{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T16:09:22Z","timestamp":1790093362794,"version":"4.0.1"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T00:00:00Z","timestamp":1695772800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T00:00:00Z","timestamp":1695772800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"the National Research Foundation of Korea (NRF) grant funded by the Korea government","award":["NRF-2021R1G1A1094042"],"award-info":[{"award-number":["NRF-2021R1G1A1094042"]}]},{"DOI":"10.13039\/501100002631","name":"Gachon University","doi-asserted-by":"publisher","award":["GCU-202205980001"],"award-info":[{"award-number":["GCU-202205980001"]}],"id":[{"id":"10.13039\/501100002631","id-type":"DOI","asserted-by":"publisher"}]},{"name":"the Gachon Program","award":["GCU-202106290001"],"award-info":[{"award-number":["GCU-202106290001"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The extra-articular distal humerus plate (EADHP) has been widely used for surgical treatment of distal humerus shaft fracture (DHSF). However, the surgical approach, fixation methods, and implant positions of the EADHP remain controversial owing to iatrogenic radial nerve injury and complaints such as skin irritation related to the plate. Anterior plating with a modified (upside-down application) proximal humerus locking plate (PHILOS) has been proposed as an alternative, However, research on its biomechanical performance remain insufficient and were mostly based on retrospective studies. This study quantitatively compared and evaluated the biomechanical performance between posterior plating with the EADHP and anterior plating with a modified PHILOS using finite element analysis (FEA). The FEA simulation results that both the EADHP and PHILOS had adequate biomechanical performance and stability under axial, bending, and varus force load conditions. The PHILOS has a fixed stability comparable to that of the EADHP, and fixation was achieved using only four locking screws within a fixed range of 30\u00a0mm just above the olecranon fossa. The results show that the PHILOS could be an option for the fixation of a DHSF when considering the dissection range and complaints (e.g. skin irritation) associated with the EADHP.<\/jats:p>","DOI":"10.1038\/s41598-023-43183-x","type":"journal-article","created":{"date-parts":[[2023,9,27]],"date-time":"2023-09-27T10:03:10Z","timestamp":1695808990000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Biomechanical performance evaluation of a modified proximal humerus locking plate for distal humerus shaft fracture using finite element analysis"],"prefix":"10.1038","volume":"13","author":[{"given":"Jung-Soo","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kwang Gi","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong-Cheol","family":"Yoon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,9,27]]},"reference":[{"key":"43183_CR1","doi-asserted-by":"publisher","DOI":"10.1097\/00003086-200402000-00008","author":"DA Volgas","year":"2004","unstructured":"Volgas, D. A., Stannard, J. P. & Alonso, J. E. Nonunions of the humerus. Clin. Orthop. Relat. Res. https:\/\/doi.org\/10.1097\/00003086-200402000-00008 (2004).","journal-title":"Clin. Orthop. Relat. Res."},{"key":"43183_CR2","doi-asserted-by":"publisher","first-page":"S41","DOI":"10.1016\/j.otsr.2014.07.034","volume":"101","author":"L Pidhorz","year":"2015","unstructured":"Pidhorz, L. Acute and chronic humeral shaft fractures in adults. Orthop. Traumatol. Surg. Res. 101, S41-49. https:\/\/doi.org\/10.1016\/j.otsr.2014.07.034 (2015).","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"43183_CR3","doi-asserted-by":"publisher","first-page":"86","DOI":"10.4103\/0019-5413.197554","volume":"51","author":"D Jain","year":"2017","unstructured":"Jain, D. et al. Outcome of anatomic locking plate in extraarticular distal humeral shaft fractures. Indian J. Orthop. 51, 86\u201392. https:\/\/doi.org\/10.4103\/0019-5413.197554 (2017).","journal-title":"Indian J. Orthop."