{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,31]],"date-time":"2026-08-31T20:25:04Z","timestamp":1788207904640,"version":"build-2803163510"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,6,2]],"date-time":"2023-06-02T00:00:00Z","timestamp":1685664000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,6,2]],"date-time":"2023-06-02T00:00:00Z","timestamp":1685664000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>This paper proposes a metal artifact reduction method of using MV-CBCT images to correct metal artifacts in kV-CT images, especially for the complex metal artifacts caused by multi-metal interaction of patients with head and neck tumors. The different tissue regions are segmented in the MV-CBCT images to obtain template images and the metal region is segmented in the kV-CT images. Forward projection is performed to get sinogram of the template images, kV-CT images and metal region images. Artifact images can be reconstructed through those sonograms. Corrected images is generated by subtracting the artifact images from the original kV-CT images. After the first correction, the template images are generated again and brought into the previous step for iteration to get better correction result. CT data set of 7 patients are used in this study, compared with linear interpolation metal artifact (LIMAR) and normalized metal artifact reduction method, mean relative error of CT value is reduced by 50.5% and 63.3%, noise is reduced by 56.2% and 58.9%. The Identifiability Score of the tooth, upper\/lower jaw, tongue, lips, masseter muscle and cavity in the corrected images by the proposed method have significantly improved (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05) than original images. The artifacts correction method proposed in this paper can effectively remove the metal artifacts in the images and greatly improve the CT value accuracy, especially in the case of multi-metal and complex metal implantation.<\/jats:p>","DOI":"10.1038\/s41598-023-35736-x","type":"journal-article","created":{"date-parts":[[2023,6,2]],"date-time":"2023-06-02T09:03:08Z","timestamp":1685696588000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Metal artifacts reduction in kV-CT images with polymetallic dentures and complex metals based on MV-CBCT images in radiotherapy"],"prefix":"10.1038","volume":"13","author":[{"given":"Xiaochen","family":"Ni","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhonghua","family":"Shi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinmao","family":"Song","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tianci","family":"Tang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shengwei","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhenfeng","family":"Hou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei Fang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fu","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gang","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruichen","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoshen","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,6,2]]},"reference":[{"key":"35736_CR1","unstructured":"Hseih J. Computed tomography\u2014Principles, design, artifacts and recent advances. Spie\u2014the International Society for Optical Engineering (2009)."},{"issue":"1","key":"35736_CR2","doi-asserted-by":"publisher","first-page":"98","DOI":"10.3390\/tomography9010009","volume":"9","author":"K Katsura","year":"2023","unstructured":"Katsura, K. et al. The relationship between the contouring time of the metal artifacts area and metal artifacts in head and neck radiotherapy. Tomography. 9(1), 98\u2013104. https:\/\/doi.org\/10.3390\/tomography9010009 (2023).","journal-title":"Tomography."},{"issue":"2","key":"35736_CR3","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1148\/radiology.164.2.3602406","volume":"164","author":"WA Kalender","year":"1987","unstructured":"Kalender, W. A., Hebel, R. & Ebersberger, J. Reduction of CT artifacts caused by metallic implants. Radiology 164(2), 576\u2013577. https:\/\/doi.org\/10.1148\/radiology.164.2.3602406 (1987).","journal-title":"Radiology"},{"issue":"10","key":"35736_CR4","doi-asserted-by":"publisher","first-page":"5482","DOI":"10.1118\/1.3484090","volume":"37","author":"E Meyer","year":"2010","unstructured":"Meyer, E., Raupach, R., Lell, M., Schmidt, B. & Kachelriess, M. Normalized metal artifacts reduction (NMAR) in computed tomography. Med. Phys. 37(10), 5482\u20135493. https:\/\/doi.org\/10.1118\/1.3484090 (2010).","journal-title":"Med. Phys."