{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,4]],"date-time":"2026-10-04T20:04:47Z","timestamp":1791144287676,"version":"4.1.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,10,13]],"date-time":"2024-10-13T00:00:00Z","timestamp":1728777600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,10,13]],"date-time":"2024-10-13T00:00:00Z","timestamp":1728777600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-024-73299-7","type":"journal-article","created":{"date-parts":[[2024,10,13]],"date-time":"2024-10-13T17:01:48Z","timestamp":1728838908000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Comparative analysis of two double-plate fixation techniques for intercondylar fractures of the distal humerus"],"prefix":"10.1038","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1895-473X","authenticated-orcid":false,"given":"Sami","family":"Bahroun","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hamdi","family":"Grami","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed Samih","family":"Kacem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ala","family":"Aloui","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zied","family":"Jlalia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed Samir","family":"Daghfous","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,10,13]]},"reference":[{"key":"73299_CR1","doi-asserted-by":"publisher","unstructured":"Hani, R. et al. 2017 Surgical treatment of the humeral pallet fractures in adults. Pan Afr. Med. J. 26 79. https:\/\/doi.org\/10.11604\/pamj.2017.26.79.10781","DOI":"10.11604\/pamj.2017.26.79.10781"},{"issue":"5","key":"73299_CR2","doi-asserted-by":"publisher","first-page":"940","DOI":"10.2106\/00004623-200405000-00009","volume":"86","author":"S Kamineni","year":"2004","unstructured":"Kamineni, S. & Morrey, B. F. Distal humeral fractures treated with noncustom total elbow replacement. J. Bone Joint Surg. Am. 86(5), 940\u2013947. https:\/\/doi.org\/10.2106\/00004623-200405000-00009 (2004).","journal-title":"J. Bone Joint Surg. Am."},{"issue":"6","key":"73299_CR3","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1016\/j.otsr.2013.04.007","volume":"99","author":"D Saragaglia","year":"2013","unstructured":"Saragaglia, D., Rouchy, R. C. & Mercier, N. Fractures of the distal humerus operated on using the Lambda plate: report of 75 cases at 9.5 years follow-up. Orthop. Traumatol. Surg. Res. 99(6), 707\u2013712. https:\/\/doi.org\/10.1016\/j.otsr.2013.04.007 (2013).","journal-title":"Orthop. Traumatol. Surg. Res."},{"issue":"6","key":"73299_CR4","doi-asserted-by":"publisher","first-page":"468","DOI":"10.1097\/00005131-199412000-00003","volume":"8","author":"EH Schemitsch","year":"1994","unstructured":"Schemitsch, E. H., Tencer, A. F. & Henley, M. B. Biomechanical evaluation of methods of internal fixation of the distal humerus. J. Orthop. Trauma. 8(6), 468\u2013475 (1994).","journal-title":"J. Orthop. Trauma."},{"issue":"Suppl 1","key":"73299_CR5","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.otsr.2013.11.002","volume":"100","author":"T B\u00e9gu\u00e9","year":"2014","unstructured":"B\u00e9gu\u00e9, T. Articular fractures of the distal humerus. Orthop. Traumatol. Surg. Res. 100 (Suppl 1), 55\u201363. https:\/\/doi.org\/10.1016\/j.otsr.2013.11.002 (2014).","journal-title":"Orthop. Traumatol. Surg. Res."},{"issue":"11","key":"73299_CR6","doi-asserted-by":"publisher","first-page":"3270","DOI":"10.1007\/s11999-012-2376-6","volume":"470","author":"H Paul","year":"2012","unstructured":"Paul, H. & Kim, M. D. Seth S. Leopold Gustilo-Anderson Classif. Clin. Orthop. Relat. Res. 470(11) 3270\u20133274. https:\/\/doi.org\/10.1007\/s11999-012-2376-6 (2012).","journal-title":"Gustilo-Anderson Classif. Clin. Orthop. Relat. Res."},{"key":"73299_CR7","doi-asserted-by":"publisher","unstructured":"Cusick 1, M. C., Nicolas, S., Bonnaig 1, Frederick, M. & Azar 1, B. M. Mauck 1, Richard A Smith 1, Thomas W Throckmorton. 2014 Accuracy and reliability of the Mayo Elbow performance score. 39(6) 1146\u20131150. https:\/\/doi.org\/10.1016\/j.jhsa.2014.01.041","DOI":"10.1016\/j.jhsa.2014.01.041"},{"key":"73299_CR8","doi-asserted-by":"publisher","unstructured":"Lee, S. K., Kim, K. J., Park, K. H. & Choy, W. S. 2014 a comparison between orthogonal and parallel plating methods for distal humerus fractures: a prospective randomized trial. Eur. J. Orthop. Surg. Traumatol. 24(7) 1123\u20131131. https:\/\/doi.org\/10.1007\/s00590-013-1286-y","DOI":"10.1007\/s00590-013-1286-y"},{"issue":"2","key":"73299_CR9","doi-asserted-by":"publisher","first-page":"226","DOI":"10.2106\/00004623-198567020-00008","volume":"67","author":"JB Jupiter","year":"1985","unstructured":"Jupiter, J. B., Neff, U., Holzach, P. & Allg\u00f6wer, M. Intercondylar fractures of the humerus: an operative approach. J. Bone Joint Surg. Am. 67 (2), 226\u2013239 (1985).","journal-title":"J. Bone Joint Surg. Am."