{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T01:49:55Z","timestamp":1793152195069,"version":"4.5.0"},"reference-count":48,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,1,2]],"date-time":"2025-01-02T00:00:00Z","timestamp":1735776000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,1,2]],"date-time":"2025-01-02T00:00:00Z","timestamp":1735776000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001711","name":"Schweizerischer Nationalfonds zur F\u00f6rderung der Wissenschaftlichen Forschung","doi-asserted-by":"publisher","award":["323530_199395"],"award-info":[{"award-number":["323530_199395"]}],"id":[{"id":"10.13039\/501100001711","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100015075","name":"Janggen-P\u00f6hn-Stiftung","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100015075","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100008485","name":"Schweizerische Akademie der Medizinischen Wissenschaften","doi-asserted-by":"publisher","award":["YTCR 43\/23"],"award-info":[{"award-number":["YTCR 43\/23"]}],"id":[{"id":"10.13039\/501100008485","id-type":"DOI","asserted-by":"publisher"}]},{"name":"AlumniMedizin Basel"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>The eye and the heart are two closely interlinked organs, and many diseases affecting the cardiovascular system manifest in the eye. To contribute to the understanding of blood flow propagation towards the retina, we developed a method to acquire electrocardiogram (ECG) coupled time-resolved dynamic optical coherence tomography (OCT) images. This method allows for continuous synchronised monitoring of the cardiac cycle and retinal blood flow dynamics. The dynamic OCT measurements were used to calculate time-resolved blood flow profiles using fringe washout analysis. The relative fringe washout was computed to generate the flow velocity profiles within arterioles at the optic nerve head rim. We found that the blood column between the heart and the retina propagates within one cardiac cycle, denoting the arrival time as the heart-retina time (HRT). In a group of healthy subjects, the HRT was 144\u2009\u00b1\u200919 ms (mean\u2009\u00b1\u2009SD). The HRT could provide a novel potential biomarker for cardiovascular health in direct relation to retinal perfusion.<\/jats:p>","DOI":"10.1038\/s41598-024-84417-w","type":"journal-article","created":{"date-parts":[[2025,1,3]],"date-time":"2025-01-03T03:45:58Z","timestamp":1735875958000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Heart-retina time analysis using electrocardiogram-coupled time-resolved dynamic optical coherence tomography"],"prefix":"10.1038","volume":"15","author":[{"given":"Philippe","family":"Valmaggia","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julia","family":"Wolleb","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florentin","family":"Bieder","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hendrik P. N.","family":"Scholl","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philippe C.","family":"Cattin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter M.","family":"Maloca","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,1,2]]},"reference":[{"key":"84417_CR1","doi-asserted-by":"publisher","first-page":"1270","DOI":"10.1093\/eurheartj\/eht023","volume":"34","author":"J Flammer","year":"2013","unstructured":"Flammer, J. et al. The eye and the heart. Eur. Heart J. 34, 1270\u20131278 (2013).","journal-title":"Eur. Heart J."},{"key":"84417_CR2","doi-asserted-by":"crossref","unstructured":"Chatterjee, S., Chattopadhya, S., Hope-Ross, M. & Lip, P. L. Hypertension and the eye: changing perspectives. J. Hum. Hypertens. 