{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T20:20:17Z","timestamp":1778876417860,"version":"3.51.4"},"reference-count":17,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T00:00:00Z","timestamp":1695686400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T00:00:00Z","timestamp":1695686400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Percutaneous drains have provided a minimally invasive way to treat a wide range of disorders from abscess drainage to enteral feeding solutions to treating hydronephrosis. These drains suffer from a high rate of dislodgement of up to 30% resulting in emergency room visits, repeat hospitalizations, and catheter repositioning\/replacement procedures, which incur significant morbidity and mortality. Using ex vivo and in vivo models, a force body diagram was utilized to determine the forces experienced by a drainage catheter during dislodgement events, and the\u00a0individual components which contribute to drainage catheter securement were empirically collected. Prototypes of a skin level catheter securement and valved quick release system were then developed. The system was inspired by capstans used in boating for increasing friction of a line around a central spool and quick release mechanisms used in electronics such as the Apple MagSafe computer charger. The device was tested in a porcine suprapubic model, which demonstrated the effectiveness of the device to prevent drain dislodgement. The prototype demonstrated that the miniaturized versions of technologies used in boating and electronics industries were able to meet the needs of preventing dislodgement of patient drainage catheters.\n<\/jats:p>","DOI":"10.1038\/s41598-023-37850-2","type":"journal-article","created":{"date-parts":[[2023,9,26]],"date-time":"2023-09-26T16:02:04Z","timestamp":1695744124000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Preventing inadvertent drain removal using a novel catheter securement device"],"prefix":"10.1038","volume":"13","author":[{"given":"Mario","family":"Russo","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"John","family":"Di Capua","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"April","family":"Anlage","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hersh","family":"Bendre","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jon","family":"Kusner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Graham","family":"Lieberman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sean","family":"Jang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zubin","family":"Irani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronald S.","family":"Arellano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Patrick D.","family":"Sutphin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sara","family":"Smolinski-Zhao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dania","family":"Daye","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sanjeeva P.","family":"Kalva","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marc D.","family":"Succi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Avik","family":"Som","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ashraf","family":"Thabet","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,9,26]]},"reference":[{"key":"37850_CR1","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.java.2018.07.002","volume":"23","author":"N Moureau","year":"2018","unstructured":"Moureau, N. Impact and safety associated with accidental dislodgement of vascular access devices: A survey of professions, settings, and devices. J. Assoc. Vasc. Access 23, 203\u2013215 (2018).","journal-title":"J. Assoc. Vasc. Access"},{"key":"37850_CR2","first-page":"9","volume":"14","author":"M Feil","year":"2017","unstructured":"Feil, M. Dislodged gastrostomy tubes: Preventing a potentially. Fatal Comp. 14, 9 (2017).","journal-title":"Fatal Comp."},{"key":"37850_CR3","doi-asserted-by":"publisher","first-page":"R229","DOI":"10.1186\/cc2874","volume":"8","author":"L Lorente","year":"2004","unstructured":"Lorente, L., Huidobro, M. S., Mart\u00edn, M. M., Jim\u00e9nez, A. & Mora, M. L. Accidental catheter removal in critically ill patients: A prospective and observational study. Crit. Care 8, R229 (2004).","journal-title":"Crit. Care"},{"key":"37850_CR4","doi-asserted-by":"publisher","first-page":"067","DOI":"10.1055\/s-0035-1549371","volume":"32","author":"S Huang","year":"2015","unstructured":"Huang, S., Engstrom, B., Lungren, M. & Kim, C. Management of dysfunctional catheters and tubes inserted by interventional radiology. Semin. Interv. Radiol. 32, 067\u2013077 (2015).","journal-title":"Semin. Interv. Radiol."},{"key":"37850_CR5","doi-asserted-by":"publisher","first-page":"861","DOI":"10.1016\/j.jvir.2010.02.022","volume":"21","author":"FB Collares","year":"2010","unstructured":"Collares, F. B., Faintuch, S., Kim, S. K. & Rabkin, D. J. Reinsertion of accidentally dislodged catheters through the original track: What is the likelihood of success?. J. Vasc. Interv. Radiol. 21, 861\u2013864 (2010).","journal-title":"J. Vasc. Interv. Radiol."