{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T16:08:28Z","timestamp":1787587708286,"version":"build-2736575974"},"reference-count":51,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,11,9]],"date-time":"2023-11-09T00:00:00Z","timestamp":1699488000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,11,9]],"date-time":"2023-11-09T00:00:00Z","timestamp":1699488000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100008641","name":"Chung Shan Medical University","doi-asserted-by":"publisher","award":["FCU\/CSMU-111-002"],"award-info":[{"award-number":["FCU\/CSMU-111-002"]}],"id":[{"id":"10.13039\/501100008641","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100008641","name":"Chung Shan Medical University","doi-asserted-by":"publisher","award":["FCU\/CSMU-111-002"],"award-info":[{"award-number":["FCU\/CSMU-111-002"]}],"id":[{"id":"10.13039\/501100008641","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>This study investigated the influence of large-diameter multifocal contact lenses on the ocular surface, visual quality, and visual function for presbyopic adults with dry eye syndromes. The study enrolled 40\u201355-year-old adults with presbyopia and dry eye syndromes (DES). The subjects were randomly assigned to three groups wearing different designs of contact lenses (Proclear, SMR, and Optimum) for 6\u20138\u00a0h\u00a0a day for two weeks. Ocular surface health, tear quality, visual quality, and visual function were measured before and after lens wear. No significant difference was observed across all three groups for the amount of conjunctival redness, blink frequency (lens on), and stereopsis vision before and after wearing. Although there seemed to be a significant declining trend for corneal staining and limbal redness, non-invasive tear break-up time (TBUT), and lipid layer thickness while lens wear, the measured values were all within the normal range. Vice-versa after lens removal, results also showed significant improvement on lipid layer thickness, blink frequency (lens off), and contact TBUT. A significant improvement was observed in the modulation transfer function (MTF) of the total area ratio after wearing contact lenses. In contrast, the MTF of the high-order aberration area ratio resulting from lens wear was lower than that of the baseline measurement. There are also significant improvements observed for SMR and Optimum regarding near visual acuity, near point of accommodation, and the subjective questionnaire (OSDI and VBP) scores. Although it is difficult to avoid a specific negative impact on the ocular surface and tear film, visual function and visual quality can still be positively improved, especially shown on larger diameter and distance-center designed multifocal contact lenses.<\/jats:p>","DOI":"10.1038\/s41598-023-46732-6","type":"journal-article","created":{"date-parts":[[2023,11,9]],"date-time":"2023-11-09T11:02:38Z","timestamp":1699527758000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["The influence of large-diameter multifocal contact lens on ocular surface, visual quality, and visual function for presbyopic adults with dry eye syndromes"],"prefix":"10.1038","volume":"13","author":[{"given":"Ching-Jen","family":"Hsiao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hsiao-Ching","family":"Tung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chuen\u2010Lin","family":"Tien","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu-Wen","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ching-Ying","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,11,9]]},"reference":[{"issue":"12","key":"46732_CR1","doi-asserted-by":"publisher","first-page":"e1221","DOI":"10.1016\/S2214-109X(17)30393-5","volume":"5","author":"SR