{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T00:38:57Z","timestamp":1785199137000,"version":"3.55.0"},"reference-count":73,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,5,3]],"date-time":"2024-05-03T00:00:00Z","timestamp":1714694400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,5,3]],"date-time":"2024-05-03T00:00:00Z","timestamp":1714694400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The perception of halos and other night vision disturbances is a common complaint in clinical practice. Such visual disturbances must be assessed in order to fully characterize each patient\u2019s visual performance, which is particularly relevant when carrying out a range of daily tasks. Visual problems are usually assessed using achromatic stimuli, yet the stimuli encountered in daily life have very different chromaticities. Hence, it is important to assess the effect of the chromaticity of visual stimuli on night vision disturbances. The aim of this work is to study the influence of the chromaticity of different visual stimuli on night vision disturbances by analyzing straylight and visual discrimination under low-light conditions. For that, we assessed the monocular and binocular visual discrimination of 27 subjects under low illumination using the Halo test. The subjects\u2019 visual discrimination was assessed after exposure to different visual stimuli: achromatic, red, green, and blue, both at the monitor\u2019s maximum luminance and maintaining the same luminance value for the different visual stimuli. Monocular straylight was also measured for an achromatic, red, green, and blue stimuli. The blue stimulus had the greatest effect on halos in both monocular and binocular conditions. Visual discrimination was similar for the red, green, and achromatic stimuli, but worsened at lower luminance. The greatest influence of straylight was observed for the blue stimulus. In addition, visual discrimination correlated with straylight measurements for achromatic stimuli, wherein greater straylight values correlated with an increased perception of halos and other visual disturbances.<\/jats:p>","DOI":"10.1038\/s41598-024-61069-4","type":"journal-article","created":{"date-parts":[[2024,5,3]],"date-time":"2024-05-03T10:03:00Z","timestamp":1714730580000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Effect of the chromaticity of stimuli on night vision disturbances"],"prefix":"10.1038","volume":"14","author":[{"given":"Jos\u00e9 J.","family":"Castro-Torres","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miriam","family":"Casares-L\u00f3pez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sonia","family":"Ortiz-Peregrina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Martino","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Luis","family":"G\u00f3mez-Robledo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos\u00e9 R.","family":"Jim\u00e9nez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,5,3]]},"reference":[{"key":"61069_CR1","doi-asserted-by":"publisher","first-page":"E130","DOI":"10.1016\/s2214-109x(20)30425-3","volume":"9","author":"RRA Bourne","year":"2021","unstructured":"Bourne, R. R. A. et al. Trends in prevalence of blindness and distance and near vision impairment over 30 years: An analysis for the global burden of disease study. Lancet Glob. Health 9, E130\u2013E143. https:\/\/doi.org\/10.1016\/s2214-109x(20)30425-3 (2021).","journal-title":"Lancet Glob. Health"},{"key":"61069_CR2","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.1001\/archopht.119.9.1371","volume":"119","author":"SD McLeod","year":"2001","unstructured":"McLeod, S. D. Beyond Snellen acuity\u2014The assessment of visual function after refractive surgery. Arch. Ophthalmol. 119, 1371\u20131373. https:\/\/doi.org\/10.1001\/archopht.119.9.1371 (2001).","journal-title":"Arch. Ophthalmol."},{"key":"61069_CR3","doi-asserted-by":"publisher","first-page":"8204","DOI":"10.1167\/iovs.12-10934","volume":"54","author":"MEF Piano","year":"2013","unstructured":"Piano, M. E. F. & O\u2019Connor, A. R. The effect of degrading binocular single vision on fine visuomotor skill task performance. Investig. Ophthalmol. Vis. Sci. 54, 8204\u20138213. https:\/\/doi.org\/10.1167\/iovs.12-10934 (2013).