{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T05:34:49Z","timestamp":1784698489385,"version":"3.55.0"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,5,31]],"date-time":"2024-05-31T00:00:00Z","timestamp":1717113600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,5,31]],"date-time":"2024-05-31T00:00:00Z","timestamp":1717113600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>This study investigated the underlying causes of the myopic outcomes of the optic-based newer formulas (Barrett Universal II, EVO 2.0, Kane, Hoffer-QST and PEARL-DGS) in long Korean eyes with Alcon TFNT intraocular lens (IOL) implantation. Postoperative data from 3100 randomly selected eyes of 3100 patients were analyzed to compare the reference back-calculated effective lens positions (ELPs) based on the Haigis formula using conventional axial length (AL) and Cooke-modified AL (CMAL) with the predicted ELP of each single- and triple-optimized Haigis formula applied to AL- and CMAL. Contrary to the AL-applied Haigis formula, the predicted ELP curve of the CMAL-applied, single-optimized Haigis formula, simulating the methods of the newer formulas, exhibited a significant upward deviation from the back-calculated ELP in long eyes. The relationship between the AL and anterior chamber depth in our long-eyed population differed from that in the base population of the PEARL-DGS formula. The myopic outcomes in long eyes appeared to stem from the substantial overestimation of the postoperative IOL position with AL modification, leading to the implantation of inappropriately higher-powered IOLs. This discrepancy may be attributed to the ethnic differences in ocular biometrics, particularly the relatively smaller anterior segment in East Asian patients with long AL.<\/jats:p>","DOI":"10.1038\/s41598-024-63334-y","type":"journal-article","created":{"date-parts":[[2024,5,31]],"date-time":"2024-05-31T16:03:31Z","timestamp":1717171411000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Investigation of the myopic outcomes of the newer intraocular lens power calculation formulas in Korean patients with long eyes"],"prefix":"10.1038","volume":"14","author":[{"given":"Jinchul","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joonsung","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoonjung","family":"Jo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,5,31]]},"reference":[{"key":"63334_CR1","doi-asserted-by":"publisher","first-page":"4848","DOI":"10.3390\/jcm11164848","volume":"11","author":"M Omoto","year":"2022","unstructured":"Omoto, M. et al. Investigating the prediction accuracy of recently updated intraocular lens power formulas with artificial intelligence for high myopia. J. Clin. Med. 11, 4848 (2022).","journal-title":"J. Clin. Med."},{"key":"63334_CR2","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1080\/02713683.2019.1698053","volume":"45","author":"H Cheng","year":"2020","unstructured":"Cheng, H. Accuracy of modified axial length adjustment for intraocular lens power calculation in chinese axial myopic eyes. Curr. Eye Res. 45, 827\u2013833 (2020).","journal-title":"Curr. Eye Res."},{"key":"63334_CR3","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1007\/s10792-012-9690-6","volume":"33","author":"T Yokoi","year":"2013","unstructured":"Yokoi, T., Moriyama, M., Hayashi, K., Shimada, N. & Ohno-Matsui, K. Evaluation of refractive error after cataract surgery in highly myopic eyes. Int. Ophthalmol. 33, 343\u2013348 (2013).","journal-title":"Int. Ophthalmol."},{"key":"63334_CR4","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.ajo.2019.04.019","volume":"205","author":"KH Wan","year":"2019","unstructured":"Wan, K. H., Lam, T. C. H., Yu, M. C. Y. & Chan, T. C. Y. Accuracy and precision of intraocular lens calculations using the new Hill-RBF Version 20 in eyes with high axial myopia. Am. J. Ophthalmol. 