{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T16:56:57Z","timestamp":1787849817424,"version":"build-2784847793"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,6,16]],"date-time":"2024-06-16T00:00:00Z","timestamp":1718496000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,6,16]],"date-time":"2024-06-16T00:00:00Z","timestamp":1718496000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"The National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["No. 82160208"],"award-info":[{"award-number":["No. 82160208"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"name":"The science and technology foundation of Guizhou Province","award":["ZK [2024- general 334]"],"award-info":[{"award-number":["ZK [2024- general 334]"]}]},{"name":"The Science and Technology Fund of the Health and Health Commission of Guizhou Province","award":["gzwkj2022-158"],"award-info":[{"award-number":["gzwkj2022-158"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This study aimed to compare the differences and characteristics of white-to-white (WTW) values obtained before V4c implantation using triple person-times caliper, IOL-Master 700, Pentacam HR, and UBM, and to assess their correlation with vaulting. A total of 930 myopia patients (1842 eyes) who were interested in undergoing ICL surgery were assessed before the procedure using various instruments. The WTW measurements were obtained using a triple person-times caliper, Pentacam HR, and IOL-Master 700, whereas the angle-to-angle (ATA) measurements were obtained using UBM. The size of the ICL was subsequently calculated using triple person-times caliper measurements. The vault of the ICL was assessed using Pentacam HR three months after the surgery. The WTW was determined to be 11.30\u2009\u00b1\u20090.29\u00a0mm, 11.43\u2009\u00b1\u20090.29\u00a0mm, and11.86\u2009\u00b1\u20090.38\u00a0mm, respectively, using the triple person-times caliper, Pentacam HR, and IOL-Master 700. The measurement of ATA was 11.57\u2009\u00b1\u20090.51\u00a0mm, as done by UBM. The ICL vault was measured to be 400.97\u2009\u00b1\u2009198.46\u00a0\u00b5m when examined with Pentacam HR three monthsafter the procedure. The linear regression analyses of ICL size and WTW of triple person-times caliper, ICL vault and WTW were (R\u2009=\u20090.703, p\u2009&lt;\u20090.001; R\u2009=\u20090.0969, p\u2009&lt;\u20090.001) respectively. The highest correlation was found between IOL-Master and Pentacam HR (r\u2009=\u20090.766, p\u2009=\u20090.000). The lowest correlation was found between UBM and Pentacam HR (r\u2009=\u20090.358, p\u2009=\u20090.002). Bland\u2013Altman analysis showed that the 95% limits of agreement (LoA) were the triple person-times caliper and Pentacam HR (\u2013\u00a00.573, 0.298) and the triple person-times caliper and UBM (\u2013\u00a01.15, \u2013\u00a00.605). This indicated a strong agreement between the triple person-times caliper and Pentacam HR and a lack of agreement between the triple person-times caliper and UBM. Triple person-times caliper measurements offer excellent maneuverability, practicality, and reliable outcomes for determining ICL vaults. Measurements obtained using the triple-person caliper were less differece than those obtained using the Pentacam HR.<\/jats:p>","DOI":"10.1038\/s41598-024-64647-8","type":"journal-article","created":{"date-parts":[[2024,6,16]],"date-time":"2024-06-16T07:01:28Z","timestamp":1718521288000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["The comparison of white-to-white via triple person-times caliper measuring and machine-measuring in V4c implantable collamer lens implantation"],"prefix":"10.1038","volume":"14","author":[{"given":"Ting-Ting","family":"Dan","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tai-Xiang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zong-Ze","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ceng-Peng","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fa-Yuan","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,6,16]]},"reference":[{"key":"64647_CR1","doi-asserted-by":"publisher","first-page":"969","DOI":"10.2147\/OpTH.S379856","volume":"17","author":"T Wannapanich","year":"2023","unstructured":"Wannapanich, T. et al. Intraocular implantable collamer lens with a central hole implantation: Safety, efficacy, and patient outcomes. Clin. Ophthalmol. Auckl. N. Z. 17, 969\u2013980. https:\/\/doi.org\/10.2147\/OpTH.S379856 (2023).","journal-title":"Clin. Ophthalmol. Auckl. N. Z."