{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,25]],"date-time":"2026-04-25T17:46:28Z","timestamp":1777139188280,"version":"3.51.4"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,11,4]],"date-time":"2023-11-04T00:00:00Z","timestamp":1699056000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,11,4]],"date-time":"2023-11-04T00:00:00Z","timestamp":1699056000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    To assess the effect of sodium fluorescein (NaF) strip on corneal parameters commonly used in Laser-assisted in-situ keratomileusis (LASIK). Eighty-six subjects (172 eyes) scheduled for LASIK were recruited between January and March 2022. The study and statistical analysis test were conducted in April 2022. Topographic measurements of corneal parameters, including central corneal thickness (CCT), anterior keratometric (K) readings (K1, flat keratometry; K2, steep keratometry), horizontal corneal diameter (white to white, WTW), and corneal asphericity (Q value), were obtained using a Scheimpflug device (Pentacam) before and 10\u00a0min after NaF strip treatmentThe Pentacam recorded a small significant increase in CCT (mean 538.88\u2009\u00b1\u200928.78\u00a0\u03bcm to 547.90\u2009\u00b1\u200929.94\u00a0\u03bcm;\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u2009.001), with no differences in K1 and K2 (mean 42.24\u2009\u00b1\u20091.35D to 42.24\u2009\u00b1\u20091.35D, and mean 43.34\u2009\u00b1\u20091.50D to 43.32\u2009\u00b1\u20091.51D;\n                    <jats:italic>P<\/jats:italic>\n                    \u2009&gt;\u2009.05, for all) as well as WTW(mean 11.58\u2009\u00b1\u20090.32\u00a0mm to 11.58\u2009\u00b1\u20090.32\u00a0mm,\n                    <jats:italic>P<\/jats:italic>\n                    \u2009&gt;\u2009.05) before and after NaF strip intervention. Furthermore, there was no significant difference was observed in Q value (mean \u2212\u00a00.30\u2009\u00b1\u20090.13 to \u2212\u00a00.30\u2009\u00b1\u20090.14,\n                    <jats:italic>P<\/jats:italic>\n                    \u2009&gt;\u2009.05). These results indicate that clinicians should avoid NaF strip application before obtaining precise topographic measurements of cornea parameters using the Pentacam.\n                  <\/jats:p>","DOI":"10.1038\/s41598-023-46502-4","type":"journal-article","created":{"date-parts":[[2023,11,4]],"date-time":"2023-11-04T11:01:39Z","timestamp":1699095699000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Effect of sodium fluorescein strip application on cornea parameters commonly used in laser-assisted in-situ keratomileusis"],"prefix":"10.1038","volume":"13","author":[{"given":"Dongmei","family":"Han","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenjuan","family":"Xie","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Muqu","family":"Yuan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jing","family":"Cui","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qifeng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qingsong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,11,4]]},"reference":[{"key":"46502_CR1","doi-asserted-by":"publisher","first-page":"2085","DOI":"10.1016\/S0140-6736(18)33209-4","volume":"393","author":"TI Kim","year":"2019","unstructured":"Kim, T. I., Ali\u00f3 Del Barrio, J. L., Wilkins, M., Cochener, B. & Ang, M. Refractive surgery. The Lancet 393, 2085\u20132098 (2019).","journal-title":"The Lancet"},{"key":"46502_CR2","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1016\/j.jcrs.2004.09.043","volume":"31","author":"J\u00d8 Hjortdal","year":"2005","unstructured":"Hjortdal, J. \u00d8., M\u00f8ller-Pedersen, T., Ivarsen, A. & Ehlers, N. Corneal power, thickness, and stiffness: results of a prospective randomized controlled trial of PRK and LASIK for myopia. J. Cataract. Refract. Surg. 31, 21\u201329 (2005).","journal-title":"J. Cataract. Refract. Surg."