16, 667\u2013675 (2002).","DOI":"10.1038\/sj.jhh.1001472"},{"key":"84417_CR3","doi-asserted-by":"publisher","unstructured":"Farrah, T. E., Dhillon, B., Keane, P. A., Webb, D. J. & Dhaun, N. The eye, the kidney, and cardiovascular disease: old concepts, better tools, and new horizons. Kidney Int. 98, 323\u2013342 https:\/\/doi.org\/10.1016\/j.kint.2020.01.039 (2020).","DOI":"10.1016\/j.kint.2020.01.039"},{"key":"84417_CR4","doi-asserted-by":"publisher","first-page":"1627","DOI":"10.1016\/S0161-6420(84)34093-3","volume":"91","author":"GC Brown","year":"1984","unstructured":"Brown, G. C., Shah, H. G., Magargal, L. E. & Savino, P. J. Central retinal vein obstruction and carotid artery disease. Ophthalmology 91, 1627\u20131633 (1984).","journal-title":"Ophthalmology"},{"key":"84417_CR5","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/S0039-6257(01)00234-X","volume":"46","author":"TY Wong","year":"2001","unstructured":"Wong, T. Y. et al. Retinal microvascular abnormalities and their relationship with hypertension, cardiovascular disease, and mortality. Surv. Ophthalmol. 46, 59\u201380 (2001).","journal-title":"Surv. Ophthalmol."},{"key":"84417_CR6","doi-asserted-by":"publisher","first-page":"1134","DOI":"10.1016\/S0140-6736(01)06253-5","volume":"358","author":"TY Wong","year":"2001","unstructured":"Wong, T. Y. et al. Retinal microvascular abnormalities and incident stroke: the atherosclerosis risk in communities study. Lancet 358, 1134\u20131140 (2001).","journal-title":"Lancet"},{"key":"84417_CR7","doi-asserted-by":"publisher","first-page":"1337","DOI":"10.1080\/02713683.2019.1641826","volume":"44","author":"J Kewcharoen","year":"2019","unstructured":"Kewcharoen, J. et al. Prevalence of atrial fibrillation in patients with retinal vessel occlusion and its association: a systematic review and meta-analysis. Curr. Eye Res. 44, 1337\u20131344 (2019).","journal-title":"Curr. Eye Res."},{"key":"84417_CR8","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.compbiomed.2014.02.012","volume":"48","author":"RJ Martis","year":"2014","unstructured":"Martis, R. J., Acharya, U. R. & Adeli, H. Current methods in electrocardiogram characterization. Comput. Biol. Med. 48, 133\u2013149 (2014).","journal-title":"Comput. Biol. Med."},{"key":"84417_CR9","first-page":"1178","volume":"254","author":"D Huang","year":"1991","unstructured":"Huang, D. et al. Optical coherence tomography. Science 254, 1178\u20131181 (1991).","journal-title":"Sci. (1979)"},{"key":"84417_CR10","doi-asserted-by":"publisher","unstructured":"Fujimoto, J. & Swanson, E. The development, commercialization, and impact of optical coherence tomography. Invest. Ophthalmol. Visual Sci. 57, https:\/\/doi.org\/10.1167\/iovs.16-19963 (2016).","DOI":"10.1167\/iovs.16-19963"},{"key":"84417_CR11","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1167\/iovs.65.6.9","volume":"65","author":"P Valmaggia","year":"2024","unstructured":"Valmaggia, P. et al. Time-resolved dynamic optical coherence tomography for retinal blood flow analysis. Invest. Ophthalmol. Vis. Sci. 65, 9\u20139 (2024).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"84417_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.preteyeres.2017.11.003","volume":"64","author":"RF Spaide","year":"2018","unstructured":"Spaide, R. F., Fujimoto, J. G., Waheed, N. K., Sadda, S. R. & Staurenghi, G. Optical coherence tomography angiography. Prog. Retin. Eye Res. 64, 1\u201355 (2018).","journal-title":"Prog Retin Eye Res."