{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T14:21:22Z","timestamp":1785853282185,"version":"3.56.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,8,24]],"date-time":"2023-08-24T00:00:00Z","timestamp":1692835200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,8,24]],"date-time":"2023-08-24T00:00:00Z","timestamp":1692835200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"National Research Foundation of Korea, South Korea","award":["RS-2023-00210960"],"award-info":[{"award-number":["RS-2023-00210960"]}]},{"name":"National Research Foundation of Korea, South Korea","award":["NRF-2019M3A9E2066882"],"award-info":[{"award-number":["NRF-2019M3A9E2066882"]}]},{"name":"Korea University Grant, South Korea","award":["K2225581"],"award-info":[{"award-number":["K2225581"]}]},{"name":"Korea University Guro Hospital Grant, South Korea","award":["K2210221"],"award-info":[{"award-number":["K2210221"]}]},{"name":"Korea Medical Device Development Fund grant, South Korea","award":["RS-2020-KD000054"],"award-info":[{"award-number":["RS-2020-KD000054"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Intracoronary optical coherence tomography (OCT) requires injection of flushing media for image acquisition. Alternative flushing media needs to be investigated to reduce the risk of contrast-induced renal dysfunction. We investigated the feasibility and safety of pentastarch (hydroxyethyl starch) for clinical OCT imaging. We prospectively enrolled 43 patients with 70 coronary lesions (46-stented; 24-native). Total 81 OCT pullback pairs were obtained by manual injection of iodine contrast, followed by pentastarch. Each pullback was assessed frame-by-frame using an automated customized lumen contour\/stent strut segmentation algorithm. Paired images were compared for the clear image segments (CIS), blood-flushing capability, and quantitative morphometric measurements. Overall image quality, as assessed by the proportion of CIS, was comparable between the contrast- and pentastarch-flushed images (97.1% vs. 96.5%; p\u2009=\u20090.160). The pixel-based blood-flushing capability was similar between the groups (0.951 [0.947\u20130.953] vs. 0.950 [0.948\u20130.952], p\u2009=\u20090.125). Quantitative two- and three-dimensional morphometric measurements of the paired images correlated well (p\u2009&lt;\u20090.001) with excellent inter-measurement variability. All patients safely underwent OCT imaging using pentastarch without resulting in clinically relevant complications or renal deterioration. Non-contrast OCT imaging using pentastarch is clinically safe and technically feasible with excellent image quality and could be a promising alternative strategy for patients at high risk of renal impairment.<\/jats:p>","DOI":"10.1038\/s41598-023-40363-7","type":"journal-article","created":{"date-parts":[[2023,8,24]],"date-time":"2023-08-24T10:03:10Z","timestamp":1692871390000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Feasibility and safety of non-contrast optical coherence tomography imaging using hydroxyethyl starch in coronary arteries"],"prefix":"10.1038","volume":"13","author":[{"given":"Dong Oh","family":"Kang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyeong Soo","family":"Nam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sunwon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hongki","family":"Yoo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin Won","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,8,24]]},"reference":[{"key":"40363_CR1","doi-asserted-by":"publisher","first-page":"2566","DOI":"10.1093\/eurheartj\/ehz332","volume":"40","author":"TW Johnson","year":"2019","unstructured":"Johnson, T. W. et al. Clinical use of intracoronary imaging. Part 2: Acute coronary syndromes, ambiguous coronary angiography findings, and guiding interventional decision-making: An expert consensus document of the European Association of Percutaneous Cardiovascular Interventions. Eur. Heart J. 40, 2566\u20132584 (2019).","journal-title":"Eur. Heart J."