{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,3]],"date-time":"2026-04-03T03:52:58Z","timestamp":1775188378530,"version":"3.50.1"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,6,10]],"date-time":"2024-06-10T00:00:00Z","timestamp":1717977600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,6,10]],"date-time":"2024-06-10T00:00:00Z","timestamp":1717977600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Joint Program of Henan Provincial Medical Science & Technology Plan","award":["LHGJ20220086"],"award-info":[{"award-number":["LHGJ20220086"]}]},{"name":"Henan Provincial Science and Technology Research and Development Plan Joint Fund Project","award":["232103810052"],"award-info":[{"award-number":["232103810052"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>To optimize and evaluate the accuracy of the vault-predicting formula generated from a very high-frequency digital ultrasound robotic scanner (Artemis Insight 100). The relationship between the achieved lens vault (LVa) at one month after intraocular collamer lens (ICL) implantation surgery and the predicted vault (LVp) was analyzed by a retrospective study, and an optimized formula was built up. Then, the accuracy of the optimized vault-predicting formula was evaluated in a prospective study by comparing the LVa and the predicted vault from the optimized formula (LVop). The retrospective study included 77 patients (133 eyes) while the prospective study enrolled 90 patients (170 eyes). The difference between LVp and LVa at one month after surgery was statistically significant (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05), and the linear regression analysis of LVa against LVp yielded a good fit (<jats:italic>R<\/jats:italic><jats:sup><jats:italic>2<\/jats:italic><\/jats:sup>\u2009=\u20090.68). The optimized vault-predicting formula was LVop (\u03bcm)\u2009=\u20091.21\u2009\u00d7\u2009LVp (\u03bcm)\u2009+\u2009124.73. In the validation study, the difference between LVop and LVa was not statistically significant (<jats:italic>P<\/jats:italic>\u2009=\u20090.10), and a good agreement between LVop and LVa was shown by Bland\u2013Altman analysis. The optimized vault-predicting formula could predict the actual LV after ICL implantation surgery, help to select an appropriate ICL size and reduce the need for re-operation.<\/jats:p>","DOI":"10.1038\/s41598-024-64390-0","type":"journal-article","created":{"date-parts":[[2024,6,10]],"date-time":"2024-06-10T13:02:22Z","timestamp":1718024542000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["The optimization of the vault-predicting formula based on the anterior segment measurements from artemis insight 100"],"prefix":"10.1038","volume":"14","author":[{"given":"Hao","family":"Wang","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bo","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wenwen","family":"Du","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zaohe","family":"Sun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qi","family":"Fan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chenjiu","family":"Pang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,6,10]]},"reference":[{"key":"64390_CR1","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1016\/j.ajo.2009.02.001","volume":"148","author":"A Igarashi","year":"2009","unstructured":"Igarashi, A., Kamiya, K., Shimizu, K. & Komatsu, M. Visual performance after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis for high myopia. Am. J. Ophthalmol. 148, 164\u2013170. https:\/\/doi.org\/10.1016\/j.ajo.2009.02.001 (2009).","journal-title":"Am. J. Ophthalmol."