},{"key":"43183_CR4","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1007\/s00402-002-0403-x","volume":"122","author":"O Pehlivan","year":"2002","unstructured":"Pehlivan, O. Functional treatment of the distal third humeral shaft fractures. Arch. Orthop. Trauma Surg. 122, 390\u2013395. https:\/\/doi.org\/10.1007\/s00402-002-0403-x (2002).","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"43183_CR5","doi-asserted-by":"publisher","first-page":"2343","DOI":"10.2106\/JBJS.F.00334","volume":"88","author":"A Jawa","year":"2006","unstructured":"Jawa, A., McCarty, P., Doornberg, J., Harris, M. & Ring, D. Extra-articular distal-third diaphyseal fractures of the humerus. A comparison of functional bracing and plate fixation. J. Bone Jt. Surg. Am. 88, 2343\u20132347. https:\/\/doi.org\/10.2106\/JBJS.F.00334 (2006).","journal-title":"J. Bone Jt. Surg. Am."},{"key":"43183_CR6","doi-asserted-by":"publisher","first-page":"2119","DOI":"10.1007\/s00264-022-05435-9","volume":"46","author":"SJ Shin","year":"2022","unstructured":"Shin, S. J., Kwak, J. W. & Sohn, H. S. Comparison between anterior and posterior plating systems in extra-articular distal-third diaphyseal humeral fractures. Int. Orthop. 46, 2119\u20132126. https:\/\/doi.org\/10.1007\/s00264-022-05435-9 (2022).","journal-title":"Int. Orthop."},{"key":"43183_CR7","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1016\/j.hcl.2015.06.007","volume":"31","author":"MA Mighell","year":"2015","unstructured":"Mighell, M. A., Stephens, B., Stone, G. P. & Cottrell, B. J. Distal humerus fractures: Open reduction internal fixation. Hand Clin. 31, 591\u2013604. https:\/\/doi.org\/10.1016\/j.hcl.2015.06.007 (2015).","journal-title":"Hand Clin."},{"key":"43183_CR8","doi-asserted-by":"publisher","first-page":"2040","DOI":"10.1016\/j.injury.2014.08.036","volume":"45","author":"JA Scolaro","year":"2014","unstructured":"Scolaro, J. A., Hsu, J. E., Svach, D. J. & Mehta, S. Plate selection for fixation of extra-articular distal humerus fractures: A biomechanical comparison of three different implants. Injury 45, 2040\u20132044. https:\/\/doi.org\/10.1016\/j.injury.2014.08.036 (2014).","journal-title":"Injury"},{"key":"43183_CR9","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1016\/j.hcl.2007.11.004","volume":"23","author":"PA Cole","year":"2007","unstructured":"Cole, P. A. & Wijdicks, C. A. The operative treatment of diaphyseal humeral shaft fractures. Hand Clin. 23, 437\u2013448 (2007).","journal-title":"Hand Clin."},{"key":"43183_CR10","doi-asserted-by":"publisher","first-page":"1757","DOI":"10.1007\/s00264-017-3514-2","volume":"41","author":"W Zhao","year":"2017","unstructured":"Zhao, W. et al. Antero-lateral minimally invasive plate osteosynthesis (MIPO) with the radial nerve exploration for extra-articular distal-third diaphyseal fractures of the humerus. Int. Orthop. 41, 1757\u20131762. https:\/\/doi.org\/10.1007\/s00264-017-3514-2 (2017).","journal-title":"Int. Orthop."},{"key":"43183_CR11","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1016\/j.clinbiomech.2012.03.008","volume":"27","author":"RC Koonce","year":"2012","unstructured":"Koonce, R. C., Baldini, T. H. & Morgan, S. J. Are conventional reconstruction plates equivalent to precontoured locking plates for distal humerus fracture fixation? A biomechanics cadaver study. Clin. Biomech. (Bristol, Avon) 27, 697\u2013701. https:\/\/doi.org\/10.1016\/j.clinbiomech.2012.03.008 (2012).","journal-title":"Clin. Biomech. (Bristol, Avon)"},{"key":"43183_CR12","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/j.jos.2017.10.005","volume":"23","author":"HM Lee","year":"2018","unstructured":"Lee, H. M., Kim, Y. S., Kang, S., Lee, M. Y. & Kim, J. P. Modified anterolateral approach for internal fixation of Holstein-Lewis humeral shaft fractures. J. Orthop. Sci. 23, 137\u2013143. https:\/\/doi.org\/10.1016\/j.jos.2017.10.005 (2018).","journal-title":"J. Orthop. Sci."