{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T23:39:37Z","timestamp":1794267577538,"version":"4.9.0"},"reference-count":101,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,6,2]],"date-time":"2023-06-02T00:00:00Z","timestamp":1685664000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,6,2]],"date-time":"2023-06-02T00:00:00Z","timestamp":1685664000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002790","name":"Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","award":["Discovery Grant (RGPIN-2017-05349)"],"award-info":[{"award-number":["Discovery Grant (RGPIN-2017-05349)"]}],"id":[{"id":"10.13039\/501100002790","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>In recent years, transcatheter aortic valve replacement (TAVR) has become the leading method for treating aortic stenosis. While the procedure has improved dramatically in the past decade, there are still uncertainties about the impact of TAVR on coronary blood flow. Recent research has indicated that negative coronary events after TAVR may be partially driven by impaired coronary blood flow dynamics. Furthermore, the current technologies to rapidly obtain non-invasive coronary blood flow data are relatively limited. Herein, we present a lumped parameter computational model to simulate coronary blood flow in the main arteries as well as a series of cardiovascular hemodynamic metrics. The model was designed to only use a few inputs parameters from echocardiography, computed tomography and a sphygmomanometer. The novel computational model was then validated and applied to 19 patients undergoing TAVR to examine the impact of the procedure on coronary blood flow in the left anterior descending (LAD) artery, left circumflex (LCX) artery and right coronary artery (RCA<jats:italic>)<\/jats:italic> and various global hemodynamics metrics. Based on our findings, the changes in coronary blood flow after TAVR varied and were subject specific (37% had increased flow in all three coronary arteries, 32% had decreased flow in all coronary arteries, and 31% had both increased and decreased flow in different coronary arteries). Additionally, valvular pressure gradient, left ventricle (LV) workload and maximum LV pressure decreased by 61.5%, 4.5% and 13.0% respectively, while mean arterial pressure and cardiac output increased by 6.9% and 9.9% after TAVR. By applying this proof-of-concept computational model, a series of hemodynamic metrics were generated non-invasively which can help to better understand the individual relationships between TAVR and mean and peak coronary flow rates. In the future, tools such as these may play a vital role by providing clinicians with rapid insight into various cardiac and coronary metrics, rendering the planning for TAVR and other cardiovascular procedures more personalized.<\/jats:p>","DOI":"10.1038\/s41598-023-31987-w","type":"journal-article","created":{"date-parts":[[2023,6,2]],"date-time":"2023-06-02T10:05:33Z","timestamp":1685700333000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":20,"title":["Impact of TAVR on coronary artery hemodynamics using clinical measurements and image\u2010based patient\u2010specific in silico modeling"],"prefix":"10.1038","volume":"13","author":[{"given":"Louis","family":"Garber","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seyedvahid","family":"Khodaei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nima","family":"Maftoon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zahra","family":"Keshavarz-Motamed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,6,2]]},"reference":[{"key":"31987_CR1","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1161\/CIRCRESAHA.114.302292","volume":"114","author":"CV Bourantas","year":"2014","unstructured":"Bourantas, C. V. & Serruys, P. W. Evolution of transcatheter aortic valve replacement. Circ. Res. 114, 1037\u20131051 (2014).","journal-title":"Circ. Res."},{"key":"31987_CR2","doi-asserted-by":"publisher","first-page":"2492","DOI":"10.1016\/j.jacc.2020.09.595","volume":"76","author":"JD Carroll","year":"2020","unstructured":"Carroll, J. D. et al. STS-ACC TVT registry of transcatheter aortic valve replacement. J. Am. Coll. Cardiol. 76, 2492\u20132516 (2020).","journal-title":"J. Am. Coll. Cardiol."},{"key":"31987_CR3","doi-asserted-by":"publisher","first-page":"e004947","DOI":"10.1161\/CIRCOUTCOMES.118.004947","volume":"11","author":"G Elbaz-Greener","year":"2018","unstructured":"Elbaz-Greener, G. et al. Profiling hospital performance based on mortality after transcatheter aortic valve replacement in Ontario, Canada. Circ. Cardiovasc. Qual. Outcomes 11, e004947 (2018).","journal-title":"Circ. Cardiovasc. Qual. Outcomes"},{"key":"31987_CR4","doi-asserted-by":"publisher","first-page":"5046","DOI":"10.3390\/jcm10215046","volume":"10","author":"M Mach","year":"2021","unstructured":"Mach, M. et al. Vascular complications in TAVR: Incidence, clinical impact, and management. J. Clin. Med. 10, 5046 (2021).","journal-title":"J. Clin. Med."},{"key":"31987_CR5","doi-asserted-by":"publisher","first-page":"452","DOI":"10.1016\/j.jcin.2012.11.014","volume":"6","author":"HB Ribeiro","year":"2013","unstructured":"Ribeiro, H. B. et al. Coronary obstruction following transcatheter aortic valve implantation. JACC Cardiovasc. Interv. 6, 452\u2013461 (2013).","journal-title":"JACC Cardiovasc. Interv."