},{"issue":"006","key":"35736_CR5","doi-asserted-by":"publisher","first-page":"1032","DOI":"10.3788\/YJYXS20153006.1032","volume":"000","author":"M Li","year":"2015","unstructured":"Li, M. et al. Metal artifacts reduction in computed tomography based on prior interpolation. Chin. J. Liquid Cryst. Displays 000(006), 1032\u20131039. https:\/\/doi.org\/10.3788\/YJYXS20153006.1032 (2015).","journal-title":"Chin. J. Liquid Cryst. Displays"},{"issue":"2","key":"35736_CR6","doi-asserted-by":"publisher","first-page":"380","DOI":"10.2214\/AJR.14.13334","volume":"205","author":"S Boudabbous","year":"2015","unstructured":"Boudabbous, S. et al. Model-based iterative reconstruction (MBIR) for the reduction of metal artifacts on CT. Am. J. Roentgenol. 205(2), 380\u2013385. https:\/\/doi.org\/10.2214\/AJR.14.13334 (2015).","journal-title":"Am. J. Roentgenol."},{"issue":"12","key":"35736_CR7","doi-asserted-by":"publisher","first-page":"836","DOI":"10.9746\/sicetr.51.836","volume":"51","author":"T Kano","year":"2015","unstructured":"Kano, T. & Koseki, M. Metal artifacts reduction using iterative reconstruction algorithm. Trans. Soc. Instrum. Control Eng. 51(12), 836\u2013844. https:\/\/doi.org\/10.9746\/sicetr.51.836 (2015).","journal-title":"Trans. Soc. Instrum. Control Eng."},{"key":"35736_CR8","doi-asserted-by":"publisher","first-page":"109293","DOI":"10.1016\/j.ejrad.2020.109293","volume":"132","author":"H Washio","year":"2020","unstructured":"Washio, H. et al. Metal artifacts reduction using iterative CBCT reconstruction algorithm for head and neck radiation therapy: A phantom and clinical study. Eur. J. Radiol. 132, 109293. https:\/\/doi.org\/10.1016\/j.ejrad.2020.109293 (2020).","journal-title":"Eur. J. Radiol."},{"issue":"2","key":"35736_CR9","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1007\/s00256-012-1458-6","volume":"42","author":"M Lewis","year":"2013","unstructured":"Lewis, M., Reid, K. & Toms, A. P. Reducing the effects of metal artefact using high keV monoenergetic reconstruction of dual energy CT (DECT) in hip replacements. Skeletal Radiol. 42(2), 275\u2013282. https:\/\/doi.org\/10.1007\/s00256-012-1458-6 (2013).","journal-title":"Skeletal Radiol."},{"issue":"1","key":"35736_CR10","doi-asserted-by":"publisher","first-page":"e11","DOI":"10.1016\/j.crad.2013.08.008","volume":"69","author":"M Kidoh","year":"2014","unstructured":"Kidoh, M. et al. Reduction of dental metallic artefacts in CT: Value of a newly developed algorithm for metal artefact reduction (O-MAR). Clin. Radiol. 69(1), e11\u2013e16 (2014).","journal-title":"Clin. Radiol."},{"issue":"8","key":"35736_CR11","doi-asserted-by":"publisher","first-page":"E360","DOI":"10.1016\/j.ejrad.2013.02.024","volume":"82","author":"Y Wang","year":"2013","unstructured":"Wang, Y. et al. Metal artifacts reduction using monochromatic images from spectral CT: Evaluation of pedicle screws in patients with scoliosis. Eur. J. Radiol. 82(8), E360\u2013E366. https:\/\/doi.org\/10.1016\/j.ejrad.2013.02.024 (2013).","journal-title":"Eur. J. Radiol."},{"issue":"7","key":"35736_CR12","doi-asserted-by":"publisher","first-page":"853","DOI":"10.1177\/0284185117731475","volume":"59","author":"Y Dong","year":"2018","unstructured":"Dong, Y. et al. Reduction of metal artifacts from unilateral hip arthroplasty on dual-energy CT with metal artifacts reduction software. Acta Radiol. 59(7), 853\u2013860. https:\/\/doi.org\/10.1177\/0284185117731475 (2018).","journal-title":"Acta Radiol."},{"issue":"3","key":"35736_CR13","doi-asserted-by":"publisher","first-page":"502","DOI":"10.3969\/j.issn.1008-1704.2021.05.010","volume":"26","author":"QX Shan","year":"2021","unstructured":"Shan, Q. X., Zhang, X. D. & Wang, X. The application single energy imaging of energy spectrum computed tomography and metal artifacts reduction algorithm in the angiography of patients with liver cirrhotic portal hypertension after trans jugular intrahepatic portosystemic stent shunt treatment. Chin. Hepatol. 26(3), 502\u2013509. https:\/\/doi.org\/10.3969\/j.issn.1008-1704.2021.05.010 (2021).","journal-title":"Chin. Hepatol."