{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T23:55:05Z","timestamp":1783727705571,"version":"3.55.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T00:00:00Z","timestamp":1722297600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T00:00:00Z","timestamp":1722297600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-024-68349-z","type":"journal-article","created":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T18:32:34Z","timestamp":1722364354000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["The feasibility and accuracy of the method for selecting the optimal size of double-lumen tube in thoracic surgery: a prospective, randomized controlled trial"],"prefix":"10.1038","volume":"14","author":[{"given":"Guangying","family":"Cui","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng","family":"Chi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shujuan","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhuo","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,7,30]]},"reference":[{"key":"68349_CR1","doi-asserted-by":"publisher","first-page":"441","DOI":"10.12968\/hmed.2019.80.8.441","volume":"80","author":"T Tikka","year":"2019","unstructured":"Tikka, T. & Hilmi, O. J. Upper airway tract complications of endotracheal intubation. Br. J. Hosp. Med. 80, 441\u2013447. https:\/\/doi.org\/10.12968\/hmed.2019.80.8.441 (2019).","journal-title":"Br. J. Hosp. Med."},{"key":"68349_CR2","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1111\/j.1600-9657.2010.00955.x","volume":"27","author":"N Adolphs","year":"2011","unstructured":"Adolphs, N. et al. Dentoalveolar injury related to general anaesthesia: A 14 years review and a statement from the surgical point of view based on a retrospective analysis of the documentation of a university hospital. Dent. Traumatol. 27, 10\u201314. https:\/\/doi.org\/10.1111\/j.1600-9657.2010.00955.x (2011).","journal-title":"Dent. Traumatol."},{"key":"68349_CR3","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1213\/01.ane.0000255171.94527.c7","volume":"104","author":"A Roscoe","year":"2007","unstructured":"Roscoe, A., Kanellakos, G. W., McRae, K. & Slinger, P. Pressures exerted by endobronchial devices. Anesth. Analg. 104, 655\u2013658. https:\/\/doi.org\/10.1213\/01.ane.0000255171.94527.c7 (2007).","journal-title":"Anesth. Analg."},{"key":"68349_CR4","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2018-026606","author":"E Kim","year":"2019","unstructured":"Kim, E., Kim, I.-Y. & Byun, S.-H. Effect of lateral positioning on the bronchial cuff pressure of a left-sided double-lumen endotracheal tube during thoracic surgery: Study protocol for a prospective observational study. BMJ Open https:\/\/doi.org\/10.1136\/bmjopen-2018-026606 (2019).","journal-title":"BMJ Open"},{"key":"68349_CR5","doi-asserted-by":"publisher","first-page":"954","DOI":"10.1053\/j.jvca.2016.03.126","volume":"30","author":"J Spaeth","year":"2016","unstructured":"Spaeth, J. et al. Characteristics of double-lumen tubes determine bronchial airway pressure. J. Cardiothorac. Vasc. Anesth. 30, 954\u2013960. https:\/\/doi.org\/10.1053\/j.jvca.2016.03.126 (2016).","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"68349_CR6","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics12123162","author":"T-R Chang","year":"2022","unstructured":"Chang, T.-R., Yuan, M.-K., Pan, S.-F., Chuang, C.-C. & So, E. C. Double-lumen endotracheal tube\u2014predicting insertion depth and tube size based on patient\u2019s chest X-ray Image data and 4 other body parameters. Diagnostics https:\/\/doi.org\/10.3390\/diagnostics12123162 (2022).","journal-title":"Diagnostics"},{"key":"68349_CR7","doi-asserted-by":"publisher","DOI":"10.4103\/sja.sja_192_21","author":"A Eldawlatly","year":"2021","unstructured":"Eldawlatly, A. Double lumen tube: Size and insertion depth. Saudi J. Anaesth. https:\/\/doi.org\/10.4103\/sja.sja_192_21 (2021).","journal-title":"Saudi J. Anaesth."},{"key":"68349_CR8","doi-asserted-by":"publisher","first-page":"890","DOI":"10.1053\/j.jvca.2013.05.029","volume":"28","author":"D Kim","year":"2014","unstructured":"Kim, D., Son, J.-S., Ko, S., Jeong, W. & Lim, H. Measurements of the length and diameter of main bronchi on three-dimensional images in Asian adult patients in comparison with the height of patients. J. Cardiothorac. Vasc. Anesth. 28, 890\u2013895. https:\/\/doi.org\/10.1053\/j.jvca.2013.05.029 (2014).","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"68349_CR9","doi-asserted-by":"publisher","DOI":"10.4103\/aca.ACA_93_19","author":"B Hierlmeier","year":"2021","unstructured":"Hierlmeier, B., Nguyen, R., Kurnutala, L. & Tucci, M. Comparison of different size left-sided double-lumen tubes for thoracic surgery. Ann. Cardiac Anaesth. https:\/\/doi.org\/10.4103\/aca.ACA_93_19 (2021).","journal-title":"Ann. Cardiac Anaesth."