{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T23:48:59Z","timestamp":1793663339756,"version":"4.5.1"},"reference-count":64,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,10,5]],"date-time":"2024-10-05T00:00:00Z","timestamp":1728086400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2024,10,5]],"date-time":"2024-10-05T00:00:00Z","timestamp":1728086400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100004489","name":"Mitacs","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100004489","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000245","name":"Michael Smith Health Research BC","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000245","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-024-74117-w","type":"journal-article","created":{"date-parts":[[2024,10,5]],"date-time":"2024-10-05T08:01:54Z","timestamp":1728115314000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Detecting cardiac states with wearable photoplethysmograms and implications for out-of-hospital cardiac arrest detection"],"prefix":"10.1038","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0510-2554","authenticated-orcid":false,"given":"Mahsa","family":"Khalili","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saud","family":"Lingawi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jacob","family":"Hutton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher B.","family":"Fordyce","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jim","family":"Christenson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Babak","family":"Shadgan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian","family":"Grunau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Calvin","family":"Kuo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,10,5]]},"reference":[{"key":"74117_CR1","first-page":"1","volume":"60","author":"B McNally","year":"2011","unstructured":"McNally, B. et al. Out-of-hospital cardiac arrest surveillance\u2014Cardiac Arrest Registry to Enhance Survival (CARES), United States, October 1, 2005\u2013December 31, 2010. MMWR Surveill Summ.  60, 1\u201319 (2011).","journal-title":"MMWR Surveill Summ."},{"key":"74117_CR2","doi-asserted-by":"publisher","first-page":"1479","DOI":"10.1016\/j.resuscitation.2010.08.006","volume":"81","author":"J Berdowski","year":"2010","unstructured":"Berdowski, J., Berg, R. A., Tijssen, J. G. P. & Koster, R. W. Global incidences of out-of-hospital cardiac arrest and survival rates: systematic review of 67 prospective studies. Resuscitation. 81, 1479\u20131487 (2010).","journal-title":"Resuscitation"},{"key":"74117_CR3","unstructured":"2017 CARES Annual Report. https:\/\/mycares.net\/sitepages\/uploads\/2018\/2017flipbook\/index.html?page=16"},{"key":"74117_CR4","unstructured":"2022 CARES Annual Report. https:\/\/mycares.net\/sitepages\/uploads\/2023\/2022_flipbook\/index.html?page=26"},{"key":"74117_CR5","unstructured":"Cardiac Arrest Annual Report (2019). \u20132020 http:\/\/www.bcehs.ca\/our-research-site\/Documents\/annual_report_cardiac_arrest_2019-2020.pdf"},{"key":"74117_CR6","doi-asserted-by":"crossref","unstructured":"Heidet, M., Grunau, B., Vaillancourt, C. & Baert, V. Trends in out-of-hospital cardiac arrest across the world: Additional data from the CanROC and R\u00e9AC national registries. Resuscitation  187, (2023).","DOI":"10.1016\/j.resuscitation.2023.109786"},{"key":"74117_CR7","doi-asserted-by":"publisher","first-page":"109906","DOI":"10.1016\/j.resuscitation.2023.109906","volume":"190","author":"J Hutton","year":"2023","unstructured":"Hutton, J. et al. The effect of recognition on survival after out-of-hospital cardiac arrest and implications for biosensor technologies. Resuscitation  190, 109906 (2023).","journal-title":"Resuscitation"},{"key":"74117_CR8","doi-asserted-by":"publisher","first-page":"826","DOI":"10.1016\/j.resuscitation.2010.02.005","volume":"81","author":"D Hostler","year":"2010","unstructured":"Hostler, D. et al. Increased survival after EMS witnessed cardiac arrest. Observations from the Resuscitation Outcomes Consortium (ROC) Epistry - Cardiac Arrest. Resuscitation  81, 826\u2013830 (2010).","journal-title":"Resuscitation"},{"key":"74117_CR9","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1186\/s13054-020-2773-2","volume":"24","author":"S Yan","year":"2020","unstructured":"Yan, S. et al. The global survival rate among adult out-of-hospital cardiac arrest patients who received cardiopulmonary resuscitation: a systematic review and meta-analysis. Crit. Care  24, 61 (2020).","journal-title":"Crit. Care"},{"key":"74117_CR10","doi-asserted-by":"publisher","first-page":"1789","DOI":"10.1016\/j.jacc.2023.09.798","volume":"82","author":"TD Rea","year":"2023","unstructured":"Rea, T. D. Resuscitation from out-of-hospital cardiac arrest. J. Am. Coll. Cardiol.  82, 1789\u20131791 (2023).","journal-title":"J. Am. Coll. Cardiol."},{"key":"74117_CR11","doi-asserted-by":"publisher","first-page":"1226","DOI":"10.1001\/jamacardio.2017.3471","volume":"2","author":"CB Fordyce","year":"2017","unstructured":"Fordyce, C. B. et al. Association of public health initiatives with outcomes for out-of-hospital cardiac arrest at home and in public locations. JAMA Cardiol.  2, 1226\u20131235 (2017).","journal-title":"JAMA Cardiol."},{"key":"74117_CR12","doi-asserted-by":"publisher","first-page":"e153","DOI":"10.1161\/CIR.0000000000001052","volume":"145","author":"CW Tsao","year":"2022","unstructured":"Tsao, C. W. et al. Heart Disease and Stroke Statistics\u20142022 Update: A Report From the American Heart Association. Circulation  145, e153\u2013e639 (2022).","journal-title":"Circulation"},{"key":"74117_CR13","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/j.resuscitation.2021.12.010","volume":"170","author":"J Yap","year":"2022","unstructured":"Yap, J. et al. Rationale for withholding professional resuscitation in emergency medical system-attended out-of-hospital cardiac arrest. Resuscitation  170, 201\u2013206 (2022).","journal-title":"Resuscitation"},{"key":"74117_CR14","first-page":"e895","volume":"145","author":"PA Heidenreich","year":"2022","unstructured":"Heidenreich, P. A. et al. 2022 AHA\/ACC\/HFSA Guideline for the Management of Heart Failure: A Report of the American College of Cardiology\/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation  145, e895\u2013e1032 (2022).","journal-title":"Circulation"},{"key":"74117_CR15","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1159\/000507075","volume":"145","author":"R Sakhi","year":"2020","unstructured":"Sakhi, R. et al. Outcome of insertable cardiac monitors in symptomatic patients with brugada syndrome at low risk of sudden cardiac death. Cardiology  145, 413\u2013420 (2020).","journal-title":"Cardiology"},{"key":"74117_CR16","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1016\/j.tcm.2018.11.002","volume":"29","author":"Y Krokhaleva","year":"2019","unstructured":"Krokhaleva, Y. & Vaseghi, M. Update on prevention and treatment of sudden cardiac arrest. Trends Cardiovasc. Med.  29, 394\u2013400 (2019).","journal-title":"Trends Cardiovasc. Med."},{"key":"74117_CR17","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1001\/jamacardio.2017.0266","volume":"2","author":"RJ Myerburg","year":"2017","unstructured":"Myerburg, R. J. & Goldberger, J. J. Sudden cardiac arrest risk assessment: population science and the individual risk mandate. JAMA Cardiol.  2, 689\u2013694 (2017).","journal-title":"JAMA Cardiol."},{"key":"74117_CR18","doi-asserted-by":"publisher","first-page":"1840","DOI":"10.1161\/CIRCULATIONAHA.114.013047","volume":"130","author":"RJ Myerburg","year":"2014","unstructured":"Myerburg, R. J. Initiatives for improving out-of-hospital cardiac arrest outcomes. Circulation  130, 1840\u20131843 (2014).","journal-title":"Circulation"},{"key":"74117_CR19","doi-asserted-by":"publisher","first-page":"100277","DOI":"10.1016\/j.resplu.2022.100277","volume":"11","author":"J Hutton","year":"2022","unstructured":"Hutton, J. et al. Sensor technologies to detect out-of-hospital cardiac arrest: A systematic review of diagnostic test performance. Resusc. Plus  11, 100277 (2022).","journal-title":"Resusc. Plus"},{"key":"74117_CR20","unstructured":"Wearables sales worldwide by. region 2015\u20132022 | Statista. https:\/\/www.statista.com\/statistics\/490231\/wearable-devices-worldwide-by-region\/"},{"key":"74117_CR21","unstructured":"Wearable sales by vendor 2014\u20132021. Statista https:\/\/www.statista.com\/statistics\/515634\/wearables-shipments-worldwide-by-vendor\/"},{"key":"74117_CR22","first-page":"195","volume":"4","author":"D Castaneda","year":"2018","unstructured":"Castaneda, D., Esparza, A., Ghamari, M., Soltanpur, C. & Nazeran, H. A review on wearable photoplethysmography sensors and their potential future applications in health care. Int. J. Biosens. Bioelectron.  