},{"key":"31987_CR6","doi-asserted-by":"publisher","first-page":"938","DOI":"10.1016\/j.jcin.2019.11.027","volume":"13","author":"A Mentias","year":"2020","unstructured":"Mentias, A. et al. Incidence and outcomes of acute coronary syndrome after transcatheter aortic valve replacement. JACC Cardiovasc. Interv. 13, 938\u2013950 (2020).","journal-title":"JACC Cardiovasc. Interv."},{"key":"31987_CR7","doi-asserted-by":"publisher","first-page":"104","DOI":"10.3389\/fcvm.2018.00104","volume":"5","author":"G Armijo","year":"2018","unstructured":"Armijo, G., Nombela-Franco, L. & Tirado-Conte, G. Cerebrovascular events after transcatheter aortic valve implantation. Front. Cardiovasc. Med. 5, 104 (2018).","journal-title":"Front. Cardiovasc. Med."},{"key":"31987_CR8","doi-asserted-by":"publisher","first-page":"1797","DOI":"10.1136\/heartjnl-2017-312454","volume":"104","author":"M Eleid","year":"2018","unstructured":"Eleid, M. Interventional management of paravalvular leak. Heart 104, 1797\u20131802 (2018).","journal-title":"Heart"},{"key":"31987_CR9","doi-asserted-by":"publisher","first-page":"e018978","DOI":"10.1161\/JAHA.120.018978","volume":"10","author":"DR Feldman","year":"2021","unstructured":"Feldman, D. R. et al. Comorbidity burden and adverse outcomes after transcatheter aortic valve replacement. J. Am. Heart Assoc. 10, e018978 (2021).","journal-title":"J. Am. Heart Assoc."},{"key":"31987_CR10","doi-asserted-by":"publisher","first-page":"1419","DOI":"10.1586\/14779072.2015.1102056","volume":"13","author":"CJ O\u2019Sullivan","year":"2015","unstructured":"O\u2019Sullivan, C. J. & Wenaweser, P. Optimizing clinical outcomes of transcatheter aortic valve implantation patients with comorbidities. Expert Rev. Cardiovasc. Ther. 13, 1419\u20131432 (2015).","journal-title":"Expert Rev. Cardiovasc. Ther."},{"key":"31987_CR11","doi-asserted-by":"publisher","first-page":"e558","DOI":"10.1161\/CIR.0000000000000570","volume":"137","author":"SB Dunbar","year":"2018","unstructured":"Dunbar, S. B. et al. Projected costs of informal caregiving for cardiovascular disease: 2015 to 2035: A policy statement from the American Heart Association. Circulation 137, e558\u2013e577 (2018).","journal-title":"Circulation"},{"key":"31987_CR12","unstructured":"Cardiovascular diseases (CVDs). https:\/\/www.who.int\/news-room\/fact-sheets\/detail\/cardiovascular-diseases-(cvds)."},{"key":"31987_CR13","doi-asserted-by":"publisher","first-page":"e016446","DOI":"10.1161\/JAHA.120.016446","volume":"9","author":"L Nai Fovino","year":"2020","unstructured":"Nai Fovino, L. et al. Coronary angiography after transcatheter aortic valve replacement (TAVR) to evaluate the risk of coronary access impairment after TAVR-in-TAVR. J. Am. Heart Assoc. 9, e016446 (2020).","journal-title":"J. Am. Heart Assoc."},{"key":"31987_CR14","doi-asserted-by":"publisher","first-page":"2539","DOI":"10.1016\/j.jcin.2020.06.065","volume":"13","author":"G Tarantini","year":"2020","unstructured":"Tarantini, G. & Nai Fovino, L. Coronary access and TAVR-in-TAVR. JACC Cardiovasc. Interv. 13, 2539\u20132541 (2020).","journal-title":"JACC Cardiovasc. Interv."},{"key":"31987_CR15","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1109\/RBME.2022.3142058","volume":"16","author":"M Kadem","year":"2023","unstructured":"Kadem, M., Garber, L., Abdelkhalek, M., Al-Khazraji, B. K. & Keshavarz-Motamed, Z. Hemodynamic modeling, medical imaging, and machine learning and their applications to cardiovascular interventions. IEEE Rev. Biomed. Eng. 16, 403\u2013423 (2023).","journal-title":"IEEE Rev. Biomed. Eng."},{"key":"31987_CR16","doi-asserted-by":"publisher","first-page":"2444","DOI":"10.1093\/eurheartj\/ehy670","volume":"40","author":"PD Adamson","year":"2019","unstructured":"Adamson, P. D. & Newby, D. E. Non-invasive imaging of the coronary arteries. Eur. Heart J. 40, 2444\u20132454 (2019).","journal-title":"Eur. Heart J."},{"key":"31987_CR17","doi-asserted-by":"publisher","first-page":"2278","DOI":"10.1016\/j.jacc.2019.08.1046","volume":"74","author":"Q Ciampi","year":"2019","unstructured":"Ciampi, Q. et al. Functional, anatomical, and prognostic correlates of coronary flow velocity reserve during stress echocardiography. J. Am. Coll. Cardiol. 74, 2278\u20132291 (2019).","journal-title":"J. Am. Coll. Cardiol."},{"key":"31987_CR18","doi-asserted-by":"publisher","first-page":"725833","DOI":"10.3389\/fbioe.2021.725833","volume":"9","author":"CPS Blanken","year":"2021","unstructured":"Blanken, C. P. S. et al. Coronary flow assessment using accelerated 4D flow MRI with respiratory motion correction. Front. Bioeng. Biotechnol. 9, 725833 (2021).","journal-title":"Front. Bioeng. Biotechnol."},{"key":"31987_CR19","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1016\/j.jacc.2019.06.012","volume":"74","author":"L Faroux","year":"2019","unstructured":"Faroux, L. et al. Coronary artery disease and transcatheter aortic valve replacement. J. Am. Coll. Cardiol. 74, 362\u2013372 (2019).","journal-title":"J. Am. Coll. Cardiol."},{"key":"31987_CR20","doi-asserted-by":"publisher","unstructured":"Abdelkhalek, M. et al. Patterns and Structure of Calcification in Aortic Stenosis: An Approach on Contrast-Enhanced CT Images. JACC: Cardiovasc. Imag. https:\/\/doi.org\/10.1016\/j.jcmg.2023.02.011 (2023).","DOI":"10.1016\/j.jcmg.2023.02.011"},{"key":"31987_CR21","doi-asserted-by":"publisher","unstructured":"Keshavarz-Motamed, Z., Garcia, J. & Kadem, L. Fluid Dynamics of Coarctation of the Aorta and Effect of Bicuspid Aortic Valve. PLOS ONE 8(8), e72394. https:\/\/doi.org\/10.1371\/journal.pone.0072394 (2013).","DOI":"10.1371\/journal.pone.0072394"},{"key":"31987_CR22","doi-asserted-by":"publisher","first-page":"10888","DOI":"10.1038\/s41598-021-85500-2","volume":"11","author":"S Khodaei","year":"2021","unstructured":"Khodaei, S. et al. Personalized intervention cardiology with transcatheter aortic valve replacement made possible with a non-invasive monitoring and diagnostic framework. Sci. Rep. 11, 10888 (2021).","journal-title":"Sci. Rep."