},{"key":"46502_CR3","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1080\/01405110410001711454","volume":"27","author":"JK Singh","year":"2004","unstructured":"Singh, J. K., Dhawahir, F. E., Hamid, A. F. & Chell, P. B. The use of dye in ophthalmology. J. Audiov. Media. Med. 27, 62\u201367 (2004).","journal-title":"J. Audiov. Media. Med."},{"key":"46502_CR4","doi-asserted-by":"publisher","first-page":"605","DOI":"10.1016\/S0161-6420(92)31947-5","volume":"99","author":"RP Feenstra","year":"1992","unstructured":"Feenstra, R. P. & Tseng, S. C. Comparison of fluorescein and rose bengal staining. Ophthalmology 99, 605\u2013617 (1992).","journal-title":"Ophthalmology"},{"key":"46502_CR5","doi-asserted-by":"publisher","first-page":"101976","DOI":"10.1016\/j.pdpdt.2020.101976","volume":"32","author":"M De Bernardo","year":"2020","unstructured":"De Bernardo, M., Borrelli, M., Imparato, R., Cione, F. & Rosa, N. Anterior chamber depth measurement before and after photorefractive keratectomy. Comparison between IOLMaster and Pentacam. Photodiagn. Photodyn. Ther. 32, 101976 (2020).","journal-title":"Photodiagn. Photodyn. Ther."},{"key":"46502_CR6","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/s40662-016-0038-6","volume":"3","author":"JK Duncan","year":"2016","unstructured":"Duncan, J. K., Belin, M. W. & Borgstrom, M. Assessing progression of keratoconus: novel tomographic determinants. Eye Vis. 3, 6 (2016).","journal-title":"Eye Vis."},{"key":"46502_CR7","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.ajo.2014.04.002","volume":"158","author":"MR Santhiago","year":"2014","unstructured":"Santhiago, M. R. et al. Association between the percent tissue altered and post-laser in situ keratomileusis ectasia in eyes with normal preoperative topography. Am. J. Ophthalmol. 158, 87-95 el (2014).","journal-title":"Am. J. Ophthalmol."},{"key":"46502_CR8","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1007\/s40123-021-00383-w","volume":"10","author":"M Moshirfar","year":"2021","unstructured":"Moshirfar, M. et al. Ectasia after corneal refractive surgery: A systematic review. Ophthalmol. Ther. 10, 753\u2013776 (2021).","journal-title":"Ophthalmol. Ther."},{"key":"46502_CR9","doi-asserted-by":"publisher","first-page":"989","DOI":"10.21037\/atm-21-2367","volume":"9","author":"J Zeng","year":"2021","unstructured":"Zeng, J. et al. Factors associated with corneal high-order aberrations before and after femtosecond laser-assisted in situ keratomileusis. Ann. Transl. Med. 9, 989 (2021).","journal-title":"Ann. Transl. Med."},{"key":"46502_CR10","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0150121","volume":"11","author":"Y Hua","year":"2016","unstructured":"Hua, Y. et al. Evaluation of equivalent keratometry readings obtained by pentacam HR (High Resolution). PLoS One 11, e0150121 (2016).","journal-title":"PLoS One"},{"issue":"41","key":"46502_CR11","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1097\/DSS.0000000000000485","volume":"2015","author":"S Beggs","year":"2015","unstructured":"Beggs, S., Short, J., Rengifo-Pardo, M. & Ehrlich, A. Applications of the excimer laser: A review. Dermatol. Surg. 2015(41), 1201\u20131211 (2015).","journal-title":"Dermatol. Surg."},{"key":"46502_CR12","doi-asserted-by":"publisher","first-page":"4536","DOI":"10.3390\/jcm12134536","volume":"12","author":"DS Cha","year":"2023","unstructured":"Cha, D. S., Moshirfar, M., Herron, M. S., Santos, J. M. & Hoopes, P. C. Prediction of posterior-to-anterior corneal curvature radii ratio in myopic patients after LASIK, SMILE, and PRK using multivariate regression analysis. J. Clin. Med. 12, 4536 (2023).","journal-title":"J. Clin. Med."},{"key":"46502_CR13","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1111\/j.1442-9071.2010.02286.x","volume":"38","author":"KG Falavarjani","year":"2010","unstructured":"Falavarjani, K. G. et al. Determining corneal power using Pentacam after myopic photorefractive keratectomy. Clin. Exp. Ophthalmol. 