{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,15]],"date-time":"2026-07-15T02:16:20Z","timestamp":1784081780674,"version":"3.55.0"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,11,26]],"date-time":"2024-11-26T00:00:00Z","timestamp":1732579200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,11,26]],"date-time":"2024-11-26T00:00:00Z","timestamp":1732579200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100000925","name":"National Health and Medical Research Council","doi-asserted-by":"publisher","award":["APP1162615"],"award-info":[{"award-number":["APP1162615"]}],"id":[{"id":"10.13039\/501100000925","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The carotid-femoral pulse wave velocity (PWV) method is used clinically to determine degrees of stiffness and other indices of disease. It is believed PWV measurement in retinal vessels may allow early detection of diseases. In this paper we present a new non-invasive method for estimating PWVs in retinal vein segments close to the optic disc centre, based on the measurement of blood column pulsation in retinal veins (reflective of vessel wall pulsation), using modified photoplethysmography (PPG). An optic disc (OD) PPG video is acquired spanning three cardiac cycles for a fixed ophthalmodynamometric force. The green colour channel frames are extracted, cropped and aligned. A harmonic regression model is fitted to each pixel intensity time series along the vein centreline from the centre to the periphery of the OD. The phase of the first harmonic is plotted against centreline distance. A least squares line is fitted between the first local maximum phase and first local minimum phase and its slope used to compute PWV. Five left eye inferior hemi-retinal veins from five healthy subjects were analysed. Velocities were calculated for several induced intraocular pressures ranging from a mean baseline of 14 mmHg (SD 5) to 56 mmHg in steps of approximately 5 mmHg. The median PWV over all pressure steps and subjects was 20.77\u00a0mm\/s (IQR 29.27). The experimental results show that pulse wave propagation direction was opposite to flow in this initial venous segment.<\/jats:p>","DOI":"10.1038\/s41598-024-79995-8","type":"journal-article","created":{"date-parts":[[2024,11,26]],"date-time":"2024-11-26T17:51:39Z","timestamp":1732643499000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Calculation of vessel pulse wave velocities in retinal vein segments within the optic disc centre"],"prefix":"10.1038","volume":"14","author":[{"given":"A.","family":"Vukmirovic","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W. H.","family":"Morgan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.","family":"Obreschkow","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Abdul-Rahman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D. Y.","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Mehnert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,11,26]]},"reference":[{"key":"79995_CR1","doi-asserted-by":"publisher","first-page":"7405","DOI":"10.1364\/BOE.441451","volume":"12","author":"R Kolar","year":"2021","unstructured":"Kolar, R., Odstrcilik, J. & Tornow, R. P. Photoplethysmographic analysis of retinal videodata based on the Fourier domain approach. Biomed. Opt. Express. 12, 7405\u20137421. https:\/\/doi.org\/10.1364\/BOE.441451 (2021).","journal-title":"Biomed. Opt. Express"},{"key":"79995_CR2","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.3389\/fphys.2020.01085","volume":"11","author":"JP Mynard","year":"2020","unstructured":"Mynard, J. P. et al. Analysis and interpretation of Pressure\/Flow waves in blood vessels. Front. Physiol. 11, 1085. https:\/\/doi.org\/10.3389\/fphys.2020.01085 (2020).","journal-title":"Front. Physiol."