{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T06:46:24Z","timestamp":1794638784678,"version":"4.9.1"},"reference-count":49,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,4,17]],"date-time":"2023-04-17T00:00:00Z","timestamp":1681689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,4,17]],"date-time":"2023-04-17T00:00:00Z","timestamp":1681689600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"International Research Collaboration Co-Funding Program","award":["CL\/SQU-QU\/ENG\/22\/01"],"award-info":[{"award-number":["CL\/SQU-QU\/ENG\/22\/01"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Bone drilling is a universal procedure in orthopaedics for fracture fixation, installing implants, or reconstructive surgery. Surgical drills are subjected to wear caused by their repeated use, thermal fatigue, irrigation with saline solution, and sterilization process. Wear of the cutting edges of a drill bit (worn drill) is detrimental for bone tissues and can seriously affect its performance. The aim of this study is to move closer to minimally invasive surgical procedures in bones by investigating the effect of wear of surgical drill bits on their performance. The surface quality of the drill was found to influence the bone temperature, the axial force, the torque and the extent of biological damage around the drilling region. Worn drill produced heat above the threshold level related to thermal necrosis at a depth equal to the wall thickness of an adult human bone. Statistical analysis showed that a sharp drill bit, in combination with a medium drilling speed and drilling at shallow depth, was favourable for safe drilling in bone. This study also suggests the further research on establishing a relationship between surface integrity of a surgical drill bit and irreversible damage that it can induce in delicate tissues of bone using different drill sizes as well as drilling parameters and conditions.<\/jats:p>","DOI":"10.1038\/s41598-023-33381-y","type":"journal-article","created":{"date-parts":[[2023,4,17]],"date-time":"2023-04-17T05:05:05Z","timestamp":1681707905000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":41,"title":["Effect of drill quality on biological damage in bone drilling"],"prefix":"10.1038","volume":"13","author":[{"given":"Khurshid","family":"Alam","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sayyad Zahid","family":"Qamar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad","family":"Iqbal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sujan","family":"Piya","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mahmood","family":"Al-Kindi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asim","family":"Qureshi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Al-Ghaithi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Badar","family":"Al-Sumri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vadim V.","family":"Silberschmidt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,4,17]]},"reference":[{"key":"33381_CR1","doi-asserted-by":"publisher","first-page":"741","DOI":"10.3233\/THC-140848","volume":"22","author":"K Alam","year":"2014","unstructured":"Alam, K. Experimental and numerical investigation of cracking behavior of cortical bone in cutting. Technol. Health Care 22, 741\u2013750 (2014).","journal-title":"Technol. Health Care"},{"key":"33381_CR2","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1016\/j.medengphy.2010.10.003","volume":"33","author":"K Alam","year":"2011","unstructured":"Alam, K., Mitrofanov, A. V. & Silberschmidt, V. V. Experimental investigations of forces and torque in conventional and ultrasonically-assisted drilling of cortical bone. Med. Eng. Phys. 33, 234\u2013239 (2011).","journal-title":"Med. Eng. Phys."