},{"key":"84417_CR13","doi-asserted-by":"crossref","unstructured":"Ploner, S. B. et al. NIH Public Access, Toward quantitative optical coherence tomography angiography: Visualizing blood flow speeds in ocular: Pathology using variable interscan time analysis. Retina 36, S118\u2013S126 (2016).","DOI":"10.1097\/IAE.0000000000001328"},{"key":"84417_CR14","doi-asserted-by":"publisher","first-page":"2658","DOI":"10.1364\/BOE.488103","volume":"14","author":"Y Hwang","year":"2023","unstructured":"Hwang, Y. et al. Retinal blood flow speed quantification at the capillary level using temporal autocorrelation fitting OCTA. Biomed. Opt. Express  14, 2658 (2023).","journal-title":"Biomed. Opt. Express"},{"key":"84417_CR15","doi-asserted-by":"publisher","first-page":"1572","DOI":"10.1016\/j.pdpdt.2022.103138","volume":"40","author":"M Dogan","year":"2022","unstructured":"Dogan, M., Akdogan, M., Sabaner, C. & Gobeka, H. H. Morphological changes in retinochoroidal microvasculature after caffeinated versus decaffeinated coffee consumption \u2606. Photodiagn. Photodyn. Ther. 40, 1572\u20131000 (2022).","journal-title":"Photodiagnosis Photodyn Ther."},{"key":"84417_CR16","doi-asserted-by":"publisher","first-page":"1433","DOI":"10.1097\/IAE.0000000000003474","volume":"42","author":"RF Spaide","year":"2022","unstructured":"Spaide, R. F. et al. Imaging the vitreous with a novel boosted optical coherence tomography technique: vitreous degeneration and cisterns. Retina 42, 1433\u20131441 (2022).","journal-title":"Retina"},{"key":"84417_CR17","doi-asserted-by":"publisher","first-page":"1425","DOI":"10.1097\/IAE.0000000000003500","volume":"42","author":"RF Spaide","year":"2022","unstructured":"Spaide, R. F., Valmaggia, P. & Maloca, P. M. Imaging the vitreous with a novel boosted optical coherence tomography technique: Posterior vitreous detachment. Retina 42, 1425\u20131432 (2022).","journal-title":"Retina"},{"key":"84417_CR18","doi-asserted-by":"publisher","unstructured":"Thilagavathy, R. et al. Real-time ECG Signal feature extraction and classification using support vector machine. 2020 Int. Conf. Contemp. Comput. Appl. IC3A 2020. 44\u201348 https:\/\/doi.org\/10.1109\/IC3A48958.2020.233266 (2020).","DOI":"10.1109\/IC3A48958.2020.233266"},{"key":"84417_CR19","unstructured":"Ashwin, K. et al. HealthyPi v4 Arduino Library. https:\/\/github.com\/Protocentral\/protocentral_healthypi4_arduino (2021)."},{"key":"84417_CR20","doi-asserted-by":"crossref","unstructured":"Bernier, L. G., Dudle, G. & Schlunegger, C. METAS time & frequency metrology report. in Proceedings of the IEEE International Frequency Control Symposium and Exposition vol. 2005, pp. 213\u2013216 Institute of Electrical and Electronics Engineers Inc., (2005).","DOI":"10.1109\/FREQ.2005.1573930"},{"key":"84417_CR21","doi-asserted-by":"publisher","unstructured":"Porr, B. & Howell, L. R-peak detector stress test with a new noisy ECG database reveals significant performance differences amongst popular detectors. bioRxiv 722397 https:\/\/doi.org\/10.1101\/722397 (2019).","DOI":"10.1101\/722397"},{"key":"84417_CR22","first-page":"37","volume":"6","author":"WAH Engelse","year":"1979","unstructured":"Engelse, W. A. H. & Zeelenberg, C. A single scan algorithm for QRS-detection and feature extraction. Comput. Cardiol. 6, 37\u201342 (1979).","journal-title":"Comput. Cardiol."},{"key":"84417_CR23","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1109\/83.650848","volume":"7","author":"P Th\u00e9venaz","year":"1998","unstructured":"Th\u00e9venaz, P., Ruttimann, U. E. & Unser, M. A pyramid approach to subpixel registration based on intensity. IEEE Trans. Image Process. 7, 27\u201341 (1998).","journal-title":"IEEE Trans. Image Process."},{"key":"84417_CR24","doi-asserted-by":"crossref","unstructured":"Lou, W. et al. Comparison of two spectral-domain optical coherence tomography scan modes for measuring retinal vessel diameter.  