},{"key":"43183_CR13","doi-asserted-by":"publisher","first-page":"1121","DOI":"10.1016\/j.injury.2014.02.034","volume":"45","author":"P Yin","year":"2014","unstructured":"Yin, P. et al. Comparison of lateral and posterior surgical approach in management of extra-articular distal humeral shaft fractures. Injury 45, 1121\u20131125. https:\/\/doi.org\/10.1016\/j.injury.2014.02.034 (2014).","journal-title":"Injury"},{"issue":"Suppl 3","key":"43183_CR14","doi-asserted-by":"publisher","first-page":"S56","DOI":"10.1016\/S0020-1383(13)70200-6","volume":"44","author":"S Sabalic","year":"2013","unstructured":"Sabalic, S., Kodvanj, J. & Pavic, A. Comparative study of three models of extra-articular distal humerus fracture osteosynthesis using the finite element method on an osteoporotic computational model. Injury 44(Suppl 3), S56-61. https:\/\/doi.org\/10.1016\/S0020-1383(13)70200-6 (2013).","journal-title":"Injury"},{"key":"43183_CR15","doi-asserted-by":"publisher","first-page":"100420","DOI":"10.1016\/j.tcr.2021.100420","volume":"34","author":"B Thorat","year":"2021","unstructured":"Thorat, B., Singh, A., Vohra, R., Arshad, M. & Mavani, R. Modified application of distal medial tibial locking plate as an alternative for fixation of an extraarticular distal-third diaphyseal humerus fracture. Trauma Case Rep. 34, 100420 (2021).","journal-title":"Trauma Case Rep."},{"key":"43183_CR16","doi-asserted-by":"publisher","first-page":"306","DOI":"10.29252\/beat-060406","volume":"6","author":"N Ali","year":"2018","unstructured":"Ali, N. et al. Outcome of extra-articular distal humerus fractures fixed by single column extra-articular distal humerus locking compression plate using triceps sparing postero-lateral approach. Bull. Emerg. Trauma 6, 306\u2013312. https:\/\/doi.org\/10.29252\/beat-060406 (2018).","journal-title":"Bull. Emerg. Trauma"},{"key":"43183_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s11751-016-0270-6","volume":"12","author":"Y Kharbanda","year":"2017","unstructured":"Kharbanda, Y. et al. Retrospective analysis of extra-articular distal humerus shaft fractures treated with the use of pre-contoured lateral column metaphyseal LCP by triceps-sparing posterolateral approach. Strateg. Trauma Limb Reconstr. 12, 1\u20139. https:\/\/doi.org\/10.1007\/s11751-016-0270-6 (2017).","journal-title":"Strateg. Trauma Limb Reconstr."},{"key":"43183_CR18","doi-asserted-by":"publisher","first-page":"1877","DOI":"10.1002\/jor.24925","volume":"39","author":"JR Lim","year":"2021","unstructured":"Lim, J. R., Yoon, T. H., Choi, Y. R., Lee, H. M. & Chun, Y. M. Biomechanical evaluation of a modified proximal humeral locking plate application for distal extra-articular diaphyseal humeral fractures. J. Orthop. Res. 39, 1877\u20131883. https:\/\/doi.org\/10.1002\/jor.24925 (2021).","journal-title":"J. Orthop. Res."},{"key":"43183_CR19","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1007\/s00068-022-02064-0","volume":"49","author":"HS Jung","year":"2023","unstructured":"Jung, H. S., Won, Y. S., Choi, Y. S. & Lee, J. S. Risk factors for hardware-related complications after extra-articular distal humerus fracture fixation using an anatomical locking plate. Eur. J. Trauma Emerg. Surg. 49, 125\u2013131. https:\/\/doi.org\/10.1007\/s00068-022-02064-0 (2023).","journal-title":"Eur. J. Trauma Emerg. Surg."},{"key":"43183_CR20","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1007\/s00264-013-2213-x","volume":"38","author":"JT Capo","year":"2014","unstructured":"Capo, J. T., Debkowska, M. P., Liporace, F., Beutel, B. G. & Melamed, E. Outcomes of distal humerus diaphyseal injuries fixed with a single-column anatomic plate. Int. Orthop. 38, 1037\u20131043 (2014).","journal-title":"Int. Orthop."},{"key":"43183_CR21","doi-asserted-by":"publisher","first-page":"527","DOI":"10.1186\/s12891-019-2888-2","volume":"20","author":"S Lotzien","year":"2019","unstructured":"Lotzien, S. et al. Open reduction and internal fixation of humeral midshaft fractures: Anterior versus posterior plate fixation. BMC Musculoskelet. Disord. 20, 527. https:\/\/doi.org\/10.1186\/s12891-019-2888-2 (2019).","journal-title":"BMC Musculoskelet. Disord."