},{"key":"31987_CR23","doi-asserted-by":"publisher","first-page":"106506","DOI":"10.1016\/j.ijmecsci.2021.106506","volume":"202\u2013203","author":"S Khodaei","year":"2021","unstructured":"Khodaei, S. et al. Towards a non-invasive computational diagnostic framework for personalized cardiology of transcatheter aortic valve replacement in interactions with complex valvular, ventricular and vascular disease. Int. J. Mech. Sci. 202\u2013203, 106506 (2021).","journal-title":"Int. J. Mech. Sci."},{"key":"31987_CR24","doi-asserted-by":"publisher","first-page":"603040","DOI":"10.3389\/fphys.2021.603040","volume":"12","author":"J Primeaux","year":"2021","unstructured":"Primeaux, J., Salavitabar, A., Lu, J. C., Grifka, R. G. & Figueroa, C. A. Characterization of post-operative hemodynamics following the norwood procedure using population data and multi-scale modeling. Front. Physiol. 12, 603040 (2021).","journal-title":"Front. Physiol."},{"key":"31987_CR25","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1007\/s13239-018-00396-w","volume":"10","author":"A Ceballos","year":"2019","unstructured":"Ceballos, A., Prather, R., Divo, E., Kassab, A. J. & DeCampli, W. M. Patient-specific multi-scale model analysis of hemodynamics following the hybrid norwood procedure for hypoplastic left heart syndrome: Effects of reverse Blalock-Taussig shunt diameter. Cardiovasc. Eng. Technol. 10, 136\u2013154 (2019).","journal-title":"Cardiovasc. Eng. Technol."},{"key":"31987_CR26","doi-asserted-by":"publisher","first-page":"8145","DOI":"10.1038\/s41598-021-86360-6","volume":"11","author":"M Vardhan","year":"2021","unstructured":"Vardhan, M. et al. Non-invasive characterization of complex coronary lesions. Sci. Rep. 11, 8145 (2021).","journal-title":"Sci. Rep."},{"key":"31987_CR27","doi-asserted-by":"publisher","first-page":"2606","DOI":"10.1007\/s10439-021-02829-5","volume":"49","author":"V Mazzi","year":"2021","unstructured":"Mazzi, V. et al. Early atherosclerotic changes in coronary arteries are associated with endothelium shear stress contraction\/expansion variability. Ann. Biomed. Eng. 49, 2606\u20132621 (2021).","journal-title":"Ann. Biomed. Eng."},{"key":"31987_CR28","doi-asserted-by":"publisher","first-page":"18","DOI":"10.1136\/heartjnl-2015-308044","volume":"102","author":"PD Morris","year":"2016","unstructured":"Morris, P. D. et al. Computational fluid dynamics modelling in cardiovascular medicine. Heart 102, 18\u201328 (2016).","journal-title":"Heart"},{"key":"31987_CR29","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1016\/j.jcp.2015.11.022","volume":"305","author":"R Mittal","year":"2016","unstructured":"Mittal, R. et al. Computational modeling of cardiac hemodynamics: Current status and future outlook. J. Comput. Phys. 305, 1065\u20131082 (2016).","journal-title":"J. Comput. Phys."},{"key":"31987_CR30","doi-asserted-by":"publisher","first-page":"e015063","DOI":"10.1161\/JAHA.119.015063","volume":"9","author":"Z Keshavarz-Motamed","year":"2020","unstructured":"Keshavarz-Motamed, Z. et al. Mixed valvular disease following transcatheter aortic valve replacement: Quantification and systematic differentiation using clinical measurements and image-based patient-specific in silico modeling. J. Am. Heart Assoc. 9, e015063 (2020).","journal-title":"J. Am. Heart Assoc."},{"key":"31987_CR31","doi-asserted-by":"publisher","first-page":"eaaw0181","DOI":"10.1126\/scitranslmed.aaw0181","volume":"11","author":"E Ben-Assa","year":"2019","unstructured":"Ben-Assa, E. et al. Ventricular stroke work and vascular impedance refine the characterization of patients with aortic stenosis. Sci. Transl. Med. 11, eaaw0181 (2019).","journal-title":"Sci. Transl. Med."},{"key":"31987_CR32","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1007\/s10439-016-1762-8","volume":"45","author":"A Updegrove","year":"2017","unstructured":"Updegrove, A. et al. SimVascular: An open source pipeline for cardiovascular simulation. Ann. Biomed. Eng. 45, 525\u2013541 (2017).","journal-title":"Ann. Biomed. Eng."},{"key":"31987_CR33","doi-asserted-by":"publisher","first-page":"e1008881","DOI":"10.1371\/journal.pcbi.1008881","volume":"17","author":"CJ Arthurs","year":"2021","unstructured":"Arthurs, C. J. et al. CRIMSON: An open-source software framework for cardiovascular integrated modelling and simulation. PLOS Comput. Biol. 17, e1008881 (2021).","journal-title":"PLOS Comput. Biol."},{"key":"31987_CR34","doi-asserted-by":"publisher","first-page":"2233","DOI":"10.1016\/j.jacc.2012.11.083","volume":"61","author":"CA Taylor","year":"2013","unstructured":"Taylor, C. A., Fonte, T. A. & Min, J. K. Computational fluid dynamics applied to cardiac computed tomography for noninvasive quantification of fractional flow reserve. J. Am. Coll. Cardiol. 61, 2233\u20132241 (2013).","journal-title":"J. Am. Coll. Cardiol."