{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,17]],"date-time":"2026-10-17T15:03:41Z","timestamp":1792249421192,"version":"4.4.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,9,29]],"date-time":"2024-09-29T00:00:00Z","timestamp":1727568000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,9,29]],"date-time":"2024-09-29T00:00:00Z","timestamp":1727568000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100000024","name":"Canada Institutes of Health Research","doi-asserted-by":"crossref","award":["202104PJT-461005"],"award-info":[{"award-number":["202104PJT-461005"]}],"id":[{"id":"10.13039\/501100000024","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"crossref","award":["RTI-2021-00780"],"award-info":[{"award-number":["RTI-2021-00780"]}],"id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-024-73402-y","type":"journal-article","created":{"date-parts":[[2024,9,29]],"date-time":"2024-09-29T11:11:40Z","timestamp":1727608300000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["In vivo, contactless, cellular resolution imaging of the human cornea with Powell lens based line field OCT"],"prefix":"10.1038","volume":"14","author":[{"given":"Keyu","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nima","family":"Abbasi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Wong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kostadinka","family":"Bizheva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,9,29]]},"reference":[{"key":"73402_CR1","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1113\/jphysiol.1957.sp005758","volume":"136","author":"DM Maurice","year":"1957","unstructured":"Maurice, D. M. The structure and transparency of the cornea. J. Physiol.136, 263 (1957).","journal-title":"J. Physiol."},{"key":"73402_CR2","doi-asserted-by":"publisher","first-page":"423","DOI":"10.4103\/0301-4738.100540","volume":"60","author":"MS Oliva","year":"2012","unstructured":"Oliva, M. S., Schottman, T. & Gulati, M. Turning the tide of corneal blindness. Indian J. Ophthalmol.60, 423\u2013427 (2012).","journal-title":"Indian J. Ophthalmol."},{"issue":"1","key":"73402_CR3","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1016\/j.preteyeres.2009.11.001","volume":"29","author":"RL Niederer","year":"2010","unstructured":"Niederer, R. L. & McGhee, C. N. J. Clinical in vivo confocal microscopy of the human cornea in health and disease. Prog. Retin. Eye Res.29(1), 30\u201358 (2010).","journal-title":"Prog. Retin. Eye Res."},{"key":"73402_CR4","doi-asserted-by":"publisher","first-page":"3037","DOI":"10.1364\/BOE.2.003037","volume":"2","author":"R Yadav","year":"2011","unstructured":"Yadav, R. et al. Micrometer axial resolution oct for corneal imaging. Biomed. Opt. Express2, 3037\u20133046 (2011).","journal-title":"Biomed. Opt. Express"},{"key":"73402_CR5","doi-asserted-by":"publisher","first-page":"5578","DOI":"10.1167\/iovs.13-11920","volume":"54","author":"RM Werkmeister","year":"2013","unstructured":"Werkmeister, R. M. et al. Measurement of tear film thickness using ultrahigh-resolution optical coherence tomography. Investig. Ophthalmol. Vis. Sci.54, 5578\u20135583 (2013).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"73402_CR6","doi-asserted-by":"publisher","first-page":"1113","DOI":"10.1364\/OL.40.001113","volume":"40","author":"P Tankam","year":"2015","unstructured":"Tankam, P. et al. Assessing microstructures of the cornea with gabor-domain optical coherence microscopy: pathway for corneal physiology and diseases. Opt. Lett.40, 1113\u20131116 (2015).","journal-title":"Opt. Lett."