{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,19]],"date-time":"2026-09-19T16:38:22Z","timestamp":1789835902677,"version":"4.0.1"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,12,20]],"date-time":"2023-12-20T00:00:00Z","timestamp":1703030400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,12,20]],"date-time":"2023-12-20T00:00:00Z","timestamp":1703030400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"The Second Century Fund (C2F), Chulalongkorn University"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>A conventional 4-bar polycentric knee and solid ankle cushion heel foot (SACH foot) have been commonly used in developing countries. However, they cannot perform stance-phase knee flexion, which makes a person with an amputation walk unnaturally and with less stability. This research proposes a novel design of a 4-bar polycentric knee with stance-phase knee flexion ability (4BSF), which can perform both stance and swing-phase knee flexion, like able-bodied gait. In the proposed conceptual design, the instantaneous center of rotation (ICR) path is repositioned during the stance phase. The ICR was placed in front of the ground reaction force (GRF) to initiate knee flexion during the loading response. The prototype was validated by a single-subject pilot study at the Gait analysis laboratory. The results showed that a person with an amputation walks with stance-phase knee flexion using the proposed 4BSF. The maximum knee flexion angle is more than 10\u00b0 during the stance phase. Furthermore, when the 4BSF was used with a SACH foot, the amount of time to achieve the foot flat was shorter, and the foot flat duration time was twice as long as the conventional 4-bar polycentric knee.<\/jats:p>","DOI":"10.1038\/s41598-023-49879-4","type":"journal-article","created":{"date-parts":[[2023,12,21]],"date-time":"2023-12-21T08:02:21Z","timestamp":1703145741000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Development of four-bar polycentric knee joint with stance-phase knee flexion"],"prefix":"10.1038","volume":"13","author":[{"given":"Santiphap","family":"Phoengsongkhro","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pairat","family":"Tangpornprasert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pattarapol","family":"Yotnuengnit","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Manunchaya","family":"Samala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chanyaphan","family":"Virulsri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,12,20]]},"reference":[{"key":"49879_CR1","unstructured":"Organization, W. H. Global report on assistive technology (2022)."},{"key":"49879_CR2","unstructured":"Liao, C. et al. Product Narrative: Prostheses, AT2030 programme & ATscale Global Partnership for Assistive Technology. (2020)."},{"key":"49879_CR3","unstructured":"Organization, W. H. World report on disability 2011 (World Health Organization, 2011)."},{"key":"49879_CR4","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1177\/0309364613513824","volume":"39","author":"D Wyss","year":"2015","unstructured":"Wyss, D., Lindsay, S., Cleghorn, W. L. & Andrysek, J. Priorities in lower limb prosthetic service delivery based on an international survey of prosthetists in low-and high-income countries. Prosthet. Orthot. Int. 39, 102\u2013111 (2015).","journal-title":"Prosthet. Orthot. Int."},{"key":"49879_CR5","doi-asserted-by":"publisher","first-page":"1851","DOI":"10.1007\/s10439-013-0792-8","volume":"41","author":"SR Hamner","year":"2013","unstructured":"Hamner, S. R., Narayan, V. G. & Donaldson, K. M. Designing for scale: Development of the remotion knee for global emerging markets. Ann. Biomed. Eng. 41, 1851\u20131859 (2013).","journal-title":"Ann. Biomed. Eng."