},{"key":"31987_CR35","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1016\/j.jacc.2018.10.056","volume":"73","author":"RS Driessen","year":"2019","unstructured":"Driessen, R. S. et al. Comparison of coronary computed tomography angiography, fractional flow reserve, and perfusion imaging for ischemia diagnosis. J. Am. Coll. Cardiol. 73, 161\u2013173 (2019).","journal-title":"J. Am. Coll. Cardiol."},{"key":"31987_CR36","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1007\/s12265-018-9787-z","volume":"11","author":"JW Holmes","year":"2018","unstructured":"Holmes, J. W. & Lumens, J. Clinical applications of patient-specific models: The case for a simple approach. J Cardiovasc. Transl. Res. 11, 71\u201379 (2018).","journal-title":"J Cardiovasc. Transl. Res."},{"key":"31987_CR37","doi-asserted-by":"publisher","DOI":"10.1007\/s11831-021-09685-5","author":"L Garber","year":"2021","unstructured":"Garber, L., Khodaei, S. & Keshavarz-Motamed, Z. The critical role of lumped parameter models in patient-specific cardiovascular simulations. Arch. Comput. Methods Eng. https:\/\/doi.org\/10.1007\/s11831-021-09685-5 (2021).","journal-title":"Arch. Comput. Methods Eng."},{"issue":"105","key":"31987_CR38","doi-asserted-by":"publisher","first-page":"1916","DOI":"10.1152\/japplphysiol.90572.2008","volume":"1985","author":"D Tann\u00e9","year":"2008","unstructured":"Tann\u00e9, D., Kadem, L., Rieu, R. & Pibarot, P. Hemodynamic impact of mitral prosthesis-patient mismatch on pulmonary hypertension: An in silico study. J. Appl. Physiol. 1985(105), 1916\u20131926 (2008).","journal-title":"J. Appl. Physiol."},{"key":"31987_CR39","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1002\/cnm.1466","volume":"28","author":"JP Mynard","year":"2012","unstructured":"Mynard, J. P., Davidson, M. R., Penny, D. J. & Smolich, J. J. A simple, versatile valve model for use in lumped parameter and one-dimensional cardiovascular models. Int. J. Numer. Methods Biomed. Eng. 28, 626\u2013641 (2012).","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"key":"31987_CR40","doi-asserted-by":"publisher","first-page":"H2050","DOI":"10.1152\/ajpheart.1996.270.6.H2050","volume":"270","author":"N Stergiopulos","year":"1996","unstructured":"Stergiopulos, N., Meister, J. J. & Westerhof, N. Determinants of stroke volume and systolic and diastolic aortic pressure. Am. J. Physiol. Heart Circ. Physiol. 270, H2050\u2013H2059 (1996).","journal-title":"Am. J. Physiol. Heart Circ. Physiol."},{"key":"31987_CR41","doi-asserted-by":"publisher","first-page":"6905","DOI":"10.1038\/s41598-020-63728-8","volume":"10","author":"Z Keshavarz-Motamed","year":"2020","unstructured":"Keshavarz-Motamed, Z. A diagnostic, monitoring, and predictive tool for patients with complex valvular, vascular and ventricular diseases. Sci. Rep. 10, 6905 (2020).","journal-title":"Sci. Rep."},{"key":"31987_CR42","doi-asserted-by":"publisher","first-page":"2817","DOI":"10.1016\/j.jbiomech.2011.08.001","volume":"44","author":"Z Keshavarz-Motamed","year":"2011","unstructured":"Keshavarz-Motamed, Z., Garcia, J., Pibarot, P., Larose, E. & Kadem, L. Modeling the impact of concomitant aortic stenosis and coarctation of the aorta on left ventricular workload. J. Biomech. 44, 2817\u20132825 (2011).","journal-title":"J. Biomech."},{"key":"31987_CR43","doi-asserted-by":"publisher","first-page":"4229","DOI":"10.1016\/j.jbiomech.2015.10.017","volume":"48","author":"Z Keshavarz-Motamed","year":"2015","unstructured":"Keshavarz-Motamed, Z., Edelman, E. R., Garcia, J., Dahdah, N. & Kadem, L. The role of aortic compliance in determination of coarctation severity: Lumped parameter modeling, in vitro study and clinical evaluation. J. Biomech. 48, 4229\u20134237 (2015).","journal-title":"J. Biomech."},{"key":"31987_CR44","doi-asserted-by":"publisher","first-page":"1696","DOI":"10.1007\/s00348-014-1696-6","volume":"55","author":"Z Keshavarz-Motamed","year":"2014","unstructured":"Keshavarz-Motamed, Z. et al. Effect of coarctation of the aorta and bicuspid aortic valve on flow dynamics and turbulence in the aorta using particle image velocimetry. Exp. Fluids 55, 1696 (2014).","journal-title":"Exp. Fluids"},{"key":"31987_CR45","doi-asserted-by":"publisher","first-page":"1239","DOI":"10.1016\/j.jbiomech.2012.01.039","volume":"45","author":"Z Keshavarz-Motamed","year":"2012","unstructured":"Keshavarz-Motamed, Z. et al. A new approach for the evaluation of the severity of coarctation of the aorta using Doppler velocity index and effective orifice area: In vitro validation and clinical implications. J. Biomech. 45, 1239\u20131245 (2012).","journal-title":"J. Biomech."},{"key":"31987_CR46","doi-asserted-by":"publisher","first-page":"e0123000","DOI":"10.1371\/journal.pone.0123000","volume":"10","author":"E Benevento","year":"2015","unstructured":"Benevento, E., Djebbari, A., Keshavarz-Motamed, Z., Cecere, R. & Kadem, L. Hemodynamic changes following aortic valve bypass: A mathematical approach. PLoS ONE 10, e0123000 (2015).","journal-title":"PLoS ONE"},{"key":"31987_CR47","doi-asserted-by":"publisher","first-page":"389","DOI":"10.3389\/fbioe.2021.643453","volume":"9","author":"M Baiocchi","year":"2021","unstructured":"Baiocchi, M. et al. Effects of choice of medical imaging modalities on a non-invasive diagnostic and monitoring computational framework for patients with complex valvular, vascular, and ventricular diseases who undergo transcatheter aortic valve replacement. Front. Bioeng. Biotechnol. 9, 389 (2021).","journal-title":"Front. Bioeng. Biotechnol."