4, 195\u2013202 (2018).","journal-title":"Int. J. Biosens. Bioelectron."},{"key":"74117_CR23","doi-asserted-by":"publisher","first-page":"282","DOI":"10.3390\/electronics3020282","volume":"3","author":"T Tamura","year":"2014","unstructured":"Tamura, T., Maeda, Y., Sekine, M. & Yoshida, M. Wearable photoplethysmographic sensors\u2014past and present. Electronics  3, 282\u2013302 (2014).","journal-title":"Electronics"},{"key":"74117_CR24","doi-asserted-by":"publisher","first-page":"14","DOI":"10.2174\/157340312801215782","volume":"8","author":"M Elgendi","year":"2012","unstructured":"Elgendi, M. On the analysis of fingertip photoplethysmogram signals. Curr. Cardiol. Rev.  8, 14\u201325 (2012).","journal-title":"Curr. Cardiol. Rev."},{"key":"74117_CR25","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1016\/j.jelectrocard.2021.06.009","volume":"67","author":"S Blok","year":"2021","unstructured":"Blok, S., Piek, M. A., Tulevski, I. I., Somsen, G. A. & Winter, M. M. The accuracy of heartbeat detection using photoplethysmography technology in cardiac patients. J. Electrocardiol.  67, 148\u2013157 (2021).","journal-title":"J. Electrocardiol."},{"key":"74117_CR26","doi-asserted-by":"publisher","first-page":"573","DOI":"10.1016\/j.clp.2012.06.012","volume":"39","author":"R Sahni","year":"2012","unstructured":"Sahni, R. Noninvasive monitoring by photoplethysmography. Clin. Perinatol.  39, 573\u2013583 (2012).","journal-title":"Clin. Perinatol."},{"key":"74117_CR27","doi-asserted-by":"publisher","first-page":"526","DOI":"10.1016\/j.ajem.2019.05.044","volume":"38","author":"P Hubner","year":"2020","unstructured":"Hubner, P. et al. On detection of spontaneous pulse by photoplethysmography in cardiopulmonary resuscitation. Am. J. Emerg. Med.  38, 526\u2013533 (2020).","journal-title":"Am. J. Emerg. Med."},{"key":"74117_CR28","doi-asserted-by":"publisher","first-page":"e201","DOI":"10.1016\/S2589-7500(23)00249-2","volume":"6","author":"R Edgar","year":"2024","unstructured":"Edgar, R. et al. Automated cardiac arrest detection using a photoplethysmography wristband: algorithm development and validation in patients with induced circulatory arrest in the DETECT-1 study. Lancet Digit. Health  6, e201\u2013e210 (2024).","journal-title":"Lancet Digit. Health"},{"key":"74117_CR29","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1136\/bmjopen-2019-030833","volume":"9","author":"Y Lee","year":"2019","unstructured":"Lee, Y., Shin, H., Choi, H. J. & Kim, C. Can pulse check by the photoplethysmography sensor on a smart watch replace carotid artery palpation during cardiopulmonary resuscitation in cardiac arrest patients? A prospective observational diagnostic accuracy study. BMJ Open.  9, 1\u20135 (2019).","journal-title":"BMJ Open."},{"key":"74117_CR30","doi-asserted-by":"publisher","first-page":"1136","DOI":"10.1007\/s10439-024-03442-y","volume":"52","author":"S Lingawi","year":"2024","unstructured":"Lingawi, S. et al. Cardiorespiratory sensors and their implications for out-of-hospital cardiac arrest detection: a systematic review. Ann. Biomed. Eng.  52, 1136\u20131158 (2024).","journal-title":"Ann. Biomed. Eng."},{"key":"74117_CR31","doi-asserted-by":"publisher","first-page":"6560","DOI":"10.1109\/JSEN.2019.2914166","volume":"19","author":"D Biswas","year":"2019","unstructured":"Biswas, D., Sim\u00f5es-Capela, N., Van Hoof, C. & Van Helleputte, N. Heart rate estimation from wrist-worn photoplethysmography: a review. IEEE Sens. J.  19, 6560\u20136570 (2019).","journal-title":"IEEE Sens. J."},{"key":"74117_CR32","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1111\/j.1365-2044.1991.tb09411.x","volume":"46","author":"RK Webb","year":"1991","unstructured":"Webb, R. K., Ralston, A. C. & Runciman, W. B. Potential errors in pulse oximetry. Anaesthesia. 