},{"key":"49879_CR6","doi-asserted-by":"publisher","first-page":"107","DOI":"10.3109\/03093648309166984","volume":"7","author":"K \u00d6berg","year":"1983","unstructured":"\u00d6berg, K. Knee mechanisms for through-knee prostheses. Prosthet. Orthot. Int. 7, 107\u2013112 (1983).","journal-title":"Prosthet. Orthot. Int."},{"key":"49879_CR7","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1109\/MPOT.2016.2614756","volume":"36","author":"PK Kumar","year":"2017","unstructured":"Kumar, P. K., Charan, M. & Kanagaraj, S. Trends and challenges in lower limb prosthesis. IEEE Potentials 36, 19\u201323 (2017).","journal-title":"IEEE Potentials"},{"key":"49879_CR8","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1177\/0309364611408495","volume":"35","author":"J Andrysek","year":"2011","unstructured":"Andrysek, J. et al. Mobility function of a prosthetic knee joint with an automatic stance phase lock. Prosthet. Orthot. Int. 35, 163\u2013170 (2011).","journal-title":"Prosthet. Orthot. Int."},{"key":"49879_CR9","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1109\/TNSRE.2005.856071","volume":"13","author":"J Andrysek","year":"2005","unstructured":"Andrysek, J., Naumann, S. & Cleghorn, W. L. Design and quantitative evaluation of a stance-phase controlled prosthetic knee joint for children. IEEE Trans. Neural Syst. Rehabil. Eng. 13, 437\u2013443 (2005).","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"49879_CR10","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1109\/TNSRE.2019.2952004","volume":"28","author":"CC Ngan","year":"2019","unstructured":"Ngan, C. C. & Andrysek, J. Modeling and design of the automatic stance phase lock (ASPL) knee joint control mechanism for paediatric users with transfemoral amputations. IEEE Trans. Neural Syst. Rehabil. Eng. 28, 203\u2013210 (2019).","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"49879_CR11","doi-asserted-by":"crossref","unstructured":"Arelekatti, V. M. & Winter, A. G. in 2015 IEEE International Conference on Rehabilitation Robotics (ICORR). 350\u2013356 (IEEE).","DOI":"10.1109\/ICORR.2015.7281224"},{"key":"49879_CR12","doi-asserted-by":"crossref","unstructured":"Murthy Arelekatti, V. & Winter, A. G. Design and preliminary field validation of a fully passive prosthetic knee mechanism for users with transfemoral amputation in India. J. Mech. Robot. 10 (2018).","DOI":"10.1115\/1.4039222"},{"key":"49879_CR13","doi-asserted-by":"publisher","first-page":"159","DOI":"10.3109\/03093649409164401","volume":"18","author":"C Radcliffe","year":"1994","unstructured":"Radcliffe, C. Four-bar linkage prosthetic knee mechanisms: Kinematics, alignment and prescription criteria. Prosthet. Orthot. Int. 18, 159\u2013173 (1994).","journal-title":"Prosthet. Orthot. Int."},{"key":"49879_CR14","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1177\/0309364616652017","volume":"41","author":"T Anand","year":"2017","unstructured":"Anand, T. & Sujatha, S. A method for performance comparison of polycentric knees and its application to the design of a knee for developing countries. Prosthet. Orthot. Int. 41, 402\u2013411 (2017).","journal-title":"Prosthet. Orthot. Int."},{"key":"49879_CR15","doi-asserted-by":"crossref","unstructured":"Johnson, L., De Asha, A. R., Munjal, R., Kulkarni, J. & Buckley, J. G. Toe clearance when walking in people with unilateral transtibial amputation: Effects of passive hydraulic ankle. (2014).","DOI":"10.1682\/JRRD.2013.05.0126"},{"key":"49879_CR16","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1109\/TNSRE.2012.2224885","volume":"21","author":"JW Sensinger","year":"2012","unstructured":"Sensinger, J. W., Intawachirarat, N. & Gard, S. A. Contribution of prosthetic knee and ankle mechanisms to swing-phase foot clearance. IEEE Trans. Neural Syst. Rehabil. Eng. 21, 74\u201380 (2012).","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"49879_CR17","doi-asserted-by":"crossref","unstructured":"Sudeesh, S., Sujatha, S. & Shunmugam, M. On the possibility of achieving near-normal swing phase of walking with passive single-axis and polycentric knees: a simulation approach. JPO J. Prosth. Orthot. 