{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,5]],"date-time":"2026-10-05T11:07:43Z","timestamp":1791198463849,"version":"4.1.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,11,10]],"date-time":"2023-11-10T00:00:00Z","timestamp":1699574400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,11,10]],"date-time":"2023-11-10T00:00:00Z","timestamp":1699574400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"VSY Biotechnology","award":["VSY1-22TPA"],"award-info":[{"award-number":["VSY1-22TPA"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>The purpose of this study was to investigate and compare the optical performance of five trifocal intraocular lenses (IOLs) following the ISO 11979-2 standards, analysing the impact of tilt and decentration. Five different diffractive trifocal IOLs were evaluated in this experimental study: Acriva Trinova (VSY-Biotechnology) (AT), FineVision HP (PhysIOL) (FVHP), AT LISA tri 839 MP (Zeiss) (ATLT), PanOptix TFNT00 IOL (Alcon) (PO), and Tecnis Synergy (J&amp;J Vision) (TS). In-vitro optical quality analysis of them was performed with the Lambda PMTF system that has an aberration neutral cornea model (Lambda-X Ophthalmics). Measurements were performed on-axis, with 5\u00ba of IOL tilt and with 0.5\u00a0mm of IOL decentration using 543-nm monochromatic light. Finally, IOL dimensions and diffractive disk profile inspection was performed using the VisIOLA system (Rotlex). On-axis measurements showed a far through-focus MTF\u2009&gt;\u20090.3 at 3\u00a0mm aperture, except for TS. FVHP and PO showed better far MTFs for larger apertures (3.75\u00a0mm and 4.5\u00a0mm) while AT showed good intermediate and near vision for such apertures. With 5\u00ba of IOL tilt, the better optical performance at all distances was found with AT for medium-sized pupils (3\u00a0mm) and an important reduction of MTF was found for ATLT and PO, especially in the intermediate focus. The induction of 0.5\u00a0mm of IOL decentration especially affected the intermediate focus of ATLT and TS and the far focus of FVHP and PO. IOL dimensions and diffractive profile were consistent with those described by the manufacturer. In conclusion, there are differences in the optical performance according to the pupil aperture of the five trifocal IOLs evaluated and this should be considered in clinical practice when selecting the most appropriate implant in each specific case. IOL tilt and decentration can affect significantly in most of the designs evaluated the performance of the IOL at intermediate vision range. It should be noted that measurements were made with an aberration-free cornea, being necessary future studies analysing the impact of different levels of corneal aberrations.<\/jats:p>","DOI":"10.1038\/s41598-023-47102-y","type":"journal-article","created":{"date-parts":[[2023,11,10]],"date-time":"2023-11-10T12:02:32Z","timestamp":1699617752000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":32,"title":["Comparison of the optical behaviour of five different multifocal diffractive intraocular lenses in a model eye"],"prefix":"10.1038","volume":"13","author":[{"given":"Efe","family":"Can","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Esat Can","family":"Senel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sven T. S.","family":"Holmstr\u00f6m","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David P.","family":"Pi\u00f1ero","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,11,10]]},"reference":[{"key":"47102_CR1","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1016\/j.survophthal.2019.02.012","volume":"64","author":"K Cao","year":"2019","unstructured":"Cao, K. et al. Multifocal versus monofocal intraocular lenses for age-related cataract patients: a system review and meta-analysis based on randomized controlled trials. Surv Ophthalmol 64, 647\u2013658 (2019).","journal-title":"Surv Ophthalmol"},{"key":"47102_CR2","doi-asserted-by":"publisher","first-page":"1469","DOI":"10.1016\/j.ophtha.2021.03.013","volume":"128","author":"JM Schallhorn","year":"2021","unstructured":"Schallhorn, J. M. et al. Multifocal and accommodating intraocular lenses for the treatment of presbyopia: a report by the American Academy of Ophthalmology. Ophthalmology 128, 1469\u20131482 (2021).","journal-title":"Ophthalmology"},{"key":"47102_CR3","doi-asserted-by":"crossref","unstructured":"Camps, V. J., Miret, J. J., Caballero, M. T., Pi\u00f1ero, D. P., Garc\u00eda, C. Multifocal intraocular lenses: basic principles. In: Multifocal intraocular lenses. The art and