Flaxman","year":"2017","unstructured":"Flaxman, S. R. et al. Global causes of blindness and distance vision impairment 1990\u20132020: A systematic review and meta-analysis. Lancet Glob. Health 5(12), e1221\u2013e1234 (2017).","journal-title":"Lancet Glob. Health"},{"issue":"4","key":"46732_CR2","first-page":"Cd009877","volume":"4","author":"P Heus","year":"2018","unstructured":"Heus, P., Verbeek, J. H. & Tikka, C. Optical correction of refractive error for preventing and treating eye symptoms in computer users. Cochrane Database Syst. Rev. 4(4), Cd009877 (2018).","journal-title":"Cochrane Database Syst. Rev."},{"issue":"24","key":"46732_CR3","doi-asserted-by":"publisher","first-page":"5161","DOI":"10.3390\/ijerph16245161","volume":"16","author":"B Mohd-Ali","year":"2019","unstructured":"Mohd-Ali, B. & Tan, X. L. Patterns of use and knowledge about contact lens wear amongst teenagers in rural areas in Malaysia. Int. J. Environ. Res. Public Health 16(24), 5161 (2019).","journal-title":"Int. J. Environ. Res. Public Health"},{"issue":"2","key":"46732_CR4","doi-asserted-by":"publisher","first-page":"261","DOI":"10.3390\/ma12020261","volume":"12","author":"CSA Musgrave","year":"2019","unstructured":"Musgrave, C. S. A. & Fang, F. Contact lens materials: A materials science perspective. Materials 12(2), 261 (2019).","journal-title":"Materials"},{"key":"46732_CR5","unstructured":"Pamela, A. & Lowe, O. Priorities for presbyopes: Maintain comfort and continuity. August 15, 2016; Available from: https:\/\/www.reviewofoptometry.com\/article\/priorities-for-presbyopes-maintain-comfort-and-continuity."},{"issue":"9","key":"46732_CR6","doi-asserted-by":"publisher","first-page":"1264","DOI":"10.1001\/archopht.118.9.1264","volume":"118","author":"SE Moss","year":"2000","unstructured":"Moss, S. E. Prevalence of and risk factors for dry eye syndrome. Arch. Ophthalmol. 118(9), 1264 (2000).","journal-title":"Arch. Ophthalmol."},{"issue":"3","key":"46732_CR7","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1111\/j.1444-0938.2007.00242.x","volume":"91","author":"ES Bennett","year":"2008","unstructured":"Bennett, E. S. Contact lens correction of presbyopia. Clin. Exp. Optom. 91(3), 265\u2013278 (2008).","journal-title":"Clin. Exp. Optom."},{"issue":"3","key":"46732_CR8","first-page":"18","volume":"8","author":"WB Chang","year":"2012","unstructured":"Chang, W. B. et al. An analysis of drug expenses in the National Health Insurance Database for dry eye syndrome patients in 2008. Chang Gung Med. J. 8(3), 18\u201326 (2012).","journal-title":"Chang Gung Med. J."},{"issue":"1","key":"46732_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12886-016-0364-4","volume":"16","author":"JH Moon","year":"2016","unstructured":"Moon, J. H., Kim, K. W. & Moon, N. J. Smartphone use is a risk factor for pediatric dry eye disease according to region and age: A case control study. BMC Ophthalmol. 16(1), 1\u20137 (2016).","journal-title":"BMC Ophthalmol."},{"key":"46732_CR10","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/j.ajo.2017.06.033","volume":"182","author":"KF Farrand","year":"2017","unstructured":"Farrand, K. F. et al. Prevalence of diagnosed dry eye disease in the United States among adults aged 18 years and older. Am. J. Ophthalmol. 182, 90\u201398 (2017).","journal-title":"Am. J. Ophthalmol."},{"key":"46732_CR11","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1016\/j.ajo.2019.01.026","volume":"202","author":"R Dana","year":"2019","unstructured":"Dana, R. et al. Estimated prevalence and incidence of dry eye disease based on coding analysis of a large, all-age United States Health Care System. Am. J. Ophthalmol. 