38, 341\u2013345 (2010).","journal-title":"Clin. Exp. Ophthalmol."},{"key":"46502_CR14","doi-asserted-by":"publisher","first-page":"2285","DOI":"10.1007\/s40123-022-00589-6","volume":"11","author":"H Hashemi","year":"2022","unstructured":"Hashemi, H., Mehravaran, S., Panahi, P., Abdollahinia, T. & Asgari, S. Long-term results of laser in situ keratomileusis in myopic patients with topographic indices outside suggested ranges. Ophthalmol. Ther. 11, 2285\u20132295 (2022).","journal-title":"Ophthalmol. Ther."},{"key":"46502_CR15","doi-asserted-by":"publisher","first-page":"1714","DOI":"10.18240\/ijo.2019.11.08","volume":"12","author":"HA Khairy","year":"2019","unstructured":"Khairy, H. A., Elsawy, M. F., Said-Ahmed, K., Zaki, M. A. & Mandour, S. S. Accelerated versus standard corneal cross linking in the treatment of ectasia post refractive surgery and penetrating keratoplasty: a medium term randomized trial. Int. J. Ophthalmol. 12, 1714\u20131719 (2019).","journal-title":"Int. J. Ophthalmol."},{"key":"46502_CR16","doi-asserted-by":"publisher","first-page":"5926508","DOI":"10.1155\/2018\/5926508","volume":"2018","author":"M Dogan","year":"2018","unstructured":"Dogan, M., Sabaner, M. C. & Erol, M. A. Effect of proparacaine 0.375%-sodium fluorescein 0.25% eye drop mixture and fluorescein strip on anterior segment parameters. J. Ophthalmol. 2018, 5926508 (2018).","journal-title":"J. Ophthalmol."},{"key":"46502_CR17","doi-asserted-by":"publisher","first-page":"1334","DOI":"10.18240\/ijo.2020.08.22","volume":"13","author":"M Niparugs","year":"2020","unstructured":"Niparugs, M. et al. Incidence and predisposing factors of anterior chamber gas bubbles during femtosecond laser flap creation. Int. J. Ophthalmol. 13, 1334\u20131337 (2020).","journal-title":"Int. J. Ophthalmol."},{"key":"46502_CR18","doi-asserted-by":"publisher","first-page":"3765046","DOI":"10.1155\/2021\/3765046","volume":"2021","author":"Y Wu","year":"2021","unstructured":"Wu, Y. et al. Corneal asphericity and higher-order aberrations after FS-LASIK and Trans-PRK for Myopia. J. Ophthalmol. 2021, 3765046 (2021).","journal-title":"J. Ophthalmol."},{"key":"46502_CR19","doi-asserted-by":"publisher","first-page":"6445","DOI":"10.1038\/s41598-020-63594-4","volume":"10","author":"WJ Whang","year":"2020","unstructured":"Whang, W. J., Yoo, Y. S., Kim, H. S. & Yoon, G. Influence of corneal spherical aberration on prediction error of the Haigis-L formula. Sci. Rep. 10, 6445 (2020).","journal-title":"Sci. Rep."},{"key":"46502_CR20","doi-asserted-by":"publisher","first-page":"2179","DOI":"10.1007\/s10792-021-01775-4","volume":"41","author":"MY Avila","year":"2021","unstructured":"Avila, M. Y. & Vivas, P. R. Visual outcomes in hyperopic myopic and emmetropic patients with customized aspheric ablation (Q factor) and micro-monovision. Int. Ophthalmol. 41, 2179\u20132185 (2021).","journal-title":"Int. Ophthalmol."},{"key":"46502_CR21","doi-asserted-by":"publisher","first-page":"612","DOI":"10.3928\/1081597X-20160531-01","volume":"32","author":"JR Jimenez","year":"2016","unstructured":"Jimenez, J. R., Alarc\u00f3n, A., Anera, R. G. & Jim\u00e9nez-Del-Barco, L. Q-optimized algorithms: theoretical analysis of factors influencing visual quality after myopic corneal refractive surgery. J. Refract. Surg. 32, 612\u2013617 (2016).","journal-title":"J. Refract. Surg."},{"key":"46502_CR22","doi-asserted-by":"publisher","first-page":"1405","DOI":"10.1364\/BOE.8.001405","volume":"8","author":"JR Jimenez","year":"2017","unstructured":"Jimenez, J. R., Alarc\u00f3n, A., Anera, R. G. & Del Barco, L. J. Hyperopic Q-optimized algorithms: a theoretical study on factors influencing optical quality. Biomed. Opt. Express. 8, 1405\u20131414 (2017).","journal-title":"Biomed. Opt. Express."