},{"issue":"12","key":"64647_CR2","doi-asserted-by":"publisher","first-page":"2168","DOI":"10.1016\/j.jcrs.2010.10.007","volume":"36","author":"T Kohnen","year":"2010","unstructured":"Kohnen, T., Kook, D., Morral, M. & G\u00fcell, J. L. Phakic intraocular lenses: Part 2: Results and complications. J. Cataract Refract. Surg. 36(12), 2168\u20132194 (2010).","journal-title":"J. Cataract Refract. Surg."},{"issue":"10","key":"64647_CR3","doi-asserted-by":"publisher","first-page":"765","DOI":"10.3928\/1081597X-20110617-01","volume":"27","author":"P Fernandes","year":"2011","unstructured":"Fernandes, P. et al. Implantable collamer posterior chamber intraocular lenses: A review of potential complications. J. Refract. Surg. 27(10), 765\u2013776 (2011).","journal-title":"J. Refract. Surg."},{"issue":"6","key":"64647_CR4","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1016\/j.survophthal.2005.08.011","volume":"50","author":"CF Lovisolo","year":"2005","unstructured":"Lovisolo, C. F. & Reinstein, D. Z. Phakic intraocular lenses. Surv. Ophthalmol. 50(6), 549\u2013587 (2005).","journal-title":"Surv. Ophthalmol."},{"issue":"12","key":"64647_CR5","doi-asserted-by":"publisher","first-page":"2094","DOI":"10.1016\/j.jcrs.2012.07.039","volume":"38","author":"N Popp","year":"2012","unstructured":"Popp, N., Hirnschall, N., Maedel, S. & Findl, O. Evaluation of 4 corneal astigmatic marking methods. J. Cataract Refract. Surg. 38(12), 2094\u20132099. https:\/\/doi.org\/10.1016\/j.jcrs.2012.07.039 (2012) (Epub 2012 Oct 23).","journal-title":"J. Cataract Refract. Surg."},{"issue":"9","key":"64647_CR6","doi-asserted-by":"publisher","first-page":"1982","DOI":"10.1016\/j.jcrs.2003.10.041","volume":"30","author":"L Werner","year":"2004","unstructured":"Werner, L. et al. Correlation between different measurements within the eye relative to phakic intraocular lens implantation. J. Cataract Refract. Surg. 30(9), 1982\u20131988 (2004).","journal-title":"J. Cataract Refract. Surg."},{"issue":"1","key":"64647_CR7","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.jcrs.2007.10.010","volume":"34","author":"DP Pi\u00f1ero","year":"2008","unstructured":"Pi\u00f1ero, D. P., Plaza Puche, A. B. & Ali\u00f3, J. L. Corneal diameter measurements by corneal topography and angle-to-angle measurements by optical coherence tomography: Evaluation of equivalence. J. Cataract Refract. Surg. 34(1), 126\u2013131. https:\/\/doi.org\/10.1016\/j.jcrs.2007.10.010 (2008).","journal-title":"J. Cataract Refract. Surg."},{"issue":"1","key":"64647_CR8","doi-asserted-by":"publisher","first-page":"30","DOI":"10.3928\/1081597X-20121210-02","volume":"29","author":"DZ Reinstein","year":"2013","unstructured":"Reinstein, D. Z., Lovisolo, C. F., Archer, T. J. & Gobbe, M. Comparison of postoperative vault height predictability using white-to-white or sulcus diameter-based sizing for the visian implantable collamer lens. J. Refract. Surg. 29(1), 30\u201335 (2013).","journal-title":"J. Refract. Surg."},{"issue":"11","key":"64647_CR9","doi-asserted-by":"publisher","first-page":"6847","DOI":"10.1167\/iovs.15-17228","volume":"56","author":"K Erb-Eigner","year":"2015","unstructured":"Erb-Eigner, K. et al. Eye and Vision predicting lens diameter: Ocular biometry with high-resolution MRI. Invest. Ophthalmol. Vis. Sci. 56(11), 6847\u20136854 (2015).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"issue":"3","key":"64647_CR10","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1016\/j.joco.2017.11.011","volume":"30","author":"SJ Hashemian","year":"2017","unstructured":"Hashemian, S. J. et al. Adjustment formulae to improve the correlation of white-to-white measurement with direct measurement of the ciliary sulcus diameter by ultrasound biomicroscopy. J. Curr. Ophthalmol. 30(3), 217\u2013222 (2017).","journal-title":"J. Curr. Ophthalmol."