46, 207\u2013212 (1991).","journal-title":"Anaesthesia"},{"key":"74117_CR33","doi-asserted-by":"publisher","first-page":"5831","DOI":"10.3390\/s22155831","volume":"22","author":"S Moscato","year":"2022","unstructured":"Moscato, S., Lo Giudice, S., Massaro, G. & Chiari, L. Wrist photoplethysmography signal quality assessment for reliable heart rate estimate and morphological analysis. Sensors  22, 5831 (2022).","journal-title":"Sensors"},{"key":"74117_CR34","doi-asserted-by":"publisher","first-page":"21","DOI":"10.3390\/bioengineering3040021","volume":"3","author":"M Elgendi","year":"2016","unstructured":"Elgendi, M. Optimal signal quality index for photoplethysmogram signals. Bioengineering  3, 21 (2016).","journal-title":"Bioengineering"},{"key":"74117_CR35","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1007\/s10877-017-0030-2","volume":"32","author":"TY Abay","year":"2018","unstructured":"Abay, T. Y. & Kyriacou, P. A. Photoplethysmography for blood volumes and oxygenation changes during intermittent vascular occlusions. J. Clin. Monit. Comput.  32, 447\u2013455 (2018).","journal-title":"J. Clin. Monit. Comput."},{"key":"74117_CR36","doi-asserted-by":"publisher","unstructured":"Karthik, S., Joseph, J. & Sivaprakasam, M. A study on the use of PPG in quantifying circulatory disruptions. In 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society 1739\u20131742 https:\/\/doi.org\/10.1109\/EMBC.2014.6943944 (2014).","DOI":"10.1109\/EMBC.2014.6943944"},{"key":"74117_CR37","first-page":"3405","volume":"2022","author":"I Fedorin","year":"2022","unstructured":"Fedorin, I., Pohribnyi, V., Sverdlov, D. & Krasnoshchok, I. Neural network based algorithm for a spectrogram classification of wrist-type PPG using high-order harmonics processing. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc.  2022, 3405\u20133408 (2022).","journal-title":"Annu. Int. Conf. IEEE Eng. Med. Biol. Soc."},{"key":"74117_CR38","doi-asserted-by":"publisher","first-page":"1250","DOI":"10.1111\/j.1399-6576.2007.01375.x","volume":"51","author":"L Nilsson","year":"2007","unstructured":"Nilsson, L., Goscinski, T., Kalman, S., Lindberg, L.-G. & Johansson, A. Combined photoplethysmographic monitoring of respiration rate and pulse: a comparison between different measurement sites in spontaneously breathing subjects. Acta Anaesthesiol. Scand.  51, 1250\u20131257 (2007).","journal-title":"Acta Anaesthesiol. Scand."},{"key":"74117_CR39","doi-asserted-by":"publisher","first-page":"1874","DOI":"10.3390\/s19081874","volume":"19","author":"SK Longmore","year":"2019","unstructured":"Longmore, S. K. et al. A comparison of reflective photoplethysmography for detection of heart rate, blood oxygen saturation, and respiration rate at various anatomical locations. Sensors  19, 1874 (2019).","journal-title":"Sensors"},{"key":"74117_CR40","doi-asserted-by":"publisher","first-page":"025003","DOI":"10.1088\/1361-6579\/ab029c","volume":"40","author":"A Solo\u0161enko","year":"2019","unstructured":"Solo\u0161enko, A., Petr\u0117nas, A., Paliakait\u0117, B., S\u00f6rnmo, L. & Marozas, V. Detection of atrial fibrillation using a wrist-worn device. Physiol. Meas.  40, 025003 (2019).","journal-title":"Physiol. Meas."},{"key":"74117_CR41","doi-asserted-by":"publisher","first-page":"126","DOI":"10.3390\/bios11040126","volume":"11","author":"J Fine","year":"2021","unstructured":"Fine, J. et al. Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring. Biosensors  11, 126 (2021).","journal-title":"Biosensors"},{"key":"74117_CR42","doi-asserted-by":"crossref","unstructured":"Krittanawong, C. et al. Integration of novel monitoring devices with machine learning technology for scalable cardiovascular management. Nat. Rev. Cardiol.  18, (2020).","DOI":"10.1038\/s41569-020-00445-9"},{"key":"74117_CR43","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1109\/JPROC.2022.3149785","volume":"110","author":"PH Charlton","year":"2022","unstructured":"Charlton, P. H. et al. Wearable photoplethysmography for cardiovascular monitoring. Proc. IEEE  110, 355\u2013381 (2022).","journal-title":"Proc. IEEE"},{"key":"74117_CR44","doi-asserted-by":"publisher","first-page":"741","DOI":"10.1111\/jep.12708","volume":"23","author":"S Chen","year":"2017","unstructured":"Chen, S. et al. Does this patient need telemetry? An analysis of telemetry ordering practices at an academic medical center. J. Eval. Clin. Pract.  