},{"key":"31987_CR48","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1007\/s00246-021-02690-2","volume":"43","author":"M Asaadi","year":"2022","unstructured":"Asaadi, M. et al. On left ventricle stroke work efficiency in children with moderate aortic valve regurgitation or moderate aortic valve stenosis. Pediatr. Cardiol. 43, 45\u201353 (2022).","journal-title":"Pediatr. Cardiol."},{"key":"31987_CR49","doi-asserted-by":"publisher","unstructured":"Bahadormanesh, N. et al. A Doppler-exclusive non-invasive computational diagnostic framework for personalized transcatheter aortic valve replacement. Sci. Rep. 13, 8033. https:\/\/doi.org\/10.1038\/s41598-023-33511-6 (2023).","DOI":"10.1038\/s41598-023-33511-6"},{"key":"31987_CR50","doi-asserted-by":"publisher","unstructured":"Khodaei, S., Abdelkhalek, M., Maftoon, N., Emadi, A., Keshavarz-Motamed, Z. Early detection of risk of neo-sinus blood stasis post-transcatheter aortic valve replacement using personalized hemodynamic analysis. Structural Heart. 100180. https:\/\/doi.org\/10.1016\/j.shj.2023.100180 (2023).","DOI":"10.1016\/j.shj.2023.100180"},{"key":"31987_CR51","doi-asserted-by":"crossref","unstructured":"Bahadormanesh, N., Tomka, B., Kadem, M., Khodaei, S. & Keshavarz-Motamed, Z. An ultrasound-exclusive non-invasive computational diagnostic framework for personalized cardiology of aortic valve stenosis. Medical Image Analysis. 87, 102795 (2023).","DOI":"10.1016\/j.media.2023.102795"},{"key":"31987_CR52","doi-asserted-by":"publisher","unstructured":"Khodaei, S. et al. Long-term prognostic impact of paravalvular leakage on coronary artery disease requires patient-specific quantification of hemodynamics. Sci. Rep. 12, 21357. https:\/\/doi.org\/10.1038\/s41598-022-21104-8 (2022).","DOI":"10.1038\/s41598-022-21104-8"},{"key":"31987_CR53","doi-asserted-by":"publisher","first-page":"1953","DOI":"10.1016\/j.jcin.2016.06.054","volume":"9","author":"Z Keshavarz-Motamed","year":"2016","unstructured":"Keshavarz-Motamed, Z. et al. Elimination of transcoarctation pressure gradients has no impact on left ventricular function or aortic shear stress after intervention in patients with mild coarctation. JACC Cardiovasc. Interv. 9, 1953\u20131965 (2016).","journal-title":"JACC Cardiovasc. Interv."},{"key":"31987_CR54","doi-asserted-by":"publisher","first-page":"9048","DOI":"10.1038\/s41598-020-65576-y","volume":"10","author":"R Sadeghi","year":"2020","unstructured":"Sadeghi, R., Khodaei, S., Ganame, J. & Keshavarz-Motamed, Z. Towards non-invasive computational-mechanics and imaging-based diagnostic framework for personalized cardiology for coarctation. Sci. Rep. 10, 9048 (2020).","journal-title":"Sci. Rep."},{"key":"31987_CR55","doi-asserted-by":"publisher","first-page":"e86793","DOI":"10.1371\/journal.pone.0086793","volume":"9","author":"Z Keshavarz-Motamed","year":"2014","unstructured":"Keshavarz-Motamed, Z. et al. Non-invasive determination of left ventricular workload in patients with aortic stenosis using magnetic resonance imaging and doppler echocardiography. PLoS ONE 9, e86793 (2014).","journal-title":"PLoS ONE"},{"key":"31987_CR56","doi-asserted-by":"publisher","unstructured":"Sadeghi, R. et al. Reducing morbidity and mortality in patients with coarctation requires systematic differentiation of impacts of mixed valvular disease on coarctation hemodynamics. J. Am. Heart Assoc. 11, e022664. https:\/\/doi.org\/10.1161\/JAHA.121.022664 (2022).","DOI":"10.1161\/JAHA.121.022664"},{"key":"31987_CR57","doi-asserted-by":"publisher","first-page":"107038","DOI":"10.1016\/j.ijmecsci.2021.107038","volume":"217","author":"R Sadeghi","year":"2022","unstructured":"Sadeghi, R., Gasner, N., Khodaei, S., Garcia, J. & Keshavarz-Motamed, Z. Impact of mixed valvular disease on coarctation hemodynamics using patient-specific lumped parameter and Lattice Boltzmann modeling. Int. J. Mech. Sci. 217, 107038 (2022).","journal-title":"Int. J. Mech. Sci."},{"key":"31987_CR58","doi-asserted-by":"publisher","first-page":"9718","DOI":"10.1038\/s41598-022-12894-y","volume":"12","author":"R Sadeghi","year":"2022","unstructured":"Sadeghi, R. et al. Impact of extra-anatomical bypass on coarctation fluid dynamics using patient-specific lumped parameter and Lattice Boltzmann modeling. Sci. Rep. 12, 9718 (2022).","journal-title":"Sci. Rep."},{"key":"31987_CR59","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/0141-5425(92)90015-D","volume":"14","author":"S Mantero","year":"1992","unstructured":"Mantero, S., Pietrabissa, R. & Fumero, R. The coronary bed and its role in the cardiovascular system: A review and an introductory single-branch model. J. Biomed. Eng. 14, 109\u2013116 (1992).","journal-title":"J. Biomed. Eng."},{"key":"31987_CR60","doi-asserted-by":"publisher","first-page":"3195","DOI":"10.1007\/s10439-010-0083-6","volume":"38","author":"HJ Kim","year":"2010","unstructured":"Kim, H. J. et al. Patient-specific modeling of blood flow and pressure in human coronary arteries. Ann. Biomed. Eng. 38, 3195\u20133209 (2010).","journal-title":"Ann. Biomed. Eng."