{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T19:34:35Z","timestamp":1792697675458,"version":"4.5.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,12,27]],"date-time":"2023-12-27T00:00:00Z","timestamp":1703635200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,12,27]],"date-time":"2023-12-27T00:00:00Z","timestamp":1703635200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>\n                    This study aimed to evaluate the effect of the number of uses and autoclave sterilization on the cyclic fatigue resistance of four replica-like instruments RC Blue; Only One File Blue; Recip One Blue; and Micro Blue compared to the original\u00a0system Reciproc Blue (VDW, Munich, Germany). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). Fifty molars were instrumented by ten instruments (n=10). After sterilization in an autoclave, the \u00a0instruments were analyzed by SEM. This procedure was repeated twice more using different molars, totaling 3 rounds of instrumentation, sterilization and SEM analysis. Then, ten different instruments from each brand were tested for cyclic fatigue resistance. Number of uses data were analyzed using Chi-squared analysis, and cyclic fatigue data were analyzed by one-way Anova followed by Tukey\u2019s test as the data had normal distribution. The fracture times for all systems had no significant difference, but Micro Blue had significantly lower values than the other systems (\n                    <jats:italic>p<\/jats:italic>\n                    \u2009&lt;\u20090.05). The SEM analysis showed distortions in the instruments after the 3rd use. Therefore, all tested instruments except of Micro Blue have similar resistance to cyclic fatigue, and all are reliable for use in up to 2-cases.\n                  <\/jats:p>","DOI":"10.1038\/s41598-023-50096-2","type":"journal-article","created":{"date-parts":[[2023,12,27]],"date-time":"2023-12-27T06:02:21Z","timestamp":1703656941000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["Assessing the cyclic fatigue resistance and sterilization effects on replica-like endodontic instruments compared to Reciproc Blue"],"prefix":"10.1038","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0009-0008-3135-3067","authenticated-orcid":false,"given":"Fernando Antonio Siano","family":"dos Reis","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1112-985X","authenticated-orcid":false,"given":"Amjad","family":"Abu Hasna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-4012-2829","authenticated-orcid":false,"given":"Gustavo","family":"Ragozzini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felipe Bernardo","family":"de Moura","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tiago Moreira Bastos","family":"Campos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3320-9172","authenticated-orcid":false,"given":"Alexandre Sigrist","family":"de Martin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0987-5594","authenticated-orcid":false,"given":"Cl\u00e1udio Antonio Talge","family":"Carvalho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2675-0884","authenticated-orcid":false,"given":"Carlos Eduardo Silveira","family":"Bueno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,12,27]]},"reference":[{"key":"50096_CR1","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1016\/S0011-8532(22)00677-2","volume":"18","author":"H Schilder","year":"1974","unstructured":"Schilder, H. Cleaning and shaping the root canal. Dent. Clin. North Am. 18, 269\u2013296 (1974).","journal-title":"Dent. Clin. North Am."},{"key":"50096_CR2","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1111\/j.1365-2591.2011.01957.x","volume":"45","author":"JL Gutmann","year":"2012","unstructured":"Gutmann, J. L. & Gao, Y. Alteration in the inherent metallic and surface properties of nickel-titanium root canal instruments to enhance performance, durability and safety: A focused review. Int. Endod. J. 45, 113\u2013128 (2012).","journal-title":"Int. Endod. J."},{"key":"50096_CR3","doi-asserted-by":"publisher","first-page":"1623","DOI":"10.1111\/iej.13529","volume":"54","author":"JNR Martins","year":"2021","unstructured":"Martins, J. N. R. et al. Design, metallurgical features, mechanical performance and canal preparation of six reciprocating instruments. Int. Endod. J. 54, 1623\u20131637 (2021).","journal-title":"Int. Endod. J."