{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T03:23:15Z","timestamp":1787973795787,"version":"build-2784847793"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,6,14]],"date-time":"2023-06-14T00:00:00Z","timestamp":1686700800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,6,14]],"date-time":"2023-06-14T00:00:00Z","timestamp":1686700800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100007655","name":"\u010cesk\u00e9 Vysok\u00e9 U\u010den\u00ed Technick\u00e9 v Praze","doi-asserted-by":"publisher","award":["SGS22\/203\/OHK4\/3T\/17"],"award-info":[{"award-number":["SGS22\/203\/OHK4\/3T\/17"]}],"id":[{"id":"10.13039\/100007655","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100009553","name":"Agentura Pro Zdravotnick\u00fd V\u00fdzkum \u010cesk\u00e9 Republiky","doi-asserted-by":"publisher","award":["NV18-02-00080"],"award-info":[{"award-number":["NV18-02-00080"]}],"id":[{"id":"10.13039\/501100009553","id-type":"DOI","asserted-by":"publisher"}]},{"name":"European Union - Next Generation EU","award":["LX22NPO5104"],"award-info":[{"award-number":["LX22NPO5104"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Inverse ECG imaging methods typically require 32\u2013250 leads to create body surface potential maps (BSPM), limiting their routine clinical use. This study evaluated the accuracy of <jats:italic>PaceView<\/jats:italic> inverse ECG method to localize the left or right ventricular (LV and RV, respectively) pacing leads using either a 99-lead BSPM or the 12-lead ECG. A 99-lead BSPM was recorded in patients with cardiac resynchronization therapy (CRT) during sinus rhythm and sequential LV\/RV pacing. The non-contrast CT was performed to localize precisely both ECG electrodes and CRT leads. From a BSPM, nine signals were selected to obtain the 12-lead ECG. Both BSPM and 12-lead ECG were used to localize the RV and LV lead, and the localization error was calculated. Consecutive patients with dilated cardiomyopathy, previously implanted with a CRT device, were enrolled (n\u2009=\u200919). The localization error for the RV\/LV lead was 9.0 [IQR 4.8\u201313.6] \/ 7.7 [IQR 0.0\u201310.3] mm using the 12-lead ECG and 9.1 [IQR 5.4\u201315.7] \/ 9.8 [IQR 8.6\u201313.1] mm for the BSPM. Thus, the noninvasive lead localization using the 12-lead ECG was accurate enough and comparable to 99-lead BSPM, potentially increasing the capability of 12-lead ECG for the optimization of the LV\/RV pacing sites during CRT implant or for the most favorable programming.<\/jats:p>","DOI":"10.1038\/s41598-023-36768-z","type":"journal-article","created":{"date-parts":[[2023,6,14]],"date-time":"2023-06-14T10:02:36Z","timestamp":1686736956000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Localization of the ventricular pacing site from BSPM and standard 12-lead ECG: a comparison study"],"prefix":"10.1038","volume":"13","author":[{"given":"Ksenia A.","family":"Sedova","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter M.","family":"van Dam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marie","family":"Blahova","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucie","family":"Necasova","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josef","family":"Kautzner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,6,14]]},"reference":[{"issue":"21","key":"36768_CR1","doi-asserted-by":"publisher","first-page":"2588","DOI":"10.1016\/j.jacc.2019.09.043","volume":"74","author":"N Varma","year":"2019","unstructured":"Varma, N. et al. Evaluation, management, and outcomes of patients poorly responsive to cardiac resynchronization device therapy. J. Am. Coll. Cardiol. 74(21), 2588\u20132603 (2019).","journal-title":"J. Am. Coll. Cardiol."