},{"key":"33381_CR3","doi-asserted-by":"publisher","first-page":"7420718","DOI":"10.1155\/2020\/7420718","volume":"2020","author":"P Kosior","year":"2020","unstructured":"Kosior, P., Pelc, A. & Mikulewicz, M. Comparative analysis of bone tissue temperature during implant preparation with variable drilling parameters: In vitro study. Biomed. Res. Int. 2020, 7420718 (2020).","journal-title":"Biomed. Res. Int."},{"key":"33381_CR4","first-page":"637","volume":"233","author":"MG Fernandes","year":"2019","unstructured":"Fernandes, M. G., Fonseca, E. M. & Jorge, R. N. Thermo-mechanical stresses distribution on bone drilling: Numerical and experimental procedures. Proc. Inst. Mech. Eng. L J. Mater. 233, 637\u2013646 (2019).","journal-title":"Proc. Inst. Mech. Eng. L J. Mater."},{"key":"33381_CR5","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.jcot.2013.01.002","volume":"4","author":"RK Pandey","year":"2013","unstructured":"Pandey, R. K. & Panda, D. D. Drilling of bone: A comprehensive review. J. Clin. Orthop. Trauma. 4, 15\u201330 (2013).","journal-title":"J. Clin. Orthop. Trauma."},{"key":"33381_CR6","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1016\/j.clinbiomech.2011.10.010","volume":"27","author":"G Augustin","year":"2012","unstructured":"Augustin, G. et al. Cortical bone drilling and thermal osteonecrosis. Clin. Biomech. 27, 313\u2013325 (2012).","journal-title":"Clin. Biomech."},{"key":"33381_CR7","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1016\/j.jmbbm.2014.12.006","volume":"44","author":"MD Marco","year":"2015","unstructured":"Marco, M. D., Rodriguez-Millan, M., Santiuste, C., Giner, E. & Miguelez, M. H. A review on recent advances in numerical modelling of bone cutting. J. Mech. Behav. Biomed. Mater. 44, 179\u2013201 (2015).","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"33381_CR8","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.foot.2018.02.002","volume":"35","author":"NA Omar","year":"2018","unstructured":"Omar, N. A. & McKinley, J. C. Measurement of temperature induced in bone during drilling in minimally invasive foot surgery. Foot 35, 63\u201369 (2018).","journal-title":"Foot"},{"key":"33381_CR9","doi-asserted-by":"publisher","first-page":"102342","DOI":"10.1016\/j.mechatronics.2020.102342","volume":"6","author":"M Rossini","year":"2020","unstructured":"Rossini, M. et al. Localization of drilling tool position through bone tissue identification during surgical drilling. Mechatronics 6, 102342 (2020).","journal-title":"Mechatronics"},{"key":"33381_CR10","doi-asserted-by":"publisher","first-page":"1218","DOI":"10.1007\/s10439-019-02444-5","volume":"48","author":"Y Torun","year":"2020","unstructured":"Torun, Y. & \u00d6zt\u00fcrk, A. A new breakthrough detection method for bone drilling in robotic orthopedic surgery with closed-loop control approach. Ann. Biomed. Eng. 48, 1218\u20131229 (2020).","journal-title":"Ann. Biomed. Eng."},{"key":"33381_CR11","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1097\/BOT.0b013e318156c288","volume":"22","author":"JL Bassi","year":"2008","unstructured":"Bassi, J. L., Pankaj, M. & Navdeep, S. A technique for removal of broken cannulated drill bit: Bassi\u2019s method. J. Orthop. Trauma 22, 56\u201358 (2008).","journal-title":"J. Orthop. Trauma"},{"key":"33381_CR12","doi-asserted-by":"publisher","first-page":"S5","DOI":"10.1016\/S0020-1383(10)80002-6","volume":"23","author":"U Hirt","year":"1992","unstructured":"Hirt, U., Auer, J. & Perren, S. Drill bit failure without implant involvement\u2014An intraoperative complication in orthopaedic surgery. Injury 23, S5\u2013S16 (1992).","journal-title":"Injury"},{"key":"33381_CR13","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1007\/s00402-007-0427-3","volume":"128","author":"G