},{"key":"31987_CR61","doi-asserted-by":"publisher","first-page":"1842004","DOI":"10.1142\/S0219876218420045","volume":"16","author":"B Li","year":"2019","unstructured":"Li, B., Wang, W., Mao, B. & Liu, Y. A method to personalize the lumped parameter model of coronary artery. Int. J. Comput. Methods 16, 1842004 (2019).","journal-title":"Int. J. Comput. Methods"},{"key":"31987_CR62","doi-asserted-by":"publisher","first-page":"100014","DOI":"10.1016\/j.medntd.2019.100014","volume":"2","author":"B Mao","year":"2019","unstructured":"Mao, B. et al. Lumped parameter model based surgical planning for CABG. Med. Nov. Technol. Devices 2, 100014 (2019).","journal-title":"Med. Nov. Technol. Devices"},{"key":"31987_CR63","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.cma.2019.05.005","volume":"353","author":"M Yin","year":"2019","unstructured":"Yin, M., Yazdani, A. & Karniadakis, G. E. One-dimensional modeling of fractional flow reserve in coronary artery disease: Uncertainty quantification and Bayesian optimization. Comput. Methods Appl. Mech. Eng. 353, 66\u201385 (2019).","journal-title":"Comput. Methods Appl. Mech. Eng."},{"key":"31987_CR64","doi-asserted-by":"publisher","first-page":"e3382","DOI":"10.1002\/cnm.3382","volume":"36","author":"F Tajeddini","year":"2020","unstructured":"Tajeddini, F. et al. High precision invasive FFR, low-cost invasive iFR, or non-invasive CFR? Optimum assessment of coronary artery stenosis based on the patient-specific computational models. Int. J. Numer. Methods Biomed. Eng. 36, e3382 (2020).","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"key":"31987_CR65","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1002\/ccd.20217","volume":"63","author":"M Razminia","year":"2004","unstructured":"Razminia, M. et al. Validation of a new formula for mean arterial pressure calculation: The new formula is superior to the standard formula. Catheter. Cardiovasc. Interv. 63, 419\u2013425 (2004).","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"31987_CR66","doi-asserted-by":"publisher","first-page":"2929","DOI":"10.1088\/0031-9155\/44\/12\/306","volume":"44","author":"Y Zhou","year":"1999","unstructured":"Zhou, Y., Kassab, G. S. & Molloi, S. On the design of the coronary arterial tree: A generalization of Murray\u2019s law. Phys. Med. Biol. 44, 2929\u20132945 (1999).","journal-title":"Phys. Med. Biol."},{"key":"31987_CR67","doi-asserted-by":"publisher","first-page":"2228","DOI":"10.1007\/s10439-012-0579-3","volume":"40","author":"S Sankaran","year":"2012","unstructured":"Sankaran, S. et al. Patient-specific multiscale modeling of blood flow for coronary artery bypass graft surgery. Ann. Biomed. Eng. 40, 2228\u20132242 (2012).","journal-title":"Ann. Biomed. Eng."},{"key":"31987_CR68","doi-asserted-by":"publisher","first-page":"874","DOI":"10.1038\/s41598-018-19164-w","volume":"8","author":"Z Duanmu","year":"2018","unstructured":"Duanmu, Z., Yin, M., Fan, X., Yang, X. & Luo, X. A patient-specific lumped-parameter model of coronary circulation. Sci. Rep. 8, 874 (2018).","journal-title":"Sci. Rep."},{"key":"31987_CR69","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1007\/s10237-012-0383-x","volume":"12","author":"JS Coogan","year":"2013","unstructured":"Coogan, J. S., Humphrey, J. D. & Figueroa, C. A. Computational simulations of hemodynamic changes within thoracic, coronary, and cerebral arteries following early wall remodeling in response to distal aortic coarctation. Biomech. Model. Mechanobiol. 12, 79\u201393 (2013).","journal-title":"Biomech. Model. Mechanobiol."},{"key":"31987_CR70","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1152\/japplphysiol.00049.2008","volume":"106","author":"D Garcia","year":"2009","unstructured":"Garcia, D. et al. Impairment of coronary flow reserve in aortic stenosis. J. Appl. Physiol. 106, 113\u2013121 (2009).","journal-title":"J. Appl. Physiol."},{"key":"31987_CR71","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/0002-8703(95)90233-3","volume":"130","author":"EO Ofili","year":"1995","unstructured":"Ofili, E. O. et al. Differential characterization of blood flow, velocity, and vascular resistance between proximal and distal normal epicardial human coronary arteries: Analysis by intracoronary Doppler spectral flow velocity. Am. Heart J. 130, 37\u201346 (1995).","journal-title":"Am. Heart J."},{"key":"31987_CR72","doi-asserted-by":"publisher","first-page":"1116","DOI":"10.1016\/j.neuroimage.2006.01.015","volume":"31","author":"PA Yushkevich","year":"2006","unstructured":"Yushkevich, P. A. et al. User-guided 3D active contour segmentation of anatomical structures: Significantly improved efficiency and reliability. Neuroimage 31, 1116\u20131128 (2006).","journal-title":"Neuroimage"},{"key":"31987_CR73","doi-asserted-by":"publisher","first-page":"620","DOI":"10.1063\/1.168744","volume":"12","author":"HG Weller","year":"1998","unstructured":"Weller, H. G., Tabor, G., Jasak, H. & Fureby, C. A tensorial approach to computational continuum mechanics using object-oriented techniques. Comput. Phys. 12, 620\u2013631 (1998).","journal-title":"Comput. Phys."},{"key":"31987_CR74","doi-asserted-by":"publisher","first-page":"1","DOI":"10.21278\/TOF.42301","volume":"42","author":"\u017d Tukovi\u0107","year":"2018","unstructured":"Tukovi\u0107, \u017d, Kara\u010d, A., Cardiff, P., Jasak, H. & Ivankovi\u0107, A. OpenFOAM finite volume solver for fluid-solid interaction. Trans. FAMENA 42, 1\u201331 (2018).","journal-title":"Trans. FAMENA"},{"key":"31987_CR75","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.mbs.2016.12.008","volume":"285","author":"S Khodaei","year":"2017","unstructured":"Khodaei, S., Fatouraee, N. & Nabaei, M. Numerical simulation of mitral valve prolapse considering the effect of left ventricle. Math. Biosci. 285, 75\u201380 (2017).","journal-title":"Math. Biosci."