},{"key":"79995_CR3","doi-asserted-by":"publisher","first-page":"e0116475","DOI":"10.1371\/journal.pone.0116475","volume":"10","author":"WH Morgan","year":"2015","unstructured":"Morgan, W. H. et al. Objective detection of retinal vessel pulsation. PLoS One. 10, e0116475. https:\/\/doi.org\/10.1371\/journal.pone.0116475 (2015).","journal-title":"PLoS One"},{"key":"79995_CR4","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.preteyeres.2016.06.003","volume":"55","author":"WH Morgan","year":"2016","unstructured":"Morgan, W. H., Hazelton, M. L. & Yu, D. Y. Retinal venous pulsation: expanding our understanding and use of this enigmatic phenomenon. Prog Retin Eye Res. 55, 82\u2013107. https:\/\/doi.org\/10.1016\/j.preteyeres.2016.06.003 (2016).","journal-title":"Prog Retin Eye Res."},{"key":"79995_CR5","doi-asserted-by":"publisher","first-page":"5190","DOI":"10.1038\/s41598-022-09151-7","volume":"12","author":"WH Morgan","year":"2022","unstructured":"Morgan, W. H. et al. Zero retinal vein pulsation amplitude extrapolated model in non-invasive intracranial pressure estimation. Sci. Rep. 12, 5190. https:\/\/doi.org\/10.1038\/s41598-022-09151-7 (2022).","journal-title":"Sci. Rep."},{"key":"79995_CR6","doi-asserted-by":"publisher","unstructured":"Hughes, A. D., Parker, K. H. & Davies, J. E. Waves in arteries: a review of wave intensity analysis in the systemic and coronary circulations. Artery Res. 2 https:\/\/doi.org\/10.1016\/j.artres.2008.02.002 (2008).","DOI":"10.1016\/j.artres.2008.02.002"},{"key":"79995_CR7","doi-asserted-by":"publisher","first-page":"561","DOI":"10.1016\/j.diii.2013.01.025","volume":"94","author":"E Messas","year":"2013","unstructured":"Messas, E., Pernot, M. & Couade, M. Arterial wall elasticity: state of the art and future prospects. Diagn. Interv Imaging. 94, 561\u2013569. https:\/\/doi.org\/10.1016\/j.diii.2013.01.025 (2013).","journal-title":"Diagn. Interv Imaging"},{"key":"79995_CR8","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1186\/s13104-023-06309-y","volume":"16","author":"A Abdul-Rahman","year":"2023","unstructured":"Abdul-Rahman, A. et al. Empirical retinal venous pulse wave velocity using modified photoplethysmography. BMC Res. Notes. 16, 48. https:\/\/doi.org\/10.1186\/s13104-023-06309-y (2023).","journal-title":"BMC Res. Notes"},{"key":"79995_CR9","doi-asserted-by":"publisher","first-page":"eadf1783","DOI":"10.1126\/sciadv.adf1783","volume":"9","author":"G Laloy-Borgna","year":"2023","unstructured":"Laloy-Borgna, G., Puyo, L., Nishino, H., Atlan, M. & Catheline, S. Observation of natural flexural pulse waves in retinal and carotid arteries for wall elasticity estimation. Sci. Adv. 9, eadf1783. https:\/\/doi.org\/10.1126\/sciadv.adf1783 (2023).","journal-title":"Sci. Adv."},{"key":"79995_CR10","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1167\/iovs.64.13.30","volume":"64","author":"M Hein","year":"2023","unstructured":"Hein, M., Mehnert, A., Freund, K. B., Yu, D. Y. & Balaratnasingam, C. Variability in Capillary perfusion is increased in regions of retinal ischemia due to Branch Retinal vein occlusion. Invest. Ophthalmol. Vis. Sci. 64, 30. https:\/\/doi.org\/10.1167\/iovs.64.13.30 (2023).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"79995_CR11","unstructured":"Sonka, M., Hlavac, V. & Boyle, R. Image Processing, Analysis, and Machine Vision. (Thomson-Engineering, (2007)."},{"key":"79995_CR12","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1023\/B:VISI.0000029664.99615.94","volume":"60","author":"DG Lowe","year":"2004","unstructured":"Lowe, D. G. Distinctive image features from Scale-Invariant keypoints. Int. J. Comput. Vision. 