Augustin","year":"2008","unstructured":"Augustin, G. et al. Thermal osteonecrosis and bone drilling parameters revisited. Arch. Orthop. Trauma Surg. 128, 71\u201377 (2008).","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"33381_CR14","doi-asserted-by":"publisher","first-page":"1221","DOI":"10.1016\/j.medengphy.2011.05.013","volume":"33","author":"F Karaca","year":"2011","unstructured":"Karaca, F., Aksakal, B. & Kom, M. Influence of orthopaedic drilling parameters on temperature and histopathology of bovine tibia: An in vitro study. Med. Eng. Phys. 33, 1221\u20131227 (2011).","journal-title":"Med. Eng. Phys."},{"key":"33381_CR15","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/j.proeng.2017.04.074","volume":"184","author":"V Gupta","year":"2017","unstructured":"Gupta, V., Pandey, P. M., Mridha, A. R. & Gupta, R. K. Effect of various parameters on the temperature distribution in conventional and diamond coated hollow tool bone drilling: A comparative study. Procedia Eng. 184, 90\u201398 (2017).","journal-title":"Procedia Eng."},{"key":"33381_CR16","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1115\/1.3138356","volume":"104","author":"S Saha","year":"1982","unstructured":"Saha, S., Pal, S. & Albright, J. A. Surgical drilling: Design and performance of an improved drill. J. Biomech. Eng. 104, 245\u2013252 (1982).","journal-title":"J. Biomech. Eng."},{"key":"33381_CR17","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.1016\/j.medengphy.2012.12.004","volume":"35","author":"GJ Tuijthof","year":"2013","unstructured":"Tuijthof, G. J., Fruhwirt, C. & Kment, C. Influence of tool geometry on drilling performance of cortical and trabecular bone. Med. Eng. Phys. 35, 1165\u20131172 (2013).","journal-title":"Med. Eng. Phys."},{"key":"33381_CR18","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1146\/annurev-bioeng-070909-105302","volume":"12","author":"CR Jacobs","year":"2010","unstructured":"Jacobs, C. R., Temiyasathit, S. & Castillo, A. B. Osteocyte mechanobiology and pericellular mechanics. Ann. Rev. Biomed. Eng. 12, 369\u2013400 (2010).","journal-title":"Ann. Rev. Biomed. Eng."},{"key":"33381_CR19","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1016\/j.jbiomech.2009.09.016","volume":"43","author":"JH Chen","year":"2010","unstructured":"Chen, J. H., Liu, C., You, L. & Simmons, C. A. Boning up on Wolff\u2019s law: Mechanical regulation of the cells that make and maintain bone. J. Biomech. 43, 108\u2013118 (2010).","journal-title":"J. Biomech."},{"key":"33381_CR20","doi-asserted-by":"publisher","first-page":"78","DOI":"10.1016\/j.medengphy.2019.03.013","volume":"67","author":"K Alam","year":"2019","unstructured":"Alam, K., Al-Ghaithi, A., Piya, S. & Ashraf, S. In-vitro experimental study on the histopathology of bone in ultrasonically assisted drilling. Med. Eng. Phys. 67, 78\u201387 (2019).","journal-title":"Med. Eng. Phys."},{"key":"33381_CR21","first-page":"e5226","volume":"11","author":"C Timon","year":"2019","unstructured":"Timon, C. & Keady, C. Thermal osteonecrosis caused by bone drilling in orthopedic surgery: A literature review. Cureus 11, e5226 (2019).","journal-title":"Cureus"},{"key":"33381_CR22","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/j.jbiomech.2018.02.025","volume":"71","author":"JE Lee","year":"2018","unstructured":"Lee, J. E., Chavez, C. L. & Park, J. Parameters affecting mechanical and thermal responses in bone drilling: A review. J. Biomech. 71, 4\u201321 (2018).","journal-title":"J. Biomech."},{"key":"33381_CR23","doi-asserted-by":"publisher","first-page":"109215","DOI":"10.1016\/j.matdes.2020.109215","volume":"97","author":"JA Robles-Linares","year":"2021","unstructured":"Robles-Linares, J. A., Axinte, D., Liao, Z. & Gameros, A. Machining-induced thermal damage in cortical bone: Necrosis and micro-mechanical integrity. Mater. Des. 97, 109215 (2021).","journal-title":"Mater. Des."