202, 47\u201354 (2019).","journal-title":"Am. J. Ophthalmol."},{"issue":"12","key":"46732_CR12","doi-asserted-by":"publisher","first-page":"2731","DOI":"10.1007\/s10792-019-01117-5","volume":"39","author":"ELC Mai","year":"2019","unstructured":"Mai, E. L. C. et al. Population-based study on the epidemiology of dry eye disease and its association with presbyopia and other risk factors. Int. Ophthalmol. 39(12), 2731\u20132739 (2019).","journal-title":"Int. Ophthalmol."},{"issue":"5","key":"46732_CR13","doi-asserted-by":"publisher","first-page":"463","DOI":"10.1111\/cxo.12851","volume":"102","author":"S Jaiswal","year":"2019","unstructured":"Jaiswal, S. et al. Ocular and visual discomfort associated with smartphones, tablets and computers: What we do and do not know. Clin. Exp. Optom. 102(5), 463\u2013477 (2019).","journal-title":"Clin. Exp. Optom."},{"issue":"5","key":"46732_CR14","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1111\/j.1475-1313.2011.00834.x","volume":"31","author":"M Rosenfield","year":"2011","unstructured":"Rosenfield, M. Computer vision syndrome: a review of ocular causes and potential treatments. Ophthalmic. Physiol. Opt. 31(5), 502\u2013515 (2011).","journal-title":"Ophthalmic. Physiol. Opt."},{"issue":"1","key":"46732_CR15","doi-asserted-by":"publisher","DOI":"10.1136\/bmjophth-2018-000146","volume":"3","author":"AL Sheppard","year":"2018","unstructured":"Sheppard, A. L. & Wolffsohn, J. S. Digital eye strain: Prevalence, measurement and amelioration. BMJ Open Ophthalmol. 3(1), e000146 (2018).","journal-title":"BMJ Open Ophthalmol."},{"key":"46732_CR16","doi-asserted-by":"publisher","first-page":"861","DOI":"10.2147\/OPTH.S128939","volume":"11","author":"M Kaido","year":"2017","unstructured":"Kaido, M. et al. Severe symptoms of short tear break-up time dry eye are associated with accommodative microfluctuations. Clin. Ophthalmol. 11, 861\u2013869 (2017).","journal-title":"Clin. Ophthalmol."},{"key":"46732_CR17","doi-asserted-by":"crossref","unstructured":"Messmer, E. M. The pathophysiology, diagnosis, and treatment of dry eye disease. Deutsches Aerzteblatt Online (2015).","DOI":"10.3238\/arztebl.2015.0071"},{"issue":"12","key":"46732_CR18","doi-asserted-by":"publisher","first-page":"2899","DOI":"10.4103\/ijo.IJO_2629_20","volume":"68","author":"S D'Souza","year":"2020","unstructured":"D\u2019Souza, S. et al. Study of tear film optics and its impact on quality of vision. Indian J. Ophthalmol. 68(12), 2899\u20132902 (2020).","journal-title":"Indian J. Ophthalmol."},{"key":"46732_CR19","doi-asserted-by":"publisher","first-page":"85","DOI":"10.2147\/OPTO.S198637","volume":"12","author":"AD Pucker","year":"2020","unstructured":"Pucker, A. D. & Tichenor, A. A. A review of contact lens dropout. Clin. Optom. 12, 85\u201394 (2020).","journal-title":"Clin. Optom."},{"key":"46732_CR20","unstructured":"Bausch + Lomb Ultra Contact lenses. Available from: http:\/\/www.bausch.com.tw\/zh-tw\/our-products\/contact-lenses\/lenses-for-short-sighted-long-sighted\/ultra-soft-contact-lenses\/."},{"key":"46732_CR21","unstructured":"Alcon Dailies Total 1 Available from: https:\/\/alcon-vc.com.tw\/dailiestotal1\/."},{"key":"46732_CR22","unstructured":"Poclear Contact lenses. Available from: https:\/\/coopervision.com.tw\/contact-lenses\/%E5%AF%B6%E6%99%B4%E7%B3%BB%E5%88%97\/%E5%AF%B6%E6%99%B4%E6%97%A5%E6%8B%8B."},{"issue":"5","key":"46732_CR23","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/j.clae.2010.06.009","volume":"33","author":"N Efron","year":"2010","unstructured":"Efron, N. Obituary\u2013rigid contact lenses. Cont. Lens Anterior Eye 33(5), 245\u2013252 (2010).","journal-title":"Cont. Lens Anterior Eye"},{"issue":"6","key":"46732_CR24","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1111\/cxo.12512","volume":"100","author":"G Carracedo","year":"2017","unstructured":"Carracedo, G. et al. Post-lens tear turbidity and visual quality after Optimum lens wear. Clin. Exp. Optom. 