Obstet. Gynecol. 214, 257.e251-e256 (2016).","journal-title":"Am. J. Obstet. Gynecol."},{"key":"31847_CR22","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1016\/j.jmig.2014.04.010","volume":"21","author":"JI Einarsson","year":"2014","unstructured":"Einarsson, J. I., Cohen, S. L., Fuchs, N. & Wang, K. C. In-bag morcellation. J. Minim. Invasive Gynecol. 21, 951\u2013953 (2014).","journal-title":"J. Minim. Invasive Gynecol."},{"key":"31847_CR23","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1016\/j.jmig.2016.03.024","volume":"23","author":"DE Ikhena","year":"2016","unstructured":"Ikhena, D. E., Paintal, A. & Milad, M. P. Feasibility of washings at the time of laparoscopic power morcellation: A pilot study. J. Minim. Invasive Gynecol. 23, 793\u2013797 (2016).","journal-title":"J. Minim. Invasive Gynecol."},{"key":"31847_CR24","doi-asserted-by":"crossref","unstructured":"Lambat Emery, S. et al. Cell spillage after contained electromechanical morcellation using a specially designed in-bag system for laparoscopic myomectomy: A prospective cohort pilot study. J. Minim. Invasive Gynecol. 26(7), 1351\u20131356 (2019).","DOI":"10.1016\/j.jmig.2019.01.014"},{"key":"31847_CR25","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1097\/GCO.0000000000000435","volume":"30","author":"CE Miller","year":"2018","unstructured":"Miller, C. E. Morcellation equipment: Past, present, and future. Curr. Opin. Obstet. Gynecol. 30, 69\u201374 (2018).","journal-title":"Curr. Opin. Obstet. Gynecol."},{"key":"31847_CR26","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/j.jmig.2015.08.004","volume":"23","author":"PG Paul","year":"2016","unstructured":"Paul, P. G., Thomas, M., Das, T., Patil, S. & Garg, R. Contained morcellation for laparoscopic myomectomy within a specially designed bag. J. Minim. Invasive Gynecol. 23, 257\u2013260 (2016).","journal-title":"J. Minim. Invasive Gynecol."},{"key":"31847_CR27","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1007\/s00404-015-3986-5","volume":"294","author":"S Rimbach","year":"2016","unstructured":"Rimbach, S., Holzknecht, A., Schmedler, C., Nemes, C. & Offner, F. First clinical experiences using a new in-bag morcellation system during laparoscopic hysterectomy. Arch. Gynecol. Obstet. 294, 83\u201393 (2016).","journal-title":"Arch. Gynecol. Obstet."},{"key":"31847_CR28","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.1097\/AOG.0000000000002334","volume":"130","author":"MT Siedhoff","year":"2017","unstructured":"Siedhoff, M. T. & Cohen, S. L. Tissue extraction techniques for leiomyomas and uteri during minimally invasive surgery. Obstet. Gynecol. 130, 1251\u20131260 (2017).","journal-title":"Obstet. Gynecol."},{"key":"31847_CR29","doi-asserted-by":"publisher","first-page":"1244","DOI":"10.1016\/j.jmig.2015.07.007","volume":"22","author":"E Solima","year":"2015","unstructured":"Solima, E. et al. Vaginal uterine morcellation within a specimen containment system: A study of bag integrity. J. Minim. Invasive Gynecol. 22, 1244\u20131246 (2015).","journal-title":"J. Minim. Invasive Gynecol."},{"key":"31847_CR30","doi-asserted-by":"crossref","unstructured":"Steller, C., Cholkeri-Singh, A., Sasaki, K. & Miller, C. E. Power morcellation using a contained bag system. JSLS 21(1), e2016.00095 (2017).","DOI":"10.4293\/JSLS.2016.00095"},{"key":"31847_CR31","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.jmig.2014.11.010","volume":"22","author":"MV Vargas","year":"2015","unstructured":"Vargas, M. V. et al. Open power morcellation versus contained power morcellation within an insufflated isolation bag: Comparison of perioperative outcomes. J. Minim. Invasive Gynecol. 22, 433\u2013438 (2015).","journal-title":"J. Minim. Invasive Gynecol."},{"key":"31847_CR32","doi-asserted-by":"publisher","first-page":"1369","DOI":"10.1016\/j.fertnstert.2015.12.133","volume":"105","author":"R Venturella","year":"2016","unstructured":"Venturella, R. et al. In-bag manual versus uncontained power morcellation for laparoscopic myomectomy: Randomized controlled trial. Fertil. Steril. 105, 1369\u20131376 (2016).","journal-title":"Fertil. Steril."},{"key":"31847_CR33","unstructured":"US Food and Drug Administration. Denovo Classification Request For Pneumoliner. in (CDRH) U.S. Food and Drug Administration, pp 19 (Silver Spring, MD, 2016)."},{"key":"31847_CR34","unstructured":"US Food and Drug Administration. Denovo Classification Request For ContainOR. in (CDRH) U.S. Food and Drug Administration, pp 18 (Silver Spring, MD, 2017)."