},{"key":"37850_CR6","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1159\/000489230","volume":"96","author":"R Asciak","year":"2018","unstructured":"Asciak, R. et al. Chest drain fall-out rate according to suturing practices: A retrospective direct comparison. Respiration 96, 48\u201351 (2018).","journal-title":"Respiration"},{"key":"37850_CR7","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1177\/1553350615587408","volume":"23","author":"LH Rosenberger","year":"2016","unstructured":"Rosenberger, L. H. et al. reducing accidental dislodgement of the percutaneous endoscopic gastrostomy: a prospective trial of the \u201csafetybreak\u201d device. Surg. Innov. 23, 62\u201369 (2016).","journal-title":"Surg. Innov."},{"key":"37850_CR8","doi-asserted-by":"publisher","first-page":"779","DOI":"10.1007\/s40258-018-0427-1","volume":"16","author":"T Macmillan","year":"2018","unstructured":"Macmillan, T. et al. SecurAcath for securing peripherally inserted central catheters: A nice medical technology guidance. Appl. Health Econ. Health Policy. 16, 779\u2013791 (2018).","journal-title":"Appl. Health Econ. Health Policy."},{"key":"37850_CR9","doi-asserted-by":"publisher","first-page":"1329","DOI":"10.1016\/j.jacr.2020.04.020","volume":"17","author":"MD Succi","year":"2020","unstructured":"Succi, M. D. et al. Initial experience integrating a hands-on innovation curriculum into a radiology residency program and department. J. Am. Coll. Radiol. 17, 1329\u20131333 (2020).","journal-title":"J. Am. Coll. Radiol."},{"key":"37850_CR10","doi-asserted-by":"publisher","first-page":"892","DOI":"10.1016\/j.jacr.2018.02.017","volume":"15","author":"MD Succi","year":"2018","unstructured":"Succi, M. D., Uppot, R. N., Gee, M. S., McLoud, T. C. & Brink, J. A. Medically engineered solutions in health care: A technology incubator and design-thinking curriculum for radiology trainees. J. Am. Coll. Radiol. 15, 892\u2013896 (2018).","journal-title":"J. Am. Coll. Radiol."},{"key":"37850_CR11","doi-asserted-by":"publisher","first-page":"E290","DOI":"10.1148\/radiol.2021204518","volume":"300","author":"A Som","year":"2021","unstructured":"Som, A., Lang, M., Di Capua, J., Chonde, D. B. & Cochran, R. L. Resident-led medical student radiology research interest group: An engine for recruitment, research, and mentoring\u2014radiology in training. Radiology 300, E290\u2013E292 (2021).","journal-title":"Radiology"},{"key":"37850_CR12","unstructured":"Gupta, S., Gulati, M., Shankar, K. U., Rungta, U. & Suri, S. Percutaneous nephrostomy with real-time sonographic guidance. 4."},{"key":"37850_CR13","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1007\/s11547-006-0051-2","volume":"111","author":"G Carrafiello","year":"2006","unstructured":"Carrafiello, G. et al. Complications of percutaneous nephrostomy in the treatment of malignant ureteral obstructions: Single\u2013centre review. Radiol. Med. (Torino) 111, 562\u2013571 (2006).","journal-title":"Radiol. Med. (Torino)"},{"key":"37850_CR14","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/j.iccn.2019.06.002","volume":"54","author":"A Galazzi","year":"2019","unstructured":"Galazzi, A. et al. Accidental removal of devices in intensive care unit: An eight-year observational study. Intensive Crit. Care Nurs. 54, 34\u201338 (2019).","journal-title":"Intensive Crit. Care Nurs."},{"key":"37850_CR15","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1136\/thoraxjnl-2013-204812","volume":"70","author":"CE Hooper","year":"2015","unstructured":"Hooper, C. E., Welham, S. A. & Maskell, N. A. Pleural procedures and patient safety: A national BTS audit of practice: Table 1. Thorax 70, 189\u2013191 (2015).","journal-title":"Thorax"},{"key":"37850_CR16","doi-asserted-by":"crossref","unstructured":"Hooper, C., Maskell, N., & on behalf of the BTS audit team. British thoracic society national pleural procedures audit 2010.Thorax 66, 636\u2013637 (2011).","DOI":"10.1136\/thoraxjnl-2011-200077"},{"key":"37850_CR17","doi-asserted-by":"publisher","first-page":"2641","DOI":"10.1001\/jama.2015.16840","volume":"314","author":"NM Rahman","year":"2015","unstructured":"Rahman, N. M. et al. Effect of opioids vs NSAIDs and larger vs smaller chest tube size on pain control and pleurodesis efficacy among patients with malignant pleural effusion: The TIME1 randomized clinical trial. JAMA 314, 2641 (2015).","journal-title":"JAMA"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-37850-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-37850-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-37850-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,21]],"date-time":"2023-11-21T05:50:20Z","timestamp":1700545820000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-37850-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,26]]},"references-count":17,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["37850"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-37850-2","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,26]]},"assertion":[{"value":"9 December 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 June 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 September 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Dr. Di Capua and Dr. Som are listed inventors on a patent pending application (#63306932) which describes the securement device evaluated by this manuscript. As the intellectual property was created as part of an employment role, the employing institution, Massachusetts General Hospital, holds full ownership and rights to the intellectual property, in accordance with local legislation. The authors disclose no other financial or non-financial competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"16130"}}