32, 121\u2013133 (2020).","DOI":"10.1097\/JPO.0000000000000251"},{"key":"49879_CR18","doi-asserted-by":"crossref","unstructured":"Blumentritt, S., Scherer, H. W., Wellershaus, U. & Michael, J. W. Design principles, biomechanical data and clinical experience with a polycentric knee offering controlled stance phase knee flexion: a preliminary report. JPO J. Prosth. Orthot. 9, 18\u201324 (1997).","DOI":"10.1097\/00008526-199710000-00005"},{"key":"49879_CR19","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1682\/JRRD.2003.01.0039","volume":"40","author":"D Jin","year":"2003","unstructured":"Jin, D., Zhang, R., Dimo, H., Wang, R. & Zhang, J. Kinematic and dynamic performance of prosthetic knee joint using six-bar mechanism. J. Rehabil. Res. Dev. 40, 39\u201348 (2003).","journal-title":"J. Rehabil. Res. Dev."},{"key":"49879_CR20","doi-asserted-by":"publisher","first-page":"28","DOI":"10.3390\/biomimetics6020028","volume":"6","author":"Y Zhang","year":"2021","unstructured":"Zhang, Y., Wang, E., Wang, M., Liu, S. & Ge, W. Design and experimental research of knee joint prosthesis based on gait acquisition technology. Biomimetics 6, 28 (2021).","journal-title":"Biomimetics"},{"key":"49879_CR21","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1186\/s12938-016-0284-9","volume":"15","author":"M Windrich","year":"2016","unstructured":"Windrich, M., Grimmer, M., Christ, O., Rinderknecht, S. & Beckerle, P. Active lower limb prosthetics: A systematic review of design issues and solutions. Biomed. Eng. Online 15, 5\u201319 (2016).","journal-title":"Biomed. Eng. Online"},{"key":"49879_CR22","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1016\/j.humov.2012.10.003","volume":"32","author":"C Hayot","year":"2013","unstructured":"Hayot, C., Sakka, S. & Lacouture, P. Contribution of the six major gait determinants on the vertical center of mass trajectory and the vertical ground reaction force. Hum. Movem. Sci. 32, 279\u2013289 (2013).","journal-title":"Hum. Movem. Sci."},{"key":"49879_CR23","unstructured":"Whittle, M. W. Gait analysis: an introduction. (Butterworth-Heinemann, 2014)."},{"key":"49879_CR24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4172\/2165-7025.1000380","volume":"8","author":"J Laferrier","year":"2018","unstructured":"Laferrier, J., Groff, A., Hale, S. & Sprunger, N. A review of commonly used prosthetic feet for developing countries: A call for research and development. J. Novel Physiother. 8, 1\u201310 (2018).","journal-title":"J. Novel Physiother."},{"key":"49879_CR25","doi-asserted-by":"crossref","unstructured":"Hafner, B. J. Clinical prescription and use of prosthetic foot and ankle mechanisms: a review of the literature. JPO J. Prosth. Orthotics 17, S5\u2013S11 (2005).","DOI":"10.1097\/00008526-200510001-00004"},{"key":"49879_CR26","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1080\/03093640408726694","volume":"28","author":"HVD Linde","year":"2004","unstructured":"Linde, H. V. D., Geertzen, J., Hofstad, C., Limbeek, J. V. & Postema, K. Prosthetic prescription in the Netherlands: An interview with clinical experts. Prosth. Orth. Int. 28, 98\u2013104 (2004).","journal-title":"Prosth. Orth. Int."},{"key":"49879_CR27","doi-asserted-by":"publisher","first-page":"839","DOI":"10.1682\/JRRD.2015.08.0148","volume":"53","author":"M Major","year":"2016","unstructured":"Major, M., Twiste, M., Kenney, L. & Howard, D. The effects of prosthetic ankle stiffness on stability of gait in people with trans-tibial amputation. J. Rehab. Res. Dev. 53, 839\u2013852 (2016).","journal-title":"J. Rehab. Res. Dev."