},{"key":"50096_CR4","doi-asserted-by":"publisher","first-page":"1485","DOI":"10.1016\/j.joen.2020.07.016","volume":"46","author":"EJNL Silva","year":"2020","unstructured":"Silva, E. J. N. L. et al. Mechanical tests, metallurgical characterization, and shaping ability of nickel-titanium rotary instruments: A multimethod research. J. Endod. 46, 1485\u20131494 (2020).","journal-title":"J. Endod."},{"key":"50096_CR5","doi-asserted-by":"publisher","first-page":"26","DOI":"10.4103\/jcd.jcd_611_21","volume":"26","author":"AH Al-Amidi","year":"2023","unstructured":"Al-Amidi, A. H. & Al-Gharrawi, H.A.-R. Effect of autoclave sterilization on the cyclic fatigue resistance of EdgeFile X7, 2Shape, and F-one nickel-titanium endodontic instruments. J. Conserv. Dent. 26, 26\u201330 (2023).","journal-title":"J. Conserv. Dent."},{"key":"50096_CR6","doi-asserted-by":"publisher","first-page":"364","DOI":"10.4103\/JCD.JCD_409_20","volume":"23","author":"CH Ribeiro Camargo","year":"2020","unstructured":"Ribeiro Camargo, C. H. et al. Cyclic fatigue, torsional failure, and flexural resistance of rotary and reciprocating instruments. J. Conserv. Dent. 23, 364\u2013369 (2020).","journal-title":"J. Conserv. Dent."},{"key":"50096_CR7","doi-asserted-by":"publisher","first-page":"85","DOI":"10.5395\/rde.2015.40.1.85","volume":"40","author":"G Yared","year":"2015","unstructured":"Yared, G. Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: Preliminary observations. Restor. Dent. Endod. 40, 85\u201390 (2015).","journal-title":"Restor. Dent. Endod."},{"key":"50096_CR8","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1111\/j.1365-2591.2007.01351.x","volume":"41","author":"G Yared","year":"2008","unstructured":"Yared, G. Canal preparation using only one Ni-Ti rotary instrument: Preliminary observations. Int. Endod. J. 41, 339\u2013344 (2008).","journal-title":"Int. Endod. J."},{"key":"50096_CR9","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.1111\/iej.12412","volume":"48","author":"MFV Marceliano-Alves","year":"2015","unstructured":"Marceliano-Alves, M. F. V. et al. Shaping ability of single-file reciprocating and heat-treated multifile rotary systems: A micro-CT study. Int. Endod. J. 48, 1129\u20131136 (2015).","journal-title":"Int. Endod. J."},{"key":"50096_CR10","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1016\/j.pmatsci.2004.10.001","volume":"50","author":"K Otsuka","year":"2005","unstructured":"Otsuka, K. & Ren, X. Physical metallurgy of Ti\u2013Ni-based shape memory alloys. Prog. Mater. Sci. 50, 511\u2013678 (2005).","journal-title":"Prog. Mater. Sci."},{"key":"50096_CR11","doi-asserted-by":"publisher","first-page":"e20200044","DOI":"10.1590\/1981-86372020000443683","volume":"68","author":"BC de Almeida","year":"2020","unstructured":"de Almeida, B. C. & Elias, C. N. Influence of heat treatment on color and flexibility of nickel-titanium endodontic instruments. RGO Rev. Ga\u00fach. Odontol. 68, e20200044 (2020).","journal-title":"RGO Rev. Ga\u00fach. Odontol."},{"key":"50096_CR12","first-page":"91","volume":"22","author":"W-S Chan","year":"2023","unstructured":"Chan, W.-S., Gulati, K. & Peters, O. A. Advancing Nitinol: From heat treatment to surface functionalization for nickel-titanium (NiTi) instruments in endodontics. Bioact. Mater. 22, 91\u2013111 (2023).","journal-title":"Bioact. Mater."},{"key":"50096_CR13","doi-asserted-by":"publisher","first-page":"e67","DOI":"10.1590\/1807-3107bor-2018.vol32.0067","volume":"32","author":"G Gavini","year":"2018","unstructured":"Gavini, G. et al. Nickel-titanium instruments in endodontics: A concise review of the state of the art. Braz. Oral Res. 32, e67 (2018).","journal-title":"Braz. Oral Res."},{"key":"50096_CR14","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1016\/j.joen.2012.02.017","volume":"38","author":"S B\u00fcrklein","year":"2012","unstructured":"B\u00fcrklein, S. & Sch\u00e4fer, E. Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems. J. Endod. 38, 850\u2013852 (2012).","journal-title":"J. Endod."},{"key":"50096_CR15","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1016\/j.joen.2016.10.039","volume":"43","author":"G De-Deus","year":"2017","unstructured":"De-Deus, G. et al. Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the reciproc files. J. Endod. 43, 462\u2013466 (2017).","journal-title":"J. Endod."},{"key":"50096_CR16","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1111\/aej.12639","volume":"49","author":"O Uslu","year":"2023","unstructured":"Uslu, O., Haznedaroglu, F. & Keskin, C. Comparison of mechanical resistance and standardisation between original brand and replica-like endodontic systems. Aust. Endod. J. 49, 149\u2013158 (2023).","journal-title":"Aust. Endod. J."},{"key":"50096_CR17","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1016\/j.joen.2016.01.025","volume":"42","author":"RA de Vasconcelos","year":"2016","unstructured":"de Vasconcelos, R. A. et al. Evidence for reduced fatigue resistance of contemporary rotary instruments exposed to body temperature. J. Endod. 42, 782\u2013787 (2016).","journal-title":"J. Endod."},{"key":"50096_CR18","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1016\/S0099-2399(97)80250-6","volume":"23","author":"JP Pruett","year":"1997","unstructured":"Pruett, J. P., Clement, D. J. & Carnes, D. L. Cyclic fatigue testing of nickel-titanium endodontic instruments. J. Endod. 23, 77\u201385 (1997).","journal-title":"J. Endod."},{"key":"50096_CR19","doi-asserted-by":"publisher","first-page":"1884","DOI":"10.1016\/j.joen.2020.08.021","volume":"46","author":"JNR Martins","year":"2020","unstructured":"Martins, J. N. R. et al. Mechanical performance and metallurgical features of protaper universal and 6 replicalike systems. J. Endod. 46, 1884\u20131893 (2020).","journal-title":"J. Endod."},{"key":"50096_CR20","doi-asserted-by":"publisher","first-page":"1136","DOI":"10.1016\/j.joen.2020.05.001","volume":"46","author":"JNR Martins","year":"2020","unstructured":"Martins, J. N. R. et al. Influence of kinematics on the cyclic fatigue resistance of replicalike and original brand rotary instruments. J. Endod. 46, 1136\u20131143 (2020).","journal-title":"J. Endod."},{"key":"50096_CR21","doi-asserted-by":"publisher","first-page":"2633","DOI":"10.1007\/s00784-018-2362-9","volume":"22","author":"EJNL Silva","year":"2018","unstructured":"Silva, E. J. N. L. et al. Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments. Clin. Oral Investig. 22, 2633\u20132638 (2018).","journal-title":"Clin. Oral Investig."},{"key":"50096_CR22","doi-asserted-by":"publisher","first-page":"e106","DOI":"10.1016\/j.tripleo.2005.12.012","volume":"102","author":"TR Tripi","year":"2006","unstructured":"Tripi, T. R., Bonaccorso, A. & Condorelli, G. G. Cyclic fatigue of different nickel-titanium endodontic rotary instruments. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod. 102, e106\u2013e114 (2006).","journal-title":"Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod."},{"key":"50096_CR23","doi-asserted-by":"publisher","first-page":"1427","DOI":"10.1111\/iej.13182","volume":"52","author":"M H\u00fclsmann","year":"2019","unstructured":"H\u00fclsmann, M., Donnermeyer, D. & Sch\u00e4fer, E. A critical appraisal of studies on cyclic fatigue resistance of engine-driven endodontic instruments. Int. Endod. J. 52, 1427\u20131445 (2019).","journal-title":"Int. Endod. J."},{"key":"50096_CR24","doi-asserted-by":"publisher","first-page":"1469","DOI":"10.1016\/j.joen.2009.06.015","volume":"35","author":"G Plotino","year":"2009","unstructured":"Plotino, G., Grande, N. M., Cordaro, M., Testarelli, L. & Gambarini, G. A review of cyclic fatigue testing of nickel-titanium rotary instruments. J. Endod. 35, 1469\u20131476 (2009).","journal-title":"J. Endod."},{"key":"50096_CR25","doi-asserted-by":"publisher","first-page":"880","DOI":"10.1111\/iej.13073","volume":"52","author":"A Kele\u015f","year":"2019","unstructured":"Kele\u015f, A., Eymirli, A., Uyan\u0131k, O. & Nagas, E. Influence of static and dynamic cyclic fatigue tests on the lifespan of four reciprocating systems at different temperatures. Int. Endod. J. 52, 880\u2013886 (2019).","journal-title":"Int. Endod. J."},{"key":"50096_CR26","doi-asserted-by":"publisher","first-page":"1847","DOI":"10.1016\/j.joen.2017.06.033","volume":"43","author":"X Huang","year":"2017","unstructured":"Huang, X., Shen, Y., Wei, X. & Haapasalo, M. Fatigue resistance of nickel-titanium instruments exposed to high-concentration hypochlorite. J. Endod. 