{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,14]],"date-time":"2026-11-14T19:49:49Z","timestamp":1794685789706,"version":"4.9.1"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,1,4]],"date-time":"2024-01-04T00:00:00Z","timestamp":1704326400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,1,4]],"date-time":"2024-01-04T00:00:00Z","timestamp":1704326400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Bonn"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Aim of this study was to assess the impact of virtual monoenergetic images (VMI) on dental implant artifacts in photon-counting detector computed tomography (PCD-CT) compared to standard reconstructed polychromatic images (PI). 30 scans with extensive (\u2265\u20095 dental implants) dental implant-associated artifacts were retrospectively analyzed. Scans were acquired during clinical routine on a PCD-CT. VMI were reconstructed for 100\u2013190\u00a0keV (10\u00a0keV steps) and compared to PI. Artifact extent and assessment of adjacent soft tissue were rated using a 5-point Likert grading scale for qualitative assessment. Quantitative assessment was performed using ROIs in most pronounced hypodense and hyperdense artifacts, artifact-impaired soft tissue, artifact-free fat and muscle tissue. A corrected attenuation was calculated as difference between artifact-impaired tissue and tissue without artifacts. Qualitative assessment of soft palate and cheeks improved for all VMI compared to PI (Median PI: 1 (Range: 1\u20133) and 1 (1\u20133); e.g. VMI<jats:sub>130\u00a0keV<\/jats:sub> 2 (1\u20135); <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.0001 and 2 (1\u20134); <jats:italic>p<\/jats:italic>\u2009&lt;\u20090.0001). In quantitative assessment, VMI<jats:sub>130\u00a0keV<\/jats:sub> showed best results with a corrected attenuation closest to 0 (PI: 30.48\u2009\u00b1\u200998.16; VMI<jats:sub>130\u00a0keV<\/jats:sub>: \u2212\u20090.55\u2009\u00b1\u200973.38; <jats:italic>p<\/jats:italic>\u2009=\u20090.0026). Overall, photon-counting deducted VMI reduce the extent of dental implant-associated artifacts. VMI of 130\u00a0keV showed best results and are recommended to support head and neck CT scans.<\/jats:p>","DOI":"10.1038\/s41598-023-50926-3","type":"journal-article","created":{"date-parts":[[2024,1,4]],"date-time":"2024-01-04T10:02:08Z","timestamp":1704362528000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Use of virtual monoenergetic images for reduction of extensive dental implant associated artifacts in photon-counting detector CT"],"prefix":"10.1038","volume":"14","author":[{"given":"Yannik C.","family":"Layer","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Narine","family":"Mesropyan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick A.","family":"Kupczyk","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julian A.","family":"Luetkens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Isaak","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tatjana","family":"Dell","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin P.","family":"Ernst","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulrike I.","family":"Attenberger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Kuetting","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,1,4]]},"reference":[{"key":"50926_CR1","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1007\/s10140-018-01663-y","volume":"26","author":"JT Brandfass","year":"2019","unstructured":"Brandfass, J. T., Ulano, A. C., Nickerson, J. P. & Bazylewicz, M. P. Dental caries on CT in the ER population: Prevalence and reporting practices. Emerg. Radiol. 26, 263\u2013267 (2019).","journal-title":"Emerg. Radiol."