23, 741\u2013746 (2017).","journal-title":"J. Eval. Clin. Pract."},{"key":"74117_CR45","doi-asserted-by":"publisher","first-page":"928","DOI":"10.1111\/j.1540-8167.2008.01156.x","volume":"19","author":"M Brignole","year":"2008","unstructured":"Brignole, M. et al. Improved arrhythmia detection in implantable loop recorders. J. Cardiovasc. Electrophys.  19, 928\u2013934 (2008).","journal-title":"J. Cardiovasc. Electrophys."},{"key":"74117_CR46","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.jelectrocard.2020.02.014","volume":"59","author":"A Bisignani","year":"2020","unstructured":"Bisignani, A. et al. Are implantable cardiac monitors reliable tools for cardiac arrhythmias detection? An intra-patient comparison with permanent pacemakers. J. Electrocardiol.  59, 147\u2013150 (2020).","journal-title":"J. Electrocardiol."},{"key":"74117_CR47","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1111\/pace.13912","volume":"43","author":"M De Coster","year":"2020","unstructured":"De Coster, M. et al. Diagnostic accuracy of R-wave detection by insertable cardiac monitors. Pacing Clin. Electrophysiol.  43, 511\u2013517 (2020).","journal-title":"Pacing Clin. Electrophysiol."},{"key":"74117_CR48","doi-asserted-by":"publisher","first-page":"100324","DOI":"10.1016\/j.resplu.2022.100324","volume":"12","author":"P Schober","year":"2022","unstructured":"Schober, P. et al. Smartwatch based automatic detection of out-of-hospital cardiac arrest: Study rationale and protocol of the HEART-SAFE project. Resusc. Plus  12, 100324 (2022).","journal-title":"Resusc. Plus"},{"key":"74117_CR49","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41746-019-0128-7","volume":"2","author":"J Chan","year":"2019","unstructured":"Chan, J., Rea, T., Gollakota, S. & Sunshine, J. E. Contactless cardiac arrest detection using smart devices. npj Digit. Med.  2, 1\u20138 (2019).","journal-title":"npj Digit. Med."},{"key":"74117_CR50","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.ijcard.2018.07.062","volume":"269","author":"N Gaibazzi","year":"2018","unstructured":"Gaibazzi, N., Siniscalchi, C. & Reverberi, C. The Heart Sentinel\u2122\u00a0app for detection and automatic alerting in cardiac arrest during outdoor sports: Field tests and ventricular fibrillation simulation results. Int. J. Cardiol.  269, 133\u2013138 (2018).","journal-title":"Int. J. Cardiol."},{"key":"74117_CR51","doi-asserted-by":"publisher","unstructured":"Maeda, Y. et al. Comparison of reflected green light and infrared photoplethysmography. In 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society 2270\u20132272 https:\/\/doi.org\/10.1109\/IEMBS.2008.4649649  (2008).","DOI":"10.1109\/IEMBS.2008.4649649"},{"key":"74117_CR52","doi-asserted-by":"publisher","first-page":"3","DOI":"10.3390\/jpm7020003","volume":"7","author":"A Shcherbina","year":"2017","unstructured":"Shcherbina, A. et al. Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort. J. Pers. Med.  7, 3 (2017).","journal-title":"J. Pers. Med."},{"key":"74117_CR53","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1001\/archderm.1988.01670060015008","volume":"124","author":"TB Fitzpatrick","year":"1988","unstructured":"Fitzpatrick, T. B. The validity and practicality of sun-reactive skin types I through VI. Arch. Dermatol.  124, 869\u2013871 (1988).","journal-title":"Arch. Dermatol."},{"key":"74117_CR54","doi-asserted-by":"publisher","first-page":"27106","DOI":"10.1109\/JSEN.2021.3123243","volume":"21","author":"P Mehrgardt","year":"2021","unstructured":"Mehrgardt, P., Khushi, M., Poon, S. & Withana, A. Deep learning fused wearable pressure and PPG data for accurate heart rate monitoring. IEEE Sens. J.  21, 27106\u201327115 (2021).","journal-title":"IEEE Sens. J."