},{"key":"73402_CR7","doi-asserted-by":"publisher","first-page":"2782","DOI":"10.1167\/iovs.15-18936","volume":"57","author":"K Bizheva","year":"2016","unstructured":"Bizheva, K. et al. In vivo imaging and morphometry of the human pre-descemet\u2019s layer and endothelium with ultrahigh-resolution optical coherence tomography. Investig. Ophthalmol. Vis. Sci.57, 2782\u20132787 (2016).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"73402_CR8","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1364\/BOE.8.000800","volume":"8","author":"K Bizheva","year":"2017","unstructured":"Bizheva, K. et al. Sub-micrometer axial resolution oct for in-vivo imaging of the cellular structure of healthy and keratoconic human corneas. Biomed. Opt. Express8, 800\u2013812 (2017).","journal-title":"Biomed. Opt. Express"},{"key":"73402_CR9","doi-asserted-by":"publisher","first-page":"10752","DOI":"10.1038\/s41598-017-11380-0","volume":"7","author":"S Chen","year":"2017","unstructured":"Chen, S. et al. Visualizing micro-anatomical structures of the posterior cornea with micro-optical coherence tomography. Sci. Rep.7, 10752 (2017).","journal-title":"Sci. Rep."},{"key":"73402_CR10","doi-asserted-by":"publisher","first-page":"5675","DOI":"10.1364\/BOE.10.005675","volume":"10","author":"X Yao","year":"2019","unstructured":"Yao, X. et al. In vivo corneal endothelium imaging using ultrahigh resolution oct. Biomed. Opt. Express10, 5675\u20135686 (2019).","journal-title":"Biomed. Opt. Express"},{"key":"73402_CR11","doi-asserted-by":"publisher","first-page":"14349","DOI":"10.1038\/s41598-018-32814-3","volume":"8","author":"YT Chen","year":"2018","unstructured":"Chen, Y. T. et al. en face and cross-sectional corneal tomograms using sub-micron spatial resolution optical coherence tomography. Sci. Rep.8, 14349 (2018).","journal-title":"Sci. Rep."},{"key":"73402_CR12","doi-asserted-by":"publisher","first-page":"6569","DOI":"10.1364\/BOE.9.006569","volume":"9","author":"B Tan","year":"2018","unstructured":"Tan, B. et al. 250 khz, 1.5 \u03bcm resolution SD-OCT for in-vivo cellular imaging of the human cornea. Biomed. Opt. Express9, 6569\u20136583 (2018).","journal-title":"Biomed. Opt. Express"},{"key":"73402_CR13","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1364\/AO.41.000805","volume":"41","author":"A Dubois","year":"2002","unstructured":"Dubois, A., Vabre, L., Boccara, A.-C. & Beaurepaire, E. High-resolution full-field optical coherence tomography with a linnik microscope. Appl. Opt.41, 805\u2013812 (2002).","journal-title":"Appl. Opt."},{"key":"73402_CR14","doi-asserted-by":"publisher","first-page":"2874","DOI":"10.1364\/AO.43.002874","volume":"43","author":"A Dubois","year":"2004","unstructured":"Dubois, A. et al. Ultrahigh-resolution full-field optical coherence tomography. Appl. Opt.43, 2874\u20132883 (2004).","journal-title":"Appl. Opt."},{"key":"73402_CR15","doi-asserted-by":"publisher","first-page":"2177","DOI":"10.1364\/BOE.10.002177","volume":"10","author":"R Leitgeb","year":"2019","unstructured":"Leitgeb, R. En face optical coherence tomography: A technology review. Biomed. Opt. Express10, 2177\u20132201 (2019).","journal-title":"Biomed. Opt. Express"},{"key":"73402_CR16","doi-asserted-by":"publisher","first-page":"4126","DOI":"10.1167\/iovs.04-0584","volume":"45","author":"K Grieve","year":"2004","unstructured":"Grieve, K. et al. Ocular tissue imaging using ultrahigh-resolution, full-field optical coherence tomography. Investig. Ophthalmol. Vis. Sci.45, 4126\u20134131 (2004).","journal-title":"Investig. Ophthalmol. Vis. Sci."},{"key":"73402_CR17","doi-asserted-by":"publisher","first-page":"041202","DOI":"10.1117\/1.2764461","volume":"12","author":"M Akiba","year":"2007","unstructured":"Akiba, M. et al. Ultrahigh-resolution imaging of human donor cornea using full-field optical coherence tomography. J. Biomed. Opt.12, 041202\u2013041202 (2007).","journal-title":"J. Biomed. Opt."