},{"key":"50926_CR2","doi-asserted-by":"publisher","first-page":"4228","DOI":"10.1007\/s00330-018-5928-7","volume":"29","author":"KR Laukamp","year":"2019","unstructured":"Laukamp, K. R. et al. Metal artifacts in patients with large dental implants and bridges: Combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts. Eur. Radiol. 29, 4228\u20134238 (2019).","journal-title":"Eur. Radiol."},{"key":"50926_CR3","doi-asserted-by":"publisher","first-page":"1679","DOI":"10.1148\/rg.246045065","volume":"24","author":"JF Barrett","year":"2004","unstructured":"Barrett, J. F. & Keat, N. Artifacts in CT: Recognition and avoidance. Radiographics 24, 1679\u20131691 (2004).","journal-title":"Radiographics"},{"key":"50926_CR4","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1007\/s00234-015-1537-1","volume":"57","author":"A de Crop","year":"2015","unstructured":"de Crop, A. et al. Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software\u2014Does it make a difference?. Neuroradiology 57, 841\u2013849 (2015).","journal-title":"Neuroradiology"},{"key":"50926_CR5","doi-asserted-by":"publisher","first-page":"716","DOI":"10.2214\/AJR.21.26772","volume":"218","author":"AMA Schmidt","year":"2022","unstructured":"Schmidt, A. M. A. et al. Combination of iterative metal artifact reduction and virtual monoenergetic reconstruction using split-filter dual-energy CT in patients with dental artifact on head and neck CT. AJR Am. J. Roentgenol. 218, 716\u2013727 (2022).","journal-title":"AJR Am. J. Roentgenol."},{"key":"50926_CR6","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/s13244-020-0836-1","volume":"11","author":"Y Wei","year":"2020","unstructured":"Wei, Y. et al. Clinical application of multi-material artifact reduction (MMAR) technique in Revolution CT to reduce metallic dental artifacts. Insights Imaging 11, 32 (2020).","journal-title":"Insights Imaging"},{"key":"50926_CR7","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.ejrad.2018.04.018","volume":"104","author":"N Gro\u00dfe Hokamp","year":"2018","unstructured":"Gro\u00dfe Hokamp, N. et al. Artifact reduction from dental implants using virtual monoenergetic reconstructions from novel spectral detector CT. Eur. J. Radiol. 104, 136\u2013142 (2018).","journal-title":"Eur. J. Radiol."},{"key":"50926_CR8","doi-asserted-by":"publisher","first-page":"20180546","DOI":"10.1259\/bjr.20180546","volume":"92","author":"T D'Angelo","year":"2019","unstructured":"D\u2019Angelo, T. et al. Dual energy computed tomography virtual monoenergetic imaging: Technique and clinical applications. Br. J. Radiol. 92, 20180546 (2019).","journal-title":"Br. J. Radiol."},{"key":"50926_CR9","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1148\/radiol.213203","volume":"303","author":"MJ Willemink","year":"2022","unstructured":"Willemink, M. J. & Grist, T. M. Counting photons: The next era for CT imaging?. Radiology 303, 139\u2013140 (2022).","journal-title":"Radiology"},{"key":"50926_CR10","doi-asserted-by":"publisher","first-page":"110442","DOI":"10.1016\/j.ejrad.2022.110442","volume":"154","author":"N K\u00e4mmerling","year":"2022","unstructured":"K\u00e4mmerling, N., Sandstedt, M., Farnebo, S., Persson, A. & Tesselaar, E. Assessment of image quality in photon-counting detector computed tomography of the wrist\u2014An ex vivo study. Eur. J. Radiol. 154, 110442 (2022).","journal-title":"Eur. J. Radiol."},{"key":"50926_CR11","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1007\/s00256-022-04117-2","volume":"52","author":"K Rajendran","year":"2023","unstructured":"Rajendran, K. et al. Improved visualization of the wrist at lower radiation dose with photon-counting-detector CT. Skelet. Radiol. 52, 23\u201329 (2023).","journal-title":"Skelet. Radiol."},{"key":"50926_CR12","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1097\/RLI.0000000000000901","volume":"57","author":"J-P Grunz","year":"2022","unstructured":"Grunz, J.-P. et al. Spectral shaping via tin prefiltration in ultra-high-resolution photon-counting and energy-integrating detector CT of the temporal bone. Investig. Radiol. 