43, 1847\u20131851 (2017).","journal-title":"J. Endod."},{"key":"50096_CR27","doi-asserted-by":"publisher","first-page":"297","DOI":"10.1046\/j.1365-2591.2000.00339.x","volume":"33","author":"SA Thompson","year":"2000","unstructured":"Thompson, S. A. An overview of nickel-titanium alloys used in dentistry. Int. Endod. J. 33, 297\u2013310 (2000).","journal-title":"Int. Endod. J."},{"key":"50096_CR28","doi-asserted-by":"publisher","first-page":"684","DOI":"10.1016\/j.joen.2011.12.033","volume":"38","author":"G Gavini","year":"2012","unstructured":"Gavini, G., Caldeira, C. L., Akisue, E., de Miranda Candeiro, G. T. & Kawakami, D. A. Resistance to flexural fatigue of Reciproc R25 files under continuous rotation and reciprocating movement. J. Endod. 38, 684\u2013687 (2012).","journal-title":"J. Endod."},{"key":"50096_CR29","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1002\/sca.21150","volume":"36","author":"C Pirani","year":"2014","unstructured":"Pirani, C. et al. Wear and metallographic analysis of WaveOne and reciproc NiTi instruments before and after three uses in root canals. Scanning 36, 517\u2013525 (2014).","journal-title":"Scanning"},{"key":"50096_CR30","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1016\/j.joen.2016.12.024","volume":"43","author":"CSP Bueno","year":"2017","unstructured":"Bueno, C. S. P. et al. Fracture incidence of WaveOne and Reciproc files during root canal preparation of up to 3 posterior teeth: A prospective clinical study. J. Endod. 43, 705\u2013708 (2017).","journal-title":"J. Endod."},{"key":"50096_CR31","doi-asserted-by":"publisher","first-page":"1148","DOI":"10.1111\/j.1365-2591.2012.02088.x","volume":"45","author":"G Spagnuolo","year":"2012","unstructured":"Spagnuolo, G. et al. Effect of autoclaving on the surfaces of TiN -coated and conventional nickel-titanium rotary instruments. Int. Endod. J. 45, 1148\u20131155 (2012).","journal-title":"Int. Endod. J."},{"key":"50096_CR32","doi-asserted-by":"publisher","first-page":"770","DOI":"10.1111\/j.1365-2591.2006.01147.x","volume":"39","author":"G Alexandrou","year":"2006","unstructured":"Alexandrou, G., Chrissafis, K., Vasiliadis, L., Pavlidou, E. & Polychroniadis, E. K. Effect of heat sterilization on surface characteristics and microstructure of Mani NRT rotary nickel-titanium instruments. Int. Endod. J. 39, 770\u2013778 (2006).","journal-title":"Int. Endod. J."},{"key":"50096_CR33","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1186\/s12903-020-01233-0","volume":"20","author":"K Van Pham","year":"2020","unstructured":"Van Pham, K. & Vo, C. Q. A new method for assessment of nickel-titanium endodontic instrument surface roughness using field emission scanning electronic microscope. BMC Oral Health 20, 240 (2020).","journal-title":"BMC Oral Health"},{"key":"50096_CR34","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1111\/iej.13960","volume":"56","author":"EJNL Silva","year":"2023","unstructured":"Silva, E. J. N. L. et al. To flat or not to flat? Exploring the impact of flat-side design on rotary instruments using a comprehensive multimethod investigation. Int. Endod. J. 56, 1301\u20131315 (2023).","journal-title":"Int. Endod. J."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-50096-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-50096-2","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-50096-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,12,27]],"date-time":"2023-12-27T06:04:44Z","timestamp":1703657084000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-50096-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12,27]]},"references-count":34,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["50096"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-50096-2","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,12,27]]},"assertion":[{"value":"24 August 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 December 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 December 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Author Fernando dos Reis is a speaker of Perfect in Brazil, Author Carlos Eduardo Silveira Bueno is a speaker of Dentsply\/VDW in Brazil. The other authors declare that they have no conflicts of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"22956"}}