},{"key":"33381_CR24","doi-asserted-by":"publisher","first-page":"326","DOI":"10.3944\/AOTT.2014.3074","volume":"48","author":"K Faruk","year":"2014","unstructured":"Faruk, K., B\u00fcnyamin, L. & Mustafa, K. Effects of bone drilling on local temperature and bone regeneration: An in vivo study. Acta Orthop. Traumatol. Turc. 48, 326\u2013332 (2014).","journal-title":"Acta Orthop. Traumatol. Turc."},{"key":"33381_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-020-77762-z","volume":"10","author":"SA Gehrke","year":"2020","unstructured":"Gehrke, S. A. et al. Effects of the technique and drill design used during the osteotomy on the thermal and histological stimulation. Sci. Rep. 10, 1\u201311 (2020).","journal-title":"Sci. Rep."},{"key":"33381_CR26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.medengphy.2018.12.019","volume":"65","author":"Z Sun","year":"2019","unstructured":"Sun, Z. et al. Experimental investigations of drilling temperature of high-energy ultrasonically assisted bone drilling. Med. Eng. Phys. 65, 1\u20137 (2019).","journal-title":"Med. Eng. Phys."},{"key":"33381_CR27","doi-asserted-by":"publisher","first-page":"975","DOI":"10.1177\/0954411918794983","volume":"232","author":"G Singh","year":"2019","unstructured":"Singh, G., Jain, V., Gupta, D. & Sharma, A. Parametric effect of vibrational drilling on osteonecrosis and comparative histopathology study with conventional drilling of cortical bone. Proc. Inst. Mech. Eng. H 232, 975\u2013986 (2019).","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"33381_CR28","first-page":"1408","volume":"4","author":"YU Wang","year":"2017","unstructured":"Wang, Y. U. et al. Experimental investigations and finite element simulation of cutting heat in vibrational and conventional drilling of cortical bone. Med. Eng. Phys. 4, 1408\u20131415 (2017).","journal-title":"Med. Eng. Phys."},{"key":"33381_CR29","doi-asserted-by":"publisher","first-page":"95441191668850","DOI":"10.1177\/0954411916688500","volume":"231","author":"V Gupta","year":"2017","unstructured":"Gupta, V., Pandey, P. M., Gupta, R. K. & Mridha, A. R. Rotary ultrasonic drilling on bone: A novel technique to put an end to thermal injury to bone. Proc. Inst. Mech. Eng. H 231, 95441191668850 (2017).","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"33381_CR30","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1016\/j.medengphy.2020.03.002","volume":"79","author":"PS Ravinder","year":"2020","unstructured":"Ravinder, P. S., Pandey, P. M. & Mridha, A. R. An in-vitro study of temperature rise during rotary ultrasonic bone drilling of human bone. Med. Eng. Phys. 79, 33\u201343 (2020).","journal-title":"Med. Eng. Phys."},{"key":"33381_CR31","doi-asserted-by":"publisher","first-page":"1894","DOI":"10.1080\/10426914.2018.1476768","volume":"33","author":"K Alam","year":"2018","unstructured":"Alam, K. & Qamar, Z. Ultrasonically assisted bone drilling\u2014Effect of process parameters on delamination. Mater. Manuf. Process. 33, 1894\u20131898 (2018).","journal-title":"Mater. Manuf. Process."},{"key":"33381_CR32","doi-asserted-by":"publisher","first-page":"1281","DOI":"10.1007\/s10439-020-02452-w","volume":"48","author":"Z Ying","year":"2020","unstructured":"Ying, Z., Shu, L. & Sugita, N. Experimental and finite element analysis of force and temperature in ultrasonic vibration assisted bone cutting. Ann. Biomed. Eng. 48, 1281\u20131290 (2020).","journal-title":"Ann. Biomed. Eng."},{"key":"33381_CR33","doi-asserted-by":"publisher","first-page":"103599","DOI":"10.1016\/j.jmbbm.2019.103599","volume":"103","author":"L Shu","year":"2020","unstructured":"Shu, L. & Sugita, N. Analysis of fracture, force, and temperature in orthogonal elliptical vibration-assisted bone cutting. J. Mech. Behav. Biomed. 