46, 1025\u20131030 https:\/\/doi.org\/10.1080\/02713683.2020.1862238  (2021).","DOI":"10.1080\/02713683.2020.1862238"},{"key":"84417_CR25","doi-asserted-by":"publisher","first-page":"2977","DOI":"10.1364\/OPEX.12.002977","volume":"12","author":"SH Yun","year":"2004","unstructured":"Yun, S. H., Tearney, G. J., de Boer, J. F. & Bouma, B. E. Motion artifacts in optical coherence tomography with frequency-domain ranging. Opt. Express  12, 2977 (2004).","journal-title":"Opt. Express"},{"key":"84417_CR26","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","volume":"30","author":"A Fedorov","year":"2012","unstructured":"Fedorov, A. et al. 3D slicer as an image computing platform for the quantitative imaging network. Magn. Reson. Imaging  30, 1323\u20131341 (2012).","journal-title":"Magn. Reson. Imaging"},{"key":"84417_CR27","doi-asserted-by":"crossref","unstructured":"Wong, T. Y. & Mitchell, P. Hypertensive retinopathy. 351, 2310\u20132317  https:\/\/doi.org\/10.1056\/NEJMra032865 (2004).","DOI":"10.1056\/NEJMra032865"},{"key":"84417_CR28","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1167\/tvst.11.7.12","volume":"11","author":"Y Zhou","year":"2022","unstructured":"Zhou, Y. et al. AutoMorph: automated retinal vascular morphology quantification via a deep learning pipeline. Transl Vis. Sci. Technol. 11, 12\u201312 (2022).","journal-title":"Transl Vis. Sci. Technol."},{"key":"84417_CR29","doi-asserted-by":"crossref","unstructured":"Wagner, S. K. et al. Insights into systemic disease through retinal imaging-based oculomics. Transl Vis. Sci. Technol. 9, (2020).","DOI":"10.1167\/tvst.9.2.6"},{"key":"84417_CR30","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1055\/a-1024-3277","volume":"237","author":"Y Saruhan","year":"2020","unstructured":"Saruhan, Y., Bollinger, O. & Gugleta, K. Analysis of retinal vessel pulsation with electrographic gating - pulsation amplitude and the influence of hyperoxia. Klin. Monbl Augenheilkd  237, 469\u2013473 (2020).","journal-title":"Klin. Monbl Augenheilkd"},{"key":"84417_CR31","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1055\/a-1085-9250","volume":"237","author":"O Bollinger","year":"2020","unstructured":"Bollinger, O., Saruhan, Y. & Gugleta, K. Analysis of retinal vessel pulsations with electrocardiographic gating. Klin. Monbl. Augenheilkd  237, 464\u2013468 (2020).","journal-title":"Klin. Monbl Augenheilkd"},{"key":"84417_CR32","doi-asserted-by":"publisher","first-page":"084002","DOI":"10.1088\/1361-6579\/aad51b","volume":"39","author":"P Salvi","year":"2018","unstructured":"Salvi, P. et al. Systolic time intervals assessed from analysis of the carotid pressure waveform. Physiol. Meas. 39, 084002 (2018).","journal-title":"Physiol. Meas."},{"key":"84417_CR33","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1055\/s-0028-1109304","volume":"226","author":"R Katamay","year":"2009","unstructured":"Katamay, R., Fleischlin, C., Gugleta, K., Flammer, J. & Org\u00fcl, S. Volumetric blood flow measurement in the ophthalmic artery using colour doppler. Klin. Monbl Augenheilkd  226, 249\u2013253 (2009).","journal-title":"Klin. Monbl Augenheilkd"},{"issue":"9","key":"84417_CR34","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1038\/lsa.2015.107","volume":"4","author":"J Yi","year":"2015","unstructured":"Yi, J. et al. Visible light optical coherence tomography measures retinal oxygen metabolic response to systemic oxygenation. Light: Sci. Appl. 4 (9), 4\u2013e334 (2015). (2015).","journal-title":"Light: Sci. Appl."},{"key":"84417_CR35","doi-asserted-by":"publisher","first-page":"141","DOI":"10.4302\/plp.2011.4.05","volume":"3","author":"ME Danielewska","year":"2011","unstructured":"Danielewska, M. E., Szlag, D., Iskander, D. R. & Wojtkowski, M. Analysis of ocular hemodynamic using combined STdOCT and ultrasonic methods. Photon. Lett. Pol. 3, 141\u2013143 (2011).","journal-title":"Photonics Lett. Pol."