},{"key":"64390_CR2","doi-asserted-by":"publisher","first-page":"273","DOI":"10.2147\/OPTH.S120427w","volume":"11","author":"PJ Dougherty","year":"2017","unstructured":"Dougherty, P. J. & Priver, T. Refractive outcomes and safety of the implantable collamer lens in young low-to-moderate myopes. Clin. Ophthalmol. 11, 273\u2013277. https:\/\/doi.org\/10.2147\/OPTH.S120427w (2017).","journal-title":"Clin. Ophthalmol."},{"key":"64390_CR3","doi-asserted-by":"publisher","first-page":"169","DOI":"10.3928\/1081597X-20190118-01","volume":"35","author":"JF Alfonso","year":"2019","unstructured":"Alfonso, J. F., Fernandez-Vega-Cueto, L., Alfonso-Bartolozzi, B., Montes-Mico, R. & Fernandez-Vega, L. Five-year follow-up of correction of myopia: posterior chamber Phakic intraocular Lens with a central port design. J. Refract. Surg. 35, 169\u2013176. https:\/\/doi.org\/10.3928\/1081597X-20190118-01 (2019).","journal-title":"J. Refract. Surg."},{"key":"64390_CR4","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/j.jcrs.2014.11.011","volume":"41","author":"K Kamiya","year":"2015","unstructured":"Kamiya, K. et al. Comparison of vault after implantation of posterior chamber phakic intraocular lens with and without a central hole. J. Cataract Refract. Surg. 41, 67\u201372. https:\/\/doi.org\/10.1016\/j.jcrs.2014.11.011 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"64390_CR5","doi-asserted-by":"publisher","first-page":"1153","DOI":"10.1016\/j.jcrs.2014.10.030","volume":"41","author":"C Lisa","year":"2015","unstructured":"Lisa, C. et al. Posterior chamber collagen copolymer phakic intraocular lens with a central hole to correct yopia: One-year follow-up. J. Cataract Refract. Surg. 41, 1153\u20131159. https:\/\/doi.org\/10.1016\/j.jcrs.2014.10.030 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"64390_CR6","doi-asserted-by":"publisher","first-page":"548","DOI":"10.3928\/1081597X-20150727-05","volume":"31","author":"T Moya","year":"2015","unstructured":"Moya, T. et al. Implantable collamer lens for myopia: Assessment 12 years after implantation. J. Refract. Surg. 31, 548\u2013556. https:\/\/doi.org\/10.3928\/1081597X-20150727-05 (2015).","journal-title":"J. Refract. Surg."},{"key":"64390_CR7","doi-asserted-by":"publisher","first-page":"532","DOI":"10.1016\/j.ajo.2013.11.006","volume":"157","author":"A Igarashi","year":"2014","unstructured":"Igarashi, A., Shimizu, K. & Kamiya, K. Eight-year follow-up of posterior chamber phakic intraocular lens implantation for moderate to high myopia. Am. J. Ophthalmol. 157, 532\u2013539. https:\/\/doi.org\/10.1016\/j.ajo.2013.11.006 (2014).","journal-title":"Am. J. Ophthalmol."},{"key":"64390_CR8","doi-asserted-by":"publisher","first-page":"1506","DOI":"10.1016\/j.ophtha.2009.12.013","volume":"117","author":"G Schmidinger","year":"2010","unstructured":"Schmidinger, G., Lackner, B., Pieh, S. & Skorpik, C. Long term changes in posterior chamber phakic intraocular collamer lens vaulting in myopic patients. Ophthalmology 117, 1506\u20131511. https:\/\/doi.org\/10.1016\/j.ophtha.2009.12.013 (2010).","journal-title":"Ophthalmology"},{"key":"64390_CR9","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1097\/j.jcrs.0000000000000146","volume":"46","author":"AS Trancon","year":"2020","unstructured":"Trancon, A. S., Manito, S. C., Sierra, O. T., Baptista, A. M. & Serra, P. M. Determining vault size in implantable collamer lenses: Preoperative anatomy and lens parameters. J. Cataract Refract. Surg. 46, 728\u2013736. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000146 (2020).","journal-title":"J. Cataract Refract. Surg."