103, 103599 (2020).","journal-title":"J. Mech. Behav. Biomed."},{"key":"33381_CR34","doi-asserted-by":"publisher","first-page":"1023","DOI":"10.1002\/jbm.b.34975","volume":"110","author":"RP Singh","year":"2022","unstructured":"Singh, R. P., Pandey, P. M., Mir, M. A. & Mridha, A. R. Thermal changes during drilling in human femur by rotary ultrasonic bone drilling machine: A histologic and ultrastructural study. J. Biomed. Mater. Res. B Appl. Biomater. 110, 1023\u20131033 (2022).","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"key":"33381_CR35","doi-asserted-by":"publisher","first-page":"398","DOI":"10.1177\/0954411919898301","volume":"234","author":"V Gupta","year":"2020","unstructured":"Gupta, V., Singh, R. P., Pandey, P. M. & Gupta, R. In vitro comparison of conventional surgical and rotary ultrasonic bone drilling techniques. Proc. Inst. Mech. Eng. H 234, 398\u2013411 (2020).","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"33381_CR36","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1515\/bmt-2018-0184","volume":"65","author":"K Alam","year":"2019","unstructured":"Alam, K., Piya, S., Al-Ghaithi, A. & Silberschmidt, V. V. Experimental investigation on the effect of drill quality on the performance in bone drilling. Biomed. Eng.-Biomed. Technol. 65, 113\u2013120 (2019).","journal-title":"Biomed. Eng.-Biomed. Technol."},{"key":"33381_CR37","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/j.medengphy.2019.02.010","volume":"66","author":"A Feldmann","year":"2019","unstructured":"Feldmann, A., Schweizer, M., Stucki, S. & Nolte, L. Experimental evaluation of cortical bone substitute materials for tool development, surgical training and drill bit wear investigations. Med. Eng. Phys. 66, 107\u2013112 (2019).","journal-title":"Med. Eng. Phys."},{"key":"33381_CR38","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1016\/j.medengphy.2015.03.014","volume":"37","author":"T Staroveski","year":"2015","unstructured":"Staroveski, T., Brezak, D. & Udiljak, T. Drill wear monitoring in cortical bone drilling. Med. Eng. Phys. 37, 560\u2013566 (2015).","journal-title":"Med. Eng. Phys."},{"key":"33381_CR39","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1007\/s00264-002-0344-6","volume":"26","author":"MV Price","year":"2002","unstructured":"Price, M. V., Molloy, S., Solan, M. C., Sutton, A. & Ricketts, D. M. The rate of instrument breakage during orthopaedic procedures. Int. Orthop. 26, 185\u2013187 (2002).","journal-title":"Int. Orthop."},{"key":"33381_CR40","doi-asserted-by":"publisher","first-page":"1166","DOI":"10.1080\/0305215X.2019.1639693","volume":"52","author":"R Arunachalam","year":"2020","unstructured":"Arunachalam, R. et al. Optimization of stir\u2013squeeze casting parameters for production of metal matrix composites using a hybrid analytical hierarchy process\u2014Taguchi\u2013Grey approach. Eng. Optimiz. 52, 1166\u20131183 (2020).","journal-title":"Eng. Optimiz."},{"key":"33381_CR41","first-page":"307","volume":"233","author":"R Muraliraja","year":"2019","unstructured":"Muraliraja, R., Arunachalam, R., Al-Fori, I., Al-Maharbi, M. & Piya, S. Development of alumina reinforced aluminum metal matrix composite with enhanced compressive strength through squeeze casting process. Proc. Inst. Mech. Eng. L J. Mater. 233, 307\u2013314 (2019).","journal-title":"Proc. Inst. Mech. Eng. L J. Mater."},{"key":"33381_CR42","doi-asserted-by":"publisher","first-page":"1273","DOI":"10.1108\/BIJ-03-2020-0108","volume":"28","author":"S Piya","year":"2021","unstructured":"Piya, S., Shamsuzzoha, A., Khadem, M. & Al, K. M. Integrated analytical hierarchy process and grey relational analysis approach to measure supply chain complexity. Benchmark. Int. J. 28, 1273\u20131295 (2021).","journal-title":"Benchmark. Int. J."