100(6), 577\u2013582 (2017).","journal-title":"Clin. Exp. Optom."},{"issue":"6","key":"46732_CR25","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.clae.2012.07.006","volume":"35","author":"F Alipour","year":"2012","unstructured":"Alipour, F., Kheirkhah, A. & Jabarvand Behrouz, M. Use of mini optimum contact lenses in moderate to severe dry eye. Cont. Lens Anterior Eye 35(6), 272\u2013276 (2012).","journal-title":"Cont. Lens Anterior Eye"},{"issue":"1","key":"46732_CR26","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1097\/ICL.0000000000000083","volume":"41","author":"MM Schornack","year":"2015","unstructured":"Schornack, M. M. Optimum lenses: A literature review. Eye Contact Lens 41(1), 3\u201311 (2015).","journal-title":"Eye Contact Lens"},{"issue":"6","key":"46732_CR27","doi-asserted-by":"publisher","first-page":"372","DOI":"10.1097\/ICL.0000000000000436","volume":"44","author":"E Shorter","year":"2018","unstructured":"Shorter, E. et al. Optimum lenses in the management of corneal irregularity and ocular surface disease. Eye Contact Lens 44(6), 372\u2013378 (2018).","journal-title":"Eye Contact Lens"},{"issue":"1","key":"46732_CR28","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.clae.2017.09.014","volume":"41","author":"E Lafosse","year":"2018","unstructured":"Lafosse, E. et al. Comparison of the influence of corneo-Optimum and Optimum lenses on ocular surface and tear film metrics in a presbyopic population. Contact Lens Anterior Eye 41(1), 122\u2013127 (2018).","journal-title":"Contact Lens Anterior Eye"},{"issue":"5","key":"46732_CR29","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1016\/j.clae.2019.04.001","volume":"42","author":"M Serramito","year":"2019","unstructured":"Serramito, M. et al. Corneal surface wettability and tear film stability before and after Optimum lens wear. Contact Lens Anterior Eye 42(5), 520\u2013525 (2019).","journal-title":"Contact Lens Anterior Eye"},{"issue":"Suppl 1","key":"46732_CR30","doi-asserted-by":"publisher","first-page":"S228","DOI":"10.1097\/ICL.0000000000000387","volume":"44","author":"J Harthan","year":"2018","unstructured":"Harthan, J. et al. Optimum lens prescription and management practices: The SCOPE Study. Eye Contact Lens 44(Suppl 1), S228\u2013S232 (2018).","journal-title":"Eye Contact Lens"},{"key":"46732_CR31","doi-asserted-by":"crossref","unstructured":"Erdinest, N. et al. Quadrant asymmetric design contact lens for visual rehabilitation after eye trauma. Case Rep. Ophthalmol., 330\u2013336 (2021).","DOI":"10.1159\/000512505"},{"key":"46732_CR32","doi-asserted-by":"crossref","unstructured":"Uysal, B. S., Yaman, D., Kalkan Akcay, E., Kilicarslan, A., Sarac, O. & Cagil, N. Evaluation of corneal topography, tear film function and conjunctival impression cytology after long-term Optimum contact lens wear in keratoconus patients. Semin. Ophthalmol. 27, 1\u20137 (2021).","DOI":"10.1080\/08820538.2021.1890148"},{"issue":"4","key":"46732_CR33","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1097\/ICU.0000000000000171","volume":"26","author":"JC Bavinger","year":"2015","unstructured":"Bavinger, J. C., DeLoss, K. & Mian, S. I. Optimum lens use in dry eye syndrome. Curr. Opin. Ophthalmol. 26(4), 319\u2013324 (2015).","journal-title":"Curr. Opin. Ophthalmol."