{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T21:04:12Z","timestamp":1793739852627,"version":"4.6.1"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,9,20]],"date-time":"2023-09-20T00:00:00Z","timestamp":1695168000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,9,20]],"date-time":"2023-09-20T00:00:00Z","timestamp":1695168000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This article scrutinizes blood circulation through an artery having magnetized hybrid nanoparticles (silver and gold) with multiple stenoses at the outer walls and erratic thrombus of different radii at the center. In the realm of biomedical innovation, magnetized hybrid nanoparticles emerge as a captivating frontier. These nanoparticles, amalgamating diverse materials, exhibit magnetic properties that engender novel prospects for targeted drug delivery, medical imaging enhancement, and therapeutic interventions. The study was carried out employing modern bio-fluid dynamics (BFD) software. In this iterative procedure, a second-order finite difference approach is used to solve the governing equations with 0.005 tolerance. The experiment is performed on a blood conduit with mild stenosis assumptions, and expressions of temperature, resistance impedance to flow, velocity, wall shear stress, and pressure gradient are generated by employing related boundary conditions. No one has ever attempted to acquire the remedial impact of an induced magnetic field and hybrid nanoparticles on the bloodstream in a tapering artery containing multiple stenoses on the outside walls and multi-thrombus at the center using 3-D bio-fluid simulation. Furthermore, the study's findings are unique, and these computational discoveries were not previously published by any researcher. The findings suggest that hybrid nanoparticles can be used as medication carriers to reduce the impact of thrombosis and stenosis-induced resistance to blood flow or coagulation-related factors.<\/jats:p>","DOI":"10.1038\/s41598-023-42795-7","type":"journal-article","created":{"date-parts":[[2023,9,20]],"date-time":"2023-09-20T06:02:01Z","timestamp":1695189721000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Clinical symbiosis of hybrid nanoparticles and induced magnetic field on heat and mass transfer in multiple stenosed artery with erratic thrombosis"],"prefix":"10.1038","volume":"13","author":[{"given":"Azad","family":"Hussain","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad Naveel Riaz","family":"Dar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Warda Khalid","family":"Cheema","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanshuo","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rimsha","family":"Kanwal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,9,20]]},"reference":[{"key":"42795_CR1","doi-asserted-by":"publisher","first-page":"101189","DOI":"10.1016\/j.rineng.2023.101189","volume":"18","author":"A Hussain","year":"2023","unstructured":"Hussain, A., Dar, M. N. R., Cheema, W. K., Tag-eldin, E. M. & Kanwal, R. Numerical simulation of unsteady generic Newtonian blood flow and heat transfer through discrepant shaped dilatable arterial stenosis. Results Eng. 18, 101189 (2023).","journal-title":"Results Eng."},{"key":"42795_CR2","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1115\/1.3604621","volume":"90","author":"DF Young","year":"1968","unstructured":"Young, D. F. Effect of time-dependent stenosis on flow through a tube. Trans. ASME J. Eng. Ind. 90, 248\u2013254 (1968).","journal-title":"Trans. ASME J. Eng. Ind."},{"key":"42795_CR3","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/0895-7177(94)90116-3","volume":"19","author":"S Chakravarty","year":"1994","unstructured":"Chakravarty, S. & Mandal, P. K. Mathematical modeling of blood flow through an overlapping arterial stenosis. Math. Comput. Model. 19, 59\u201370 (1994).","journal-title":"Math. Comput. Model."},{"key":"42795_CR4","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/0895-7177(96)00079-9","volume":"24","author":"S Chakravarty","year":"1996","unstructured":"Chakravarty, S. & Mandal, P. K. A nonlinear two-dimensional model of blood flow in overlapping arterial stenosis subject to body acceleration. Math. Comput. Model. 24, 43\u201358 (1996).","journal-title":"Math. Comput. Model."