205, 66\u201373 (2019).","journal-title":"Am. J. Ophthalmol."},{"key":"63334_CR5","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1016\/j.ajo.2020.02.023","volume":"214","author":"Z Jiaqing","year":"2020","unstructured":"Jiaqing, Z. et al. Effect of axial length adjustment methods on intraocular lens power calculation in highly myopic eyes. Am. J. Ophthalmol. 214, 110 (2020).","journal-title":"Am. J. Ophthalmol."},{"key":"63334_CR6","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1016\/j.jcrs.2014.06.033","volume":"41","author":"A Abulafia","year":"2015","unstructured":"Abulafia, A. et al. Intraocular lens power calculation for eyes with an axial length greater than 26.0 mm: Comparison of formulas and methods. J. Cataract Refract. Surg. 41, 548\u2013556 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"63334_CR7","doi-asserted-by":"publisher","first-page":"725","DOI":"10.1016\/j.jcrs.2019.01.018","volume":"45","author":"J Liu","year":"2019","unstructured":"Liu, J. et al. Comparison of intraocular lens power calculation formulas in Chinese eyes with axial myopia. J. Cataract Refract. Surg. 45, 725\u2013731 (2019).","journal-title":"J. Cataract Refract. Surg."},{"key":"63334_CR8","doi-asserted-by":"publisher","first-page":"1575","DOI":"10.1016\/j.jcrs.2009.04.028","volume":"35","author":"K Petermeier","year":"2009","unstructured":"Petermeier, K. et al. Intraocular lens power calculation and optimized constants for highly myopic eyes. J. Cataract Refract. Surg. 35, 1575\u20131581 (2009).","journal-title":"J. Cataract Refract. Surg."},{"key":"63334_CR9","doi-asserted-by":"publisher","first-page":"685","DOI":"10.1097\/j.jcrs.0000000000000821","volume":"48","author":"G Savini","year":"2022","unstructured":"Savini, G., Hoffer, K., Carballo, L., Taroni, L. & Schiano-Lomoriello, D. A comparison of different methods to calculate the axial length measured by optical biometry. J. Cataract Refract. Surg. 48, 685\u2013689 (2022).","journal-title":"J. Cataract Refract. Surg."},{"key":"63334_CR10","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1016\/j.jcrs.2018.12.026","volume":"45","author":"D Cooke","year":"2019","unstructured":"Cooke, D. & Cooke, T. L. Approximating sum-of-segments axial length from a traditional optical low-coherence reflectometry measurement. J. Cataract Refract. Surg. 45, 351\u2013354 (2019).","journal-title":"J. Cataract Refract. Surg."},{"key":"63334_CR11","doi-asserted-by":"publisher","first-page":"2018","DOI":"10.1016\/j.jcrs.2011.05.042","volume":"37","author":"L Wang","year":"2011","unstructured":"Wang, L., Shirayama, M., Kohnen, T. & Koch, D. Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm. J. Cataract Refract. Surg. 37, 2018\u20132027 (2011).","journal-title":"J. Cataract Refract. Surg."},{"key":"63334_CR12","doi-asserted-by":"publisher","first-page":"1396","DOI":"10.1016\/j.jcrs.2018.07.049","volume":"44","author":"L Wang","year":"2018","unstructured":"Wang, L. & Koch, D. D. Modified axial length adjustment formulas in long eyes. J. Cataract Refract. Surg. 44, 1396 (2018).","journal-title":"J. Cataract Refract. Surg."},{"key":"63334_CR13","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.ophtha.2017.08.027","volume":"125","author":"RB Melles","year":"2018","unstructured":"Melles, R. B., Holladay, J. T. & Chang, W. J. Accuracy of intraocular lens calculation formulas. Ophthalmology. 125, 169\u2013178 (2018).","journal-title":"Ophthalmology."