},{"issue":"3","key":"73299_CR10","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1097\/00005131-199004030-00004","volume":"4","author":"DL Helfet","year":"1990","unstructured":"Helfet, D. L. & Hotchkiss, R. N. Internal fixation of the distal humerus: a biomechanical comparison of methods. J. Orthop. Trauma. 4 (3), 260\u2013264. https:\/\/doi.org\/10.1097\/00005131-199004030-00004 (1990).","journal-title":"J. Orthop. Trauma."},{"issue":"9","key":"73299_CR11","doi-asserted-by":"publisher","first-page":"950","DOI":"10.1016\/j.clinbiomech.2006.04.018","volume":"21","author":"A Schwartz","year":"2006","unstructured":"Schwartz, A., Oka, R., Odell, T. & Mahar, A. Biomechanical comparison of two different periarticular plating systems for stabilization of complex distal humerus fractures. Clin. Biomech. 21 (9), 950\u2013955. https:\/\/doi.org\/10.1016\/j.clinbiomech.2006.04.018 (2006).","journal-title":"Clin. Biomech."},{"issue":"6","key":"73299_CR12","doi-asserted-by":"publisher","first-page":"778","DOI":"10.1002\/jor.20528","volume":"26","author":"K Stoffel","year":"2008","unstructured":"Stoffel, K., Cunneen, S., Morgan, R., Nicholls, R. & Stachowiak, G. Comparative stability of perpendicular versus parallel double-locking plating systems in osteoporotic comminuted distal humerus fractures. J. Orthop. Res. 26 (6), 778\u2013784. https:\/\/doi.org\/10.1002\/jor.20528 (2008).","journal-title":"J. Orthop. Res."},{"issue":"1","key":"73299_CR13","doi-asserted-by":"publisher","first-page":"147","DOI":"10.3892\/etm.2013.1102","volume":"6","author":"D Tian","year":"2013","unstructured":"Tian, D., Jing, J., Qian, J. & Li, J. Comparison of two different double-plate fixation methods with olecranon osteotomy for intercondylar fractures of the distal humeri of young adults. Exp. Ther. Med. 6 (1), 147\u2013151. https:\/\/doi.org\/10.3892\/etm.2013.1102 (2013).","journal-title":"Exp. Ther. Med."},{"issue":"1","key":"73299_CR14","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1016\/j.aott.2016.11.001","volume":"51","author":"AC Atalar","year":"2017","unstructured":"Atalar, A. C. et al. Biomechanical comparison of orthogonal versus parallel double plating systems in intraarticular distal humerus fractures. Acta Orthop. Traumatol. Turc. 51 (1), 23\u201328. https:\/\/doi.org\/10.1016\/j.aott.2016.11.001 (2017).","journal-title":"Acta Orthop. Traumatol. Turc."},{"issue":"10","key":"73299_CR15","doi-asserted-by":"publisher","first-page":"972","DOI":"10.1016\/j.clinbiomech.2010.07.005","volume":"25","author":"R Penzkofer","year":"2010","unstructured":"Penzkofer, R., Hungerer, S., Wipf, F., von Oldenburg, G. & Augat, P. Anatomical plate configuration affects mechanical performance in distal humerus fractures. Clin. Biomech. 25 (10), 972\u2013978. https:\/\/doi.org\/10.1016\/j.clinbiomech.2010.07.005 (2010).","journal-title":"Clin. Biomech."},{"key":"73299_CR16","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1016\/j.jse.2004.09.033","volume":"14","author":"SW Driscoll","year":"2005","unstructured":"DriscollSW Optimizing stability in distal humeral fracture fixation. J. Shoulder Elb. Surg. 14, 186\u2013194. https:\/\/doi.org\/10.1016\/j.jse.2004.09.033 (2005).","journal-title":"J. Shoulder Elb. Surg."},{"issue":"1","key":"73299_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.7860\/JCDR\/2014\/12137.5479","volume":"9","author":"S Kumar","year":"2015","unstructured":"Kumar, S., Singh, S., Kumar, D., Kumar, N. & Verma, R. Intercondylar humerus fracture: parallel plating and its results. J. Clin. Diagn. Res. 9 (1), 1\u20134. https:\/\/doi.org\/10.7860\/JCDR\/2014\/12137.5479 (2015).","journal-title":"J. Clin. Diagn. Res."},{"issue":"4","key":"73299_CR18","first-page":"241","volume":"6","author":"SR Jacobson","year":"1997","unstructured":"Jacobson, S. R., Glisson, R. R. & Urbaniak, J. R. Comparison of distal humerus fracture fixation: a biomechanical study. J. South. Orthop. Assoc. 6 (4), 241\u2013249 (1997).","journal-title":"J. South. Orthop. Assoc."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-73299-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-73299-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-73299-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,16]],"date-time":"2024-10-16T21:07:54Z","timestamp":1729112874000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-73299-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,13]]},"references-count":18,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["73299"],"URL":"https:\/\/doi.org\/10.1038\/s41598-024-73299-7","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-4301671\/v1","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10,13]]},"assertion":[{"value":"21 April 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 September 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 October 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"The authors affirm that the human research participants provided informed consent for the publication of the radiographs in Figures 1 and 2","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to publish"}}],"article-number":"23913"}}