},{"key":"64390_CR10","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.ophtha.2011.07.047","volume":"119","author":"DH Lee","year":"2012","unstructured":"Lee, D. H., Choi, S. H., Chung, E. S. & Chung, T. Y. Correlation between preoperative biometry and posterior chamber phakic visian implantable collamer lens vaulting. Ophthalmology 119, 272\u2013277. https:\/\/doi.org\/10.1016\/j.ophtha.2011.07.047 (2012).","journal-title":"Ophthalmology"},{"key":"64390_CR11","doi-asserted-by":"publisher","first-page":"e0165469","DOI":"10.1371\/journal.pone.0165469","volume":"11","author":"S Senthil","year":"2016","unstructured":"Senthil, S. et al. Etiology and management of raised intraocular pressure following posterior chamber phakic intraocular lens implantation in myopic eyes. PLoS. One 11, e0165469. https:\/\/doi.org\/10.1371\/journal.pone.0165469 (2016).","journal-title":"PLoS. One"},{"key":"64390_CR12","doi-asserted-by":"publisher","first-page":"293","DOI":"10.4103\/0974-9233.194076","volume":"23","author":"NA AlSabaani","year":"2016","unstructured":"AlSabaani, N. A. et al. Causes of phakic implantable collamer lens explantation\/exchange at King Khaled Eye Specialist Hospital. Middle East Afr. J. Ophthalmol. 23, 293\u2013295. https:\/\/doi.org\/10.4103\/0974-9233.194076 (2016).","journal-title":"Middle East Afr. J. Ophthalmol."},{"key":"64390_CR13","doi-asserted-by":"publisher","first-page":"632","DOI":"10.2147\/OPTH.S111620","volume":"152","author":"T Kojima","year":"2012","unstructured":"Kojima, T. et al. Optimization of an implantable collamer lens sizing method using high frequency ultrasound biomicroscopy. Am. J. Ophthalmol. 152, 632\u2013637. https:\/\/doi.org\/10.2147\/OPTH.S111620 (2012).","journal-title":"Am. J. Ophthalmol."},{"key":"64390_CR14","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1016\/j.jcrs.2014.06.036","volume":"41","author":"QY Zeng","year":"2015","unstructured":"Zeng, Q. Y., Xie, X. L. & Chen, Q. Prevention and management of collagen copolymer phakic intraocular lens exchange: causes and surgical techniques. J. Cataract Refract. Surg. 41, 576\u2013584. https:\/\/doi.org\/10.1016\/j.jcrs.2014.06.036 (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"64390_CR15","doi-asserted-by":"publisher","first-page":"1807","DOI":"10.1007\/s00417-012-1957-0","volume":"250","author":"JF Alfonso","year":"2012","unstructured":"Alfonso, J. F. et al. Long-term evaluation of the central vault after phakic Collamer(R) lens (ICL) implantation using OCT. Graefes Arch. Clin. Exp. Ophthalmol. 250, 1807\u20131812. https:\/\/doi.org\/10.1007\/s00417-012-1957-0 (2012).","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"64390_CR16","doi-asserted-by":"publisher","first-page":"1245","DOI":"10.1016\/j.ophtha.2009.10.033","volume":"117","author":"A Lindland","year":"2010","unstructured":"Lindland, A., Heger, H., Kugelberg, M. & Zetterstrom, C. Vaulting of myopic and toric implantable collamer lenses during accommodation measured with Visante optical coherence tomography. Ophthalmology 117, 1245\u20131250. https:\/\/doi.org\/10.1016\/j.ophtha.2009.10.033 (2010).","journal-title":"Ophthalmology"},{"key":"64390_CR17","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1186\/s12886-017-0663-4","volume":"17","author":"SW Nam","year":"2017","unstructured":"Nam, S. W., Lim, D. H., Hyun, J., Chung, E. S. & Chung, T. Y. Buffering zone of implantable Collamer lens sizing in V4c. BMC. Ophthalmol. 17, 260. https:\/\/doi.org\/10.1186\/s12886-017-0663-4 (2017).","journal-title":"BMC. Ophthalmol."},{"key":"64390_CR18","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1186\/s12886-018-0783-5","volume":"18","author":"X Zhang","year":"2018","unstructured":"Zhang, X., Chen, X., Wang, X., Yuan, F. & Zhou, X. Analysis of intraocular positions of posterior implantable collamer lens by full-scale ultrasound biomicroscopy. BMC Ophthalmol. 18, 114. https:\/\/doi.org\/10.1186\/s12886-018-0783-5 (2018).","journal-title":"BMC Ophthalmol."