},{"key":"63334_CR14","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/j.jcrs.2017.09.035","volume":"44","author":"M Popovic","year":"2018","unstructured":"Popovic, M., Schlenker, M. B., Campos-M\u00f6ller, X., Pereira, A. & Ahmed, I. I. K. Wang-Koch formula for optimization of intraocular lens power calculation: Evaluation at a Canadian center. J. Cataract Refract. Surg. 44, 17\u201322 (2018).","journal-title":"J. Cataract Refract. Surg."},{"key":"63334_CR15","doi-asserted-by":"publisher","first-page":"1334","DOI":"10.1016\/j.ophtha.2019.04.011","volume":"126","author":"R Melles","year":"2019","unstructured":"Melles, R., Kane, J. X., Olsen, T. & Chang, W. J. Update on intraocular lens calculation formulas. Ophthalmology 126, 1334\u20131335 (2019).","journal-title":"Ophthalmology"},{"key":"63334_CR16","doi-asserted-by":"publisher","first-page":"1490","DOI":"10.1016\/j.jcrs.2016.07.021","volume":"42","author":"JX Kane","year":"2016","unstructured":"Kane, J. X., Heerden, A. V., Atik, A. & Petsoglou, C. Intraocular lens power formula accuracy: Comparison of 7 formulas. J. Cataract Refract. Surg. 42, 1490\u20131500 (2016).","journal-title":"J. Cataract Refract. Surg."},{"key":"63334_CR17","doi-asserted-by":"publisher","first-page":"225","DOI":"10.4103\/2211-5056.357849","volume":"13","author":"W Stopyra","year":"2022","unstructured":"Stopyra, W. Analysis of accuracy of twelve intraocular lens power calculation formulas for eyes with axial myopia. Taiwan J. Ophthalmol. 13, 225\u2013230 (2022).","journal-title":"Taiwan J. Ophthalmol."},{"key":"63334_CR18","doi-asserted-by":"publisher","first-page":"4462","DOI":"10.1038\/s41598-024-54889-x","volume":"14","author":"J Kim","year":"2024","unstructured":"Kim, J., Park, J. & Jo, Y. Comparison of the formula accuracy for calculating multifocal intraocular lens power: A single center retrospective study in Korean patients. Sci. Rep. 14, 4462 (2024).","journal-title":"Sci. Rep."},{"key":"63334_CR19","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.ajo.2021.05.004","volume":"232","author":"G Debellemani\u00e8re","year":"2021","unstructured":"Debellemani\u00e8re, G. et al. The PEARL-DGS formula: The development of an open-source machine learning\u2013based thick IOL calculation formula. Am. J. Ophthalmol. 232, 58\u201369 (2021).","journal-title":"Am. J. Ophthalmol."},{"key":"63334_CR20","doi-asserted-by":"publisher","first-page":"765","DOI":"10.1007\/s004170000188","volume":"238","author":"W Haigis","year":"2000","unstructured":"Haigis, W., Lege, B., Miller, N. & Schneider, B. Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis. Graefes Arch. Clin. Exp. Ophthalmol. 238, 765\u2013773 (2000).","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"63334_CR21","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1016\/j.jcrs.2018.10.039","volume":"45","author":"D Cooke","year":"2019","unstructured":"Cooke, D. & Cooke, T. L. A comparison of two methods to calculate axial length. J. Cataract Refract. Surg. 45, 284\u2013292 (2019).","journal-title":"J. Cataract Refract. Surg."},{"key":"63334_CR22","doi-asserted-by":"publisher","first-page":"1356","DOI":"10.1016\/S0886-3350(97)80115-0","volume":"23","author":"J Holladay","year":"1997","unstructured":"Holladay, J. Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations. J. Cataract Refract. Surg. 23, 1356\u20131370 (1997).","journal-title":"J. Cataract Refract. Surg."},{"key":"63334_CR23","doi-asserted-by":"publisher","first-page":"184","DOI":"10.3390\/jcm12010184","volume":"12","author":"N Mechleb","year":"2022","unstructured":"Mechleb, N. et al. Using the first-eye back-calculated effective lens position to improve refractive outcome of the second eye. J. Clin Med. 12, 184 (2022).","journal-title":"J. Clin Med."