},{"key":"49879_CR28","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/j.gaitpost.2010.08.009","volume":"33","author":"G Bovi","year":"2011","unstructured":"Bovi, G., Rabuffetti, M., Mazzoleni, P. & Ferrarin, M. A multiple-task gait analysis approach: Kinematic, kinetic and EMG reference data for healthy young and adult subjects. Gait Post. 33, 6\u201313 (2011).","journal-title":"Gait Post."},{"key":"49879_CR29","doi-asserted-by":"crossref","unstructured":"Narang, Y. S., Murthy Arelekatti, V. & Winter, A. G. The effects of the inertial properties of above-knee prostheses on optimal stiffness, damping, and engagement parameters of passive prosthetic knees. J. Biomech. Eng. 138 (2016).","DOI":"10.1115\/1.4034168"},{"key":"49879_CR30","doi-asserted-by":"publisher","first-page":"781","DOI":"10.1007\/s13246-020-00882-3","volume":"43","author":"RK Mohanty","year":"2020","unstructured":"Mohanty, R. K., Mohanty, R. & Sabut, S. K. A systematic review on design technology and application of polycentric prosthetic knee in amputee rehabilitation. Phys. Eng. Sci. Med. 43, 781\u2013798 (2020).","journal-title":"Phys. Eng. Sci. Med."},{"key":"49879_CR31","unstructured":"Winter, D. A. Biomechanics and motor control of human movement. (John Wiley & Sons, 1987)."},{"key":"49879_CR32","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1002\/cae.20532","volume":"22","author":"V Petuya","year":"2014","unstructured":"Petuya, V., Macho, E., Altuzarra, O., Pinto, C. & Hernandez, A. Educational software tools for the kinematic analysis of mechanisms. Comput. Appl. Eng. Educ. 22, 72\u201386 (2014).","journal-title":"Comput. Appl. Eng. Educ."},{"key":"49879_CR33","first-page":"137","volume":"232","author":"T Mangera","year":"2018","unstructured":"Mangera, T. et al. Optimal material selection for the construction of a paediatric prosthetic knee. Proc. Inst. Mech. Eng. Part L J. Mater. Des. Appl. 232, 137\u2013147 (2018).","journal-title":"Proc. Inst. Mech. Eng. Part L J. Mater. Des. Appl."},{"key":"49879_CR34","unstructured":"Standardization, I. O. f. Prosthetics: Structural Testing of Lower Limb Prostheses: Requirements and Test Methods. (International Organization for Standardization, 2016)."},{"key":"49879_CR35","unstructured":"Committee, A. S. M. I. H. (ASM International Materials Park, OH, Materials Park, OH, 1990)."},{"key":"49879_CR36","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41597-020-0494-7","volume":"7","author":"S Hood","year":"2020","unstructured":"Hood, S., Ishmael, M. K., Gunnell, A., Foreman, K. & Lenzi, T. A kinematic and kinetic dataset of 18 above-knee amputees walking at various speeds. Sci. Data 7, 1\u20138 (2020).","journal-title":"Sci. Data"},{"key":"49879_CR37","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.1109\/10.649988","volume":"44","author":"A Cappozzo","year":"1997","unstructured":"Cappozzo, A., Cappello, A., Croce, U. D. & Pensalfini, F. Surface-marker cluster design criteria for 3-D bone movement reconstruction. IEEE Trans. Biomed. Eng. 44, 1165\u20131174 (1997).","journal-title":"IEEE Trans. Biomed. Eng."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-49879-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-49879-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-49879-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,6]],"date-time":"2024-11-06T14:55:19Z","timestamp":1730904919000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-49879-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,20]]},"references-count":37,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["49879"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-49879-4","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,20]]},"assertion":[{"value":"13 January 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 December 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 December 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"22809"}}