},{"issue":"11","key":"36768_CR2","doi-asserted-by":"publisher","first-page":"1159","DOI":"10.1161\/CIRCULATIONAHA.110.000646","volume":"123","author":"JP Singh","year":"2011","unstructured":"Singh, J. P. et al. Left ventricular lead position and clinical outcome in the multicenter automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT) trial. Circulation 123(11), 1159\u20131166 (2011).","journal-title":"Circulation"},{"issue":"4","key":"36768_CR3","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1016\/j.hrthm.2014.12.031","volume":"12","author":"S Ploux","year":"2015","unstructured":"Ploux, S. et al. Electrical dyssynchrony induced by biventricular pacing: implications for patient selection and therapy improvement. Heart Rhythm 12(4), 782\u2013791 (2015).","journal-title":"Heart Rhythm"},{"issue":"3","key":"36768_CR4","doi-asserted-by":"publisher","first-page":"385","DOI":"10.1016\/j.hrthm.2016.11.017","volume":"14","author":"WB Johnson","year":"2017","unstructured":"Johnson, W. B. et al. Body surface mapping using an ECG belt to characterize electrical heterogeneity for different left ventricular pacing sites during cardiac resynchronization: Relationship with acute hemodynamic improvement. Heart Rhythm 14(3), 385\u2013391 (2017).","journal-title":"Heart Rhythm"},{"key":"36768_CR5","doi-asserted-by":"crossref","first-page":"iv16","DOI":"10.1093\/europace\/18.suppl_1.i182a","volume":"18","author":"PM van Dam","year":"2016","unstructured":"van Dam, P. M., Boyle, N. G., Laks, M. M. & Tung, R. Localization of premature ventricular contractions from the papillary muscles using the standard 12-lead electrocardiogram: A feasibility study using a novel cardiac isochrone positioning system. Europace 18, iv16\u2013iv22 (2016).","journal-title":"Europace"},{"issue":"5","key":"36768_CR6","doi-asserted-by":"publisher","first-page":"801","DOI":"10.1016\/j.jelectrocard.2018.05.018","volume":"51","author":"S Misra","year":"2018","unstructured":"Misra, S. et al. Initial validation of a novel ECGI system for localization of premature ventricular contractions and ventricular tachycardia in structurally normal and abnormal hearts. J. Electrocardiol. 51(5), 801\u2013808 (2018).","journal-title":"J. Electrocardiol."},{"key":"36768_CR7","doi-asserted-by":"publisher","first-page":"870435","DOI":"10.3389\/fphys.2022.870435","volume":"13","author":"K Lesina","year":"2022","unstructured":"Lesina, K. et al. Performance and robustness testing of a non-invasive mapping system for ventricular arrhythmias. Front. Physiol. 13, 870435 (2022).","journal-title":"Front. Physiol."},{"key":"36768_CR8","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.jelectrocard.2023.01.015","volume":"78","author":"JR Griffiths","year":"2023","unstructured":"Griffiths, J. R. et al. Non-invasive electrocardiographic mapping on the ward to guide ablation of premature ventricular contractions. J. Electrocardiol. 78, 65\u201368 (2023).","journal-title":"J. Electrocardiol."},{"key":"36768_CR9","doi-asserted-by":"publisher","first-page":"1087568","DOI":"10.3389\/fcvm.2023.1087568","volume":"10","author":"PZ Fruelund","year":"2023","unstructured":"Fruelund, P. Z. et al. Novel non-invasive ECG imaging method based on the 12-lead ECG for reconstruction of ventricular activation: A proof-of-concept study. Front. Cardiovasc. Med. 10, 1087568 (2023).","journal-title":"Front. Cardiovasc. Med."},{"key":"36768_CR10","doi-asserted-by":"publisher","first-page":"730","DOI":"10.3389\/fphys.2021.730736","volume":"12","author":"RW Roudijk","year":"2021","unstructured":"Roudijk, R. W. et al. Comparing non-invasive inverse electrocardiography with invasive endocardial and epicardial electroanatomical mapping during sinus rhythm. Front. Physiol. 12, 730\u2013736 (2021).","journal-title":"Front. Physiol."},{"issue":"6","key":"36768_CR11","first-page":"57","volume":"7","author":"V Rosik","year":"2007","unstructured":"Rosik, V., Karas, S., Heblakova, E., Tysler, M. & Filipova, S. Portable device for high resolution ECG mapping. Meas. Sci. Rev. 7(6), 57\u201361 (2007).","journal-title":"Meas. Sci. Rev."},{"issue":"6","key":"36768_CR12","doi-asserted-by":"publisher","first-page":"959","DOI":"10.1016\/j.jelectrocard.2015.08.036","volume":"48","author":"PM van Dam","year":"2015","unstructured":"van Dam, P. M., Gordon, J. P., Laks, M. M. & Boyle, N. G. Development of new anatomy reconstruction software to localize cardiac isochrones to the cardiac surface from the 12 lead ECG. J. Electrocardiol. 