57, 819\u2013825 (2022).","journal-title":"Investig. Radiol."},{"key":"50926_CR13","doi-asserted-by":"publisher","DOI":"10.1016\/j.acra.2022.05.021","author":"R Wrazidlo","year":"2022","unstructured":"Wrazidlo, R. et al. Radiation dose reduction in contrast-enhanced abdominal CT: Comparison of photon-counting detector CT with 2nd generation dual-source dual-energy CT in an oncologic cohort. Acad. Radiol. https:\/\/doi.org\/10.1016\/j.acra.2022.05.021 (2022).","journal-title":"Acad. Radiol."},{"key":"50926_CR14","doi-asserted-by":"publisher","first-page":"1441","DOI":"10.3390\/diagnostics12061441","volume":"12","author":"MM Woeltjen","year":"2022","unstructured":"Woeltjen, M. M. et al. Low-dose high-resolution photon-counting CT of the lung: Radiation dose and image quality in the clinical routine. Diagnostics 12, 1441 (2022).","journal-title":"Diagnostics"},{"key":"50926_CR15","doi-asserted-by":"crossref","unstructured":"Hagen, F. et al. Image Quality and Radiation Dose of Contrast-Enhanced Chest-CT Acquired on a Clinical Photon-Counting Detector CT vs. Second-Generation Dual-Source CT in an Oncologic Cohort: Preliminary Results. Tomography (Ann Arbor, Mich.) 8, 1466\u20131476 (2022).","DOI":"10.3390\/tomography8030119"},{"key":"50926_CR16","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1097\/RLI.0000000000000887","volume":"57","author":"J-P Grunz","year":"2022","unstructured":"Grunz, J.-P. et al. Ultra-Low-Dose Photon-Counting CT Imaging of the Paranasal Sinus With Tin Prefiltration: How Low Can We Go?. Investigative radiology 57, 728\u2013733 (2022).","journal-title":"Investigative radiology"},{"key":"50926_CR17","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1109\/TRPMS.2020.3020212","volume":"5","author":"SS Hsieh","year":"2021","unstructured":"Hsieh, S. S., Leng, S., Rajendran, K., Tao, S. & McCollough, C. H. Photon Counting CT: Clinical Applications and Future Developments. IEEE transactions on radiation and plasma medical sciences 5, 441\u2013452 (2021).","journal-title":"IEEE transactions on radiation and plasma medical sciences"},{"key":"50926_CR18","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1097\/RLI.0000000000000535","volume":"54","author":"W Zhou","year":"2019","unstructured":"Zhou, W. et al. Reduction of metal artifacts and improvement in dose efficiency using photon-counting detector computed tomography and tin filtration. Investig. Radiol. 54, 204\u2013211 (2019).","journal-title":"Investig. Radiol."},{"key":"50926_CR19","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/j.jcm.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo, T. K. & Li, M. Y. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J. Chiropr. Med. 15, 155\u2013163 (2016).","journal-title":"J. Chiropr. Med."},{"key":"50926_CR20","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1148\/rg.273065087","volume":"27","author":"M-J Lee","year":"2007","unstructured":"Lee, M.-J. et al. Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT. Radiographics 27, 791\u2013803 (2007).","journal-title":"Radiographics"},{"key":"50926_CR21","doi-asserted-by":"publisher","first-page":"2064","DOI":"10.1148\/rg.2016160079","volume":"36","author":"K Kalisz","year":"2016","unstructured":"Kalisz, K. et al. Artifacts at cardiac CT: Physics and solutions. Radiographics 36, 2064\u20132083 (2016).","journal-title":"Radiographics"},{"key":"50926_CR22","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1148\/radiographics.18.2.9536489","volume":"18","author":"JT Bushberg","year":"1998","unstructured":"Bushberg, J. T. The AAPM\/RSNA physics tutorial for residents. X-ray interactions. Radiographics 18, 457\u2013468 (1998).","journal-title":"Radiographics"},{"key":"50926_CR23","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1007\/s12194-012-0179-9","volume":"6","author":"I Mori","year":"2013","unstructured":"Mori, I., Machida, Y., Osanai, M. & Iinuma, K. Photon starvation artifacts of X-ray CT: Their true cause and a solution. Radiol. Phys. Technol. 