},{"issue":"6","key":"35736_CR14","doi-asserted-by":"publisher","first-page":"1370","DOI":"10.1109\/TMI.2018.2823083","volume":"37","author":"Y Zhang","year":"2018","unstructured":"Zhang, Y. & Yu, H. Convolutional neural network based metal artifacts reduction in X-ray computed tomography. IEEE Trans. Med. Imaging 37(6), 1370\u20131381. https:\/\/doi.org\/10.1109\/TMI.2018.2823083 (2018).","journal-title":"IEEE Trans. Med. Imaging"},{"issue":"1","key":"35736_CR15","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1186\/s12938-018-0609-y","volume":"17","author":"X Huang","year":"2018","unstructured":"Huang, X., Wang, J., Tang, F., Zhong, T. & Zhang, Y. Metal artifacts reduction on cervical CT images by deep residual learning. Biomed. Eng. Online 17(1), 175. https:\/\/doi.org\/10.1186\/s12938-018-0609-y (2018).","journal-title":"Biomed. Eng. Online"},{"issue":"15","key":"35736_CR16","doi-asserted-by":"publisher","first-page":"155009","DOI":"10.1088\/1361-6560\/ac1156","volume":"66","author":"T Wang","year":"2021","unstructured":"Wang, T. et al. DAN-Net: Dual-domain adaptive-scaling non-local network for CT metal artifacts reduction. Phys. Med. Biol. 66(15), 155009. https:\/\/doi.org\/10.1088\/1361-6560\/ac1156 (2021).","journal-title":"Phys. Med. Biol."},{"issue":"17","key":"35736_CR17","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1088\/1361-6560\/ac195c","volume":"66","author":"L Yu","year":"2021","unstructured":"Yu, L. et al. Metal artifact reduction in 2D CT images with self-supervised cross-domain learning. Phys. Med. Biol. 66(17), 175. https:\/\/doi.org\/10.1088\/1361-6560\/ac195c (2021).","journal-title":"Phys. Med. Biol."},{"issue":"12","key":"35736_CR18","doi-asserted-by":"publisher","first-page":"e823","DOI":"10.1002\/mp.13644","volume":"46","author":"K Liang","year":"2019","unstructured":"Liang, K. et al. Metal artifact reduction for practical dental computed tomography by improving interpolation-based reconstruction with deep learning. Med. Phys. 46(12), e823\u2013e883. https:\/\/doi.org\/10.1002\/mp.13644 (2019).","journal-title":"Med. Phys."},{"key":"35736_CR19","doi-asserted-by":"publisher","DOI":"10.2214\/AJR.18.20413","author":"YJ Kim","year":"2019","unstructured":"Kim, Y. J. et al. Dual-energy and iterative metal artifact reduction for reducing artifacts due to metallic hardware: A loosening hip phantom study. AJR Am. J. Roentgenol. https:\/\/doi.org\/10.2214\/AJR.18.20413 (2019).","journal-title":"AJR Am. J. Roentgenol."},{"issue":"1","key":"35736_CR20","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1097\/RLI.0000000000000306","volume":"52","author":"C Schabel","year":"2016","unstructured":"Schabel, C. et al. Improving CT-based PET attenuation correction in the vicinity of metal implants by an iterative metal artifact reduction algorithm of CT data and its comparison to dual-energy-based strategies: A phantom study. Investig. Radiol. 52(1), 61. https:\/\/doi.org\/10.1097\/RLI.0000000000000306 (2016).","journal-title":"Investig. Radiol."},{"issue":"7","key":"35736_CR21","doi-asserted-by":"publisher","first-page":"853","DOI":"10.1177\/0284185117731475","volume":"59","author":"YJ Kim","year":"2019","unstructured":"Kim, Y. J. et al. Dual-energy and iterative metal artifact reduction for reducing artifacts due to metallic hardware: A loosening hip phantom study. AJR Am. J. Roentgenol. 59(7), 853\u2013860. https:\/\/doi.org\/10.1177\/0284185117731475 (2019).","journal-title":"AJR Am. J. Roentgenol."},{"issue":"6","key":"35736_CR22","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1002\/acm2.13255","volume":"22","author":"P Sathyathas","year":"2021","unstructured":"Sathyathas, P. et al. The application of metal artifact reduction methods on computed tomography scans for radiotherapy applications: A literature review. J. Appl. Clin. Med. Phys. 22(6), 198\u2013223. https:\/\/doi.org\/10.1002\/acm2.13255 (2021).","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"#cr-split#-35736_CR23.1","unstructured":"Qin, H., et al. Metal artifact reduction in kVCT images via L1 sparse regularization of MVCBCT prior images. In BIBE 2019"},{"key":"#cr-split#-35736_CR23.2","unstructured":"The Third International Conference on Biological Information and Biomedical Engineering. VDE (2019)."},{"issue":"8","key":"35736_CR24","doi-asserted-by":"publisher","first-page":"4654","DOI":"10.1118\/1.4926552","volume":"42","author":"H Jeon","year":"2015","unstructured":"Jeon, H. et al. Generation of hybrid sinograms for the recovery of kVCT images with metal artifacts for helical tomotherapy. Med. Phys. 42(8), 4654\u20134667. https:\/\/doi.org\/10.1118\/1.4926552 (2015).","journal-title":"Med. Phys."