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"61069_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1167\/iovs.06-1073","volume":"49","author":"S Datta","year":"2008","unstructured":"Datta, S. et al. The importance of acuity, stereopsis, and contrast sensitivity for health-related quality of life in elderly women with cataracts. Investig. Ophthalmol. Vis. Sci. 49, 1\u20136. https:\/\/doi.org\/10.1167\/iovs.06-1073 (2008).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"61069_CR5","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1016\/j.jcrs.2004.12.036","volume":"31","author":"ES Rosen","year":"2005","unstructured":"Rosen, E. S. Night vision disturbance. J. Cataract Refract. Surg. 31, 247\u2013249. https:\/\/doi.org\/10.1016\/j.jcrs.2004.12.036 (2005).","journal-title":"J. Cataract Refract. Surg."},{"key":"61069_CR6","doi-asserted-by":"publisher","first-page":"4250","DOI":"10.1364\/boe.7.004250","volume":"7","author":"JJ Castro","year":"2016","unstructured":"Castro, J. J., Soler, M., Ortiz, C., Jimenez, J. R. & Anera, R. G. Binocular summation and visual function with induced anisocoria and monovision. Biomed. Opt. Express 7, 4250\u20134262. https:\/\/doi.org\/10.1364\/boe.7.004250 (2016).","journal-title":"Biomed. Opt. Express"},{"key":"61069_CR7","doi-asserted-by":"publisher","first-page":"454","DOI":"10.1111\/j.1395-3907.2004.00278.x","volume":"82","author":"A Helgesen","year":"2004","unstructured":"Helgesen, A., Hjortdal, J. & Ehlers, N. Pupil size and night vision disturbances after LASIK for myopia. Acta Ophthalmol. Scand. 82, 454\u2013460. https:\/\/doi.org\/10.1111\/j.1395-3907.2004.00278.x (2004).","journal-title":"Acta Ophthalmol. Scand."},{"key":"61069_CR8","doi-asserted-by":"publisher","first-page":"618","DOI":"10.3928\/1081597x-20130819-03","volume":"29","author":"MC Puell","year":"2013","unstructured":"Puell, M. C., Perez-Carrasco, M. J., Barrio, A., Antona, B. & Palomo-Alvarez, C. Normal values for the size of a halo produced by a glare source. J. Refract. Surg. 29, 618\u2013622. https:\/\/doi.org\/10.3928\/1081597x-20130819-03 (2013).","journal-title":"J. Refract. Surg."},{"key":"61069_CR9","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1167\/tvst.9.10.13","volume":"9","author":"L Yao","year":"2020","unstructured":"Yao, L. et al. Relationships between haloes and objective visual quality in healthy eyes. Transl. Vis. Sci. Technol. 9, 13\u201313. https:\/\/doi.org\/10.1167\/tvst.9.10.13 (2020).","journal-title":"Transl. Vis. Sci. Technol."},{"key":"61069_CR10","doi-asserted-by":"publisher","first-page":"2902","DOI":"10.1364\/boe.424715","volume":"12","author":"JJ Castro-Torres","year":"2021","unstructured":"Castro-Torres, J. J., Martino, F., Casares-Lopez, M., Ortiz-Peregrina, S. & Ortiz, C. Visual performance after the deterioration of retinal image quality: Induced forward scattering using Bangerter foils and fog filters. Biomed. Opt. Express 12, 2902\u20132918. https:\/\/doi.org\/10.1364\/boe.424715 (2021).","journal-title":"Biomed. Opt. Express"},{"key":"61069_CR11","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1007\/978-3-319-60561-6_21","volume-title":"Management of Complications in Refractive Surgery","author":"S Bidgoli","year":"2018","unstructured":"Bidgoli, S. & Ali\u00f3, J. L. In Management of Complications in Refractive Surgery (eds Alio, J. L. & Azar, D. T.) 163\u2013174 (Springer, 2018)."},{"key":"61069_CR12","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1097\/j.jcrs.0000000000000364","volume":"47","author":"T Kohnen","year":"2021","unstructured":"Kohnen, T. & Suryakumar, R. Measures of visual disturbance in patients receiving extended depth-of-focus or trifocal intraocular lenses. J. Cataract Refract. Surg. 47, 245\u2013255. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000364 (2021).","journal-title":"J. Cataract Refract. Surg."},{"key":"61069_CR13","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1016\/j.apergo.2012.11.006","volume":"44","author":"C Ortiz","year":"2013","unstructured":"Ortiz, C., Castro, J. J., Alarcon, A., Soler, M. & Anera, R. G. Quantifying age-related differences in visual-discrimination capacity: Drivers with and without visual impairment. Appl. Ergon. 