6, 130\u2013141 (2013).","journal-title":"Radiol. Phys. Technol."},{"key":"50926_CR24","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1148\/rg.332125124","volume":"33","author":"E Pessis","year":"2013","unstructured":"Pessis, E. et al. Virtual monochromatic spectral imaging with fast kilovoltage switching: reduction of metal artifacts at CT. Radiographics 33, 573\u2013583 (2013).","journal-title":"Radiographics"},{"key":"50926_CR25","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1016\/j.acra.2021.06.018","volume":"29","author":"K Higashigaito","year":"2022","unstructured":"Higashigaito, K. et al. Contrast-enhanced abdominal CT with clinical photon-counting detector CT: Assessment of image quality and comparison with energy-integrating detector CT. Acad. Radiol. 29, 689\u2013697 (2022).","journal-title":"Acad. Radiol."},{"key":"50926_CR26","doi-asserted-by":"publisher","first-page":"110325","DOI":"10.1016\/j.ejrad.2022.110325","volume":"151","author":"F Hagen","year":"2022","unstructured":"Hagen, F. et al. Image quality and dose exposure of contrast-enhanced abdominal CT on a 1st generation clinical dual-source photon-counting detector CT in obese patients vs. a 2nd generation dual-source dual energy integrating detector CT. Eur. J. Radiol. 151, 110325 (2022).","journal-title":"Eur. J. Radiol."},{"key":"50926_CR27","doi-asserted-by":"publisher","first-page":"110514","DOI":"10.1016\/j.ejrad.2022.110514","volume":"156","author":"D Graafen","year":"2022","unstructured":"Graafen, D. et al. Photon-counting detector CT improves quality of arterial phase abdominal scans: A head-to-head comparison with energy-integrating CT. Eur. J. Radiol. 156, 110514 (2022).","journal-title":"Eur. J. Radiol."},{"key":"50926_CR28","doi-asserted-by":"publisher","first-page":"318","DOI":"10.1148\/radiol.12111604","volume":"266","author":"SR Pomerantz","year":"2013","unstructured":"Pomerantz, S. R. et al. Virtual monochromatic reconstruction of dual-energy unenhanced head CT at 65\u201375 keV maximizes image quality compared with conventional polychromatic CT. Radiology 266, 318\u2013325 (2013).","journal-title":"Radiology"},{"key":"50926_CR29","doi-asserted-by":"publisher","first-page":"424","DOI":"10.1097\/RLI.0000000000000460","volume":"53","author":"N Gro\u00dfe Hokamp","year":"2018","unstructured":"Gro\u00dfe Hokamp, N. et al. Reduction of artifacts caused by deep brain stimulating electrodes in cranial computed tomography imaging by means of virtual monoenergetic images, metal artifact reduction algorithms, and their combination. Investig. Radiol. 53, 424\u2013431 (2018).","journal-title":"Investig. Radiol."},{"key":"50926_CR30","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1007\/s12024-013-9420-z","volume":"9","author":"P Stolzmann","year":"2013","unstructured":"Stolzmann, P. et al. Monoenergetic computed tomography reconstructions reduce beam hardening artifacts from dental restorations. Forensic Sci. Med. Pathol. 9, 327\u2013332 (2013).","journal-title":"Forensic Sci. Med. Pathol."},{"key":"50926_CR31","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s40134-017-0213-0","volume":"5","author":"ED Roele","year":"2017","unstructured":"Roele, E. D., Timmer, V. C. M. L., Vaassen, L. A. A., van Kroonenburgh, A. M. J. L. & Postma, A. A. Dual-energy CT in head and neck imaging. Curr. Radiol. Rep. 5, 19 (2017).","journal-title":"Curr. Radiol. Rep."},{"key":"50926_CR32","doi-asserted-by":"publisher","first-page":"1424","DOI":"10.1007\/s00330-011-2062-1","volume":"21","author":"F Bamberg","year":"2011","unstructured":"Bamberg, F. et al. Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation. Eur. Radiol. 21, 1424\u20131429 (2011).","journal-title":"Eur. Radiol."},{"key":"50926_CR33","doi-asserted-by":"publisher","first-page":"2357","DOI":"10.1007\/s00330-012-2501-7","volume":"22","author":"R Guggenberger","year":"2012","unstructured":"Guggenberger, R. et al. Metallic artefact reduction with monoenergetic dual-energy CT: Systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels. Eur. Radiol. 22, 2357\u20132364 (2012).","journal-title":"Eur. Radiol."},{"key":"50926_CR34","doi-asserted-by":"publisher","first-page":"W352","DOI":"10.2214\/AJR.14.12547","volume":"205","author":"HS Takrouri","year":"2015","unstructured":"Takrouri, H. S. et al. Metal artifact reduction: Added value of rapid-kilovoltage-switching dual-energy CT in relation to single-energy CT in a piglet animal model. Am. J. Roentgenol. 205, W352\u2013W359 (2015).","journal-title":"Am. J. Roentgenol."},{"key":"50926_CR35","doi-asserted-by":"publisher","first-page":"e360","DOI":"10.1016\/j.ejrad.2013.02.024","volume":"82","author":"Y Wang","year":"2013","unstructured":"Wang, Y. et al. Metal artifacts reduction using monochromatic images from spectral CT: Evaluation of pedicle screws in patients with scoliosis. Eur. J. Radiol. 82, e360\u2013e366 (2013).","journal-title":"Eur. J. Radiol."},{"key":"50926_CR36","doi-asserted-by":"publisher","first-page":"1252","DOI":"10.1016\/j.acra.2011.05.009","volume":"18","author":"C Zhou","year":"2011","unstructured":"Zhou, C. et al. Monoenergetic imaging of dual-energy CT reduces artifacts from implanted metal orthopedic devices in patients with factures. Acad. Radiol. 18, 1252\u20131257 (2011).","journal-title":"Acad. Radiol."},{"key":"50926_CR37","doi-asserted-by":"publisher","first-page":"115018","DOI":"10.1088\/1361-6560\/ac71f0","volume":"67","author":"A Julian","year":"2022","unstructured":"Julian, A. et al. Iterative metal artifact reduction on a clinical photon counting system\u2014technical possibilities and reconstruction selection for optimal results dependent on the metal scenario. Phys. Med. Biol 67, 115018 (2022).","journal-title":"Phys. Med. Biol"},{"key":"50926_CR38","doi-asserted-by":"publisher","first-page":"1642","DOI":"10.3390\/tomography8040136","volume":"8","author":"S Waldeck","year":"2022","unstructured":"Waldeck, S. et al. Photon-counting detector CT virtual monoengergetic images for cochlear implant visualization-A head to head comparison to energy-integrating detector CT. Tomography 8, 1642\u20131648 (2022).","journal-title":"Tomography"},{"key":"50926_CR39","doi-asserted-by":"publisher","first-page":"e31766","DOI":"10.1371\/journal.pone.0031766","volume":"7","author":"T Klinke","year":"2012","unstructured":"Klinke, T. et al. Artifacts in magnetic resonance imaging and computed tomography caused by dental materials. PloS One 7, e31766 (2012).","journal-title":"PloS One"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-50926-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-50926-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-50926-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,1,4]],"date-time":"2024-01-04T10:04:00Z","timestamp":1704362640000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-023-50926-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1,4]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["50926"],"URL":"https:\/\/doi.org\/10.1038\/s41598-023-50926-3","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1,4]]},"assertion":[{"value":"5 April 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 December 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 January 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Y. C. L. is supported by a research grant from Siemens Healthcare GmbH. The other authors declare no conflicts of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"497"}}