},{"key":"42795_CR5","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1063\/1.4934583","volume":"5","author":"S Nadeem","year":"2015","unstructured":"Nadeem, S. & Ijaz, S. Single wall carbon nanotube (SWCNT) examination on blood flow through a multiple stenosed artery with variable nanofluid viscosity. AIP Adv. 5, 10 (2015).","journal-title":"AIP Adv."},{"key":"42795_CR6","first-page":"161","volume":"60","author":"K Maruthi Prasad","year":"2008","unstructured":"Maruthi Prasad, K. & Radhakrishnamacharya, G. Flow of Herschel-Bulkley fluid through an inclined tube of non-uniform cross-section with multiple stenosis. Arch. Mech. 60, 161\u2013172 (2008).","journal-title":"Arch. Mech."},{"key":"42795_CR7","doi-asserted-by":"publisher","first-page":"807","DOI":"10.1007\/s40819-016-0133-3","volume":"3","author":"R Ponalagusamy","year":"2017","unstructured":"Ponalagusamy, R. Two-fluid model for blood flow through tapered arterial stenosis: Effect of non-zero couple stress boundary condition at the interface. Int. J. Appl. Comput. Math. 3, 807\u2013824 (2017).","journal-title":"Int. J. Appl. Comput. Math."},{"key":"42795_CR8","first-page":"7108","volume":"217","author":"S Nadeem","year":"2011","unstructured":"Nadeem, S., Akbar, N. S., Hayat, T. & Hendi, A. Power law fluid model for blood flow through a tapered artery with a stenosis. Appl. Math. Comput. 217, 7108\u20137116 (2011).","journal-title":"Appl. Math. Comput."},{"issue":"3","key":"42795_CR9","first-page":"831","volume":"122","author":"M Al-Saad","year":"2020","unstructured":"Al-Saad, M., Suarez, C., Obeidat, A., Bordas, S. & Kulasegaram, S. Application of smooth particle hydrodynamics method for modeling blood flow with thrombus formation. Comput. Model. Eng. Sci. 122(3), 831\u2013862 (2020).","journal-title":"Comput. Model. Eng. Sci."},{"issue":"3","key":"42795_CR10","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/0021-9290(81)90020-8","volume":"14","author":"J Doffin","year":"1981","unstructured":"Doffin, J. & Chagneau, F. Oscillating flow between a clot model and stenosis. J. Biomech. 14(3), 143\u2013148 (1981).","journal-title":"J. Biomech."},{"key":"42795_CR11","first-page":"439","volume-title":"Fluid Dynamics at Interfaces","author":"Y Haik","year":"1999","unstructured":"Haik, Y., Pai, V. & Chen, C. J. Biomagnetic fluid dynamics. In Fluid Dynamics at Interfaces (eds Shyy, W. & Narayanan, R.) 439\u2013452 (Cambridge University Press, 1999)."},{"key":"42795_CR12","doi-asserted-by":"publisher","first-page":"85","DOI":"10.22457\/jmi.v18a8164","volume":"18","author":"A Mwapinga","year":"2020","unstructured":"Mwapinga, A. et al. MHD arterial blood flow and mass transfer under the presence of stenosis, body acceleration, and chemical reaction: A case of magnetic therapy. J. Math. Inform. 18, 85\u2013103 (2020).","journal-title":"J. Math. Inform."},{"key":"42795_CR13","unstructured":"W. Arnold, R. J. Klein, C. Alexiou, Locoregional cancer treatment with magnetic drug targeting, Cancer Research, 2000, 6641\u20136648."},{"key":"42795_CR14","first-page":"99","volume":"231","author":"SUS Choi","year":"1995","unstructured":"Choi, S. U. S. & Eastman, J. A. Enhancing thermal conductivity of fluids with nanofluids. ASME Fluids Eng. Div. 231, 99\u2013105 (1995).","journal-title":"ASME Fluids Eng. Div."},{"key":"42795_CR15","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1038\/nbt1006-1211","volume":"24","author":"V Wagner","year":"2006","unstructured":"Wagner, V., Dullaart, A., Bock, A. K. & Zweck, A. The emerging nanomedicine landscape. Nat. Biotechnol. 24, 10 (2006).","journal-title":"Nat. Biotechnol."},{"key":"42795_CR16","doi-asserted-by":"publisher","first-page":"615","DOI":"10.1016\/j.molliq.2016.01.059","volume":"216","author":"A Ahmed","year":"2016","unstructured":"Ahmed, A. & Nadeem, S. The study of (Cu, TiO2, Al2O3) nanoparticles as antimicrobials of blood flow through diseased arteries. J. Mol. Liq. 216, 615\u2013623 (2016).","journal-title":"J. Mol. Liq."},{"key":"42795_CR17","doi-asserted-by":"publisher","first-page":"105486","DOI":"10.1016\/j.icheatmasstransfer.2021.105486","volume":"127","author":"L Sarwar","year":"2021","unstructured":"Sarwar, L. & Hussain, A. Flow characteristics of Au-blood Nanofluid in the stenotic artery. Int. Commun. Heat Mass Transfer 127, 105486 (2021).","journal-title":"Int. Commun. Heat Mass Transfer"},{"key":"42795_CR18","first-page":"132","volume":"66","author":"Z Ahmed","year":"2016","unstructured":"Ahmed, Z., Moshan, H., Rahmat, E. & Muhammad, N. Shape effect of nanosize particles in unsteady mixed convection flow of nanofluid over a disk with entropy generation. Eng. Mech. 66, 132 (2016).","journal-title":"Eng. Mech."