44, 523\u2013531. https:\/\/doi.org\/10.1016\/j.apergo.2012.11.006 (2013).","journal-title":"Appl. Ergon."},{"key":"61069_CR14","unstructured":"Babizhayev, M. A. Disability glare effects and cataract as a problem of road safety in driving. In Cataracts: Causes, Symptoms, and Surgery 1\u201336 (2010)."},{"key":"61069_CR15","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1117\/1.3526702","volume":"16","author":"JJ Castro","year":"2011","unstructured":"Castro, J. J., Jimenez, J. R., Ortiz, C., Alarcon, A. & Anera, R. G. New testing software for quantifying discrimination capacity in subjects with ocular pathologies. J. Biomed. Opt. 16, 702. https:\/\/doi.org\/10.1117\/1.3526702 (2011).","journal-title":"J. Biomed. Opt."},{"key":"61069_CR16","doi-asserted-by":"publisher","first-page":"992","DOI":"10.1136\/bjo.2006.115139","volume":"91","author":"SD Klyce","year":"2007","unstructured":"Klyce, S. D. Night vision disturbances after refractive surgery: Haloes are not just for angels. Br. J. Ophthalmol. 91, 992\u2013993. https:\/\/doi.org\/10.1136\/bjo.2006.115139 (2007).","journal-title":"Br. J. Ophthalmol."},{"key":"61069_CR17","doi-asserted-by":"publisher","first-page":"2069","DOI":"10.1016\/j.jcrs.2015.10.047","volume":"41","author":"C Palomo-Alvarez","year":"2015","unstructured":"Palomo-Alvarez, C. & Puell, M. C. Capacity of straylight and disk halo size to diagnose cataract. J. Cataract Refract. Surg. 41, 2069\u20132074. https:\/\/doi.org\/10.1016\/j.jcrs.2015.10.047 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"61069_CR18","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1097\/01.icu.0000193065.09499.7e","volume":"17","author":"J Schwiegerling","year":"2006","unstructured":"Schwiegerling, J. Recent developments in pseudophakic dysphotopsia. Curr. Opin. Ophthalmol. 17, 27\u201330. https:\/\/doi.org\/10.1097\/01.icu.0000193065.09499.7e (2006).","journal-title":"Curr. Opin. Ophthalmol."},{"key":"61069_CR19","doi-asserted-by":"publisher","first-page":"505","DOI":"10.1097\/opx.0000000000001061","volume":"94","author":"MC Puell","year":"2017","unstructured":"Puell, M. C. & Palomo-Alvarez, C. Effects of light scatter and blur on low-contrast vision and disk halo size. Optom. Vis. Sci. 94, 505\u2013510. https:\/\/doi.org\/10.1097\/opx.0000000000001061 (2017).","journal-title":"Optom. Vis. Sci."},{"key":"61069_CR20","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1117\/1.jbo.20.7.075002","volume":"20","author":"H Ferreira-Neves","year":"2015","unstructured":"Ferreira-Neves, H. et al. Validation of a method to measure light distortion surrounding a source of glare. J. Biomed. Opt. 20, 2. https:\/\/doi.org\/10.1117\/1.jbo.20.7.075002 (2015).","journal-title":"J. Biomed. Opt."},{"key":"61069_CR21","doi-asserted-by":"publisher","first-page":"2424","DOI":"10.1016\/j.jcrs.2015.05.041","volume":"41","author":"PJ Buckhurst","year":"2015","unstructured":"Buckhurst, P. J. et al. Tablet App halometer for the assessment of dysphotopsia. J. Cataract Refract. Surg. 41, 2424\u20132429. https:\/\/doi.org\/10.1016\/j.jcrs.2015.05.041 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"61069_CR22","doi-asserted-by":"publisher","first-page":"460","DOI":"10.5301\/ejo.5000935","volume":"27","author":"R Ruiz-Mesa","year":"2017","unstructured":"Ruiz-Mesa, R., Abengozar-Vela, A., Aramburu, A. & Ruiz-Santos, M. Comparison of visual outcomes after bilateral implantation of extended range of vision and trifocal intraocular lenses. Eur. J. Ophthalmol. 27, 460\u2013465. https:\/\/doi.org\/10.5301\/ejo.5000935 (2017).","journal-title":"Eur. J. Ophthalmol."},{"key":"61069_CR23","doi-asserted-by":"publisher","first-page":"404","DOI":"10.1038\/s41433-018-0221-1","volume":"33","author":"G Savini","year":"2019","unstructured":"Savini, G. et al. Functional assessment of a new extended depth-of-focus intraocular lens. Eye 33, 404\u2013410. https:\/\/doi.org\/10.1038\/s41433-018-0221-1 (2019).","journal-title":"Eye"},{"key":"61069_CR24","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1117\/1.1607333","volume":"8","author":"R Gutierrez","year":"2003","unstructured":"Gutierrez, R., Jimenez, J. R., Villa, C., Valverde, J. A. & Anera, R. C. Simple device for quantifying the influence of halos after lasik surgery. J. Biomed. Opt. 8, 663\u2013667. https:\/\/doi.org\/10.1117\/1.1607333 (2003).","journal-title":"J. Biomed. Opt."