},{"key":"40363_CR2","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.1016\/j.jacc.2011.09.079","volume":"59","author":"GJ Tearney","year":"2012","unstructured":"Tearney, G. J. et al. Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: A report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation. J. Am. Coll. Cardiol. 59, 1058\u20131072 (2012).","journal-title":"J. Am. Coll. Cardiol."},{"key":"40363_CR3","doi-asserted-by":"publisher","first-page":"1551","DOI":"10.1161\/01.CIR.0000159354.43778.69","volume":"111","author":"IK Jang","year":"2005","unstructured":"Jang, I. K. et al. In vivo characterization of coronary atherosclerotic plaque by use of optical coherence tomography. Circulation 111, 1551\u20131555 (2005).","journal-title":"Circulation"},{"key":"40363_CR4","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.1016\/j.jacc.2016.05.099","volume":"68","author":"PA McCullough","year":"2016","unstructured":"McCullough, P. A. et al. Contrast-induced acute kidney injury. J. Am. Coll. Cardiol. 68, 1465\u20131473 (2016).","journal-title":"J. Am. Coll. Cardiol."},{"key":"40363_CR5","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1148\/radiol.2019192094","volume":"294","author":"MS Davenport","year":"2020","unstructured":"Davenport, M. S. et al. Use of Intravenous iodinated contrast media in patients with kidney disease: Consensus statements from the American College of Radiology and the National Kidney Foundation. Radiology 294, 660\u2013668 (2020).","journal-title":"Radiology"},{"key":"40363_CR6","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1016\/j.jacc.2011.05.023","volume":"58","author":"HS Gurm","year":"2011","unstructured":"Gurm, H. S. et al. Renal function-based contrast dosing to define safe limits of radiographic contrast media in patients undergoing percutaneous coronary interventions. J. Am. Coll. Cardiol. 58, 907\u2013914 (2011).","journal-title":"J. Am. Coll. Cardiol."},{"key":"40363_CR7","first-page":"1393","volume":"44","author":"R Mehran","year":"2004","unstructured":"Mehran, R. et al. A simple risk score for prediction of contrast-induced nephropathy after percutaneous coronary intervention: Development and initial validation. J. Am. Coll. Cardiol. 44, 1393\u20131399 (2004).","journal-title":"J. Am. Coll. Cardiol."},{"key":"40363_CR8","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1007\/s10554-015-0668-0","volume":"31","author":"MJ Suter","year":"2015","unstructured":"Suter, M. J. et al. Optimizing flushing parameters in intracoronary optical coherence tomography: An in vivo swine study. Int. J. Cardiovasc. Imaging 31, 1097\u20131106 (2015).","journal-title":"Int. J. Cardiovasc. Imaging"},{"key":"40363_CR9","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.bpa.2008.11.001","volume":"23","author":"C Ertmer","year":"2009","unstructured":"Ertmer, C., Rehberg, S., Van Aken, H. & Westphal, M. Relevance of non-albumin colloids in intensive care medicine. Best Pract. Res. Clin. Anaesthesiol. 23, 193\u2013212 (2009).","journal-title":"Best Pract. Res. Clin. Anaesthesiol."},{"key":"40363_CR10","doi-asserted-by":"publisher","first-page":"R185","DOI":"10.1186\/cc9293","volume":"14","author":"S Finfer","year":"2010","unstructured":"Finfer, S. et al. Resuscitation fluid use in critically ill adults: An international cross-sectional study in 391 intensive care units. Crit. Care 14, R185 (2010).","journal-title":"Crit. Care"},{"key":"40363_CR11","doi-asserted-by":"publisher","first-page":"1243","DOI":"10.1056\/NEJMra1208627","volume":"369","author":"JA Myburgh","year":"2013","unstructured":"Myburgh, J. A. & Mythen, M. G. Resuscitation fluids. N. Engl. J. Med. 369, 1243\u20131251 (2013).","journal-title":"N. Engl. J. Med."