},{"key":"63334_CR24","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1167\/tvst.11.9.5","volume":"11","author":"D Gatinel","year":"2022","unstructured":"Gatinel, D., Debellemani\u00e8re, G., Saad, A. & Rampat, R. Theoretical relationship among effective lens position, predicted refraction, and corneal and intraocular lens power in a pseudophakic eye model. Transl. Vis. Sci. Technol. 11, 5 (2022).","journal-title":"Transl. Vis. Sci. Technol."},{"issue":"22","key":"63334_CR25","first-page":"00124","volume":"S0939\u20133889","author":"A Langenbucher","year":"2022","unstructured":"Langenbucher, A. et al. Considerations of a thick lens formula for intraocular lens power calculation. Z. Med. Phys. S0939\u20133889(22), 00124\u201300126 (2022).","journal-title":"Z. Med. Phys."},{"key":"63334_CR26","doi-asserted-by":"publisher","first-page":"e1008671","DOI":"10.1371\/journal.pcbi.1008671","volume":"17","author":"J Dem\u0161ar","year":"2021","unstructured":"Dem\u0161ar, J. & Zupan, B. Hands-on training about overfitting. PLOS Comput. Biol. 17, e1008671 (2021).","journal-title":"PLOS Comput. Biol."},{"key":"63334_CR27","doi-asserted-by":"publisher","first-page":"1511","DOI":"10.2147\/OPTH.S256851","volume":"14","author":"H Shammas","year":"2020","unstructured":"Shammas, H., Shammas, M. C., Jivrajka, R., Cooke, D. & Potvin, R. Effects on IOL power calculation and expected clinical outcomes of axial length measurements based on multiple vs single refractive indices. Clin. Ophthalmol. 14, 1511\u20131519 (2020).","journal-title":"Clin. Ophthalmol."},{"key":"63334_CR28","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1186\/s40662-021-00265-z","volume":"8","author":"Y Mori","year":"2021","unstructured":"Mori, Y. et al. Machine learning adaptation of intraocular lens power calculation for a patient group. Eye Vis. 8, 42 (2021).","journal-title":"Eye Vis."},{"key":"63334_CR29","doi-asserted-by":"publisher","first-page":"1184","DOI":"10.1136\/bjo.2009.167296","volume":"94","author":"CK Leung","year":"2010","unstructured":"Leung, C. K. et al. Comparisons of anterior segment biometry between Chinese and Caucasians using anterior segment optical coherence tomography. Br. J. Ophthalmol. 94, 1184\u20131189 (2010).","journal-title":"Br. J. Ophthalmol."},{"key":"63334_CR30","doi-asserted-by":"publisher","first-page":"7346","DOI":"10.1038\/s41598-021-86604-5","volume":"11","author":"A Choi","year":"2021","unstructured":"Choi, A., Kwon, H. & Jeon, S. Accuracy of theoretical IOL formulas for Panoptix intraocular lens according to axial length. Sci. Rep. 11, 7346 (2021).","journal-title":"Sci. Rep."},{"key":"63334_CR31","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1016\/j.ajo.2023.09.009","volume":"257","author":"Y Ma","year":"2024","unstructured":"Ma, Y. et al. Network meta-analysis of intraocular lens power calculation formula accuracy in 1016 eyes with long axial length. Am. J. Ophthalmol. 257, 178\u2013186 (2024).","journal-title":"Am. J. Ophthalmol."},{"key":"63334_CR32","doi-asserted-by":"publisher","first-page":"663","DOI":"10.1016\/j.ophtha.2018.12.046","volume":"126","author":"L Wang","year":"2019","unstructured":"Wang, L., Cao, D., Weikert, M. P. & Koch, D. Calculation of axial length using a single group refractive index versus using different refractive indices for each ocular segment: Theoretical study and refractive outcomes. Ophthalmology 126, 663\u2013670 (2019).","journal-title":"Ophthalmology"},{"key":"63334_CR33","doi-asserted-by":"publisher","first-page":"202","DOI":"10.3928\/1081597X-20210104-01","volume":"37","author":"L Taroni","year":"2021","unstructured":"Taroni, L., Hoffer, K. J., Lupardi, E., Barboni, P. & Savini, G. Accuracy of new intraocular lens power calculation formulas: A lens thickness study. J. Refract. Surg. 37, 202\u2013206 (2021).","journal-title":"J. Refract. Surg."