},{"key":"61069_CR25","doi-asserted-by":"publisher","first-page":"597","DOI":"10.3928\/1081597x-20110303-01","volume":"27","author":"RG Anera","year":"2011","unstructured":"Anera, R. G., Castro, J. J., Jimenez, J. R., Villa, C. & Alarcon, A. Optical quality and visual discrimination capacity after myopic LASIK with a standard and aspheric ablation profile. J. Refract. Surg. 27, 597\u2013601. https:\/\/doi.org\/10.3928\/1081597x-20110303-01 (2011).","journal-title":"J. Refract. Surg."},{"key":"61069_CR26","doi-asserted-by":"publisher","first-page":"831","DOI":"10.1177\/11206721221138306","volume":"33","author":"WX Zhao","year":"2023","unstructured":"Zhao, W. X. et al. Evaluating early-stage disk halo changes after small incision lenticule extraction. Eur. J. Ophthalmol. 33, 831\u2013839. https:\/\/doi.org\/10.1177\/11206721221138306 (2023).","journal-title":"Eur. J. Ophthalmol."},{"key":"61069_CR27","doi-asserted-by":"publisher","first-page":"732","DOI":"10.1364\/josaa.35.000732","volume":"35","author":"GD Hastings","year":"2018","unstructured":"Hastings, G. D., Marsack, J. D., Thibos, L. N. & Applegate, R. A. Normative best-corrected values of the visual image quality metric VSX as a function of age and pupil size. J. Opt. Soc. Am. Opt. Image Sci. Vis. 35, 732\u2013739. https:\/\/doi.org\/10.1364\/josaa.35.000732 (2018).","journal-title":"J. Opt. Soc. Am. Opt. Image Sci. Vis."},{"key":"61069_CR28","doi-asserted-by":"publisher","first-page":"S270","DOI":"10.3928\/1081-597X-20030302-21","volume":"19","author":"Y Wang","year":"2003","unstructured":"Wang, Y., Zhao, K. X., Jin, Y., Niu, Y. F. & Zuo, T. Changes of higher order aberration with various pupil sizes in the myopic eye. J. Refract. Surg. 19, S270\u2013S274. https:\/\/doi.org\/10.3928\/1081-597X-20030302-21 (2003).","journal-title":"J. Refract. Surg."},{"key":"61069_CR29","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1111\/opo.12420","volume":"38","author":"RF Xu","year":"2018","unstructured":"Xu, R. F., Kollbaum, P., Thibos, L., Lopez-Gil, N. & Bradley, A. Reducing starbursts in highly aberrated eyes with pupil miosis. Ophthal. Physiol. Opt. 38, 26\u201336. https:\/\/doi.org\/10.1111\/opo.12420 (2018).","journal-title":"Ophthal. Physiol. Opt."},{"key":"61069_CR30","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1518\/0018720024494775","volume":"44","author":"J Theeuwes","year":"2002","unstructured":"Theeuwes, J., Alferdinck, J. & Perel, M. Relation between glare and driving performance. Hum. Factors 44, 95\u2013107. https:\/\/doi.org\/10.1518\/0018720024494775 (2002).","journal-title":"Hum. Factors"},{"key":"61069_CR31","doi-asserted-by":"publisher","first-page":"688","DOI":"10.1016\/j.exer.2005.09.007","volume":"82","author":"JE Coppens","year":"2006","unstructured":"Coppens, J. E., Franssen, L. & van den Berg, T. Wavelength dependence of intraocular straylight. Exp. Eye Res. 82, 688\u2013692. https:\/\/doi.org\/10.1016\/j.exer.2005.09.007 (2006).","journal-title":"Exp. Eye Res."},{"key":"61069_CR32","doi-asserted-by":"publisher","first-page":"3702","DOI":"10.1167\/iovs.13-11697","volume":"54","author":"HS Ginis","year":"2013","unstructured":"Ginis, H. S., Perez, G. M., Bueno, J. M., Pennos, A. & Artal, P. Wavelength dependence of the ocular straylight. Investig. Ophthalmol. Vis. Sci. 54, 3702\u20133708. https:\/\/doi.org\/10.1167\/iovs.13-11697 (2013).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"61069_CR33","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1111\/cxo.12198","volume":"97","author":"H Momeni-Moghaddam","year":"2014","unstructured":"Momeni-Moghaddam, H. & Goss, D. A. Comparison of four different binocular balancing techniques. Clin. Exp. Optom. 97, 422\u2013425. https:\/\/doi.org\/10.1111\/cxo.12198 (2014).","journal-title":"Clin. Exp. Optom."},{"key":"61069_CR34","doi-asserted-by":"publisher","first-page":"1389","DOI":"10.1136\/bjophthalmol-2014-304872","volume":"98","author":"MC Puell","year":"2014","unstructured":"Puell, M. C., Perez-Carrasco, M. J., Palomo-Alvarez, C., Antona, B. & Barrio, A. Relationship between halo size and forward light scatter. Br. J. Ophthalmol. 98, 1389\u20131392. https:\/\/doi.org\/10.1136\/bjophthalmol-2014-304872 (2014).","journal-title":"Br. J. Ophthalmol."