},{"issue":"3","key":"46732_CR34","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1097\/ICL.0000000000000323","volume":"44","author":"L Michaud","year":"2018","unstructured":"Michaud, L. et al. Clinical evaluation of large diameter rigid-gas permeable versus soft toric contact lenses for the correction of refractive astigmatism. A multicentre study. Eye Contact Lens. 44(3), 164\u2013169. https:\/\/doi.org\/10.1097\/ICL.0000000000000323 (2018).","journal-title":"Eye Contact Lens."},{"key":"46732_CR35","first-page":"62","volume":"279","author":"A Sunjic-Alic","year":"2021","unstructured":"Sunjic-Alic, A., Zebenholzer, K. & Gall, W. Reporting of studies conducted on Austrian claims data. Stud. Health Technol. Inform. 279, 62\u201369 (2021).","journal-title":"Stud. Health Technol. Inform."},{"issue":"1","key":"46732_CR36","doi-asserted-by":"publisher","first-page":"S31","DOI":"10.4103\/sja.SJA_543_18","volume":"13","author":"ST Cuschieri","year":"2019","unstructured":"Cuschieri, S. T. STROBE guidelines. Saudi J. Anaesth. 13(1), S31\u2013S34 (2019).","journal-title":"Saudi J. Anaesth."},{"key":"46732_CR37","doi-asserted-by":"publisher","DOI":"10.1155\/2018\/4728258","author":"Z Xu","year":"2018","unstructured":"Xu, Z. et al. Comparison of the clinical performance of refractive rotationally asymmetric multifocal IOLs with other types of IOLs: A meta-analysis. J. Ophthalmol. https:\/\/doi.org\/10.1155\/2018\/4728258 (2018).","journal-title":"J. Ophthalmol."},{"issue":"5","key":"46732_CR38","doi-asserted-by":"publisher","first-page":"633","DOI":"10.1038\/sj.eye.6702295","volume":"21","author":"PJ Murphy","year":"2007","unstructured":"Murphy, P. J. et al. How red is a white eye? Clinical grading of normal conjunctival hyperaemia. Eye 21(5), 633\u2013638 (2007).","journal-title":"Eye"},{"key":"46732_CR39","doi-asserted-by":"publisher","first-page":"17","DOI":"10.2147\/OPTO.S235167","volume":"12","author":"C M\u00fcller","year":"2020","unstructured":"M\u00fcller, C. et al. Subjective comparison of pre-lens tear film stability of daily disposable contact lenses using ring mire projection. Clin. Optom. (Auckl.) 12, 17\u201326 (2020).","journal-title":"Clin. Optom. (Auckl.)"},{"issue":"4","key":"46732_CR40","doi-asserted-by":"publisher","first-page":"1319","DOI":"10.1167\/iovs.05-1392","volume":"47","author":"JJ Nichols","year":"2006","unstructured":"Nichols, J. J. & Sinnott, L. T. Tear film, contact lens, and patient-related factors associated with contact lens\u2013related dry rye. Investig. Opthalmol. Vis. Sci. 47(4), 1319 (2006).","journal-title":"Investig. Opthalmol. Vis. Sci."},{"issue":"3","key":"46732_CR41","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1097\/ICL.0b013e31828af164","volume":"39","author":"A Rohit","year":"2013","unstructured":"Rohit, A., Wilcoxon, M. & Stapleton, F. Tear lipid layer and contact lens comfort: A review. Eye Contact Lens 39(3), 247\u2013253 (2013).","journal-title":"Eye Contact Lens"},{"issue":"3","key":"46732_CR42","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1097\/00006324-199603000-00011","volume":"73","author":"DR Korb","year":"1996","unstructured":"Korb, D. R., Greiner, J. V. & Glonek, T. Tear film lipid layer formation: Implications for contact lens wear. Optom. Vis. Sci. 73(3), 189\u2013192. https:\/\/doi.org\/10.1097\/00006324-199603000-00011 (1996).","journal-title":"Optom. Vis. Sci."},{"key":"46732_CR43","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.preteyeres.2014.11.001","volume":"45","author":"RJ Braun","year":"2015","unstructured":"Braun, R. J. et al. Dynamics and function of the tear film in relation to the blink cycle. Prog. Retina Eye Res. 45, 132\u2013164 (2015).","journal-title":"Prog. Retina Eye Res."