},{"key":"42795_CR19","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1007\/s13204-012-0165-x","volume":"4","author":"S Nadeem","year":"2014","unstructured":"Nadeem, S. & Maraj, E. N. The mathematical analysis for peristaltic flow of a nanofluid in a curved channel with compliant walls. Appl. Nanosci. 4, 85\u201392 (2014).","journal-title":"Appl. Nanosci."},{"issue":"2","key":"42795_CR20","doi-asserted-by":"publisher","first-page":"272","DOI":"10.4006\/0836-1398-29.2.272","volume":"29","author":"KS Mekheimer","year":"2016","unstructured":"Mekheimer, K. S., Elnaqeeb, T., El Kot, M. & Alghamdi, F. Simultaneous effect of magnetic field and metallic nanoparticles on a micropolar fluid through an overlapping stenotic artery: Blood flow model. Phys. Essays 29(2), 272\u2013283 (2016).","journal-title":"Phys. Essays"},{"issue":"1","key":"42795_CR21","doi-asserted-by":"publisher","first-page":"201","DOI":"10.12732\/ijpam.v107i1.16","volume":"107","author":"KS Mekheimer","year":"2016","unstructured":"Mekheimer, K. S., Mohamed, M. S. & Elnaqeeb, T. Metallic nanoparticles influence on blood flow through a stenotic artery. Int. J. Pure. Appl. Math. 107(1), 201 (2016).","journal-title":"Int. J. Pure. Appl. Math."},{"key":"42795_CR22","first-page":"316","volume":"2","author":"KB Abdessalem","year":"2015","unstructured":"Abdessalem, K. B. & Salah, R. B. Diagnosis of arterial thrombosis and stenosis in blood vessels using bioimpedance analysis. Int. Res. J. Eng. Technol. 2, 316\u2013321 (2015).","journal-title":"Int. Res. J. Eng. Technol."},{"key":"42795_CR23","doi-asserted-by":"publisher","first-page":"4130","DOI":"10.1016\/j.rinp.2017.10.032","volume":"7","author":"A Ahmed","year":"2017","unstructured":"Ahmed, A. & Nadeem, S. Effects of magnetohydrodynamics and hybrid nanoparticles on a micropolar fluid with 6 types of stenosis. Results Phys. 7, 4130\u20134139 (2017).","journal-title":"Results Phys."},{"key":"42795_CR24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/17455030.2022.2139016","volume":"20","author":"MNR Dar","year":"2022","unstructured":"Dar, M. N. R. & Hussain, A. Computational analysis of an incompressible blood flow in bifurcated arteries. Waves Random Complex Media 20, 1\u201313 (2022).","journal-title":"Waves Random Complex Media"},{"key":"42795_CR25","doi-asserted-by":"publisher","first-page":"106152","DOI":"10.1016\/j.rinp.2022.106152","volume":"44","author":"H Waqas","year":"2023","unstructured":"Waqas, H. et al. Numerical and computational simulation of blood flow on hybrid nanofluid with heat transfer through a stenotic artery: Silver and gold nanoparticles. Results Phys. 44, 106152 (2023).","journal-title":"Results Phys."},{"issue":"3","key":"42795_CR26","doi-asserted-by":"publisher","first-page":"1601","DOI":"10.3390\/app12031601","volume":"12","author":"A Hussain","year":"2022","unstructured":"Hussain, A. et al. Heat transfer analysis and effects of (silver and gold) nanoparticles on blood flow inside arterial stenosis. Appl. Sci. 12(3), 1601 (2022).","journal-title":"Appl. Sci."},{"key":"42795_CR27","doi-asserted-by":"crossref","unstructured":"Nasrin, R., Hossain, A., & Zahan, I. Blood flow analysis inside a stenotic artery using Power-Law fluid model. RDMS 2020, 13, 1\u201310.","DOI":"10.31031\/RDMS.2020.13.000803"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-42795-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-42795-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-42795-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,21]],"date-time":"2023-11-21T00:48:26Z","timestamp":1700527706000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-42795-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,20]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["42795"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-42795-7","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,20]]},"assertion":[{"value":"21 July 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 September 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 September 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"15588"}}