},{"key":"61069_CR35","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1117\/1.jbo.21.7.075003","volume":"21","author":"R Macedo-de-Araujo","year":"2016","unstructured":"Macedo-de-Araujo, R., Ferreira-Neves, H., Rico-del-Viejo, L., Peixoto-de-Matos, S. C. & Gonzalez-Meljome, J. M. Light distortion and spherical aberration for the accommodating and nonaccommodating eye. J. Biomed. Opt. 21, 3. https:\/\/doi.org\/10.1117\/1.jbo.21.7.075003 (2016).","journal-title":"J. Biomed. Opt."},{"key":"61069_CR36","doi-asserted-by":"publisher","first-page":"1537","DOI":"10.1097\/OPX.0000000000000924","volume":"93","author":"JE Cedrun-Sanchez","year":"2016","unstructured":"Cedrun-Sanchez, J. E. et al. Visual discrimination increase by yellow filters in retinitis pigmentosa. Optom. Vis. Sci. 93, 1537\u20131544. https:\/\/doi.org\/10.1097\/OPX.0000000000000924 (2016).","journal-title":"Optom. Vis. Sci."},{"key":"61069_CR37","doi-asserted-by":"publisher","first-page":"730","DOI":"10.1111\/opo.12992","volume":"42","author":"F Martino","year":"2022","unstructured":"Martino, F. et al. Effect of interocular differences on binocular visual performance after inducing forward scattering. Ophthal. Physiol. Opt. 42, 730\u2013743. https:\/\/doi.org\/10.1111\/opo.12992 (2022).","journal-title":"Ophthal. Physiol. Opt."},{"key":"61069_CR38","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/704823","author":"JJ Castro","year":"2014","unstructured":"Castro, J. J., Pozo, A. M., Rubino, M., Anera, R. G. & del Barco, L. J. Retinal-image quality and night-vision performance after alcohol consumption. J. Ophthalmol. https:\/\/doi.org\/10.1155\/2014\/704823 (2014).","journal-title":"J. Ophthalmol."},{"key":"61069_CR39","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1038\/s41598-020-70645-3","volume":"10","author":"M Casares-Lopez","year":"2020","unstructured":"Casares-Lopez, M. et al. Contrast sensitivity and retinal straylight after alcohol consumption: Effects on driving performance. Sci. Rep. 10, 3. https:\/\/doi.org\/10.1038\/s41598-020-70645-3 (2020).","journal-title":"Sci. Rep."},{"key":"61069_CR40","doi-asserted-by":"publisher","unstructured":"Castro, J. J., Pozo, A. M. & Rubino, M. Color dependence with horizontal-viewing angle and colorimetric characterization of two displays using different backlighting. In Proc. SPIE 8785, 8th Iberoamerican Optics Meeting and 11th Latin American Meeting on Optics, Lasers, and Applications 87854C. https:\/\/doi.org\/10.1117\/12.2026171 (2013).","DOI":"10.1117\/12.2026171"},{"key":"61069_CR41","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1016\/j.ajo.2007.05.037","volume":"144","author":"T Van den Berg","year":"2007","unstructured":"Van den Berg, T. et al. Straylight effects with aging and lens extraction. Am. J. Ophthalmol. 144, 358\u2013363. https:\/\/doi.org\/10.1016\/j.ajo.2007.05.037 (2007).","journal-title":"Am. J. Ophthalmol."},{"key":"61069_CR42","doi-asserted-by":"publisher","first-page":"345","DOI":"10.1111\/j.1475-1313.2009.00638.x","volume":"29","author":"T van den Berg","year":"2009","unstructured":"van den Berg, T., Franssen, L. & Coppens, J. E. Straylight in the human eye: Testing objectivity and optical character of the psychophysical measurement. Ophthal. Physiol. Opt. 29, 345\u2013350. https:\/\/doi.org\/10.1111\/j.1475-1313.2009.00638.x (2009).","journal-title":"Ophthal. Physiol. Opt."},{"key":"61069_CR43","doi-asserted-by":"publisher","first-page":"1406","DOI":"10.1016\/j.jcrs.2014.10.035","volume":"41","author":"G Labuz","year":"2015","unstructured":"Labuz, G., Reus, N. J. & van den Berg, T. Ocular straylight in the normal pseudophakic eye. J. Cataract Refract. Surg. 41, 1406\u20131415. https:\/\/doi.org\/10.1016\/j.jcrs.2014.10.035 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"61069_CR44","doi-asserted-by":"publisher","first-page":"496","DOI":"10.1097\/opx.0000000000001043","volume":"94","author":"G Labuz","year":"2017","unstructured":"Labuz, G., Lopez-Gil, N., van den Berg, T. & Vargas-Martin, F. Ocular straylight with different multifocal contact lenses. Optom. Vis. Sci. 94, 496\u2013504. https:\/\/doi.org\/10.1097\/opx.0000000000001043 (2017).","journal-title":"Optom. Vis. Sci."