{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,4]],"date-time":"2025-11-04T23:53:06Z","timestamp":1762300386719,"version":"build-2065373602"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,6,15]],"date-time":"2023-06-15T00:00:00Z","timestamp":1686787200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,6,15]],"date-time":"2023-06-15T00:00:00Z","timestamp":1686787200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"The Science Fund for Distinguished Young Scholars of Xinjiang Uygur Autonomous Region","award":["2022D01E22"],"award-info":[{"award-number":["2022D01E22"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>To assess pacing and electrophysiological parameters, as well as mid-term outcomes, among patients undergoing His bundle pacing (HBP) guided by KODEX-EPD (a novel mapping system). Consecutive patients undergoing conduction system pacing (CSP) for bradycardia indications were evaluated. Procedural and fluoroscopic times and pacing characteristics were compared between conventional fluoroscopy (the standard group, N\u2009=\u200920 cases) and KODEX-EPD mapping system guided group (the KODEX group, N\u2009=\u200920cases) at CSP implantation and all patients were followed at 6-month. HBP was achieved in all patients (the standard group 20\/20 and the KODEX group 20\/20). There was no difference in the mean procedure time between the two groups (63.7\u2009\u00b1\u20099.3 vs. 78.2\u2009\u00b1\u200925.1\u00a0min, <jats:italic>p<\/jats:italic>\u2009=\u20090.33). Compared with the standard group, the KODEX group significantly reduced the intraoperative X-ray exposure time (3.8\u2009\u00b1\u20090.5 vs. 19.3\u2009\u00b1\u20095.1\u00a0min, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05) and X-ray dose (23.6\u2009\u00b1\u20095.4 vs. 120.2\u2009\u00b1\u200938.3\u00a0mGy, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05). There were no significant differences in atrial impedance (643.0\u2009\u00b1\u200998.8 vs. 591.5\u2009\u00b1\u200992.1\u00a0\u03a9, <jats:italic>p<\/jats:italic>\u2009=\u20090.09), atrial sensing (2.9\u2009\u00b1\u20090.8 vs. 2.5\u2009\u00b1\u20090.8\u00a0mV, <jats:italic>p<\/jats:italic>\u2009=\u20090.08), ventricular sensing (12.8\u2009\u00b1\u20092.4 vs. 13.3\u2009\u00b1\u20093.3\u00a0mV, <jats:italic>p<\/jats:italic>\u2009=\u20090.63),atrial pacing threshold (1.0\u2009\u00b1\u20090.2 vs. 1.0\u2009\u00b1\u20090.1\u00a0V\/0.4\u00a0ms, <jats:italic>p<\/jats:italic>\u2009=\u20090.81) and ventricular pacing threshold (1.0\u2009\u00b1\u20090.2 vs. 0.9\u2009\u00b1\u20090.1\u00a0V\/0.4\u00a0ms, <jats:italic>p<\/jats:italic>\u2009=\u20090.63) between two groups, There were statistical differences in ventricular impedance (640.0\u2009\u00b1\u200980.3 vs. 702.0\u2009\u00b1\u200986.1\u00a0\u03a9, <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.05). There was no statistical significance in pacing parameters between the two groups at 6\u00a0months after procedure (<jats:italic>p<\/jats:italic>\u2009&gt;\u20090.05). During the 6-months follow-up period, no adverse events occurred in the two groups. It can be concluded that KODEX-EPD can safely guide His bundle branch pacing lead implantation with reduced fluoroscopic time and dose without lengthening the procedure time.\n<\/jats:p>","DOI":"10.1038\/s41598-023-36546-x","type":"journal-article","created":{"date-parts":[[2023,6,15]],"date-time":"2023-06-15T10:02:19Z","timestamp":1686823339000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Feasibility, safety and effectiveness of mapping system assisted conduction system pacing: a single-center prospective study"],"prefix":"10.1038","volume":"13","author":[{"given":"Liang","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suxia","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Baopeng","family":"Tang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Feifei","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wanyue","family":"Sang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yafan","family":"Han","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lu","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xianhui","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianghua","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qiang","family":"Xing","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zukela","family":"Tuerhong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jiasuoer","family":"Xiaokereti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yankai","family":"Guo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yaodong","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,6,15]]},"reference":[{"issue":"25","key":"36546_CR1","doi-asserted-by":"publisher","first-page":"3099","DOI":"10.1016\/j.jacc.2017.05.005","volume":"69","author":"P Vijayaraman","year":"2017","unstructured":"Vijayaraman, P., Bordachar, P. & Ellenbogen, K. A. The continued search for physiological pacing: Where are we now?. J. Am. Coll. Cardiol. 