{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,20]],"date-time":"2026-02-20T21:01:59Z","timestamp":1771621319406,"version":"3.50.1"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,6,22]],"date-time":"2023-06-22T00:00:00Z","timestamp":1687392000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,6,22]],"date-time":"2023-06-22T00:00:00Z","timestamp":1687392000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"The Key Research and Development Projects of Shaanxi Province, China","award":["2022SF-440"],"award-info":[{"award-number":["2022SF-440"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Our objective was to provide a method for selecting reference beam model and evaluating the dosimetric accuracy of volumetric modulated arc therapy (VMAT) plans delivered on three Elekta beam-matched linacs during radiation oncology. Beam data was measured on three beam-matched linacs including Synergy1, Synergy2 and VersaHD. For eighteen lung and esophagus cases, fifty-four plans were generated using VMAT technique with three linac beam models respectively for point dose measurement and three-dimensional dose measurement. Each VMAT plan was executed sequentially on three linacs respectively. Measurement results were compared with treatment planning system (TPS) calculation results for all VMAT plans. Among three beam-matched linacs, discrepancy in beam output factor, percentage depth dose at 5\u00a0cm, 10\u00a0cm, 20\u00a0cm depth and MLC leaf offset are all within 1% except 20\u2009\u00d7\u200920\u00a0cm<jats:sup>2<\/jats:sup>and 30\u2009\u00d7\u200930\u00a0cm<jats:sup>2<\/jats:sup>field sizes, and discrepancy in beam profile is all within 2%. With comparison between measurement result and TPS calculation result, the absolute dose deviations are within the range of\u2009\u00b1\u20093%, and the gamma passing rates are all over 95% for all VMAT plans, which are within the tolerance of clinical acceptability. Compared with all plans delivered on Synegy1 and VersaHD, the point dose discrepancy between measured results and TPS calculated results for plans delivered on Synergy2 is smallest, and the gamma passing rate between measured results and TPS calculated results for plans delivered on Synergy2 is highest. The beam-matched linacs demonstrate good agreement between measurement result and TPS calculation result for VMAT plans. The method can be used for selecting reference beam model for VMAT plans.<\/jats:p>","DOI":"10.1038\/s41598-023-36930-7","type":"journal-article","created":{"date-parts":[[2023,6,22]],"date-time":"2023-06-22T11:32:41Z","timestamp":1687433561000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["A method for selecting reference beam model of VMAT plans with three 6MV beam-matched linear accelerators during radiation oncology"],"prefix":"10.1038","volume":"13","author":[{"given":"Yi","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenjing","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Yuan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Linyan","family":"Chai","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fengwen","family":"Tang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruixin","family":"He","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yongkai","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yuemei","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yongkai","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Long","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mengfei","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiaozhi","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Long","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,6,22]]},"reference":[{"key":"36930_CR1","doi-asserted-by":"publisher","first-page":"4818","DOI":"10.1118\/1.2795842","volume":"34","author":"IJ Chetty","year":"2007","unstructured":"Chetty, I. J. et al. Report of the AAPM task group no. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning. Med. Phys. 34, 4818\u20134853 (2007).","journal-title":"Med. Phys."