},{"key":"33381_CR43","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1034\/j.1600-0501.2000.110206.x","volume":"11","author":"RM Jochum","year":"2000","unstructured":"Jochum, R. M. & Reichart, P. A. Influence of multiple use of Timedur-titanium cannon drills: Thermal response and scanning electron microscopic findings. Clin. Oral Implants Res. 11, 139\u2013143 (2000).","journal-title":"Clin. Oral Implants Res."},{"key":"33381_CR44","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.joms.2005.10.011","volume":"64","author":"GE Chacon","year":"2006","unstructured":"Chacon, G. E., Bower, D. L., Larsen, P. E., McGlumphy, E. A. & Beck, F. M. Heat production by 3 implant drill systems after repeated drilling and sterilization. J. Oral Maxillofac. Surg. 64, 265\u2013269 (2006).","journal-title":"J. Oral Maxillofac. Surg."},{"key":"33381_CR45","doi-asserted-by":"publisher","first-page":"73","DOI":"10.15171\/joddd.2017.014","volume":"11","author":"HJ Moradi","year":"2017","unstructured":"Moradi, H. J. et al. Comparison of the effect of three autogenous bone harvesting methods on cell viability in rabbits. J. Dent. Res. Dent. Clin. Dent. Prospects 11, 73\u201377 (2017).","journal-title":"J. Dent. Res. Dent. Clin. Dent. Prospects"},{"key":"33381_CR46","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1016\/j.jcms.2017.10.004","volume":"46","author":"A Alexandre","year":"2018","unstructured":"Alexandre, A. et al. Structural and ultrastructural analyses of bone regeneration in rabbit cranial osteotomy: Piezosurgery versus traditional osteotomes. J. Cranio-Maxillofac. Surg. 46, 107\u2013118 (2018).","journal-title":"J. Cranio-Maxillofac. Surg."},{"key":"33381_CR47","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1186\/1479-5876-11-221","volume":"11","author":"JC Esteves","year":"2013","unstructured":"Esteves, J. C. et al. Dynamics of bone healing after osteotomy with piezosurgery or conventional drilling\u2014Histomorphometrical, immunohistochemical, and molecular analysis. J. Transl. Med. 11, 221\u2013233 (2013).","journal-title":"J. Transl. Med."},{"key":"33381_CR48","doi-asserted-by":"publisher","first-page":"687","DOI":"10.3233\/THC-181246","volume":"26","author":"S Gholampour","year":"2018","unstructured":"Gholampour, S., Shakouri, E. & Hassanali, D. H. H. Effect of drilling direction and depth on thermal necrosis during Tibia drilling: An in vitro study. Technol. Health Care 26, 687\u2013697 (2018).","journal-title":"Technol. Health Care"},{"key":"33381_CR49","doi-asserted-by":"publisher","first-page":"1102","DOI":"10.1016\/j.arth.2015.11.002","volume":"31","author":"GF Tawy","year":"2019","unstructured":"Tawy, G. F., Rowe, P. J. & Riches, P. E. Thermal damage done to bone by burring and sawing with and without irrigation in knee arthroplasty. J. Arthroplasty 31, 1102\u20131108 (2019).","journal-title":"J. Arthroplasty"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-33381-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-33381-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-33381-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,17]],"date-time":"2023-04-17T06:18:59Z","timestamp":1681712339000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-33381-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4,17]]},"references-count":49,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["33381"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-33381-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4,17]]},"assertion":[{"value":"16 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 April 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 April 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"6234"}}