},{"key":"31987_CR76","doi-asserted-by":"publisher","first-page":"e029310","DOI":"10.1161\/JAHA.123.029310","volume":"12","author":"S Khodaei","year":"2023","unstructured":"Khodaei, S. et al. Reducing long-term mortality post transcatheter aortic valve replacement requires systemic differentiation of patient-specific coronary hemodynamics. J. Am. Heart Assoc. 12, e029310. https:\/\/doi.org\/10.1161\/JAHA.123.029310 (2023).","journal-title":"J. Am. Heart Assoc."},{"key":"31987_CR77","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1002\/cphy.c160016","volume-title":"Comprehensive Physiology","author":"AG Goodwill","year":"2017","unstructured":"Goodwill, A. G., Dick, G. M., Kiel, A. M. & Tune, J. D. Regulation of coronary blood flow. In Comprehensive Physiology (ed. Terjung, R.) 321\u2013382 (Wiley, 2017). https:\/\/doi.org\/10.1002\/cphy.c160016."},{"key":"31987_CR78","doi-asserted-by":"publisher","first-page":"128","DOI":"10.1016\/j.compfluid.2016.05.015","volume":"142","author":"JS Tran","year":"2017","unstructured":"Tran, J. S., Schiavazzi, D. E., Ramachandra, A. B., Kahn, A. M. & Marsden, A. L. Automated tuning for parameter identification and uncertainty quantification in multi-scale coronary simulations. Comput. Fluids 142, 128\u2013138 (2017).","journal-title":"Comput. Fluids"},{"key":"31987_CR79","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1093\/ehjci\/jew335","volume":"18","author":"H Baumgartner","year":"2017","unstructured":"Baumgartner, H. et al. Recommendations on the echocardiographic assessment of aortic valve stenosis: A focused update from the European Association of Cardiovascular Imaging and the American Society of Echocardiography. Eur. Heart J. Cardiovasc. Imaging 18, 254\u2013275 (2017).","journal-title":"Eur. Heart J. Cardiovasc. Imaging"},{"key":"31987_CR80","doi-asserted-by":"publisher","first-page":"e014631","DOI":"10.1161\/JAHA.119.014631","volume":"8","author":"J Yeoh","year":"2019","unstructured":"Yeoh, J. & MacCarthy, P. The pressure is on: Implications of blood pressure after aortic valve replacement. J. Am. Heart Assoc. 8, e014631 (2019).","journal-title":"J. Am. Heart Assoc."},{"key":"31987_CR81","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1016\/j.jcin.2012.12.124","volume":"6","author":"GY Perlman","year":"2013","unstructured":"Perlman, G. Y. et al. Post-procedural hypertension following transcatheter aortic valve implantation. JACC Cardiovasc. Interv. 6, 472\u2013478 (2013).","journal-title":"JACC Cardiovasc. Interv."},{"key":"31987_CR82","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1093\/bjaceaccp\/mki012","volume":"5","author":"T Ramanathan","year":"2005","unstructured":"Ramanathan, T. & Skinner, H. Coronary blood flow. Contin. Educ. Anaesth. Crit. Care Pain 5, 61\u201364 (2005).","journal-title":"Contin. Educ. Anaesth. Crit. Care Pain"},{"key":"31987_CR83","doi-asserted-by":"publisher","first-page":"1264","DOI":"10.1016\/j.amjcard.2014.07.054","volume":"114","author":"I Ben-Dor","year":"2014","unstructured":"Ben-Dor, I. et al. Coronary blood flow in patients with severe aortic stenosis before and after transcatheter aortic valve implantation. Am. J. Cardiol. 114, 1264\u20131268 (2014).","journal-title":"Am. J. Cardiol."},{"key":"31987_CR84","doi-asserted-by":"publisher","first-page":"1501","DOI":"10.3389\/fbioe.2022.987326","volume":"10","author":"Z Keshavarz-Motamed","year":"2022","unstructured":"Keshavarz-Motamed, Z., Del Alamo, J. C., Bluestein, D., Edelman, E. R. & Wentzel, J. J. Editorial: Novel methods to advance diagnostic and treatment value of medical imaging for cardiovascular disease. Front. Bioeng. Biotechnol. 10, 1501 (2022).","journal-title":"Front. Bioeng. Biotechnol."},{"key":"31987_CR85","doi-asserted-by":"publisher","first-page":"2679","DOI":"10.1161\/CIRCULATIONAHA.106.632687","volume":"113","author":"Y Richter","year":"2006","unstructured":"Richter, Y. & Edelman, E. R. Cardiology is flow. Circulation 113, 2679\u20132682 (2006).","journal-title":"Circulation"},{"key":"31987_CR86","doi-asserted-by":"publisher","first-page":"80","DOI":"10.1007\/s12265-018-9792-2","volume":"11","author":"RA Gray","year":"2018","unstructured":"Gray, R. A. & Pathmanathan, P. Patient-specific cardiovascular computational modeling: Diversity of personalization and challenges. J. Cardiovasc. Transl. Res. 11, 80\u201388 (2018).","journal-title":"J. Cardiovasc. Transl. Res."},{"key":"31987_CR87","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1038\/s41569-018-0104-y","volume":"16","author":"SA Niederer","year":"2019","unstructured":"Niederer, S. A., Lumens, J. & Trayanova, N. A. Computational models in cardiology. Nat. Rev. Cardiol. 16, 100\u2013111 (2019).","journal-title":"Nat. Rev. Cardiol."},{"key":"31987_CR88","doi-asserted-by":"publisher","first-page":"953","DOI":"10.1161\/01.CIR.88.3.953","volume":"88","author":"M Hongo","year":"1993","unstructured":"Hongo, M. et al. Relation of phasic coronary flow velocity profile to clinical and hemodynamic characteristics of patients with aortic valve disease. Circulation 88, 953\u2013960 (1993).","journal-title":"Circulation"},{"key":"31987_CR89","doi-asserted-by":"publisher","first-page":"1557","DOI":"10.1161\/01.CIR.97.16.1557","volume":"97","author":"T Hozumi","year":"1998","unstructured":"Hozumi, T. et al. Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography. Circulation 97, 1557\u20131562 (1998).","journal-title":"Circulation"},{"key":"31987_CR90","doi-asserted-by":"publisher","first-page":"2019","DOI":"10.1016\/j.jcin.2018.07.019","volume":"11","author":"Y Ahmad","year":"2018","unstructured":"Ahmad, Y. et al. Coronary hemodynamics in patients with severe aortic stenosis and coronary artery disease undergoing transcatheter aortic valve replacement. JACC Cardiovasc. Interv. 11, 2019\u20132031 (2018).","journal-title":"JACC Cardiovasc. Interv."},{"key":"31987_CR91","doi-asserted-by":"publisher","first-page":"e015133","DOI":"10.1161\/JAHA.119.015133","volume":"9","author":"J Vendrik","year":"2020","unstructured":"Vendrik, J. et al. Long-term effects of transcatheter aortic valve implantation on coronary hemodynamics in patients with concomitant coronary artery disease and severe aortic stenosis. J. Am. Heart Assoc. 9, e015133 (2020).","journal-title":"J. Am. Heart Assoc."},{"key":"31987_CR92","doi-asserted-by":"publisher","first-page":"1889","DOI":"10.1016\/S0735-1097(00)00947-5","volume":"36","author":"DJ Hildick-Smith","year":"2000","unstructured":"Hildick-Smith, D. J. & Shapiro, L. M. Coronary flow reserve improves after aortic valve replacement for aortic stenosis: An adenosine transthoracic echocardiography study. J. Am. Coll. Cardiol. 36, 1889\u20131896 (2000).","journal-title":"J. Am. Coll. Cardiol."},{"key":"31987_CR93","doi-asserted-by":"publisher","first-page":"H1439","DOI":"10.1152\/ajpheart.00139.2019","volume":"316","author":"G Heusch","year":"2019","unstructured":"Heusch, G. Myocardial ischemia: Lack of coronary blood flow, myocardial oxygen supply-demand imbalance, or what?. Am. J. Physiol. Heart Circ. Physiol. 316, H1439\u2013H1446 (2019).","journal-title":"Am. J. Physiol. Heart Circ. Physiol."},{"key":"31987_CR94","doi-asserted-by":"publisher","first-page":"e007547","DOI":"10.1161\/CIRCINTERVENTIONS.118.007547","volume":"12","author":"HZR McConkey","year":"2019","unstructured":"McConkey, H. Z. R. et al. Coronary microcirculation in aortic stenosis. Circ. Cardiovasc. Interv. 12, e007547 (2019).","journal-title":"Circ. Cardiovasc. Interv."},{"key":"31987_CR95","first-page":"3","volume":"6","author":"S Cangemi","year":"2022","unstructured":"Cangemi, S. et al. Management of concomitant coronary artery disease and aortic valve stenosis in the era of transcatheter aortic valve treatment. Mini-Invasive Surg. 6, 3 (2022).","journal-title":"Mini-Invasive Surg."},{"key":"31987_CR96","doi-asserted-by":"publisher","first-page":"e010226","DOI":"10.1161\/CIRCINTERVENTIONS.120.010226","volume":"13","author":"MA Cavender","year":"2020","unstructured":"Cavender, M. A. & Forrest, J. K. Planning for the next transcatheter aortic valve replacement starts today. Circ. Cardiovasc. Interv. 13, e010226 (2020).","journal-title":"Circ. Cardiovasc. Interv."},{"key":"31987_CR97","doi-asserted-by":"publisher","unstructured":"Maasrani, M. et al. Simulations of fluxes in diseased coronary network using an electrical model. In The XIX International Conference on Electrical Machines-ICEM 2010 1\u20136 (2010)https:\/\/doi.org\/10.1109\/ICELMACH.2010.5608460","DOI":"10.1109\/ICELMACH.2010.5608460"},{"key":"31987_CR98","doi-asserted-by":"publisher","first-page":"H517","DOI":"10.1152\/ajpheart.00603.2013","volume":"306","author":"JP Mynard","year":"2014","unstructured":"Mynard, J. P., Penny, D. J. & Smolich, J. J. Scalability and in vivo validation of a multiscale numerical model of the left coronary circulation. Am. J. Physiol. Heart Circ. Physiol. 306, H517\u2013H528 (2014).","journal-title":"Am. J. Physiol. Heart Circ. Physiol."},{"key":"31987_CR99","doi-asserted-by":"publisher","first-page":"477","DOI":"10.1016\/1350-4533(96)00002-1","volume":"18","author":"R Pietrabissa","year":"1996","unstructured":"Pietrabissa, R., Mantero, S., Marotta, T. & Menicanti, L. A lumped parameter model to evaluate the fluid dynamics of different coronary bypasses. Med. Eng. Phys. 18, 477\u2013484 (1996).","journal-title":"Med. Eng. Phys."},{"key":"31987_CR100","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1111\/aor.12589","volume":"40","author":"J Calderan","year":"2016","unstructured":"Calderan, J., Mao, W., Sirois, E. & Sun, W. Development of an in vitro model to characterize the effects of transcatheter aortic valve on coronary artery flow. Artif. Organs 40, 612\u2013619 (2016).","journal-title":"Artif. Organs"},{"key":"31987_CR101","doi-asserted-by":"publisher","first-page":"742","DOI":"10.3389\/fphys.2018.00742","volume":"9","author":"L Zhong","year":"2018","unstructured":"Zhong, L. et al. Application of patient-specific computational fluid dynamics in coronary and intra-cardiac flow simulations: Challenges and opportunities. Front. Physiol. 9, 742 (2018).","journal-title":"Front. Physiol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-31987-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-31987-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-31987-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,2]],"date-time":"2023-06-02T10:09:14Z","timestamp":1685700554000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-31987-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,2]]},"references-count":101,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["31987"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-31987-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,2]]},"assertion":[{"value":"30 November 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 March 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 June 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"8948"}}