},{"key":"31847_CR35","doi-asserted-by":"publisher","first-page":"494","DOI":"10.1007\/s00464-016-4969-8","volume":"31","author":"M Anapolski","year":"2017","unstructured":"Anapolski, M. et al. Preclinical safety testing for morcellation and extraction for an endobag with sealable ports: In vitro pilot study. Surg. Endosc. 31, 494\u2013500 (2017).","journal-title":"Surg. Endosc."},{"key":"31847_CR36","doi-asserted-by":"publisher","first-page":"935","DOI":"10.1016\/j.jmig.2014.06.004","volume":"21","author":"SL Cohen","year":"2014","unstructured":"Cohen, S. L. et al. Risk of leakage and tissue dissemination with various contained tissue extraction (CTE) techniques: An in vitro pilot study. J. Minim. Invasive Gynecol. 21, 935\u2013939 (2014).","journal-title":"J. Minim. Invasive Gynecol."},{"key":"31847_CR37","doi-asserted-by":"publisher","first-page":"1311","DOI":"10.1007\/s00404-015-3788-9","volume":"292","author":"S Rimbach","year":"2015","unstructured":"Rimbach, S., Holzknecht, A., Nemes, C., Offner, F. & Craina, M. A new in-bag system to reduce the risk of tissue morcellation: Development and experimental evaluation during laparoscopic hysterectomy. Arch. Gynecol. Obstet. 292, 1311\u20131320 (2015).","journal-title":"Arch. Gynecol. Obstet."},{"key":"31847_CR38","doi-asserted-by":"crossref","unstructured":"van den Haak, L. et al. Towards spill-free in-bag morcellation: A health failure mode and effects analysis. Surg. Endosc. 32(10), 4357\u20134362 (2018).","DOI":"10.1007\/s00464-018-6284-z"},{"key":"31847_CR39","volume-title":"Standard Test Method for Tensile Properties of Thin Plastic Sheeting","author":"ASTM","year":"2012","unstructured":"ASTM. Standard Test Method for Tensile Properties of Thin Plastic Sheeting (ASTM, 2012)."},{"key":"31847_CR40","volume-title":"Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Liquids","author":"ASTM","year":"2010","unstructured":"ASTM. Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Liquids (ASTM, 2010)."},{"key":"31847_CR41","volume-title":"Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Synthetic Blood","author":"ASTM","year":"2008","unstructured":"ASTM. Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Synthetic Blood (ASTM, 2008)."},{"key":"31847_CR42","volume-title":"Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174 Bacteriophage Penetration as a Test System","author":"ASTM","year":"2013","unstructured":"ASTM. Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174 Bacteriophage Penetration as a Test System (ASTM, 2013)."},{"key":"31847_CR43","volume-title":"Standard Test Method for Protective Clothing Material Resistance to Puncture","author":"ASTM","year":"2013","unstructured":"ASTM. Standard Test Method for Protective Clothing Material Resistance to Puncture (ASTM, 2013)."},{"key":"31847_CR44","volume-title":"Standard Test Method for Rubber Property\u2014Durometer Hardness","author":"ASTM","year":"2015","unstructured":"ASTM. Standard Test Method for Rubber Property\u2014Durometer Hardness (ASTM, 2015)."},{"key":"31847_CR45","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1016\/j.jmig.2019.05.006","volume":"27","author":"A Herman","year":"2019","unstructured":"Herman, A. et al. In vitro leakage testing of tissue containment bags when subjected to power morcellation forces. J. Minim. Invasive Gynecol. 27, 655\u2013664 (2019).","journal-title":"J. Minim. Invasive Gynecol."},{"key":"31847_CR46","unstructured":"US Food and Drug Administration. Gynecologic laparoscopic power morcellation containment system. in (CFR Regulation) 21, Government Printing Office, pp 1 (Silver Spring, MD, 2016)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-31847-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-31847-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-31847-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,29]],"date-time":"2023-03-29T10:12:09Z","timestamp":1680084729000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-31847-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,29]]},"references-count":46,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["31847"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-31847-7","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,29]]},"assertion":[{"value":"13 September 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 March 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"5104"}}