},{"key":"40363_CR12","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1046\/j.1537-2995.1988.28388219155.x","volume":"28","author":"RG Strauss","year":"1988","unstructured":"Strauss, R. G., Stansfield, C., Henriksen, R. A. & Villhauer, P. J. Pentastarch may cause fewer effects on coagulation than hetastarch. Transfusion 28, 257\u2013260 (1988).","journal-title":"Transfusion"},{"key":"40363_CR13","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1007\/s001340050833","volume":"25","author":"J Treib","year":"1999","unstructured":"Treib, J., Baron, J. F., Grauer, M. T. & Strauss, R. G. An international view of hydroxyethyl starches. Intensive Care Med. 25, 258\u2013268 (1999).","journal-title":"Intensive Care Med."},{"key":"40363_CR14","doi-asserted-by":"publisher","first-page":"288","DOI":"10.1007\/s12630-011-9648-6","volume":"59","author":"AM Walker","year":"2012","unstructured":"Walker, A. M., Lee, K., Dobson, G. M. & Johnston, C. R. The viscous behaviour of HES 130\/0.4 (Voluven\u00ae) and HES 260\/0.45 (Pentaspan\u00ae). Can. J. Anaesth. 59, 288\u2013294 (2012).","journal-title":"Can. J. Anaesth."},{"key":"40363_CR15","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1253\/circj.CJ-11-1122","volume":"76","author":"Y Ozaki","year":"2012","unstructured":"Ozaki, Y. et al. Comparison of contrast media and low-molecular-weight dextran for frequency-domain optical coherence tomography. Circ. J. 76, 922\u2013927 (2012).","journal-title":"Circ. J."},{"key":"40363_CR16","doi-asserted-by":"publisher","first-page":"727","DOI":"10.1002\/ccd.25092","volume":"84","author":"K Frick","year":"2014","unstructured":"Frick, K. et al. Low molecular weight dextran provides similar optical coherence tomography coronary imaging compared to radiographic contrast media. Catheter. Cardiovasc. Interv. 84, 727\u2013731 (2014).","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"40363_CR17","doi-asserted-by":"publisher","first-page":"2060","DOI":"10.1016\/j.jcmg.2020.04.018","volume":"13","author":"AK Gore","year":"2020","unstructured":"Gore, A. K. et al. Prospective comparison between saline and radiocontrast for intracoronary imaging with optical coherence tomography. JACC Cardiovasc. Imaging 13, 2060\u20132062 (2020).","journal-title":"JACC Cardiovasc. Imaging"},{"key":"40363_CR18","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1016\/j.ihj.2020.03.013","volume":"72","author":"NK Mahesh","year":"2020","unstructured":"Mahesh, N. K. et al. Study of saline optical coherence tomography-guided percutaneous coronary intervention (SOCT-PCI Study). Indian Heart J. 72, 239\u2013243 (2020).","journal-title":"Indian Heart J."},{"key":"40363_CR19","doi-asserted-by":"publisher","DOI":"10.3389\/fcvm.2022.844114","volume":"9","author":"T Chen","year":"2022","unstructured":"Chen, T. et al. Feasibility and safety of very-low contrast combined ringer\u2019s solution in optical coherence tomography imaging. Front. Cardiovasc. Med. 9, 844114 (2022).","journal-title":"Front. Cardiovasc. Med."},{"key":"40363_CR20","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1016\/j.carrev.2021.01.010","volume":"34","author":"A Gupta","year":"2022","unstructured":"Gupta, A. et al. Saline as an alternative to radio-contrast for optical coherence tomography-guided percutaneous coronary intervention: A prospective comparison. Cardiovasc. Revasc. Med. 34, 86\u201391 (2022).","journal-title":"Cardiovasc. Revasc. Med."