the practice (eds Ali\u00f3, J. L., Pikkel, J.) (Springer Nature, Cham, 2019).","DOI":"10.1007\/978-3-030-21282-7_3"},{"key":"47102_CR4","doi-asserted-by":"publisher","first-page":"1212","DOI":"10.3390\/jcm11051212","volume":"11","author":"D Montagud-Mart\u00ednez","year":"2022","unstructured":"Montagud-Mart\u00ednez, D. et al. In vitro chromatic performance of three presbyopia-correcting intraocular lenses with different optical designs. J Clin Med 11, 1212 (2022).","journal-title":"J Clin Med"},{"key":"47102_CR5","doi-asserted-by":"publisher","first-page":"532","DOI":"10.3928\/1081597X-20210518-03","volume":"37","author":"J Ruiz-Alcocer","year":"2021","unstructured":"Ruiz-Alcocer, J., Mart\u00ednez-Alberquilla, I., Rementer\u00eda-Capelo, L. A., De Gracia, P. & Lorente-Vel\u00e1zquez, A. Changes in optical quality induced by tilt and decentration of a trifocal IOL and a novel extended depth of focus IOL in eyes with corneal myopic ablations. J Refract Surg 37, 532\u2013537 (2021).","journal-title":"J Refract Surg"},{"key":"47102_CR6","doi-asserted-by":"publisher","first-page":"435","DOI":"10.3928\/1081597X-20200519-02","volume":"36","author":"J Ruiz-Alcocer","year":"2020","unstructured":"Ruiz-Alcocer, J., Lorente-Vel\u00e1zquez, A., Hern\u00e1ndez-Verdejo, J. L., De Gracia, P. & Madrid-Costa, D. Optical performance of a trifocal IOL and a novel extended depth of focus IOL combined with different corneal profiles. J Refract Surg 36, 435\u2013441 (2020).","journal-title":"J Refract Surg"},{"key":"47102_CR7","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1007\/s00347-017-0573-0","volume":"115","author":"R Khoramnia","year":"2018","unstructured":"Khoramnia, R. et al. Optical quality of three trifocal intraocular lens models: an optical bench comparison. Ophthalmologe 115, 21\u201328 (2018).","journal-title":"Ophthalmologe"},{"key":"47102_CR8","doi-asserted-by":"publisher","first-page":"1361","DOI":"10.1016\/j.jcrs.2016.06.036","volume":"42","author":"D Carson","year":"2016","unstructured":"Carson, D. et al. Optical bench performance of 3 trifocal intraocular lenses. J Cataract Refract Surg 42, 1361\u20131367 (2016).","journal-title":"J Cataract Refract Surg"},{"key":"47102_CR9","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.2147\/OPTH.S106646","volume":"10","author":"S Lee","year":"2016","unstructured":"Lee, S. et al. Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens. Clin Ophthalmol 10, 1031\u20131038 (2016).","journal-title":"Clin Ophthalmol"},{"key":"47102_CR10","doi-asserted-by":"publisher","first-page":"1552","DOI":"10.1097\/OPX.0000000000001004","volume":"93","author":"C Ortiz","year":"2016","unstructured":"Ortiz, C., Esteve-Taboada, J. J., Belda-Salmer\u00f3n, L., Mons\u00e1lvez-Rom\u00edn, D. & Dom\u00ednguez-Vicent, A. Effect of decentration on the optical quality of two intraocular lenses. Optom Vis Sci 93, 1552\u20131559 (2016).","journal-title":"Optom Vis Sci"},{"key":"47102_CR11","doi-asserted-by":"publisher","first-page":"808","DOI":"10.3928\/1081597X-20171004-02","volume":"33","author":"T Tandogan","year":"2017","unstructured":"Tandogan, T. et al. Laboratory evaluation of the influence of decentration and pupil size on the optical performance of a monofocal, bifocal, and trifocal intraocular lens. J Refract Surg 33, 808\u2013812 (2017).","journal-title":"J Refract Surg"},{"key":"47102_CR12","doi-asserted-by":"publisher","first-page":"3639","DOI":"10.12998\/wjcc.v10.i12.3639","volume":"10","author":"XY Chen","year":"2022","unstructured":"Chen, X. Y., Wang, Y. C., Zhao, T. Y., Wang, Z. Z. & Wang, W. Tilt and decentration with various intraocular lenses: A narrative review. World J Clin Cases 10, 3639\u20133646 (2022).","journal-title":"World J Clin Cases"},{"key":"47102_CR13","doi-asserted-by":"publisher","first-page":"41","DOI":"10.3390\/vision4030041","volume":"4","author":"Z Ashena","year":"2020","unstructured":"Ashena, Z., Maqsood, S., Ahmed, S. N. & Nanavaty, M. A. Effect of intraocular lens tilt and decentration on visual acuity, dysphotopsia and wavefront aberrations. Vision 4, 41 (2020).","journal-title":"Vision"},{"key":"47102_CR14","doi-asserted-by":"publisher","first-page":"68","DOI":"10.3126\/nepjoph.v3i1.4281","volume":"3","author":"JB Ale","year":"2011","unstructured":"Ale, J. B. Intraocular lens tilt and decentration: A concern for contemporary IOL designs. Nepal J Ophthalmol 3, 68\u201377 (2011).","journal-title":"Nepal J Ophthalmol"},{"key":"47102_CR15","doi-asserted-by":"publisher","first-page":"1006","DOI":"10.1016\/j.jcrs.2009.01.023","volume":"35","author":"M