60, 91\u2013110. https:\/\/doi.org\/10.1023\/B:VISI.0000029664.99615.94 (2004).","journal-title":"Int. J. Comput. Vision"},{"key":"79995_CR13","doi-asserted-by":"publisher","first-page":"5998","DOI":"10.1167\/iovs.14-15104","volume":"55","author":"WH Morgan","year":"2014","unstructured":"Morgan, W. H. et al. Photoplethysmographic measurement of various retinal vascular pulsation parameters and measurement of the venous phase delay. Invest. Ophthalmol. Vis. Sci. 55, 5998\u20136006. https:\/\/doi.org\/10.1167\/iovs.14-15104 (2014).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"79995_CR14","doi-asserted-by":"publisher","first-page":"e0270557","DOI":"10.1371\/journal.pone.0270557","volume":"17","author":"A Abdul-Rahman","year":"2022","unstructured":"Abdul-Rahman, A. et al. Linear interactions between intraocular, intracranial pressure, and retinal vascular pulse amplitude in the fourier domain. PLoS One. 17, e0270557. https:\/\/doi.org\/10.1371\/journal.pone.0270557 (2022).","journal-title":"PLoS One"},{"key":"79995_CR15","doi-asserted-by":"publisher","first-page":"e0232523","DOI":"10.1371\/journal.pone.0232523","volume":"15","author":"A Abdul-Rahman","year":"2020","unstructured":"Abdul-Rahman, A., Morgan, W. & Yu, D. Y. Measurement of normal retinal vascular pulse wave attenuation using modified photoplethysmography. PLoS One. 15, e0232523. https:\/\/doi.org\/10.1371\/journal.pone.0232523 (2020).","journal-title":"PLoS One"},{"key":"79995_CR16","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1038\/nmeth.2019","volume":"9","author":"J Schindelin","year":"2012","unstructured":"Schindelin, J. et al. Fiji: an open-source platform for biological-image analysis. Nat. Methods. 9, 676\u2013682. https:\/\/doi.org\/10.1038\/nmeth.2019 (2012).","journal-title":"Nat. Methods"},{"key":"79995_CR17","unstructured":"R Core Team (2024). R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. URL:https:\/\/www.R-project.org\/."},{"key":"79995_CR18","doi-asserted-by":"publisher","unstructured":"Nakagawa, S., Johnson, P. C. D. & Schielzeth, H. The coefficient of determination R(2) and intra-class correlation coefficient from generalized linear mixed-effects models revisited and expanded. J. R Soc. Interface. 14. https:\/\/doi.org\/10.1098\/rsif.2017.0213 (2017).","DOI":"10.1098\/rsif.2017.0213"},{"key":"79995_CR19","doi-asserted-by":"crossref","unstructured":"Pinheiro, J. C. & Bates, D. M. Mixed-Effects Models in S and S-PLUS (Springer, 2000).","DOI":"10.1007\/978-1-4419-0318-1"},{"key":"79995_CR20","doi-asserted-by":"publisher","unstructured":"Hocking, R. R. A. & Biometrics Invited Paper. The Analysis and Selection of Variables in Linear Regression. Biometrics 32, 1\u201349. https:\/\/doi.org\/10.2307\/2529336 (1976).","DOI":"10.2307\/2529336"},{"key":"79995_CR21","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1046\/j.1442-9071.2001.00399.x","volume":"29","author":"WH Westlake","year":"2001","unstructured":"Westlake, W. H., Morgan, W. H. & Yu, D. Y. A pilot study of in vivo venous pressures in the pig retinal circulation. Clin. Experimental Ophthalmol. 29, 167\u2013170. https:\/\/doi.org\/10.1046\/j.1442-9071.2001.00399.x (2001).","journal-title":"Clin. Experimental Ophthalmol."},{"key":"79995_CR22","doi-asserted-by":"publisher","first-page":"2588","DOI":"10.1093\/eurheartj\/ehl254","volume":"27","author":"S Laurent","year":"2006","unstructured":"Laurent, S. et al. Expert consensus document on arterial stiffness: methodological issues and clinical applications. Eur. Heart J. 27, 2588\u20132605. https:\/\/doi.org\/10.1093\/eurheartj\/ehl254 (2006).","journal-title":"Eur. Heart J."},{"key":"79995_CR23","doi-asserted-by":"publisher","first-page":"558","DOI":"10.1152\/jappl.1971.30.4.558","volume":"30","author":"JH Nippa","year":"1971","unstructured":"Nippa, J. H., Alexander, R. H. & Folse, R. Pulse wave velocity in human veins. J. Appl. Physiol. 