},{"key":"43183_CR22","doi-asserted-by":"publisher","first-page":"1300","DOI":"10.1016\/j.injury.2019.05.030","volume":"50","author":"HS Sohn","year":"2019","unstructured":"Sohn, H. S. & Shin, S. J. Modified use of a proximal humeral internal locking system (PHILOS) plate in extra-articular distal-third diaphyseal humeral fractures. Injury 50, 1300\u20131305. https:\/\/doi.org\/10.1016\/j.injury.2019.05.030 (2019).","journal-title":"Injury"},{"key":"43183_CR23","doi-asserted-by":"publisher","first-page":"66","DOI":"10.5397\/cise.2021.00227","volume":"24","author":"JR Lim","year":"2021","unstructured":"Lim, J. R., Yoon, T. H., Lee, H. M. & Chun, Y. M. Anatomic fit of precontoured extra-articular distal humeral locking plates: A cadaveric study. Clin. Shoulder Elb. 24, 66\u201371. https:\/\/doi.org\/10.5397\/cise.2021.00227 (2021).","journal-title":"Clin. Shoulder Elb."},{"key":"43183_CR24","doi-asserted-by":"publisher","first-page":"141","DOI":"10.3109\/17453676708989628","volume":"38","author":"O Lindahl","year":"1967","unstructured":"Lindahl, O. & Lindgren, A. G. Cortical bone in man. II. Variation in tensile strength with age and sex. Acta Orthop. Scand. 38, 141\u2013147. https:\/\/doi.org\/10.3109\/17453676708989628 (1967).","journal-title":"Acta Orthop. Scand."},{"key":"43183_CR25","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1007\/s00276-006-0140-x","volume":"28","author":"P Clavert","year":"2006","unstructured":"Clavert, P. et al. Finite element analysis of the strain distribution in the humeral head tubercles during abduction: Comparison of young and osteoporotic bone. Surg. Radiol. Anat. 28, 581\u2013587. https:\/\/doi.org\/10.1007\/s00276-006-0140-x (2006).","journal-title":"Surg. Radiol. Anat."},{"key":"43183_CR26","doi-asserted-by":"publisher","first-page":"1268774","DOI":"10.1155\/2022\/1268774","volume":"2022","author":"JS Lee","year":"2022","unstructured":"Lee, J. S., Kim, J. H., Kim, K. G. & Yoon, Y. C. Effect of Calcar screw in locking compression plate system for osteoporotic proximal humerus fracture: A finite element analysis study. Biomed. Res. Int. 2022, 1268774. https:\/\/doi.org\/10.1155\/2022\/1268774 (2022).","journal-title":"Biomed. Res. Int."},{"key":"43183_CR27","doi-asserted-by":"publisher","first-page":"674","DOI":"10.1186\/s13018-021-02836-1","volume":"16","author":"L Kong","year":"2021","unstructured":"Kong, L., Wang, Y., Lu, Q., Han, Y. & Wang, F. Biomechanical properties of a novel fixation system for intra-articular distal humerus fractures: A finite element analysis. J. Orthop. Surg. Res. 16, 674. https:\/\/doi.org\/10.1186\/s13018-021-02836-1 (2021).","journal-title":"J. Orthop. Surg. Res."},{"key":"43183_CR28","doi-asserted-by":"publisher","first-page":"128","DOI":"10.5397\/cise.2015.18.3.128","volume":"18","author":"JH Park","year":"2015","unstructured":"Park, J. H. et al. PHILOS plate osteosynthesis in metaphyseal fractures of the distal humerus through an anterolateral approach. Clin. Shoulder Elb. 18, 128\u2013132 (2015).","journal-title":"Clin. Shoulder Elb."},{"key":"43183_CR29","doi-asserted-by":"publisher","first-page":"1938","DOI":"10.1016\/j.injury.2020.05.022","volume":"51","author":"H Bansal","year":"2020","unstructured":"Bansal, H., Mittal, S., Gupta, A. & Trikha, V. Analyzing the modified use of a proximal humeral internal locking system (PHILOS) plate in extra-articular distal-third diaphyseal humeral fractures with some concerns. Injury 51, 1938. https:\/\/doi.org\/10.1016\/j.injury.2020.05.022 (2020).","journal-title":"Injury"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-43183-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-43183-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-43183-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,20]],"date-time":"2023-11-20T05:19:42Z","timestamp":1700457582000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-43183-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,27]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["43183"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-43183-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,27]]},"assertion":[{"value":"1 June 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 September 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 September 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"16250"}}