},{"key":"46502_CR23","doi-asserted-by":"publisher","first-page":"882","DOI":"10.1016\/j.ophtha.2008.12.022","volume":"116","author":"S Fukuda","year":"2009","unstructured":"Fukuda, S., Kawana, K., Yasuno, Y. & Oshika, T. Anterior ocular biometry using 3-dimensional optical coherence tomography. Ophthalmology 116, 882\u2013889 (2009).","journal-title":"Ophthalmology"},{"key":"46502_CR24","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1016\/j.jcrs.2010.11.033","volume":"37","author":"DR Mukhopadhyay","year":"2011","unstructured":"Mukhopadhyay, D. R., North, R. V. & Hamilton-Maxwell, K. E. Effect of a proparacaine 0.50%-sodium fluorescein 0.25% mix and contact ultrasound pachymetry on central and midperipheral corneal thickness measured by noncontact optical pachymetry. J. Cataract. Refract. Surg. 37, 907\u2013913 (2011).","journal-title":"J. Cataract. Refract. Surg."},{"key":"46502_CR25","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1167\/iovs.08-3265","volume":"51","author":"H Zhuang","year":"2010","unstructured":"Zhuang, H., Zhou, X. & Xu, J. A novel method for pachymetry mapping of human precorneal tear film using Pentacam with fluorescein. Invest. Ophthalmol. Vis. Sci. 51, 156\u2013159 (2010).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"46502_CR26","doi-asserted-by":"publisher","first-page":"521078","DOI":"10.3389\/fmed.2020.521078","volume":"7","author":"R Wei","year":"2020","unstructured":"Wei, R. et al. Corneal densitometry after small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK (FS-LASIK): 5-year prospective comparative study. Front. Med. 7, 521078 (2020).","journal-title":"Front. Med."},{"key":"46502_CR27","doi-asserted-by":"publisher","first-page":"724","DOI":"10.1016\/j.ophtha.2019.09.006","volume":"127","author":"M Ang","year":"2020","unstructured":"Ang, M., Farook, M., Htoon, H. M. & Mehta, J. S. Randomized clinical trial comparing femtosecond LASIK and small-incision lenticule extraction. Ophthalmology 127, 724\u2013730 (2020).","journal-title":"Ophthalmology"},{"key":"46502_CR28","doi-asserted-by":"publisher","first-page":"S426","DOI":"10.1097\/ICL.0000000000000532","volume":"44","author":"E El-Mayah","year":"2018","unstructured":"El-Mayah, E., Anis, M., Salem, M., Pinero, D. & Hosny, M. Comparison between Q-adjusted lasik and small-incision lenticule extraction for correction of myopia and myopic astigmatism. Eye Contact Lens. 44, S426\u2013S432 (2018).","journal-title":"Eye Contact Lens."},{"key":"46502_CR29","doi-asserted-by":"publisher","first-page":"1047","DOI":"10.18240\/ijo.2021.07.13","volume":"14","author":"PF Zhao","year":"2021","unstructured":"Zhao, P. F. et al. Evaluation of preoperative dry eye in people undergoing corneal refractive surgery to correct myopia. Int. J. Ophthalmol. 14, 1047\u20131051 (2021).","journal-title":"Int. J. Ophthalmol."},{"key":"46502_CR30","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1016\/j.clae.2014.08.006","volume":"38","author":"M De-Bernardo","year":"2015","unstructured":"De-Bernardo, M., Borrelli, M., Mariniello, M., Lanza, M. & Rosa, N. Pentacam vs SP3000P specular microscopy in measuring corneal thickness. Contact Lens. Anterio. 38, 21\u201327 (2015).","journal-title":"Contact Lens. Anterio."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-46502-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-46502-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-46502-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,4]],"date-time":"2023-11-04T11:02:32Z","timestamp":1699095752000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-46502-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,4]]},"references-count":30,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["46502"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-46502-4","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2282433\/v1","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,4]]},"assertion":[{"value":"17 November 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 November 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 November 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"19099"}}