},{"key":"64647_CR11","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.ajo.2017.12.015","volume":"187","author":"T Nakamura","year":"2018","unstructured":"Nakamura, T., Isogai, N., Kojima, T., Yoshida, Y. & Sugiyama, Y. Implantable collamer lens sizing method based on swept-source anterior segment optical coherence tomography. Am. J. Ophthalmol. 187, 99\u2013107 (2018).","journal-title":"Am. J. Ophthalmol."},{"issue":"3","key":"64647_CR12","doi-asserted-by":"publisher","first-page":"661","DOI":"10.1007\/s10792-018-0859-5","volume":"39","author":"M Ghoreishi","year":"2019","unstructured":"Ghoreishi, M., Abdi-Shahshahani, M., Peyman, A. & Pourazizi, M. A model for predicting sulcus-to-sulcus diameter in posterior chamber phakic intraocular lens candidates: Correlation between ocular biometric parameters. Int. Ophthalmol. 39(3), 661\u2013666 (2019).","journal-title":"Int. Ophthalmol."},{"issue":"1","key":"64647_CR13","first-page":"95","volume":"46","author":"C Bruner","year":"2020","unstructured":"Bruner, C., Skanchy, D. F., Wooten, J. P., Chuang, A. Z. & Kim, G. Anterior chamber lens sizing: Comparison of white-to-white and scleral spur-to-scleral spurmethods. J. Cataract Refract. Surg. 46(1), 95\u2013101 (2020).","journal-title":"J. Cataract Refract. Surg."},{"key":"64647_CR14","unstructured":"STAAR Surgical. STAAR Surgical Investor presentation (2022, accessed 29 Oct 2022). https:\/\/investors.staar.com\/home\/default.aspx."},{"key":"64647_CR15","doi-asserted-by":"publisher","first-page":"518","DOI":"10.1016\/j.jcjo.2017.11.018","volume":"53","author":"HV Gimbel","year":"2018","unstructured":"Gimbel, H. V., LeClair, B. M., Jabo, B. & Marzouk, H. Incidence of implantable Collamer lens-induced cataract. Can. J. Ophthalmol. 53, 518\u2013522 (2018).","journal-title":"Can. J. Ophthalmol."},{"key":"64647_CR16","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.2147\/OpTH.S111620","volume":"10","author":"M Packer","year":"2016","unstructured":"Packer, M. Meta-analysis and review: Effectiveness, safety, and central port design of the intraocular collamer lens. Clin. Ophthalmol. Auckl. N. Z. 10, 1059\u20131077. https:\/\/doi.org\/10.2147\/OpTH.S111620 (2016).","journal-title":"Clin. Ophthalmol. Auckl. N. Z."},{"issue":"6","key":"64647_CR17","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1016\/j.jfo.2011.06.006","volume":"35","author":"M Le-Loir","year":"2012","unstructured":"Le-Loir, M. & Cochener, B. R\u00e9sultats \u00e0 long terme de l\u2019implantation phaque de chambre post\u00e9rieure pour la correction des am\u00e9tropies fortes [Long-term results of posterior chamber phakic intraocular lens implantation for correction of high ametropia]. J. Fr. Ophtalmol. 35(6), 402\u2013411. https:\/\/doi.org\/10.1016\/j.jfo.2011.06.006 (2012) (Epub 2012 Jan 16).","journal-title":"J. Fr. Ophtalmol."},{"issue":"1","key":"64647_CR18","doi-asserted-by":"publisher","first-page":"199","DOI":"10.1186\/s12886-021-01963-x","volume":"21","author":"Q-J Zhu","year":"2021","unstructured":"Zhu, Q.-J. et al. Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation. BMC Ophthalmol. 21(1), 199. https:\/\/doi.org\/10.1186\/s12886-021-01963-x (2021).","journal-title":"BMC Ophthalmol."},{"key":"64647_CR19","doi-asserted-by":"publisher","first-page":"177","DOI":"10.3928\/1081597X-20190204-01","volume":"35","author":"F Gonzalez-Lopez","year":"2019","unstructured":"Gonzalez-Lopez, F. et al. Determining the potential role of crystalline lens rise in vaulting in posterior chamber phakic collamer lens surgery for correction of myopia. J. Refract. Surg. 35, 177\u2013183 (2019).","journal-title":"J. Refract. Surg."},{"key":"64647_CR20","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1016\/j.jcrs.2019.02.020","volume":"45","author":"A Igarashi","year":"2019","unstructured":"Igarashi, A., Shimizu, K., Kato, S. & Kamiya, K. predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography. J. Cataract Refract. Surg. 45, 1099\u20131104 (2019).","journal-title":"J. Cataract Refract. Surg."},{"key":"64647_CR21","doi-asserted-by":"publisher","first-page":"1586","DOI":"10.4103\/ijo.IJO_2217_21","volume":"70","author":"JA Calvo-Sanz","year":"2022","unstructured":"Calvo-Sanz, J. A., Poyales, F., Zhou, Y., Arias-puente, A. & Garz\u00f3n, N. Agreement between the biometric measurements used to calculate the size of the implantable collamer lenses measured with four different technologies. Indian J. Ophthalmol. 