Baumeister","year":"2009","unstructured":"Baumeister, M., B\u00fchren, J. & Kohnen, T. Tilt and decentration of spherical and aspheric intraocular lenses: Effect on higher-order aberrations. J Cataract Refract Surg 35, 1006\u20131012 (2009).","journal-title":"J Cataract Refract Surg"},{"key":"47102_CR16","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1016\/j.jcrs.2018.10.049","volume":"45","author":"T Lawu","year":"2019","unstructured":"Lawu, T., Mukai, K., Matsushima, H. & Senoo, T. Effects of decentration and tilt on the optical performance of 6 aspheric intraocular lens designs in a model eye. J Cataract Refract Surg 45, 662\u2013668 (2019).","journal-title":"J Cataract Refract Surg"},{"key":"47102_CR17","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.1016\/S0161-6420(91)32181-X","volume":"98","author":"DD Koch","year":"1991","unstructured":"Koch, D. D., Samuelson, S. W., Haft, E. A. & Merin, L. M. Pupillary and responsiveness: Implications for selection of a bifocal intraocular lens. Ophthalmology 98, 1030\u20131035 (1991).","journal-title":"Ophthalmology"},{"key":"47102_CR18","doi-asserted-by":"publisher","first-page":"3338","DOI":"10.1364\/BOE.421942","volume":"12","author":"F Vega","year":"2021","unstructured":"Vega, F., Valentino, M., Rigato, F. & Mill\u00e1n, M. S. Optical design and performance of a trifocal sinusoidal diffractive intraocular lens. Biomed Opt Express 12, 3338\u20133351 (2021).","journal-title":"Biomed Opt Express"},{"key":"47102_CR19","doi-asserted-by":"publisher","first-page":"1650","DOI":"10.1016\/j.jcrs.2019.06.002","volume":"45","author":"J Loicq","year":"2019","unstructured":"Loicq, J., Willet, N. & Gatinel, D. Topography and longitudinal chromatic aberration characterizations of refractive-diffractive multifocal intraocular lenses. J Cataract Refract Surg 45, 1650\u20131659 (2019).","journal-title":"J Cataract Refract Surg"},{"key":"47102_CR20","doi-asserted-by":"publisher","first-page":"2060","DOI":"10.1016\/j.jcrs.2011.05.047","volume":"37","author":"D Gatinel","year":"2011","unstructured":"Gatinel, D., Pagnoulle, C., Houbrechts, Y. & Gobin, L. Design and qualification of a diffractive trifocal optical profile for intraocular lenses. J Cataract Refract Surg 37, 2060\u20132067 (2011).","journal-title":"J Cataract Refract Surg"},{"key":"47102_CR21","doi-asserted-by":"publisher","first-page":"666","DOI":"10.3928\/1081597X-20140903-06","volume":"30","author":"P Mojzis","year":"2014","unstructured":"Mojzis, P., Kukuckova, L., Majerova, K., Liehneova, K. & Pi\u00f1ero, D. P. Comparative analysis of the visual performance after cataract surgery with implantation of a bifocal or trifocal diffractive IOL. J Refract Surg 30, 666\u2013672 (2014).","journal-title":"J Refract Surg"},{"key":"47102_CR22","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.20.2.025008","volume":"20","author":"VP Osipov","year":"2015","unstructured":"Osipov, V. P. et al. Application of nanoimprinting technique for fabrication of trifocal diffractive lens with sine-like radial profile. J Biomed Opt 20, 025008 (2015).","journal-title":"J Biomed Opt"},{"key":"47102_CR23","doi-asserted-by":"publisher","first-page":"256","DOI":"10.3928\/1081597X-20210209-01","volume":"37","author":"N Gabri\u0107","year":"2021","unstructured":"Gabri\u0107, N. et al. Clinical outcomes with a new continuous range of vision presbyopia-correcting intraocular lens. J Refract Surg 37, 256\u2013262 (2021).","journal-title":"J Refract Surg"},{"key":"47102_CR24","doi-asserted-by":"publisher","first-page":"8654","DOI":"10.1038\/s41598-022-12694-4","volume":"12","author":"JJ Miret","year":"2022","unstructured":"Miret, J. J., Camps, V. J., Garc\u00eda, C., Caballero, M. T. & Gonzalez-Leal, J. M. Analysis and comparison of monofocal, extended depth of focus and trifocal intraocular lens profiles. Sci Rep 12, 8654 (2022).","journal-title":"Sci Rep"},{"key":"47102_CR25","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1097\/APO.0000000000000296","volume":"9","author":"P Kanclerz","year":"2020","unstructured":"Kanclerz, P., Toto, F., Grzybowski, A. & Alio, J. L. Extended depth-of-field intraocular lenses: An update. Asia Pac J Ophthalmol 9, 194\u2013202 (2020).","journal-title":"Asia Pac J Ophthalmol"},{"key":"47102_CR26","unstructured":"ISO 11979\u20132, Ophthalmic implants\u2014intraocular lenses. Part 2: optical properties and test methods. International Organization for Standardization (2014)."