},{"key":"73402_CR18","doi-asserted-by":"publisher","first-page":"526","DOI":"10.3109\/02713683.2014.935444","volume":"40","author":"W Ghouali","year":"2015","unstructured":"Ghouali, W. et al. Full-field optical coherence tomography of human donor and pathological corneas. Curr. Eye Res.40, 526\u2013534 (2015).","journal-title":"Curr. Eye Res."},{"key":"73402_CR19","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1364\/BOE.9.000557","volume":"9","author":"V Mazlin","year":"2018","unstructured":"Mazlin, V. et al. In vivo high resolution human corneal imaging using full-field optical coherence tomography. Biomed. Opt. Express9, 557\u2013568 (2018).","journal-title":"Biomed. Opt. Express"},{"key":"73402_CR20","doi-asserted-by":"publisher","first-page":"1868","DOI":"10.1038\/s41467-020-15792-x","volume":"11","author":"V Mazlin","year":"2020","unstructured":"Mazlin, V. et al. Real-time non-contact cellular imaging and angiography of human cornea and limbus with common-path full-field\/sd oct. Nat. Commun.11, 1868 (2020).","journal-title":"Nat. Commun."},{"key":"73402_CR21","doi-asserted-by":"publisher","first-page":"2849","DOI":"10.1364\/BOE.393801","volume":"11","author":"E Auksorius","year":"2020","unstructured":"Auksorius, E. et al. In vivo imaging of the human cornea with high-speed and high-resolution fourier-domain full-field OCT. Biomed. Opt. Express11, 2849\u20132865 (2020).","journal-title":"Biomed. Opt. Express"},{"key":"73402_CR22","doi-asserted-by":"publisher","first-page":"519","DOI":"10.1364\/OL.24.000519","volume":"24","author":"AF Zuluaga","year":"1999","unstructured":"Zuluaga, A. F. & Richards-Kortum, R. Spatially resolved spectral interferometry for determination of subsurface structure. Opt. Lett.24, 519\u2013521 (1999).","journal-title":"Opt. Lett."},{"key":"73402_CR23","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1364\/OPTICA.4.000924","volume":"4","author":"L Ginner","year":"2017","unstructured":"Ginner, L. et al. Noniterative digital aberration correction for cellular resolution retinal optical coherence tomography in vivo. Optica4, 924\u2013931 (2017).","journal-title":"Optica"},{"issue":"3","key":"73402_CR24","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1364\/BOE.6.000716","volume":"6","author":"DJ Fechtig","year":"2015","unstructured":"Fechtig, D. J. et al. Line-field parallel swept source MHz OCT for structural and functional retinal imaging. Biomed. Opt. Express6(3), 716\u2013735 (2015).","journal-title":"Biomed. Opt. Express"},{"key":"73402_CR25","doi-asserted-by":"publisher","first-page":"eabc1124","DOI":"10.1126\/sciadv.abc1124","volume":"6","author":"VP Pandiyan","year":"2020","unstructured":"Pandiyan, V. P. et al. The optoretinogram reveals the primary steps of phototransduction in the living human eye. Sci. Adv.6, eabc1124 (2020).","journal-title":"Sci. Adv."},{"key":"73402_CR26","doi-asserted-by":"publisher","first-page":"4007","DOI":"10.1364\/BOE.465916","volume":"13","author":"L Han","year":"2022","unstructured":"Han, L. et al. Line-scanning sd-oct for in-vivo, non-contact, volumetric, cellular resolution imaging of the human cornea and limbus. Biomed. Opt. Express13, 4007\u20134020 (2022).","journal-title":"Biomed. Opt. Express"},{"key":"73402_CR27","doi-asserted-by":"publisher","first-page":"2003","DOI":"10.1364\/BOE.486980","volume":"14","author":"K Chen","year":"2023","unstructured":"Chen, K., Song, W., Han, L. & Bizheva, K. Powell lens-based line-field spectral domain optical coherence tomography system for cellular resolution imaging of biological tissue. Biomed. Opt. Express14, 2003\u20132014 (2023).","journal-title":"Biomed. Opt. Express"},{"key":"73402_CR28","unstructured":"ANSI Z80.36-2016 - Ophthalmics - Light hazard protection for ophthalmic instruments."