},{"key":"84417_CR36","doi-asserted-by":"publisher","unstructured":"Littlewood, R., Mollan, S. P., Pepper, I. M. & Hickman, S. J. The utility of fundus fluorescein angiography in neuro-ophthalmology. Neuro Ophthalmol. 43,  217\u2013234 https:\/\/doi.org\/10.1080\/01658107.2019.1604764 (2019).","DOI":"10.1080\/01658107.2019.1604764"},{"key":"84417_CR37","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1016\/0014-4835(83)90021-0","volume":"37","author":"JH Rockey","year":"1983","unstructured":"Rockey, J. H., Li, W. & Eccleston, J. F. Binding of fluorescein and carboxyfluorescein by human serum proteins: significance of kinetic and equilibrium parameters of association in ocular fluorometric studies. Exp. Eye Res. 37, 455\u2013466 (1983).","journal-title":"Exp. Eye Res."},{"key":"84417_CR38","doi-asserted-by":"publisher","first-page":"435","DOI":"10.1016\/0014-4835(82)90089-6","volume":"34","author":"JT Penniston","year":"1982","unstructured":"Penniston, J. T. Fluorescence polarization measurement of binding of fluorescein to albumin. Exp. Eye Res. 34, 435\u2013443 (1982).","journal-title":"Exp. Eye Res."},{"key":"84417_CR39","doi-asserted-by":"crossref","unstructured":"Pour Ebrahim, M. et al. Blood pressure estimation using on-body continuous wave radar and photoplethysmogram in various posture and exercise conditions. Sci. Rep. 9, (2019).","DOI":"10.1038\/s41598-019-52710-8"},{"key":"84417_CR40","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1007\/5584_2016_49","volume":"956","author":"AS Vischer","year":"2017","unstructured":"Vischer, A. S. & Burkard, T. Principles of blood pressure measurement\u2013current techniques, office vs ambulatory blood pressure measurement. Adv. Exp. Med. Biol. 956, 85\u201396 (2017). (Springer New York LLC.","journal-title":"Adv. Exp. Med. Biol."},{"key":"84417_CR41","doi-asserted-by":"publisher","unstructured":"Muehlsteff, J., Aubert, X. L. & Schuett, M. Cuffless estimation of systolic blood pressure for short effort bicycle tests: The prominent role of the pre-ejection period. in Annual International Conference of the IEEE Engineering in Medicine and Biology-Proceedings 5088\u20135092 https:\/\/doi.org\/10.1109\/IEMBS.2006.260275 (2006).","DOI":"10.1109\/IEMBS.2006.260275"},{"key":"84417_CR42","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-020-73143-8","volume":"10","author":"RC Block","year":"2020","unstructured":"Block, R. C. et al. Conventional pulse transit times as markers of blood pressure changes in humans. Sci. Rep. 10, 1\u20139 (2020).","journal-title":"Sci. Rep."},{"key":"84417_CR43","doi-asserted-by":"publisher","first-page":"964","DOI":"10.1109\/TBME.2015.2480679","volume":"63","author":"XR Ding","year":"2016","unstructured":"Ding, X. R., Zhang, Y. T., Liu, J., Dai, W. X. & Tsang, H. K. Continuous Cuffless blood pressure estimation using pulse transit time and photoplethysmogram intensity ratio. IEEE Trans. Biomed. Eng. 63, 964\u2013972 (2016).","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"84417_CR44","doi-asserted-by":"publisher","unstructured":"Ding, X. & Zhang, Y. T. Pulse transit time technique for cuffless unobtrusive blood pressure measurement: from theory to algorithm. Biomed. Eng.  