69(25), 3099\u20133114 (2017).","journal-title":"J. Am. Coll. Cardiol."},{"issue":"3","key":"36546_CR2","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1016\/j.hrthm.2017.10.039","volume":"15","author":"P Vijayaraman","year":"2018","unstructured":"Vijayaraman, P. et al. Permanent his bundle pacing: Recommendations from a multicenter his bundle pacing collaborative working group for standardization of definitions, implant measurements, and follow-up. Heart Rhythm 15(3), 460\u2013468 (2018).","journal-title":"Heart Rhythm"},{"key":"36546_CR3","doi-asserted-by":"publisher","first-page":"849143","DOI":"10.3389\/fcvm.2022.849143","volume":"9","author":"W Zhuo","year":"2022","unstructured":"Zhuo, W. et al. Pacing characteristics of his bundle pacing vs. left bundle branch pacing: A systematic review and meta-analysis. Front. Cardiovasc. Med. 9, 849143 (2022).","journal-title":"Front. Cardiovasc. Med."},{"issue":"12","key":"36546_CR4","doi-asserted-by":"publisher","first-page":"1736e1","DOI":"10.1016\/j.cjca.2017.09.013","volume":"33","author":"W Huang","year":"2017","unstructured":"Huang, W. et al. A novel pacing strategy with low and stable output: Pacing the left bundle branch immediately beyond the conduction block. Can. J. Cardiol. 33(12), 1736e1-1737e3 (2017).","journal-title":"Can. J. Cardiol."},{"issue":"9","key":"36546_CR5","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1016\/j.hrcr.2020.06.008","volume":"6","author":"V Ravi","year":"2020","unstructured":"Ravi, V. et al. Late-onset interventricular septal perforation from left bundle branch pacing. HeartRhythm Case Rep. 6(9), 627\u2013631 (2020).","journal-title":"HeartRhythm Case Rep."},{"issue":"8","key":"36546_CR6","doi-asserted-by":"publisher","first-page":"1318","DOI":"10.1016\/j.hrthm.2021.04.015","volume":"18","author":"X Liu","year":"2021","unstructured":"Liu, X. et al. Contrast-enhanced image-guided lead deployment for left bundle branch pacing. Heart Rhythm 18(8), 1318\u20131325 (2021).","journal-title":"Heart Rhythm"},{"issue":"10","key":"36546_CR7","doi-asserted-by":"publisher","first-page":"e008370","DOI":"10.1161\/CIRCEP.120.008370","volume":"13","author":"M Gu","year":"2020","unstructured":"Gu, M. et al. Permanent his bundle pacing implantation facilitated by visualization of the tricuspid valve annulus. Circ. Arrhythm. Electrophysiol. 13(10), e008370 (2020).","journal-title":"Circ. Arrhythm. Electrophysiol."},{"issue":"2","key":"36546_CR8","doi-asserted-by":"publisher","first-page":"e006801","DOI":"10.1161\/CIRCEP.118.006801","volume":"12","author":"MV Orlov","year":"2019","unstructured":"Orlov, M. V. et al. Direct visualization of the his bundle pacing lead placement by 3-dimensional electroanatomic mapping: Technique, anatomy, and practical considerations. Circ. Arrhythm. Electrophysiol. 12(2), e006801 (2019).","journal-title":"Circ. Arrhythm. Electrophysiol."},{"key":"36546_CR9","doi-asserted-by":"publisher","first-page":"712051","DOI":"10.3389\/fcvm.2021.712051","volume":"8","author":"W Hua","year":"2021","unstructured":"Hua, W. et al. Novel wide-band dielectric imaging system guided lead deployment for his bundle pacing: A feasibility study. Front. Cardiovasc. Med. 8, 712051 (2021).","journal-title":"Front. Cardiovasc. Med."},{"issue":"8","key":"36546_CR10","first-page":"e382","volume":"140","author":"FM Kusumoto","year":"2019","unstructured":"Kusumoto, F. M. et al. 2018 ACC\/AHA\/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay: A report of the American college of cardiology\/american heart association task force on clinical practice guidelines and the heart rhythm society. Circulation 140(8), e382\u2013e482 (2019).","journal-title":"Circulation"},{"issue":"11","key":"36546_CR11","doi-asserted-by":"publisher","first-page":"1819","DOI":"10.1093\/europace\/euy058","volume":"20","author":"F Zanon","year":"2018","unstructured":"Zanon, F. et al. Permanent His-bundle pacing: A systematic literature review and meta-analysis. Europace 20(11), 1819\u20131826 (2018).","journal-title":"Europace"},{"issue":"12","key":"36546_CR12","doi-asserted-by":"publisher","first-page":"1883","DOI":"10.1016\/j.hrthm.2019.06.020","volume":"16","author":"A Romanov","year":"2019","unstructured":"Romanov, A. et al. High-resolution, real-time, and nonfluoroscopic 3-dimensional cardiac imaging and catheter navigation in humans