},{"issue":"6","key":"46732_CR44","doi-asserted-by":"publisher","first-page":"718","DOI":"10.1111\/opo.12729","volume":"40","author":"JV Garc\u00eda-Marqu\u00e9s","year":"2020","unstructured":"Garc\u00eda-Marqu\u00e9s, J. V. et al. Comparison of short-term light disturbance, optical and visual performance outcomes between a myopia control contact lens and a single-vision contact lens. Ophthal. Physiol. Opt. 40(6), 718\u2013727 (2020).","journal-title":"Ophthal. Physiol. Opt."},{"issue":"2","key":"46732_CR45","doi-asserted-by":"publisher","first-page":"100","DOI":"10.1111\/j.1475-1313.2011.00889.x","volume":"32","author":"A Jinabhai","year":"2012","unstructured":"Jinabhai, A., Radhakrishnan, H., Tromans, C. & O\u2019Donnell, C. Visual performance and optical quality with soft lenses in keratoconus patients. Ophthal. Physiol. Opt. 32(2), 100\u2013116 (2012).","journal-title":"Ophthal. Physiol. Opt."},{"issue":"9","key":"46732_CR46","doi-asserted-by":"publisher","first-page":"e214","DOI":"10.1097\/OPX.0000000000000671","volume":"92","author":"EM Rueff","year":"2015","unstructured":"Rueff, E. M., King-Smith, P. E. & Bailey, M. D. Can binocular vision disorders contribute to contact lens discomfort?. Optom. Vis. Sci. 92(9), e214\u2013e221 (2015).","journal-title":"Optom. Vis. Sci."},{"issue":"8","key":"46732_CR47","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1097\/01.opx.0000232185.00091.45","volume":"83","author":"ASMB Rajagopalan","year":"2006","unstructured":"Rajagopalan, A. S. M. B. & Edward, S. Visual performance of subjects wearing presbyopic contact lenses. Optom. Vis. Sci. 83(8), 611\u2013615 (2006).","journal-title":"Optom. Vis. Sci."},{"issue":"3","key":"46732_CR48","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1016\/j.clae.2013.09.013","volume":"37","author":"MF Balamurali Vasudevan","year":"2014","unstructured":"Balamurali Vasudevan, M. F. Sara Gaib Objective and subjective visual performance of multifocal contact lenses: Pilot study. Contact Lens Anterior Eye 37(3), 168\u2013174 (2014).","journal-title":"Contact Lens Anterior Eye"},{"issue":"8","key":"46732_CR49","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1097\/OPX.0b013e31821c0ed8","volume":"88","author":"R Mont\u00e9s-Mic\u00f3","year":"2011","unstructured":"Mont\u00e9s-Mic\u00f3, R., Madrid-Costa, D., Radhakrishnan, H., Charman, W. N. & Ferrer-Blasco, T. Accommodative functions with multifocal contact lenses: A pilot study. Optom. Vis. Sci. 88(8), 998\u20131004 (2011).","journal-title":"Optom. Vis. Sci."},{"issue":"11","key":"46732_CR50","doi-asserted-by":"publisher","first-page":"1309","DOI":"10.1097\/OPX.0b013e31822be35a","volume":"88","author":"D Madrid-Costa","year":"2011","unstructured":"Madrid-Costa, D., Ruiz-Alcocer, J., Radhakrishnan, H., Ferrer-Blasco, T. & Montes-Mico, R. Changes in accommodative responses with multifocal contact lenses: A pilot study. Optom. Vis. Sci. 88(11), 1309\u20131316 (2011).","journal-title":"Optom. Vis. Sci."},{"key":"46732_CR51","unstructured":"Efron, N. Contact Lens Practice, 3rd Edition. 2016\/11\/27: Elsevier."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-46732-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-46732-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-46732-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,9]],"date-time":"2023-11-09T11:07:33Z","timestamp":1699528053000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-46732-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,9]]},"references-count":51,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["46732"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-46732-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,9]]},"assertion":[{"value":"21 May 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 November 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 November 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"19444"}}