70, 1586\u20131592 (2022).","journal-title":"Indian J. Ophthalmol."},{"issue":"7","key":"64647_CR22","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.18240\/ijo.2016.07.20","volume":"9","author":"A Dom\u00ednguez-Vicent","year":"2016","unstructured":"Dom\u00ednguez-Vicent, A. et al. Device interchangeability on anterior chamber depth and white-to-white measurements: A thorough literature review. Int. J. Ophthalmol. 9(7), 1057\u20131065. https:\/\/doi.org\/10.18240\/ijo.2016.07.20 (2016).","journal-title":"Int. J. Ophthalmol."},{"key":"64647_CR23","first-page":"11","volume":"41","author":"Y Shao","year":"2023","unstructured":"Shao, Y., Yi, X. & Hu, L. Expert consensus on standardized practice for preoperative examination for posterior chamber phakic intraocular lens implantation 2003. Chin. J. Exp. Ophthalmol. 41, 11 (2023).","journal-title":"Chin. J. Exp. Ophthalmol."},{"issue":"4","key":"64647_CR24","first-page":"701","volume":"19","author":"HZ Yin","year":"2019","unstructured":"Yin, H. Z. Comparision the differences of WTW obtained by Wavelight, IOL Master, LS900, AS-OCT and the triple person-times caliper before ICL implantation. Guoji Yanke Zazhi Int. Eye Sci. 19(4), 701\u2013703 (2019).","journal-title":"Guoji Yanke Zazhi Int. Eye Sci."},{"issue":"1","key":"64647_CR25","first-page":"168","volume":"20","author":"XL Ma","year":"2020","unstructured":"Ma, X. L. et al. Comparison of three instruments for measuring corneal horizontal diameter. Guoji Yanke Zazhi Int. Eye Sci. 20(1), 168\u2013170 (2020).","journal-title":"Guoji Yanke Zazhi Int. Eye Sci."},{"key":"64647_CR26","doi-asserted-by":"publisher","first-page":"1516395","DOI":"10.1155\/2017\/1516395","volume":"2017","author":"S Jung","year":"2017","unstructured":"Jung, S. et al. Comparison of repeatability and agreement between swept\u2014source optical biometry and dual\u2014scheimpflug topography. J. Ophthalmol. 2017, 1516395 (2017).","journal-title":"J. Ophthalmol."},{"issue":"3","key":"64647_CR27","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1111\/cxo.12247","volume":"98","author":"A Dominguez-Vicent","year":"2015","unstructured":"Dominguez-Vicent, A. et al. Interchangeability among five devices that measure anterior eye distances. Clin. Exp. Optom. 98(3), 254\u2013262 (2015).","journal-title":"Clin. Exp. Optom."},{"issue":"3","key":"64647_CR28","doi-asserted-by":"publisher","first-page":"202","DOI":"10.5301\/ejo.5000524","volume":"25","author":"KM Sayed","year":"2015","unstructured":"Sayed, K. M. & Alsamman, A. H. Interchangeability between Pentacam HR and IOLMaster in phakic intraocular lens calculation. Eur. J. Ophthalmol. 25(3), 202\u2013207 (2015).","journal-title":"Eur. J. Ophthalmol."},{"issue":"11","key":"64647_CR29","doi-asserted-by":"publisher","first-page":"1373","DOI":"10.1097\/ICO.0000000000001300","volume":"36","author":"R Salouti","year":"2017","unstructured":"Salouti, R. et al. Agreement of corneal diameter measurements obtained by a swept-source biometer and a scheimpflug-based topographer. Cornea 36(11), 1373\u20131376. https:\/\/doi.org\/10.1097\/ICO.0000000000001300 (2017).","journal-title":"Cornea"},{"issue":"3","key":"64647_CR30","doi-asserted-by":"publisher","first-page":"598","DOI":"10.3390\/diagnostics12030598","volume":"12","author":"J Dong","year":"2022","unstructured":"Dong, J. et al. Comparison study of the two biometers based on swept-source optical coherence tomography technology. Diagn. Basel Switzerl. 12(3), 598. https:\/\/doi.org\/10.3390\/diagnostics12030598 (2022).","journal-title":"Diagn. Basel Switzerl."},{"issue":"6","key":"64647_CR31","first-page":"1031","volume":"19","author":"SS Tao","year":"2019","unstructured":"Tao, S. S. et al. Study on the correlation between horizontal corneal diameter and anterior chamber diameter and ciliary sulcus diameter. Guoji Yanke Zazhi Int. Eye Sci. 19(6), 1031\u20131034 (2019).","journal-title":"Guoji Yanke Zazhi Int. Eye Sci."