},{"key":"74117_CR55","doi-asserted-by":"publisher","unstructured":"Phillips, C., Liaqat, D., Gabel, M. & de Lara, E. WristO2: reliable peripheral oxygen saturation readings from wrist-worn pulse oximeters. In 2021 IEEE International Conference on Pervasive Computing and Communications Workshops and other Affiliated Events (PerCom Workshops) 623\u2013629 https:\/\/doi.org\/10.1109\/PerComWorkshops51409.2021.9430986 (2021).","DOI":"10.1109\/PerComWorkshops51409.2021.9430986"},{"key":"74117_CR56","doi-asserted-by":"crossref","unstructured":"Fiorini, L., Cavallo, F., Martinelli, M. & Rovini, E. Characterization of a PPG wearable sensor to be embedded into an innovative ring-shaped device for healthcare monitoring. In Ambient Assisted Living: Italian Forum 2019 Vol.\u00a010, 49\u201363 (Springer International Publishing, 2021).","DOI":"10.1007\/978-3-030-63107-9_5"},{"key":"74117_CR57","doi-asserted-by":"publisher","first-page":"1895","DOI":"10.1016\/j.hrthm.2011.07.030","volume":"8","author":"J Rickard","year":"2011","unstructured":"Rickard, J. et al. Utility of a novel watch-based pulse detection system to detect pulselessness in human subjects. Heart Rhythm  8, 1895\u20131899 (2011).","journal-title":"Heart Rhythm"},{"key":"74117_CR58","unstructured":"Clifford, G. D. ECG statistics, noise, artifacts, and missing data. In Advanced Methods and Tools for ECG Data Analysis 55\u201399 (2006)."},{"key":"74117_CR59","doi-asserted-by":"publisher","first-page":"2498","DOI":"10.1038\/s41598-022-06301-9","volume":"12","author":"L Bodenes","year":"2022","unstructured":"Bodenes, L. et al. Early heart rate variability evaluation enables to predict ICU patients\u2019 outcome. Sci. Rep.  12, 2498 (2022).","journal-title":"Sci. Rep."},{"key":"74117_CR60","doi-asserted-by":"publisher","first-page":"45644","DOI":"10.1038\/srep45644","volume":"7","author":"SC Tang","year":"2017","unstructured":"Tang, S. C. et al. Identification of atrial fibrillation by quantitative analyses of fingertip photoplethysmogram. Sci. Rep.  7, 45644 (2017).","journal-title":"Sci. Rep."},{"key":"74117_CR61","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1109\/TAU.1967.1161901","volume":"15","author":"P Welch","year":"1967","unstructured":"Welch, P. The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms. IEEE Trans. Audio Electroacoust.  15, 70\u201373 (1967).","journal-title":"IEEE Trans. Audio Electroacoust."},{"key":"74117_CR62","doi-asserted-by":"publisher","unstructured":"Bashar, S. K., Han, D., Soni, A., McManus, D. D. & Chon, K. H. Developing a novel noise artifact detection algorithm for smartphone PPG signals: Preliminary results. In 2018 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI) 79\u201382 (2018).\u00a0\u00a0https:\/\/doi.org\/10.1109\/BHI.2018.8333374","DOI":"10.1109\/BHI.2018.8333374"},{"key":"74117_CR63","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1109\/JETCAS.2018.2818185","volume":"8","author":"JW Chong","year":"2018","unstructured":"Chong, J. W. et al. Motion and noise artifact-resilient atrial fibrillation detection using a smartphone. IEEE J. Emerg. Sel. Top. Circuits Syst.  8, 230\u2013239 (2018).","journal-title":"IEEE J. Emerg. Sel. Top. Circuits Syst."},{"key":"74117_CR64","doi-asserted-by":"publisher","first-page":"15054","DOI":"10.1038\/s41598-019-49092-2","volume":"9","author":"SK Bashar","year":"2019","unstructured":"Bashar, S. K. et al. Atrial fibrillation detection from wrist photoplethysmography signals using smartwatche. Sci. Rep.  9, 15054 (2019).","journal-title":"Sci. Rep."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-74117-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-74117-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-74117-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,10,8]],"date-time":"2024-10-08T12:05:19Z","timestamp":1728389119000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-74117-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,5]]},"references-count":64,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["74117"],"URL":"https:\/\/doi.org\/10.1038\/s41598-024-74117-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10,5]]},"assertion":[{"value":"18 April 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 September 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 October 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"23185"}}