using a novel dielectric-based system. Heart Rhythm 16(12), 1883\u20131889 (2019).","journal-title":"Heart Rhythm"},{"issue":"14","key":"36546_CR13","doi-asserted-by":"publisher","first-page":"1311","DOI":"10.1161\/CIRCULATIONAHA.115.016871","volume":"132","author":"A Luik","year":"2015","unstructured":"Luik, A. et al. Cryoballoon versus open irrigated radiofrequency ablation in patients with paroxysmal atrial fibrillation: The prospective, randomized, controlled, noninferiority FreezeAF study. Circulation 132(14), 1311\u20131319 (2015).","journal-title":"Circulation"},{"issue":"1","key":"36546_CR14","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1111\/pace.14130","volume":"44","author":"FM Cauti","year":"2021","unstructured":"Cauti, F. M. et al. Occlusion tool software for pulmonary vein occlusion verification in atrial fibrillation cryoballoon ablation. Pacing Clin. Electrophysiol. 44(1), 63\u201370 (2021).","journal-title":"Pacing Clin. Electrophysiol."},{"issue":"8","key":"36546_CR15","doi-asserted-by":"publisher","first-page":"e008507","DOI":"10.1161\/CIRCEP.120.008507","volume":"13","author":"L Rottner","year":"2020","unstructured":"Rottner, L. et al. Wide-band dielectric imaging and the novel cryoballoon-occlusion tool to guide cryoballoon-based pulmonary vein isolation. Circ. Arrhythm. Electrophysiol. 13(8), e008507 (2020).","journal-title":"Circ. Arrhythm. Electrophysiol."},{"issue":"9","key":"36546_CR16","doi-asserted-by":"publisher","first-page":"1504","DOI":"10.1111\/pace.14324","volume":"44","author":"L Rottner","year":"2021","unstructured":"Rottner, L. et al. High anatomical accuracy of a novel high-resolution wide-band dielectric imaging system in cryoballoon-based ablation. Pacing Clin. Electrophysiol. 44(9), 1504\u20131515 (2021).","journal-title":"Pacing Clin. Electrophysiol."},{"key":"36546_CR17","doi-asserted-by":"publisher","first-page":"1033755","DOI":"10.3389\/fcvm.2022.1033755","volume":"9","author":"K Janosi","year":"2022","unstructured":"Janosi, K. et al. Visualizable vs. standard, non-visualizable steerable sheath for pulmonary vein isolation procedures: Randomized, single-centre trial. Front. Cardiovasc. Med. 9, 1033755 (2022).","journal-title":"Front. Cardiovasc. Med."},{"issue":"11","key":"36546_CR18","doi-asserted-by":"publisher","first-page":"1344","DOI":"10.1016\/j.jacep.2019.06.020","volume":"5","author":"T Maurer","year":"2019","unstructured":"Maurer, T. et al. High-resolution imaging of LA anatomy using a novel wide-band dielectric mapping system: First clinical experience. JACC Clin. Electrophysiol. 5(11), 1344\u20131354 (2019).","journal-title":"JACC Clin. Electrophysiol."},{"issue":"1","key":"36546_CR19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s42444-020-00019-3","volume":"21","author":"V Schillaci","year":"2020","unstructured":"Schillaci, V. et al. Utility of a new imaging system for displaying complex anatomy during AF ablation with cryoenergy. Int. J. Arrhythm. 21(1), 1\u20133 (2020).","journal-title":"Int. J. Arrhythm."},{"issue":"5","key":"36546_CR20","doi-asserted-by":"publisher","first-page":"1383","DOI":"10.1002\/joa3.12627","volume":"37","author":"A Scara","year":"2021","unstructured":"Scara, A. et al. Cardiac resynchronization therapy guided by the new KODEX-EPD imaging system. J. Arrhythm. 37(5), 1383\u20131387 (2021).","journal-title":"J. Arrhythm."},{"issue":"8","key":"36546_CR21","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.hrcr.2019.06.003","volume":"5","author":"W Hua","year":"2019","unstructured":"Hua, W. et al. A feasible approach for His bundle pacing using a novel mapping system in patients receiving pacemaker therapy. HeartRhythm Case Rep. 5(8), 433\u2013435 (2019).","journal-title":"HeartRhythm Case Rep."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-36546-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-36546-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-36546-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,15]],"date-time":"2023-06-15T10:09:07Z","timestamp":1686823747000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-36546-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,15]]},"references-count":21,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["36546"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-36546-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"type":"electronic","value":"2045-2322"}],"subject":[],"published":{"date-parts":[[2023,6,15]]},"assertion":[{"value":"28 January 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 June 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 June 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"9683"}}