},{"issue":"5","key":"64647_CR32","doi-asserted-by":"publisher","first-page":"1586","DOI":"10.4103\/ijo.IJO_2217_21","volume":"70","author":"JA Calvo-Sanz","year":"2022","unstructured":"Calvo-Sanz, J. A. et al. Agreement between the biometric measurements used to calculate the size of the implantable collamer lenses measured with four different technologies. Indian J. Ophthalmol. 70(5), 1586\u20131592. https:\/\/doi.org\/10.4103\/ijo.IJO_2217_21 (2022).","journal-title":"Indian J. Ophthalmol."},{"issue":"4","key":"64647_CR33","doi-asserted-by":"publisher","first-page":"624","DOI":"10.1016\/j.jcrs.2013.02.020","volume":"39","author":"N Visser","year":"2013","unstructured":"Visser, N., Bauer, N. J. & Nuijts, R. M. Toric intraocular lenses: Historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications. J. Cataract Refract. Surg. 39(4), 624\u2013637 (2013).","journal-title":"J. Cataract Refract. Surg."},{"issue":"10","key":"64647_CR34","doi-asserted-by":"publisher","first-page":"1190","DOI":"10.1097\/j.jcrs.0000000000000950","volume":"48","author":"R Wei","year":"2022","unstructured":"Wei, R. et al. Factors leading to realignment or exchange after implantable collamer lens implantation in 10 258 eyes. J. Cataract Refract. Surg. 48(10), 1190\u20131196. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000000950 (2022) (Epub 2022 Mar 30).","journal-title":"J. Cataract Refract. Surg."},{"issue":"4","key":"64647_CR35","doi-asserted-by":"publisher","first-page":"293","DOI":"10.4103\/0974-9233.194076","volume":"23","author":"NA AlSabaani","year":"2016","unstructured":"AlSabaani, N. A. et al. Causes of phakic implantable collamer lens explantation\/exchange at King Khaled eye specialist hospital. Middle East Afr. J. Ophthalmol. 23(4), 293\u2013295. https:\/\/doi.org\/10.4103\/0974-9233.194076 (2016).","journal-title":"Middle East Afr. J. Ophthalmol."},{"key":"64647_CR36","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1136\/bjophthalmol-2017-310164","volume":"102","author":"K Kamiya","year":"2018","unstructured":"Kamiya, K. et al. Posterior chamber phakic intraocular lens implantation: Comparative, multicentre study in 351 eyes with low-to-moderate or high myopia. Br. J. Ophthalmol. 102, 177\u2013181 (2018).","journal-title":"Br. J. Ophthalmol."},{"key":"64647_CR37","doi-asserted-by":"publisher","first-page":"2427","DOI":"10.2147\/OPTH.S188785","volume":"12","author":"M Packer","year":"2018","unstructured":"Packer, M. The implantable collamer lens with a central port: Review of the literature. Clin. Ophthalmol. 12, 2427\u20132438 (2018).","journal-title":"Clin. Ophthalmol."},{"issue":"4","key":"64647_CR38","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1097\/j.jcrs.0000000000001134","volume":"49","author":"W Tan","year":"2023","unstructured":"Tan, W. et al. Characteristics and factors associated with the position of the haptic after ICL V4C implantation. J. Cataract Refract. Surg. 49(4), 416\u2013422. https:\/\/doi.org\/10.1097\/j.jcrs.0000000000001134 (2023).","journal-title":"J. Cataract Refract. Surg."},{"issue":"2","key":"64647_CR39","first-page":"377","volume":"21","author":"J Wang","year":"2021","unstructured":"Wang, J. et al. Effect of crystalline lens rise on the vault after implantation of phakic posterior chamber implantable collamer lens. Guoji Yanke Zazhi Int. Eye Sci. 21(2), 377\u2013381 (2021).","journal-title":"Guoji Yanke Zazhi Int. Eye Sci."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-64647-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-64647-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-64647-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,6,16]],"date-time":"2024-06-16T07:02:12Z","timestamp":1718521332000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-64647-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,16]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["64647"],"URL":"https:\/\/doi.org\/10.1038\/s41598-024-64647-8","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-4213265\/v1","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,16]]},"assertion":[{"value":"3 April 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 June 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 June 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"13878"}}