},{"key":"61069_CR45","doi-asserted-by":"publisher","first-page":"788","DOI":"10.1136\/bjo.2007.131078","volume":"92","author":"A Cervino","year":"2008","unstructured":"Cervino, A., Montes-Mico, R. & Hosking, S. L. Performance of the compensation comparison method for retinal straylight measurement: Effect of patient\u2019s age on repeatability. Br. J. Ophthalmol. 92, 788\u2013791. https:\/\/doi.org\/10.1136\/bjo.2007.131078 (2008).","journal-title":"Br. J. Ophthalmol."},{"key":"61069_CR46","doi-asserted-by":"publisher","first-page":"25217","DOI":"10.1155\/2015\/925217","volume":"2015","author":"A Iijima","year":"2015","unstructured":"Iijima, A., Shimizu, K., Kobashi, H., Saito, A. & Kamiya, K. Repeatability, reproducibility, and comparability of subjective and objective measurements of intraocular forward scattering in healthy subjects. Biomed. Res. Int. 2015, 25217. https:\/\/doi.org\/10.1155\/2015\/925217 (2015).","journal-title":"Biomed. Res. Int."},{"key":"61069_CR47","doi-asserted-by":"publisher","first-page":"1461","DOI":"10.1016\/j.jcrs.2016.08.015","volume":"42","author":"JA Martinez-Roda","year":"2016","unstructured":"Martinez-Roda, J. A. et al. Double-pass technique and compensation-comparison method in eyes with cataract. J. Cataract Refract. Surg. 42, 1461\u20131469. https:\/\/doi.org\/10.1016\/j.jcrs.2016.08.015 (2016).","journal-title":"J. Cataract Refract. Surg."},{"key":"61069_CR48","doi-asserted-by":"publisher","first-page":"3193","DOI":"10.1016\/s0042-6989(98)00060-1","volume":"38","author":"A Stockman","year":"1998","unstructured":"Stockman, A. & Sharpe, L. T. Human cone spectral sensitivities: A progress report. Vis. Res. 38, 3193\u20133206. https:\/\/doi.org\/10.1016\/s0042-6989(98)00060-1 (1998).","journal-title":"Vis. Res."},{"key":"61069_CR49","doi-asserted-by":"publisher","first-page":"29315","DOI":"10.3389\/fnint.2023.1129315","volume":"17","author":"MF Costa","year":"2023","unstructured":"Costa, M. F., Rego, L. S., Henriques, L. D., Gaddi, C. M. & Souza, G. S. Reduced eye optical quality contributes to worse chromatic thresholds in aging. Front. Integr. Neurosci. 17, 29315. https:\/\/doi.org\/10.3389\/fnint.2023.1129315 (2023).","journal-title":"Front. Integr. Neurosci."},{"key":"61069_CR50","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/s12886-022-02621-6","volume":"22","author":"J Pepose","year":"2022","unstructured":"Pepose, J. et al. A randomized phase 2 clinical trial of phentolamine mesylate eye drops in patients with severe night vision disturbances. BMC Ophthalmol. 22, 6. https:\/\/doi.org\/10.1186\/s12886-022-02621-6 (2022).","journal-title":"BMC Ophthalmol."},{"key":"61069_CR51","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1111\/j.1444-0938.2003.tb03111.x","volume":"86","author":"W Adrian","year":"2003","unstructured":"Adrian, W. Spectral sensitivity of the pupillary system. Clin. Exp. Optom. 86, 235\u2013238. https:\/\/doi.org\/10.1111\/j.1444-0938.2003.tb03111.x (2003).","journal-title":"Clin. Exp. Optom."},{"key":"61069_CR52","doi-asserted-by":"publisher","first-page":"2375","DOI":"10.1167\/iovs.06-0759","volume":"48","author":"L Franssen","year":"2007","unstructured":"Franssen, L., Tabernero, J., Coppens, J. E. & van den Berg, T. Pupil size and retinal straylight in the normal eye. Investig. Ophthalmol. Vis. Sci. 48, 2375\u20132382. https:\/\/doi.org\/10.1167\/iovs.06-0759 (2007).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"61069_CR53","doi-asserted-by":"publisher","first-page":"4309","DOI":"10.1016\/s0042-6989(99)00145-5","volume":"39","author":"S Marcos","year":"1999","unstructured":"Marcos, S., Burns, S. A., Moreno-Barriusop, E. & Navarro, R. A new approach to the study of ocular chromatic aberrations. Vis. Res. 39, 4309\u20134323. https:\/\/doi.org\/10.1016\/s0042-6989(99)00145-5 (1999).","journal-title":"Vis. Res."},{"key":"61069_CR54","doi-asserted-by":"publisher","first-page":"7748","DOI":"10.1364\/oe.16.007748","volume":"16","author":"S Manzanera","year":"2008","unstructured":"Manzanera, S., Canovas, C., Prieto, P. M. & Artal, P. A wavelength tunable wavefront sensor for the human eye. Opt. Express 16, 7748\u20137755. https:\/\/doi.org\/10.1364\/oe.16.007748 (2008).","journal-title":"Opt. Express"},{"key":"61069_CR55","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1016\/j.ijleo.2007.01.002","volume":"119","author":"M Liu","year":"2008","unstructured":"Liu, M., Wang, Z.