Lett. 9 37\u201352 https:\/\/doi.org\/10.1007\/s13534-019-00096-x (2019).","DOI":"10.1007\/s13534-019-00096-x"},{"key":"84417_CR45","doi-asserted-by":"crossref","unstructured":"Huttunen, J. M. J., K\u00e4rkk\u00e4inen, L. & Lindholm, H. Pulse transit time estimation of aortic pulse wave velocity and blood pressure using machine learning and simulated training data. PLoS Comput. Biol. 15, (2019).","DOI":"10.1371\/journal.pcbi.1007259"},{"key":"84417_CR46","doi-asserted-by":"publisher","first-page":"e266","DOI":"10.1097\/01.hjh.0000941744.21606.17","volume":"41","author":"H Chao","year":"2023","unstructured":"Chao, H. et al. Comparison of influence of office pulse wave velocity and 24-hour ambulatory recording of aortic pulse wave velocity on target damage in hypertension. J. Hypertens. 41, e266 (2023).","journal-title":"J. Hypertens."},{"key":"84417_CR47","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1177\/1747493020963762","volume":"16","author":"SY Jae","year":"2021","unstructured":"Jae, S. Y., Heffernan, K. S., Kurl, S., Kunutsor, S. K. & Laukkanen, J. A. Association between estimated pulse wave velocity and the risk of stroke in middle-aged men. Int. J. Stroke  16, 551\u2013555 (2021).","journal-title":"Int. J. Stroke"},{"key":"84417_CR48","doi-asserted-by":"publisher","first-page":"235","DOI":"10.30773\/pi.2017.08.17","volume":"15","author":"HG Kim","year":"2018","unstructured":"Kim, H. G., Cheon, E. J., Bai, D. S., Lee, Y. H. & Koo, B. H. Stress and heart rate variability: a meta-analysis and review of the literature. Psychiatr. Invest. 15, 235 (2018).","journal-title":"Psychiatry Investig"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-84417-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-84417-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-84417-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,4]],"date-time":"2025-01-04T04:34:30Z","timestamp":1735965270000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-024-84417-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1,2]]},"references-count":48,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["84417"],"URL":"https:\/\/doi.org\/10.1038\/s41598-024-84417-w","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,1,2]]},"assertion":[{"value":"25 August 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 December 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 January 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"PV received speaker fees from Heidelberg Engineering GmbH and Bayer. HPNS is supported by the Swiss National Science Foundation (Project funding: \u201cDeveloping novel outcomes for clinical trials in Stargardt disease using structure\/function relationship and deep learning\u201d #310030_201165, and National Center of Competence in Research Molecular Systems Engineering: \u201cNCCR MSE: Molecular Systems Engineering (phase II)\u201d #51NF40-182895, the Wellcome Trust (PINNACLE study), and the Foundation Fighting Blindness Clinical Research Institute (ProgStar study). Dr. Scholl is member of the Scientific Advisory Board of: Boehringer Ingelheim Pharma GmbH & Co; Droia NV; Eluminex Biosciences; Janssen Research & Development, LLC (Johnson & Johnson); Okuvision GmbH; ReVision Therapeutics Inc.; and Saliogen Therapeutics Inc. Dr. Scholl is a consultant of: Alnylam Pharmaceuticals Inc.; Gerson Lehrman Group Inc.; Guidepoint Global, LLC; and Tenpoint Therapeutics. Dr. Scholl is member of the Data Monitoring and Safety Board\/Committee of Belite Bio (DRAGON trial, NCT05244304; LBS-008-CT02, NCT05266014), F. Hoffmann-La Roche Ltd (VELODROME trial, NCT04657289; DIAGRID trial, NCT05126966; HUTONG trial), ViGeneron (protocol number VG901-2021-A) and member of the Steering Committee of Novo Nordisk (FOCUS trial; NCT03811561). PMM is a consultant of Roche and holds intellectual properties for machine learning at MIMO AG and VisionAI, Switzerland. The other authors declare no conflict. Funding organisations had no influence on the design, performance or evaluation of the current study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"385"}}