30, 558\u2013563. https:\/\/doi.org\/10.1152\/jappl.1971.30.4.558 (1971).","journal-title":"J. Appl. Physiol."},{"key":"79995_CR24","doi-asserted-by":"publisher","first-page":"849","DOI":"10.1016\/j.ultrasmedbio.2019.11.003","volume":"46","author":"L Ermini","year":"2020","unstructured":"Ermini, L., Ferraresi, C., De Benedictis, C. & Roatta, S. Objective assessment of venous pulse wave velocity in healthy humans. Ultrasound Med. Biol. 46, 849\u2013854. https:\/\/doi.org\/10.1016\/j.ultrasmedbio.2019.11.003 (2020).","journal-title":"Ultrasound Med. Biol."},{"key":"79995_CR25","doi-asserted-by":"publisher","unstructured":"George, N. R. et al. Ultrasound for venous local pulse wave velocity: Comparison of pulse transit time methods. Annu Int Conf IEEE Eng Med Biol Soc 1\u20134. https:\/\/doi.org\/10.1109\/EMBC40787.2023.10340269 (2023).","DOI":"10.1109\/EMBC40787.2023.10340269"},{"key":"79995_CR26","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1111\/micc.12036","volume":"20","author":"K Kotliar","year":"2013","unstructured":"Kotliar, K. et al. Retinal pulse wave velocity in young male normotensive and mildly hypertensive subjects. Microcirculation. 20, 405\u2013415. https:\/\/doi.org\/10.1111\/micc.12036 (2013).","journal-title":"Microcirculation"},{"key":"79995_CR27","doi-asserted-by":"publisher","first-page":"4771","DOI":"10.1364\/OL.40.004771","volume":"40","author":"H Spahr","year":"2015","unstructured":"Spahr, H. et al. Imaging pulse wave propagation in human retinal vessels using full-field swept-source optical coherence tomography. Opt. Lett. 40, 4771\u20134774. https:\/\/doi.org\/10.1364\/OL.40.004771 (2015).","journal-title":"Opt. Lett."},{"key":"79995_CR28","doi-asserted-by":"publisher","unstructured":"Li, Q. et al. Retinal pulse wave velocity measurement using spectral-domain optical coherence tomography. J. Biophotonics. 11. https:\/\/doi.org\/10.1002\/jbio.201700163 (2018).","DOI":"10.1002\/jbio.201700163"},{"key":"79995_CR29","doi-asserted-by":"publisher","first-page":"4450","DOI":"10.1364\/OL.434454","volume":"46","author":"P Bedggood","year":"2021","unstructured":"Bedggood, P. & Metha, A. Direct measurement of pulse wave propagation in capillaries of the human retina. Opt. Lett. 46, 4450\u20134453. https:\/\/doi.org\/10.1364\/OL.434454 (2021).","journal-title":"Opt. Lett."},{"key":"79995_CR30","doi-asserted-by":"publisher","unstructured":"Bramwell, J. C. & Hill, A. V. The velocity of pulse wave in man. Proc. R. Soc. Lond. Ser. B Contain. Papers Biol. Char. 93, 298\u2013306. https:\/\/doi.org\/10.1098\/rspb.1922.0022 (1922).","DOI":"10.1098\/rspb.1922.0022"},{"key":"79995_CR31","doi-asserted-by":"crossref","unstructured":"Nichols, W. W., O\u2019Rourke, M., Edelman, E. R. & Vlachopoulos, C. McDonald\u2019s Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles 7th edn 853 (CRC, 2022).","DOI":"10.1201\/9781351253765"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-79995-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-79995-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-79995-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,26]],"date-time":"2024-11-26T18:05:05Z","timestamp":1732644305000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-79995-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,26]]},"references-count":31,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["79995"],"URL":"https:\/\/doi.org\/10.1038\/s41598-024-79995-8","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,11,26]]},"assertion":[{"value":"24 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 November 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 November 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"29404"}}