},{"key":"47102_CR27","doi-asserted-by":"publisher","first-page":"93960L","DOI":"10.1117\/12.2077755","volume":"9396","author":"JK Roland","year":"2015","unstructured":"Roland, J. K. A study of slanted-edge MTF stability and repeatability. Proc SPIE 9396, 93960L (2015).","journal-title":"Proc SPIE"},{"key":"47102_CR28","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1364\/JOSAA.420066","volume":"38","author":"B Chassagne","year":"2021","unstructured":"Chassagne, B. & Canioni, L. Individual design of aberration-free intraocular lenses. JOSA A 38, 683\u2013689 (2021).","journal-title":"JOSA A"},{"key":"47102_CR29","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1016\/j.survophthal.2018.08.003","volume":"64","author":"V Vargas","year":"2019","unstructured":"Vargas, V. et al. Methods for the study of near, intermediate vision, and accommodation: an overview of subjective and objective approaches. Surv Ophthalmol 64, 90\u2013100 (2019).","journal-title":"Surv Ophthalmol"},{"key":"47102_CR30","doi-asserted-by":"publisher","first-page":"2523","DOI":"10.3390\/jcm12072523","volume":"12","author":"G \u0141abuz","year":"2023","unstructured":"\u0141abuz, G., Yan, W., Baur, I. D., Khoramnia, R. & Auffarth, G. U. Comparison of five presbyopia-correcting intraocular lenses: Optical-bench assessment with visual-quality simulation. J Clin Med 12, 2523 (2023).","journal-title":"J Clin Med"},{"key":"47102_CR31","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1159\/000522510","volume":"65","author":"AF Borkenstein","year":"2022","unstructured":"Borkenstein, A. F., Borkenstein, E. M., Luedtke, H. & Schmid, R. Impact of decentration and tilt on spherical, aberration correcting, and specific aspherical intraocular lenses: An optical bench analysis. Ophthalmic Res 65, 425\u2013436 (2022).","journal-title":"Ophthalmic Res"},{"key":"47102_CR32","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0232546","volume":"15","author":"J P\u00e9rez-Gracia","year":"2020","unstructured":"P\u00e9rez-Gracia, J., Varea, A., Ares, J., Vall\u00e9s, J. A. & Rem\u00f3n, L. Evaluation of the optical performance for aspheric intraocular lenses in relation with tilt and decenter errors. PLoS One 15, e0232546 (2020).","journal-title":"PLoS One"},{"key":"47102_CR33","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1016\/j.jcrs.2018.10.045","volume":"45","author":"X Liu","year":"2019","unstructured":"Liu, X., Xie, L. & Huang, Y. Effects of decentration and tilt at different orientations on the optical performance of a rotationally asymmetric multifocal intraocular lens. J Cataract Refract Surg 45, 507\u2013514 (2019).","journal-title":"J Cataract Refract Surg"},{"key":"47102_CR34","doi-asserted-by":"publisher","first-page":"1657","DOI":"10.1016\/j.jcrs.2012.03.040","volume":"38","author":"R Mont\u00e9s-Mic\u00f3","year":"2012","unstructured":"Mont\u00e9s-Mic\u00f3, R., L\u00f3pez-Gil, N., P\u00e9rez-Vives, C., Bonaque, S. & Ferrer-Blasco, T. In vitro optical performance of nonrotational symmetric and refractive\u2013diffractive aspheric multifocal intraocular lenses: Impact of tilt and decentration. J Cataract Refract Surg 38, 1657\u20131663 (2012).","journal-title":"J Cataract Refract Surg"},{"key":"47102_CR35","doi-asserted-by":"publisher","first-page":"913","DOI":"10.1007\/s00417-021-05426-3","volume":"260","author":"D Tognetto","year":"2022","unstructured":"Tognetto, D. et al. Profile of a new extended range-of-vision IOL: A laboratory study. Graefes Arch Clin Exp Ophthalmol 260, 913\u2013916 (2022).","journal-title":"Graefes Arch Clin Exp Ophthalmol"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-47102-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-47102-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-47102-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,10]],"date-time":"2023-11-10T12:05:38Z","timestamp":1699617938000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-47102-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,10]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["47102"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-47102-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,10]]},"assertion":[{"value":"21 April 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 November 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 November 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Efe Can: employee of VSY Biotechnology, Esat Can Senel: employee of VSY Biotechnology, Sven TS Holmstr\u00f6m: employee of VSY Biotechnology, David P Pi\u00f1ero: no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"19646"}}