},{"issue":"3","key":"35736_CR25","doi-asserted-by":"publisher","first-page":"682","DOI":"10.1016\/j.ijrobp.2014.02.040","volume":"89","author":"MR Paudel","year":"2014","unstructured":"Paudel, M. R. et al. Clinical evaluation of normalized metal artifact reduction in kVCT using MVCT prior images (MVCT-NMAR) for radiation therapy treatment planning. Int. J. Radiat. Oncol. Biol. Phys. 89(3), 682\u2013689. https:\/\/doi.org\/10.1016\/j.ijrobp.2014.02.040 (2014).","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"issue":"1","key":"35736_CR26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/srep37608","volume":"6","author":"L Gao","year":"2016","unstructured":"Gao, L. et al. Metal artifact reduction through MVCBCT and kVCT in radiotherapy. Sci. Rep. 6(1), 1\u201311. https:\/\/doi.org\/10.1038\/srep37608 (2016).","journal-title":"Sci. Rep."},{"issue":"5","key":"35736_CR27","doi-asserted-by":"publisher","first-page":"730","DOI":"10.1038\/srep37608","volume":"34","author":"G Liugang","year":"2017","unstructured":"Liugang, G. et al. Metal artifact reduction for dental implants in kilovoltage computed tomography using megavoltage cone-beam computer tomography. J. Biomed. Eng. 34(5), 730\u2013737. https:\/\/doi.org\/10.1038\/srep37608 (2017).","journal-title":"J. Biomed. Eng."},{"issue":"1","key":"35736_CR28","doi-asserted-by":"publisher","first-page":"20823","DOI":"10.1038\/s41598-022-25366-","volume":"12","author":"H Kim","year":"2022","unstructured":"Kim, H. et al. Metal artifact reduction in kV CT images throughout two-step sequential deep convolutional neural networks by combining multi-modal imaging (MARTIAN). Sci Rep. 12(1), 20823. https:\/\/doi.org\/10.1038\/s41598-022-25366- (2022).","journal-title":"Sci Rep."},{"issue":"8","key":"35736_CR29","doi-asserted-by":"publisher","first-page":"0817","DOI":"10.1118\/1.4812416","volume":"40","author":"MR Paudel","year":"2013","unstructured":"Paudel, M. R. et al. Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning. Med. Phys. 40(8), 0817. https:\/\/doi.org\/10.1118\/1.4812416 (2013).","journal-title":"Med. Phys."},{"issue":"1","key":"35736_CR30","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1109\/TSMC.1979.4310076","volume":"9","author":"N Otsu","year":"2007","unstructured":"Otsu, N. A threshold selection method from gray-level histograms. IEEE Trans. Syst. Man Cybern. 9(1), 62\u201366. https:\/\/doi.org\/10.1109\/TSMC.1979.4310076 (2007).","journal-title":"IEEE Trans. Syst. Man Cybern."},{"key":"35736_CR31","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2014\/794574","volume":"2014","author":"M Sri","year":"2014","unstructured":"Sri, M., Rajinikanth, V. & Latha, K. Otsu based optimal multilevel image thresholding using firefly algorithm. Model. Simul. Eng. 2014, 1\u201317. https:\/\/doi.org\/10.1155\/2014\/794574 (2014).","journal-title":"Model. Simul. Eng."},{"issue":"4","key":"35736_CR32","doi-asserted-by":"publisher","first-page":"1588","DOI":"10.1118\/1.4942810","volume":"43","author":"M Abdoli","year":"2016","unstructured":"Abdoli, M., Mehranian, A., Ailianou, A., Becker, M. & Zaidi, H. Assessment of metal artifact reduction methods in pelvic CT. Med Phys. 43(4), 1588. https:\/\/doi.org\/10.1118\/1.4942810 (2016).","journal-title":"Med Phys."},{"key":"35736_CR33","doi-asserted-by":"publisher","first-page":"1061","DOI":"10.1002\/jmri.22234","volume":"32","author":"Y Ohgiya","year":"2010","unstructured":"Ohgiya, Y. et al. MRI of the neck at 3 Tesla using the periodically rotated overlapping parallel lines with enhanced reconstruction (propeller)(blade) sequence compared with t2-weighted fast spin-echo sequence. J. Magn. Reson. Imaging 32, 1061\u20131067 (2010).","journal-title":"J. Magn. Reson. Imaging"},{"issue":"3","key":"35736_CR34","first-page":"502","volume":"26","author":"QX Shan","year":"2021","unstructured":"Shan, Q. X., Zhang, X. D. & Wang, X. The application single energy imaging of energy spectrum computed tomography and metal artifact reduction algorithm in the angiography of patients with liver cirrhotic portal hypertension after trans jugular intrahepatic portosystemic stent shunt treatment. Chin. Hepatol. 26(3), 502\u2013509 (2021).","journal-title":"Chin. Hepatol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-35736-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-35736-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-35736-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,2]],"date-time":"2023-06-02T10:13:08Z","timestamp":1685700788000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-35736-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,2]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["35736"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-35736-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,2]]},"assertion":[{"value":"11 January 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 May 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 June 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"8970"}}