},{"key":"36930_CR2","doi-asserted-by":"publisher","first-page":"2191","DOI":"10.1016\/0360-3016(84)90223-2","volume":"10","author":"CG Orton","year":"1984","unstructured":"Orton, C. G., Mondalek, P. M., Spicka, J. T., Herron, D. S. & Andres, L. I. Lung corrections in photon beam treatment planning: Are we ready?. Int. J. Radiat. Oncol. Biol. Phys. 10, 2191\u20132199 (1984).","journal-title":"Int. J. Radiat. Oncol. Biol. Phys."},{"key":"36930_CR3","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1016\/j.canrad.2015.04.007","volume":"19","author":"C Petit","year":"2015","unstructured":"Petit, C. et al. Overall treatment time assessment of radiotherapy delivered in a curative intent: A prospective study. Cancer Radiother. 19, 703\u2013709 (2015).","journal-title":"Cancer Radiother."},{"key":"36930_CR4","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1002\/acm2.12492","volume":"20","author":"Z Xu","year":"2019","unstructured":"Xu, Z. et al. Assessment of beam-matched linacs quality\/accuracy for interchanging SBRT or SRT patient using VMAT without replanning. J. Appl. Clin. Med. Phys. 20, 68\u201375 (2019).","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"36930_CR5","doi-asserted-by":"publisher","first-page":"2577","DOI":"10.31557\/APJCP.2021.22.8.2577","volume":"22","author":"N Sushma","year":"2021","unstructured":"Sushma, N., Kaginelli, S., Palanivel, S. & Ganesh, K. M. Verification of surface dose for flattening filter and flattening filter free beams in beam-matched medical linear accelerators. Asian Pac. J. Cancer Prev. 22, 2577\u20132585 (2021).","journal-title":"Asian Pac. J. Cancer Prev."},{"key":"36930_CR6","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1002\/acm2.12567","volume":"20","author":"J Rijken","year":"2019","unstructured":"Rijken, J., Schachenmayr, H., Crowe, S., Kairn, T. & Trapp, J. Distributive quality assurance and delivery of stereotactic ablative radiotherapy treatments amongst beam matched linear accelerators: A feasibility study. J. Appl. Clin. Med. Phys. 20, 99\u2013105 (2019).","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"36930_CR7","doi-asserted-by":"publisher","first-page":"20130238","DOI":"10.1259\/bjr.20130238","volume":"86","author":"B Sarkar","year":"2013","unstructured":"Sarkar, B. et al. A Mathematical approach to beam matching. Br. J. Radiol. 86, 20130238 (2013).","journal-title":"Br. J. Radiol."},{"key":"36930_CR8","doi-asserted-by":"publisher","first-page":"4077","DOI":"10.1120\/jacmp.v14i1.4077","volume":"14","author":"GP Beyer","year":"2013","unstructured":"Beyer, G. P. Commissioning measurements for photon beam data on three TrueBeam linear accelerators, and comparison with Trilogy and Clinac 2100 linear accelerators. J. Appl. Clin. Med. Phys. 14, 4077 (2013).","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"36930_CR9","doi-asserted-by":"publisher","first-page":"176","DOI":"10.4103\/0971-6203.83497","volume":"36","author":"JR Bhangle","year":"2011","unstructured":"Bhangle, J. R., Narayanan, V. K., Kumar, N. K. & Vaitheeswaran, R. Dosimetric analysis of beam-matching procedure of two similar linear accelerators. J. Med. Phys. 36, 176\u2013180 (2011).","journal-title":"J. Med. Phys."},{"key":"36930_CR10","doi-asserted-by":"publisher","first-page":"181","DOI":"10.17146\/aij.2021.1041","volume":"47","author":"OA Firmansyah","year":"2021","unstructured":"Firmansyah, O. A. et al. Implementation of beam matching concept for the new installed Elekta precise treatment system medical LINACs in Indonesia. Atom Indonesia 47, 181\u2013189 (2021).","journal-title":"Atom Indonesia"},{"key":"36930_CR11","doi-asserted-by":"publisher","first-page":"4078","DOI":"10.1118\/1.3438081","volume":"37","author":"SH Benedict","year":"2010","unstructured":"Benedict, S. H. et al. Stereotactic body radiation therapy: The report of AAPM task group 101. Med. Phys. 37, 4078\u20134101 (2010).","journal-title":"Med. Phys."},{"key":"36930_CR12","doi-asserted-by":"publisher","first-page":"e53","DOI":"10.1002\/mp.12810","volume":"45","author":"M Miften","year":"2018","unstructured":"Miften, M. et al. Tolerance limits and methodologies for IMRT measurement-based verification QA: Recommendations of AAPM task group no. 218. Med. Phys. 45, e53\u2013e83 (2018).","journal-title":"Med. Phys."