},{"key":"40363_CR21","volume":"11","author":"Z Varga","year":"2019","unstructured":"Varga, Z., Rajpurohit, N., Li, S., Stys, T. & Stys, A. Frequency domain-optical coherence tomography of coronary arteries using a diluted iodinated contrast-saline mix with 5-Fr guide catheters. Cureus 11, e4892 (2019).","journal-title":"Cureus"},{"key":"40363_CR22","doi-asserted-by":"publisher","first-page":"S30","DOI":"10.1007\/BF03022250","volume":"53","author":"P Van der Linden","year":"2006","unstructured":"Van der Linden, P. & Ickx, B. E. The effects of colloid solutions on hemostasis. Can. J. Anaesth. 53, S30-39 (2006).","journal-title":"Can. J. Anaesth."},{"key":"40363_CR23","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1016\/S0750-7658(94)80038-3","volume":"13","author":"MC Laxenaire","year":"1994","unstructured":"Laxenaire, M. C., Charpentier, C. & Feldman, L. Anaphylactoid reactions to colloid plasma substitutes: Incidence, risk factors, mechanisms. A French multicenter prospective study. Ann. Fr. Anesth. Reanim. 13, 301\u2013310 (1994).","journal-title":"Ann. Fr. Anesth. Reanim."},{"key":"40363_CR24","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1177\/0284185115595059","volume":"57","author":"JJ Zhang","year":"2016","unstructured":"Zhang, J. J., Hogstrom, B., Malinak, J. & Ikei, N. Effects of viscosity on power and hand injection of iso-osmolar iodinated contrast media through thin catheters. Acta Radiol. 57, 557\u2013564 (2016).","journal-title":"Acta Radiol."},{"key":"40363_CR25","doi-asserted-by":"publisher","first-page":"1901","DOI":"10.1056\/NEJMoa1209759","volume":"367","author":"JA Myburgh","year":"2012","unstructured":"Myburgh, J. A. et al. Hydroxyethyl starch or saline for fluid resuscitation in intensive care. N. Engl. J. Med. 367, 1901\u20131911 (2012).","journal-title":"N. Engl. J. Med."},{"key":"40363_CR26","doi-asserted-by":"publisher","first-page":"678","DOI":"10.1001\/jama.2013.430","volume":"309","author":"R Zarychanski","year":"2013","unstructured":"Zarychanski, R. et al. Association of hydroxyethyl starch administration with mortality and acute kidney injury in critically ill patients requiring volume resuscitation: A systematic review and meta-analysis. JAMA 309, 678\u2013688 (2013).","journal-title":"JAMA"},{"key":"40363_CR27","doi-asserted-by":"publisher","first-page":"e1063","DOI":"10.1097\/CCM.0000000000005337","volume":"49","author":"L Evans","year":"2021","unstructured":"Evans, L. et al. Surviving sepsis campaign: International guidelines for management of sepsis and septic shock 2021. Crit. Care Med. 49, e1063\u2013e1143 (2021).","journal-title":"Crit. Care Med."},{"key":"40363_CR28","doi-asserted-by":"crossref","unstructured":"Hamdan, R., Ghostine, S., Amabile, N. & Caussin, C. Optimisation of new generation endo-coronary fourier domain optical coherence tomography. Eur. J. Cardiovasc. Med. 11 (2013).","DOI":"10.5083\/ejcm.20424884.94"},{"key":"40363_CR29","doi-asserted-by":"publisher","first-page":"1304","DOI":"10.1016\/j.jcmg.2015.11.020","volume":"9","author":"GJ Ughi","year":"2016","unstructured":"Ughi, G. J. et al. Clinical characterization of coronary atherosclerosis with dual-modality OCT and near-infrared autofluorescence imaging. JACC Cardiovasc. Imaging 9, 1304\u20131314 (2016).","journal-title":"JACC Cardiovasc. Imaging"},{"key":"40363_CR30","doi-asserted-by":"publisher","first-page":"948","DOI":"10.1016\/j.jacbts.2021.10.005","volume":"6","author":"S Kim","year":"2021","unstructured":"Kim, S. et al. Comprehensive assessment of high-risk plaques by dual-modal imaging catheter in coronary artery. JACC Basic Transl. Sci. 6, 948\u2013960 (2021).","journal-title":"JACC Basic Transl. Sci."},{"key":"40363_CR31","doi-asserted-by":"publisher","first-page":"14561","DOI":"10.1038\/s41598-018-32951-9","volume":"8","author":"MW Lee","year":"2018","unstructured":"Lee, M. W. et al. Comprehensive intravascular imaging of atherosclerotic plaque in vivo using optical coherence tomography and fluorescence lifetime imaging. Sci. Rep. 8, 14561 (2018).","journal-title":"Sci. Rep."