-Q., Wang, Y., Zuo, T. & Wang, Y. The study of wavelength-dependent wavefront aberrations based on individual eye model. Optik 119, 383\u2013387. https:\/\/doi.org\/10.1016\/j.ijleo.2007.01.002 (2008).","journal-title":"Optik"},{"key":"61069_CR56","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1016\/0042-6989(86)90034-9","volume":"26","author":"PA Howarth","year":"1986","unstructured":"Howarth, P. A. & Bradley, A. The longitudinal chromatic aberration of the human-eye, and its correction. Vis. Res. 26, 361\u2013366. https:\/\/doi.org\/10.1016\/0042-6989(86)90034-9 (1986).","journal-title":"Vis. Res."},{"key":"61069_CR57","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1034\/j.1600-0420.2001.079001060.x","volume":"79","author":"RS Anderson","year":"2001","unstructured":"Anderson, R. S., McDowell, R. D. & Ennis, F. A. Effect of localized defocus on detection thresholds for different sized targets in the fovea and periphery. Acta Ophthalmol. Scand. 79, 60\u201363. https:\/\/doi.org\/10.1034\/j.1600-0420.2001.079001060.x (2001).","journal-title":"Acta Ophthalmol. Scand."},{"key":"61069_CR58","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1002\/cne.903120411","volume":"312","author":"CA Curcio","year":"1991","unstructured":"Curcio, C. A. et al. Distribution and morphology of human cone photoreceptors stained with anti-blue opsin. J. Compar. Neurol. 312, 610\u2013624. https:\/\/doi.org\/10.1002\/cne.903120411 (1991).","journal-title":"J. Compar. Neurol."},{"key":"61069_CR59","doi-asserted-by":"publisher","first-page":"40239","DOI":"10.1371\/journal.pone.0040239","volume":"7","author":"P Artal","year":"2012","unstructured":"Artal, P., Schwarz, C., Canovas, C. & Mira-Agudelo, A. Night myopia studied with an adaptive optics visual analyzer. PLoS ONE 7, 40239. https:\/\/doi.org\/10.1371\/journal.pone.0040239 (2012).","journal-title":"PLoS ONE"},{"key":"61069_CR60","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1111\/opo.12368","volume":"37","author":"T van den Berg","year":"2017","unstructured":"van den Berg, T. The (lack of) relation between straylight and visual acuity. Two domains of the point-spread-function. Ophthal. Physiol. Opt. 37, 333\u2013341. https:\/\/doi.org\/10.1111\/opo.12368 (2017).","journal-title":"Ophthal. Physiol. Opt."},{"key":"61069_CR61","doi-asserted-by":"publisher","first-page":"821","DOI":"10.3390\/vehicles3040049","volume":"3","author":"A Erkan","year":"2021","unstructured":"Erkan, A. et al. Determination of speed-dependent roadway luminance for an adequate feeling of safety at nighttime driving. Vehicles 3, 821\u2013839. https:\/\/doi.org\/10.3390\/vehicles3040049 (2021).","journal-title":"Vehicles"},{"key":"61069_CR62","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1016\/j.rser.2014.08.028","volume":"41","author":"XM Long","year":"2015","unstructured":"Long, X. M. et al. A review on light-emitting diode based automotive headlamps. Renew. Sustain. Energy Rev. 41, 29\u201341. https:\/\/doi.org\/10.1016\/j.rser.2014.08.028 (2015).","journal-title":"Renew. Sustain. Energy Rev."},{"key":"61069_CR63","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1007\/s12239-010-0087-0","volume":"11","author":"B Kang","year":"2010","unstructured":"Kang, B., Yong, B. & Park, K. Performance evaluations of LED headlamps. Int. J. Autom. Technol. 11, 737\u2013742. https:\/\/doi.org\/10.1007\/s12239-010-0087-0 (2010).","journal-title":"Int. J. Autom. Technol."},{"key":"61069_CR64","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1109\/mce.2020.3040724","volume":"10","author":"CM Luo","year":"2021","unstructured":"Luo, C. M., Xin, G. F., Xu, H. & Tang, W. Glare-free high-beam control for oncoming vehicle safety in nighttime. IEEE Consum. Electron. Mag. 10, 8\u201315. https:\/\/doi.org\/10.1109\/mce.2020.3040724 (2021).","journal-title":"IEEE Consum. Electron. Mag."},{"key":"61069_CR65","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1088\/2053-1613\/2\/3\/035002","volume":"2","author":"D Caruso","year":"2015","unstructured":"Caruso, D. et al. Market evaluation, performance modelling and materials solution addressing short wavelength discomfort glare in rear view automotive mirrors. Transl. Mater. Res. 2, 2. https:\/\/doi.org\/10.1088\/2053-1613\/2\/3\/035002 (2015).","journal-title":"Transl. Mater. Res."