},{"key":"63334_CR34","doi-asserted-by":"publisher","first-page":"1422","DOI":"10.1016\/j.jcrs.2019.05.021","volume":"45","author":"K N\u00e6ser","year":"2019","unstructured":"N\u00e6ser, K. & Savini, G. Accuracy of thick-lens intraocular lens power calculation based on cutting-card or calculated data for lens architecture. J. Cataract Refract. Surg. 45, 1422\u20131429 (2019).","journal-title":"J. Cataract Refract. Surg."},{"key":"63334_CR35","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.ajo.2023.05.005","volume":"253","author":"D Gatinel","year":"2023","unstructured":"Gatinel, D. et al. A simplified method to minimize systematic bias of single-optimized intraocular lens power calculation formulas. Am. J. Ophthalmol. 253, 65\u201373 (2023).","journal-title":"Am. J. Ophthalmol."},{"key":"63334_CR36","doi-asserted-by":"publisher","first-page":"e115","DOI":"10.1016\/j.ophtha.2020.07.005","volume":"128","author":"KJ Hoffer","year":"2021","unstructured":"Hoffer, K. J. & Savini, G. Update on intraocular lens power calculation study protocols: The better way to design and report clinical trials. Ophthalmology. 128, e115\u2013e120 (2021).","journal-title":"Ophthalmology."},{"key":"63334_CR37","unstructured":"Debellemani\u00e8re, G. pearldgs_toolbox. https:\/\/github.com\/gdebel\/pearldgs_toolbox (2022)."},{"key":"63334_CR38","doi-asserted-by":"publisher","first-page":"700","DOI":"10.1016\/S0886-3350(13)80338-0","volume":"19","author":"K Hoffer","year":"1993","unstructured":"Hoffer, K. The Hoffer Q formula: A comparison of theoretic and regression formulas. J. Cataract. Refract. Surg. 19, 700\u2013712 (1993).","journal-title":"J. Cataract. Refract. Surg."},{"key":"63334_CR39","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/S0886-3350(88)80059-2","volume":"14","author":"J Holladay","year":"1988","unstructured":"Holladay, J. et al. A three-part system for refining intraocular lens power calculations. J. Cataract. Refract. Surg. 14, 17\u201324 (1988).","journal-title":"J. Cataract. Refract. Surg."},{"key":"63334_CR40","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/S0886-3350(13)80705-5","volume":"16","author":"J Retzlaff","year":"1990","unstructured":"Retzlaff, J., Sanders, D. & Kraff, M. Development of the SRK\/T intraocular lens implant power calculation formula. J. Cataract Refract. Surg. 16, 333\u2013340 (1990).","journal-title":"J. Cataract Refract. Surg."},{"key":"63334_CR41","doi-asserted-by":"publisher","first-page":"440","DOI":"10.1097\/j.jcrs.0000000000001165","volume":"49","author":"JT Holladay","year":"2023","unstructured":"Holladay, J. T., Wilcox, R. R., Koch, D. D. & Wang, L. Statistics of prediction error for non-Gaussian dependent and independent datasets. J. Cataract Refract. Surg. 49, 440\u2013442 (2023).","journal-title":"J. Cataract Refract. Surg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-63334-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-63334-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-63334-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,31]],"date-time":"2024-05-31T16:06:42Z","timestamp":1717171602000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-63334-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,31]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["63334"],"URL":"https:\/\/doi.org\/10.1038\/s41598-024-63334-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,31]]},"assertion":[{"value":"2 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 May 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 May 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"12558"}}