},{"key":"64390_CR19","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.jcrs.2010.07.014","volume":"37","author":"PJ Dougherty","year":"2011","unstructured":"Dougherty, P. J. et al. Improving accuracy of phakic intraocular lens sizing using high-frequency ultrasound biomicroscopy. J. Cataract Refract. Surg. 37, 13\u201318. https:\/\/doi.org\/10.1016\/j.jcrs.2010.07.014 (2011).","journal-title":"J. Cataract Refract. Surg."},{"key":"64390_CR20","doi-asserted-by":"publisher","first-page":"632","DOI":"10.1016\/j.ajo.2011.06.031","volume":"153","author":"T Kojima","year":"2012","unstructured":"Kojima, T. et al. Optimization of an implantable collamer lens sizing method using high-frequency ultrasound biomicroscopy. Am. J. Ophthalmol. 153, 632\u2013637. https:\/\/doi.org\/10.1016\/j.ajo.2011.06.031 (2012).","journal-title":"Am. J. Ophthalmol."},{"key":"64390_CR21","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.2147\/OPTH.S111620","volume":"10","author":"M Packer","year":"2016","unstructured":"Packer, M. Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens. Clin. Ophthalmol. 10, 1059\u20131077. https:\/\/doi.org\/10.2147\/OPTH.S111620 (2016).","journal-title":"Clin. Ophthalmol."},{"key":"64390_CR22","doi-asserted-by":"publisher","first-page":"272","DOI":"10.3928\/1081597X-20220302-01.w","volume":"38","author":"DZ Reinstein","year":"2022","unstructured":"Reinstein, D. Z., Archer, T. J., Vida, R. S., Piparia, V. & Potter, J. G. New sizing parameters and model for predicting postoperative vault for the implantable collamer lens posterior chamber phakic intraocular lens. J. Refract. Surg. 38, 272\u2013279. https:\/\/doi.org\/10.3928\/1081597X-20220302-01.w (2022).","journal-title":"J. Refract. Surg."},{"key":"64390_CR23","doi-asserted-by":"publisher","first-page":"3139","DOI":"10.1167\/iovs.12-9776","volume":"53","author":"D Wang","year":"2012","unstructured":"Wang, D., Qi, M., He, M., Wu, L. & Lin, S. Ethnic difference of the anterior chamber area and volume and its association with angle width. Invest. Ophthalmol. Vis. Sci. 53, 3139\u20133144. https:\/\/doi.org\/10.1167\/iovs.12-9776 (2012).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"64390_CR24","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.ajo.2017.12.015.w","volume":"187","author":"T Nakamura","year":"2018","unstructured":"Nakamura, T., Isogai, N., Kojima, T., Yoshida, Y. & Sugiyama, Y. Implantable collamer lens sizing method based on swept-source anterior segment optical coherence tomography. Am. J. Ophthalmol. 187, 99\u2013107. https:\/\/doi.org\/10.1016\/j.ajo.2017.12.015.w (2018).","journal-title":"Am. J. Ophthalmol."},{"key":"64390_CR25","doi-asserted-by":"publisher","first-page":"742","DOI":"10.1097\/j.jcrs.0000000000000134","volume":"46","author":"T Nakamura","year":"2020","unstructured":"Nakamura, T., Isogai, N., Kojima, T., Yoshida, Y. & Sugiyama, Y. Optimization of implantable collamer lens sizing based on swept-source anterior segment optical coherence tomography. J. Cataract Refract. Surg. 46, 742\u2013748. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000134 (2020).","journal-title":"J. Cataract Refract. Surg."},{"key":"64390_CR26","doi-asserted-by":"publisher","first-page":"1616","DOI":"10.1016\/j.jcrs.2014.12.051.w","volume":"41","author":"BE Malyugin","year":"2015","unstructured":"Malyugin, B. E., Shpak, A. A. & Pokrovskiy, D. F. Posterior chamber phakic intraocular lens sizing based on iris pigment layer measurements by anterior segment optical coherence tomography. J. Cataract Refract. Surg. 41, 1616\u20131622. https:\/\/doi.org\/10.1016\/j.jcrs.2014.12.051.w (2015).","journal-title":"J. Cataract Refract. Surg."},{"key":"64390_CR27","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1016\/j.jcrs.2019.02.020","volume":"45","author":"A Igarashi","year":"2019","unstructured":"Igarashi, A., Shimizu, K., Kato, S. & Kamiya, K. Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography. J. Cataract Refract. Surg. 45, 1099\u20131104. https:\/\/doi.org\/10.1016\/j.jcrs.2019.02.020 (2019).","journal-title":"J. Cataract Refract. Surg."},{"key":"64390_CR28","doi-asserted-by":"publisher","first-page":"636","DOI":"10.3928\/1081597X-20210610-06","volume":"37","author":"A Igarashi","year":"2021","unstructured":"Igarashi, A., Shimizu, K. & Kato, S. Assessment of the vault after implantable collamer lens implantation using the KS formula. J. Refract. Surg. 37, 636\u2013641. https:\/\/doi.org\/10.3928\/1081597X-20210610-06 (2021).","journal-title":"J. Refract. Surg."},{"key":"64390_CR29","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1186\/s12886-018-0835-x","volume":"18","author":"H Lee","year":"2018","unstructured":"Lee, H. et al. Analysis of pre-operative factors affecting range of optimal vaulting after implantation of 12.6-mm V4c implantable collamer lens in myopic eyes. BMC Ophthalmol. 18, 163. https:\/\/doi.org\/10.1186\/s12886-018-0835-x (2018).","journal-title":"BMC Ophthalmol."},{"key":"64390_CR30","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1186\/s12886-016-0336-8","volume":"16","author":"X Chen","year":"2016","unstructured":"Chen, X., Miao, H., Naidu, R. K., Wang, X. & Zhou, X. Comparison of early changes in and factors affecting vault following posterior chamber phakic implantable collamer lens implantation without and with a central hole (ICL V4 and ICL V4c). BMC Ophthalmol. 16, 161. https:\/\/doi.org\/10.1186\/s12886-016-0336-8 (2016).","journal-title":"BMC Ophthalmol."},{"key":"64390_CR31","doi-asserted-by":"publisher","first-page":"519","DOI":"10.3760\/cma.j.cn112142-20201222-00837","volume":"57","author":"QJ Zhu","year":"2021","unstructured":"Zhu, Q. J. et al. Prediction of the vaulting after posterior chamber intraocular lens implantation. Zhonghua Yan Ke Za Zhi. 57, 519\u2013525. https:\/\/doi.org\/10.3760\/cma.j.cn112142-20201222-00837 (2021).","journal-title":"Zhonghua Yan Ke Za Zhi."},{"key":"64390_CR32","doi-asserted-by":"publisher","first-page":"4485","DOI":"10.2147\/OPTH.S330879","volume":"15","author":"DZ Reinstein","year":"2021","unstructured":"Reinstein, D. Z., Vida, R. S. & Archer, T. J. Visual Outcomes, Footplate position and vault achieved with the visian implantable collamer lens for myopic astigmatism. Clin. Ophthalmol. 15, 4485\u20134497. https:\/\/doi.org\/10.2147\/OPTH.S330879 (2021).","journal-title":"Clin. Ophthalmol."},{"key":"64390_CR33","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1097\/APO.0000000000000235","volume":"5","author":"X Wang","year":"2016","unstructured":"Wang, X. & Zhou, X. Update on treating high myopia with implantable collamer lenses. Asia Pac. J. Ophthalmol. 5, 445\u2013449. https:\/\/doi.org\/10.1097\/APO.0000000000000235 (2016).","journal-title":"Asia Pac. J. Ophthalmol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-64390-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-64390-0","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-64390-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,10]],"date-time":"2024-06-10T13:07:02Z","timestamp":1718024822000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-64390-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,10]]},"references-count":33,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["64390"],"URL":"https:\/\/doi.org\/10.1038\/s41598-024-64390-0","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,10]]},"assertion":[{"value":"14 December 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 June 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"13296"}}