},{"key":"40363_CR32","doi-asserted-by":"publisher","first-page":"8960","DOI":"10.1038\/s41598-017-08056-0","volume":"7","author":"J Bec","year":"2017","unstructured":"Bec, J. et al. In vivo label-free structural and biochemical imaging of coronary arteries using an integrated ultrasound and multispectral fluorescence lifetime catheter system. Sci. Rep. 7, 8960 (2017).","journal-title":"Sci. Rep."},{"key":"40363_CR33","doi-asserted-by":"publisher","first-page":"247","DOI":"10.7326\/0003-4819-145-4-200608150-00004","volume":"145","author":"AS Levey","year":"2006","unstructured":"Levey, A. S. et al. Using standardized serum creatinine values in the modification of diet in renal disease study equation for estimating glomerular filtration rate. Ann. Intern. Med. 145, 247\u2013254 (2006).","journal-title":"Ann. Intern. Med."},{"key":"40363_CR34","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1093\/eurheartj\/ehy394","volume":"40","author":"FJ Neumann","year":"2019","unstructured":"Neumann, F. J. et al. 2018 ESC\/EACTS Guidelines on myocardial revascularization. Eur. Heart J. 40, 87\u2013165 (2019).","journal-title":"Eur. Heart J."},{"key":"40363_CR35","doi-asserted-by":"crossref","first-page":"e4","DOI":"10.1161\/CIRCULATIONAHA.121.058519","volume":"145","author":"JS Lawton","year":"2022","unstructured":"Lawton, J. S. et al. 2021 ACC\/AHA\/SCAI guideline for coronary artery revascularization: Executive summary: A report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation 145, e4\u2013e17 (2022).","journal-title":"Circulation"},{"key":"40363_CR36","doi-asserted-by":"publisher","first-page":"1662","DOI":"10.1118\/1.4943374","volume":"43","author":"HS Nam","year":"2016","unstructured":"Nam, H. S. et al. Automated detection of vessel lumen and stent struts in intravascular optical coherence tomography to evaluate stent apposition and neointimal coverage. Med. Phys. 43, 1662 (2016).","journal-title":"Med. Phys."},{"key":"40363_CR37","doi-asserted-by":"crossref","unstructured":"Dierckx, P. Curve and Surface Fitting with Splines, Monograph on Numerical Analysis (Oxford Science Publication (Oxford), 1993).","DOI":"10.1093\/oso\/9780198534419.001.0001"},{"key":"40363_CR38","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1002\/ccd.22273","volume":"75","author":"S Takarada","year":"2010","unstructured":"Takarada, S. et al. Advantage of next-generation frequency-domain optical coherence tomography compared with conventional time-domain system in the assessment of coronary lesion. Catheter. Cardiovasc. Interv. 75, 202\u2013206 (2010).","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"40363_CR39","doi-asserted-by":"crossref","unstructured":"Mehran, R. & Nikolsky, E. Contrast-induced nephropathy: Definition, epidemiology, and patients at risk. Kidney Int. Suppl. S11\u201315 (2006).","DOI":"10.1038\/sj.ki.5000368"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-40363-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-40363-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-40363-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,19]],"date-time":"2023-11-19T08:07:01Z","timestamp":1700381221000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-40363-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,8,24]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["40363"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-40363-7","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,8,24]]},"assertion":[{"value":"4 May 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 August 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"13818"}}