},{"key":"68349_CR10","doi-asserted-by":"publisher","DOI":"10.4081\/monaldi.2023.2700","author":"E Gupta","year":"2023","unstructured":"Gupta, E. et al. Comparison of lung ultrasound technique <em>versus<\/em> clinical method to evaluate the accuracy of size and placement of left endobronchial double lumen tube in patients undergoing elective thoracic surgery: A prospective observational study. Monaldi Arch. Chest Dis. https:\/\/doi.org\/10.4081\/monaldi.2023.2700 (2023).","journal-title":"Monaldi Arch. Chest Dis."},{"key":"68349_CR11","doi-asserted-by":"publisher","first-page":"111136","DOI":"10.1016\/j.jclinane.2023.111136","volume":"88","author":"T Nakanishi","year":"2023","unstructured":"Nakanishi, T. et al. Combined use of the ProSeal laryngeal mask airway and a bronchial blocker vs. a double-lumen endobronchial tube in thoracoscopic surgery: A randomized controlled trial. J. Clin. Anesth. 88, 111136. https:\/\/doi.org\/10.1016\/j.jclinane.2023.111136 (2023).","journal-title":"J. Clin. Anesth."},{"key":"68349_CR12","doi-asserted-by":"publisher","first-page":"272","DOI":"10.4103\/sja.sja_78_21","volume":"15","author":"L Szegedi","year":"2021","unstructured":"Szegedi, L., Huybrechts, I. & Tuna, T. Lung separation in adult thoracic anesthesia. Saudi J. Anaesth. 15, 272. https:\/\/doi.org\/10.4103\/sja.sja_78_21 (2021).","journal-title":"Saudi J. Anaesth."},{"key":"68349_CR13","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1016\/s1053-0770(03)00058-2","volume":"17","author":"P Slinger","year":"2003","unstructured":"Slinger, P. A view of and through double-lumen tubes. J. Cardiothorac. Vasc. Anesth. 17, 287\u2013288. https:\/\/doi.org\/10.1016\/s1053-0770(03)00058-2 (2003).","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"68349_CR14","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1053\/j.jvca.2017.11.029","volume":"32","author":"L Shiqing","year":"2018","unstructured":"Shiqing, L., Wenxu, Q., Jin, Z. & Youjing, D. The combination of diameters of cricoid ring and left main bronchus for selecting the \u201cbest fit\u201d double-lumen tube. J. Cardiothorac. Vasc. Anesth. 32, 869\u2013876. https:\/\/doi.org\/10.1053\/j.jvca.2017.11.029 (2018).","journal-title":"J. Cardiothorac. Vasc. Anesth."},{"key":"68349_CR15","doi-asserted-by":"publisher","first-page":"612","DOI":"10.3389\/fmed.2021.657612","volume":"8","author":"C Zhang","year":"2021","unstructured":"Zhang, C. et al. Prediction of left double-lumen tube size by measurement of cricoid cartilage transverse diameter by ultrasound and CT multi-planar reconstruction. Front. Med. 8, 612. https:\/\/doi.org\/10.3389\/fmed.2021.657612 (2021).","journal-title":"Front. Med."},{"key":"68349_CR16","doi-asserted-by":"publisher","first-page":"3903","DOI":"10.21037\/jtd-22-451","volume":"14","author":"P Palaczynski","year":"2022","unstructured":"Palaczynski, P. et al. A randomized comparison between the VivaSight double-lumen tube and standard double-lumen tube intubation in thoracic surgery patients. J. Thorac. Dis. 14, 3903\u20133914. https:\/\/doi.org\/10.21037\/jtd-22-451 (2022).","journal-title":"J. Thorac. Dis."},{"key":"68349_CR17","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1093\/bja\/aev414","volume":"116","author":"JH Seo","year":"2016","unstructured":"Seo, J. H., Cho, C. W., Hong, D. M., Jeon, Y. & Bahk, J. H. The effects of thermal softening of double-lumen endobronchial tubes on postoperative sore throat, hoarseness and vocal cord injuries: A prospective double-blind randomized trial. Br. J. Anaesth. 116, 282\u2013288. https:\/\/doi.org\/10.1093\/bja\/aev414 (2016).","journal-title":"Br. J. Anaesth."},{"key":"68349_CR18","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1093\/bja\/aet203","volume":"111","author":"JH Seo","year":"2013","unstructured":"Seo, J. H. et al. Comparison of techniques for double-lumen endobronchial intubation: 90\u00b0 or 180\u00b0 rotation during advancement through the glottis. Br. J. Anaesth. 111, 812\u2013817. https:\/\/doi.org\/10.1093\/bja\/aet203 (2013).","journal-title":"Br. J. Anaesth."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-68349-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-68349-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-68349-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,30]],"date-time":"2024-07-30T18:33:23Z","timestamp":1722364403000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-68349-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,7,30]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["68349"],"URL":"https:\/\/doi.org\/10.1038\/s41598-024-68349-z","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,7,30]]},"assertion":[{"value":"15 April 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 July 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 July 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"17539"}}