},{"issue":"9","key":"73402_CR29","doi-asserted-by":"publisher","first-page":"5491","DOI":"10.1364\/BOE.530569","volume":"15","author":"N Abbasi","year":"2024","unstructured":"Abbasi, N., Chen, K., Wong, A. & Bizheva, K. Computational approach to correcting defocus and suppressing speckle noise in line-field optical coherence tomography images. Biomed. Opt. Express15 (9), 5491\u20135504 (2024).","journal-title":"Biomed. Opt. Express"},{"key":"73402_CR30","doi-asserted-by":"publisher","first-page":"1778","DOI":"10.1016\/j.ophtha.2013.01.018","volume":"120","author":"HS Dua","year":"2013","unstructured":"Dua, H. S., Faraj, L. A., Said, D. G., Gray, T. & Lowe, J. Human corneal anatomy redefined: A novel pre-descemet\u2019s layer (Dua\u2019s Layer). Ophthalmology120, 1778\u20131785 (2013).","journal-title":"Ophthalmology"},{"key":"73402_CR31","doi-asserted-by":"publisher","first-page":"1138","DOI":"10.5858\/2002-126-1138b-HOTP","volume":"126","author":"GS King","year":"2002","unstructured":"King, G. S. Handbook of toxicologic pathology. Arch. Pathol. Lab. Med.126, 1138\u20131140 (2002).","journal-title":"Arch. Pathol. Lab. Med."},{"key":"73402_CR32","doi-asserted-by":"publisher","first-page":"588","DOI":"10.1016\/j.jcrs.2010.12.037","volume":"37","author":"DW DelMonte","year":"2011","unstructured":"DelMonte, D. W. & Kim, T. Anatomy and physiology of the cornea. J. Cataract. Refract. Surg.37, 588\u2013598 (2011).","journal-title":"J. Cataract. Refract. Surg."},{"key":"73402_CR33","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1016\/0014-4835(76)90003-8","volume":"22","author":"RA Laing","year":"1976","unstructured":"Laing, R. A., Sandstrom, M. M., Berrospi, A. R. & Leibowitz, H. M. Changes in the corneal endothelium as a function of age. Exp. Eye Res.22, 587\u2013594 (1976).","journal-title":"Exp. Eye Res."},{"key":"73402_CR34","doi-asserted-by":"publisher","first-page":"1059","DOI":"10.1364\/BOE.511187","volume":"15","author":"K Neuhaus","year":"2024","unstructured":"Neuhaus, K. et al. Real-time line-field optical coherence tomography for cellular resolution imaging of biological tissue. Biomed. Opt. Express15, 1059\u20131073 (2024).","journal-title":"Biomed. Opt. Express"},{"issue":"8","key":"73402_CR35","doi-asserted-by":"publisher","first-page":"872","DOI":"10.1364\/OPTICA.396949","volume":"7","author":"V Mazlin","year":"2020","unstructured":"Mazlin, V., Irsch, K., Paques, M., Fink, M. & Boccara, A. C. Curved-field optical coherence tomography: Large-field imaging of human corneal cells and nerves. Optica7(8), 872\u2013880 (2020).","journal-title":"Optica"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-73402-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-73402-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-73402-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,29]],"date-time":"2024-09-29T11:12:01Z","timestamp":1727608321000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-73402-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,29]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["73402"],"URL":"https:\/\/doi.org\/10.1038\/s41598-024-73402-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,9,29]]},"assertion":[{"value":"14 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 September 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 September 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"22553"}}