},{"key":"36930_CR13","doi-asserted-by":"publisher","first-page":"015014","DOI":"10.1088\/2057-1976\/aa586d","volume":"3","author":"W Davis","year":"2017","unstructured":"Davis, W., Crewson, C., Alexander, A., Kundapur, V. & Cranmer-Sargison, G. Dosimetric characterization of an accessory mounted mini-beam collimator across clinically beam matched medical linear accelerators. Biomed. Phys. Eng. Express 3, 015014 (2017).","journal-title":"Biomed. Phys. Eng. Express"},{"key":"36930_CR14","doi-asserted-by":"publisher","first-page":"7599","DOI":"10.1088\/0031-9155\/57\/22\/7599","volume":"57","author":"JE Lye","year":"2012","unstructured":"Lye, J. E., Butler, D. J., Ramanathan, G. & Franich, R. D. Spectral differences in 6\u00a0mv beams with matched PDDs and the effect on chamber response. Phys. Med. Biol. 57, 7599\u20137614 (2012).","journal-title":"Phys. Med. Biol."},{"key":"36930_CR15","doi-asserted-by":"crossref","first-page":"211","DOI":"10.4103\/jmp.JMP_12_21","volume":"46","author":"JA Rojas-Lopez","year":"2021","unstructured":"Rojas-Lopez, J. A. & Venencia, D. Importance of beam-matching between TrueBeam STx and Novalis Tx in pre-treatment quality assurance using portal dosimetry. J. Med. Phys. 46, 211\u2013220 (2021).","journal-title":"J. Med. Phys."},{"key":"36930_CR16","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1002\/acm2.13160","volume":"22","author":"L Munoz","year":"2021","unstructured":"Munoz, L. et al. Consistency of small-field dosimetry, on and off axis, in beam-matched linacs used for stereotactic radiosurgery. J. Appl. Clin. Med. Phys. 22, 185\u2013193 (2021).","journal-title":"J. Appl. Clin. Med. Phys."},{"key":"36930_CR17","first-page":"3439","volume":"18","author":"S Ashokkumar","year":"2017","unstructured":"Ashokkumar, S., Ganesh, K. M., Ramalingam, K., Karthikeyan, K. & Jagadheeskumar, N. Dosimetric validation of volumetric modulated arc therapy with three 6MV beam-matched linear accelerators. Asian Pac. J. Cancer Prev. 18, 3439\u20133444 (2017).","journal-title":"Asian Pac. J. Cancer Prev."},{"key":"36930_CR18","doi-asserted-by":"publisher","first-page":"554","DOI":"10.1016\/j.radonc.2010.06.013","volume":"97","author":"M Oliver","year":"2010","unstructured":"Oliver, M. et al. Clinical significance of multi-leaf collimator positional errors for volumetric modulated arc therapy. Radiother. Oncol. 97, 554\u2013560 (2010).","journal-title":"Radiother. Oncol."},{"key":"36930_CR19","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1007\/s13246-019-00821-x","volume":"43","author":"JM Chojnowski","year":"2020","unstructured":"Chojnowski, J. M., Taylor, L. M., Sykes, J. R. & Thwaites, D. I. Assessing the dependency of the uncertainties in the Elekta agility MLC calibration procedure on the focal spot position. Phys. Eng. Sci. Med. 43, 93\u201396 (2020).","journal-title":"Phys. Eng. Sci. Med."},{"key":"36930_CR20","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1120\/jacmp.v17i6.6343","volume":"17","author":"LA Young","year":"2016","unstructured":"Young, L. A., Yang, F., Cao, N. & Meyer, J. Rounded leaf end modeling in Pinnacle VMAT treatment planning for fixed jaw linacs. J. Appl. Clin. Med. Phys. 17, 149\u2013162 (2016).","journal-title":"J. Appl. Clin. Med. Phys."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-36930-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-36930-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-36930-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,22]],"date-time":"2024-10-22T19:49:13Z","timestamp":1729626553000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-36930-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,6,22]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["36930"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-36930-7","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,6,22]]},"assertion":[{"value":"25 October 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 June 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 June 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10131"}}