},{"key":"61069_CR66","doi-asserted-by":"publisher","first-page":"0227892","DOI":"10.1371\/journal.pone.0227892","volume":"15","author":"S Ortiz-Peregrina","year":"2020","unstructured":"Ortiz-Peregrina, S. et al. Intraocular scattering as a predictor of driving performance in older adults with cataracts. PLoS ONE 15, 0227892. https:\/\/doi.org\/10.1371\/journal.pone.0227892 (2020).","journal-title":"PLoS ONE"},{"key":"61069_CR67","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1111\/cxo.12447","volume":"99","author":"RA Tyrrell","year":"2016","unstructured":"Tyrrell, R. A., Wood, J. M., Owens, D. A., Borzendowski, S. W. & Sewall, A. S. The conspicuity of pedestrians at night: A review. Clin. Exp. Optom. 99, 425\u2013434. https:\/\/doi.org\/10.1111\/cxo.12447 (2016).","journal-title":"Clin. Exp. Optom."},{"key":"61069_CR68","doi-asserted-by":"publisher","first-page":"164","DOI":"10.3389\/fpsyg.2018.00164","volume":"9","author":"AD Hwang","year":"2018","unstructured":"Hwang, A. D., Tuccar-Burak, M., Goldstein, R. & Peli, E. Impact of oncoming headlight glare with cataracts: A pilot study. Front. Psychol. 9, 164. https:\/\/doi.org\/10.3389\/fpsyg.2018.00164 (2018).","journal-title":"Front. Psychol."},{"key":"61069_CR69","doi-asserted-by":"publisher","first-page":"552","DOI":"10.3928\/1081597x-20220802-02","volume":"38","author":"XM Liu","year":"2022","unstructured":"Liu, X. M., Wu, X. M. & Huang, Y. S. Laboratory evaluation of halos and through-focus performance of three different multifocal intraocular lenses. J. Refract. Surg. 38, 552. https:\/\/doi.org\/10.3928\/1081597x-20220802-02 (2022).","journal-title":"J. Refract. Surg."},{"key":"61069_CR70","doi-asserted-by":"publisher","first-page":"1460","DOI":"10.18240\/ijo.2022.09.08","volume":"15","author":"N Hui","year":"2022","unstructured":"Hui, N. et al. Comparative analysis of visual quality between unilateral implantation of a trifocal intraocular lens and a rotationally asymmetric refractive multifocal intraocular lens. Int. J. Ophthalmol. 15, 1460\u20131467 (2022).","journal-title":"Int. J. Ophthalmol."},{"key":"61069_CR71","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1186\/s40662-023-00350-5","volume":"10","author":"MS Millan","year":"2023","unstructured":"Millan, M. S., Clave, L., Torrents, A., Armengol, J. & Vega, F. Spatio-chromatic vision with multifocal diffractive intraocular lens. Eye Vis. 10, 5. https:\/\/doi.org\/10.1186\/s40662-023-00350-5 (2023).","journal-title":"Eye Vis."},{"key":"61069_CR72","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1016\/j.survophthal.2009.07.007","volume":"55","author":"BA Henderson","year":"2010","unstructured":"Henderson, B. A. & Grimes, K. J. Blue-blocking IOLs: A complete review of the literature. Surv. Ophthalmol. 55, 284\u2013289. https:\/\/doi.org\/10.1016\/j.survophthal.2009.07.007 (2010).","journal-title":"Surv. Ophthalmol."},{"key":"61069_CR73","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1159\/000521306","volume":"65","author":"AFV Cueto","year":"2022","unstructured":"Cueto, A. F. V. et al. Protector role of intraocular lenses under artificial light conditions. Ophthal. Res. 65, 276\u2013286. https:\/\/doi.org\/10.1159\/000521306 (2022).","journal-title":"Ophthal. Res."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-61069-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-61069-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-61069-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,3]],"date-time":"2024-05-03T10:08:54Z","timestamp":1714730934000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-61069-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,3]]},"references-count":73,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["61069"],"URL":"https:\/\/doi.org\/10.1038\/s41598-024-61069-4","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,3]]},"assertion":[{"value":"17 October 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 April 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 May 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10183"}}