48(6), 959\u2013965 (2015).","journal-title":"J. Electrocardiol."},{"issue":"Suppl","key":"36768_CR13","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1054\/jelc.2001.28896","volume":"34","author":"A van Oosterom","year":"2001","unstructured":"van Oosterom, A. Genesis of the T wave as based on an equivalent surface source model. J. Electrocardiol. 34(Suppl), 217\u2013227 (2001).","journal-title":"J. Electrocardiol."},{"issue":"6","key":"36768_CR14","doi-asserted-by":"publisher","first-page":"1013","DOI":"10.1007\/s11517-017-1715-x","volume":"56","author":"AM Janssen","year":"2018","unstructured":"Janssen, A. M., Potyagaylo, D., D\u00f6ssel, O. & Oostendorp, T. F. Assessment of the equivalent dipole layer source model in the reconstruction of cardiac activation times on the basis of BSPMs produced by an anisotropic model of the heart. Med. Biol. Eng. Comput. 56(6), 1013\u20131025 (2018).","journal-title":"Med. Biol. Eng. Comput."},{"issue":"6","key":"36768_CR15","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1109\/5.29327","volume":"77","author":"DB Geselowitz","year":"1989","unstructured":"Geselowitz, D. B. On the Theory of the electrocardiogram. Proc. IEEE 77(6), 857\u2013876 (1989).","journal-title":"Proc. IEEE"},{"issue":"Suppl","key":"36768_CR16","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/0022-0736(92)90063-6","volume":"25","author":"DB Geselowitz","year":"1992","unstructured":"Geselowitz, D. B. Description of cardiac sources in anisotropic cardiac muscle. Application of bidomain model. J. Electrocardiol. 25(Suppl), 65\u201367 (1992).","journal-title":"J. Electrocardiol."},{"key":"36768_CR17","doi-asserted-by":"publisher","first-page":"1038","DOI":"10.1109\/10.40805","volume":"36","author":"JW Meijs","year":"1989","unstructured":"Meijs, J. W., Weier, O. W., Peters, M. J. & van Oosterom, A. On the numerical accuracy of the boundary element method. IEEE Trans. Biomed. Eng. 36, 1038\u20131049 (1989).","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"9","key":"36768_CR18","doi-asserted-by":"publisher","first-page":"1739","DOI":"10.1007\/s10439-009-9747-5","volume":"37","author":"PM van Dam","year":"2009","unstructured":"van Dam, P. M., Oostendorp, T. F., Linnenbank, A. C. & van Oosterom, A. Non-invasive imaging of cardiac activation and recovery. Ann. Biomed. Eng. 37(9), 1739\u20131756 (2009).","journal-title":"Ann. Biomed. Eng."},{"issue":"1","key":"36768_CR19","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1007\/s11517-008-0391-2","volume":"47","author":"PM van Dam","year":"2009","unstructured":"van Dam, P. M., Oostendorp, T. F. & van Oosterom, A. Application of the fastest route algorithm in the interactive simulation of the effect of local ischemia on the ECG. Med. Biol. Eng. Comput. 47(1), 11\u201320 (2009).","journal-title":"Med. Biol. Eng. Comput."},{"issue":"8","key":"36768_CR20","doi-asserted-by":"publisher","first-page":"e004104","DOI":"10.1161\/CIRCEP.116.004104","volume":"9","author":"P Oosterhoff","year":"2016","unstructured":"Oosterhoff, P. et al. Experimental validation of noninvasive epicardial and endocardial activation imaging. Circ. Arrhythm. Electrophysiol. 9(8), e004104 (2016).","journal-title":"Circ. Arrhythm. Electrophysiol."},{"issue":"3","key":"36768_CR21","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1007\/s10439-022-02905-4","volume":"50","author":"MJ Boonstra","year":"2022","unstructured":"Boonstra, M. J. et al. Modeling the His-Purkinje effect in non-invasive estimation of endocardial and epicardial ventricular activation. Ann. Biomed. Eng. 50(3), 343\u2013359 (2022).","journal-title":"Ann. Biomed. Eng."},{"key":"36768_CR22","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1161\/01.CIR.41.6.899","volume":"41","author":"D Durrer","year":"1970","unstructured":"Durrer, D. et al. Total excitation of the isolated human heart. Circulation 41, 899\u2013912 (1970).","journal-title":"Circulation"},{"issue":"2","key":"36768_CR23","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.hrthm.2016.10.010","volume":"14","author":"T Opthof","year":"2017","unstructured":"Opthof, T. et al. Cardiac activation-repolarization patterns and ion channel expression mapping in intact isolated normal human hearts. Heart Rhythm 14(2), 265\u2013272 (2017).","journal-title":"Heart Rhythm"},{"key":"36768_CR24","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.jelectrocard.2021.07.014","volume":"69","author":"PM van Dam","year":"2021","unstructured":"van Dam, P. M., Boonstra, M., Locati, E. T. & Loh, P. The relation of 12-lead ECG to the cardiac anatomy: The normal CineECG. J. Electrocardiol. 69, 67\u201374 (2021).","journal-title":"J. Electrocardiol."},{"issue":"1","key":"36768_CR25","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.hrthm.2014.08.029","volume":"12","author":"MM Sadek","year":"2015","unstructured":"Sadek, M. M. et al. Idiopathic ventricular arrhythmias originating from the moderator band: Electrocardiographic characteristics and treatment by catheter ablation. Heart Rhythm 12(1), 67\u201375 (2015).","journal-title":"Heart Rhythm"},{"issue":"5","key":"36768_CR26","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1016\/j.hrthm.2011.01.017","volume":"8","author":"S Ghosh","year":"2011","unstructured":"Ghosh, S. et al. Electrophysiologic substrate and intraventricular left ventricular dyssynchrony in nonischemic heart failure patients undergoing cardiac resynchronization therapy. Heart Rhythm 8(5), 692\u2013699 (2011).","journal-title":"Heart Rhythm"},{"issue":"24","key":"36768_CR27","doi-asserted-by":"publisher","first-page":"2435","DOI":"10.1016\/j.jacc.2013.01.093","volume":"61","author":"S Ploux","year":"2013","unstructured":"Ploux, S. et al. Noninvasive electrocardiographic mapping to improve patient selection for cardiac resynchronization therapy: Beyond QRS duration and left bundle branch block morphology. J. Am. Coll. Cardiol. 61(24), 2435\u20132443 (2013).","journal-title":"J. Am. Coll. Cardiol."},{"issue":"3","key":"36768_CR28","doi-asserted-by":"publisher","first-page":"375","DOI":"10.1016\/j.jelectrocard.2016.02.011","volume":"49","author":"F Dawoud","year":"2016","unstructured":"Dawoud, F. et al. Non-invasive electromechanical activation imaging as a tool to study left ventricular dyssynchronous patients: Implication for CRT therapy. J. Electrocardiol. 49(3), 375\u2013382 (2016).","journal-title":"J. Electrocardiol."},{"issue":"4","key":"36768_CR29","doi-asserted-by":"publisher","first-page":"640","DOI":"10.1093\/europace\/euaa330","volume":"23","author":"S Pezzuto","year":"2021","unstructured":"Pezzuto, S. et al. Reconstruction of three-dimensional biventricular activation based on the 12-lead electrocardiogram via patient-specific modelling. Europace 23(4), 640\u2013647 (2021).","journal-title":"Europace"},{"key":"36768_CR30","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1016\/j.hrthm.2005.11.025","volume":"3","author":"P Jia","year":"2006","unstructured":"Jia, P. et al. Electrocardiographic imaging of cardiac resynchronization therapy in heart failure: Observation of variable electrophysiologic responses. Heart Rhythm 3, 296\u2013310 (2006).","journal-title":"Heart Rhythm"},{"key":"36768_CR31","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1016\/j.hrthm.2004.12.022","volume":"2","author":"RN Ghanem","year":"2005","unstructured":"Ghanem, R. N. et al. Noninvasive electrocardiographic imaging (ECGI): Comparison to intraoperative mapping in patients. Heart Rhythm 2, 339\u2013354 (2005).","journal-title":"Heart Rhythm"},{"issue":"5","key":"36768_CR32","doi-asserted-by":"publisher","first-page":"e006108","DOI":"10.1161\/CIRCEP.117.006108","volume":"11","author":"LR Bear","year":"2018","unstructured":"Bear, L. R. et al. How accurate is inverse electrocardiographic mapping? A systematic in vivo evaluation. Circ. Arrhythm. Electrophysiol. 11(5), e006108 (2018).","journal-title":"Circ. Arrhythm. Electrophysiol."},{"key":"36768_CR33","doi-asserted-by":"publisher","first-page":"1622","DOI":"10.1109\/TMI.2008.929094","volume":"27","author":"C Han","year":"2008","unstructured":"Han, C., Liu, Z., Zhang, X., Pogwizd, S. & He, B. Noninvasive three-dimensional cardiac activation imaging from body surface potential maps: A computational and experimental study on a rabbit model. IEEE Trans. Med. Imaging 27, 1622\u20131630 (2008).","journal-title":"IEEE Trans. Med. Imaging"},{"key":"36768_CR34","first-page":"232","volume":"3","author":"MJM Cluitmans","year":"2017","unstructured":"Cluitmans, M. J. M. et al. In vivo validation of electrocardiographic imaging. JACC EP 3, 232\u2013242 (2017).","journal-title":"JACC EP"},{"key":"36768_CR35","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1016\/j.pcad.2021.04.002","volume":"66","author":"F Ali-Ahmed","year":"2021","unstructured":"Ali-Ahmed, F. et al. Right ventricular lead location and outcomes among patients with cardiac resynchronization therapy: A meta-analysis. Prog. Cardiovasc. Dis. 66, 53\u201360 (2021).","journal-title":"Prog. Cardiovasc. Dis."},{"issue":"4","key":"36768_CR36","doi-asserted-by":"publisher","first-page":"626","DOI":"10.1093\/europace\/euy292","volume":"21","author":"UC Nguyen","year":"2019","unstructured":"Nguyen, U. C. et al. Integration of cardiac magnetic resonance imaging, electrocardiographic imaging, and coronary venous computed tomography angiography for guidance of left ventricular lead positioning. Europace 21(4), 626\u2013635 (2019).","journal-title":"Europace"},{"key":"36768_CR37","doi-asserted-by":"publisher","first-page":"1282","DOI":"10.1093\/europace\/euu339","volume":"17","author":"AS Revishvili","year":"2015","unstructured":"Revishvili, A. S. et al. Validation of the mapping accuracy of a novel non-invasive epicardial and endocardial electrophysiology system. Europace 17, 1282\u20131288 (2015).","journal-title":"Europace"},{"key":"36768_CR38","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.jelectrocard.2022.10.013","volume":"76","author":"M Boonstra","year":"2023","unstructured":"Boonstra, M. et al. ECG-based techniques to enhance clinical practice in cardiac genetic disease management. J. Electrocardiol. 76, 55\u201360 (2023).","journal-title":"J. Electrocardiol."},{"issue":"17","key":"36768_CR39","doi-asserted-by":"publisher","first-page":"1509","DOI":"10.1016\/j.jacc.2011.12.030","volume":"59","author":"FZ Khan","year":"2012","unstructured":"Khan, F. Z. et al. Targeted left ventricular lead placement to guide cardiac resynchronization therapy: The TARGET study: A randomized, controlled trial. J. Am. Coll. Cardiol. 59(17), 1509\u20131518 (2012).","journal-title":"J. Am. Coll. Cardiol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-36768-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-36768-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-36768-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,14]],"date-time":"2023-06-14T10:07:03Z","timestamp":1686737223000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-36768-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,14]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["36768"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-36768-z","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,14]]},"assertion":[{"value":"31 December 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 June 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 June 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"J.K. reports personal fees from Biosense Webster, Boehringer Ingelheim, Medtronic, Organon, and St. Jude Medical (Abbott) for participation in scientific advisory boards. He has received speaker honoraria from Bayer, Biosense Webster, Biotronik, Boehringer Ingelheim, CathVision, Medtronic, Mylan, Novartis, Organon, Pfizer, ProMed CS, and St. Jude Medical (Abbott). P.M.D. is owner of Peacs BV and ECG Excellence BV. Other authors have nothing to declare.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"9618"}}