{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,30]],"date-time":"2025-08-30T16:57:23Z","timestamp":1756573043643,"version":"3.40.5"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T00:00:00Z","timestamp":1747180800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T00:00:00Z","timestamp":1747180800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"the Technological project of Innovation and Generation of Medical Service Support Capability","award":["20WQ034"],"award-info":[{"award-number":["20WQ034"]}]},{"name":"the first translational medicine project of Hubei Provincial Health Commission in 2021","award":["WJ2021ZH0010"],"award-info":[{"award-number":["WJ2021ZH0010"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Plate fixation is a classic method for treating day II crescent fracture dislocation of the pelvic (CFDP). However, due to the advantages of minimally invasive techniques and reduced complications associated with internal fixation percutaneous cannulated screws have emerged as a promising alternative for treating Day II CFDP. In this study, we propose using an S<jats:sub>2<\/jats:sub>AI screw combined with an LC-2 screw (S<jats:sub>2<\/jats:sub>AI\u2009+\u2009LC-2) for the treatment of Day II CFDP. The aim of this study was to compare its biomechanical stability with that of two conventional fixation methods using finite element analysis (FEA). A finite element (FE) model of pelvic was developed and validated. Three fixation methods were applied: S<jats:sub>1<\/jats:sub> sacroiliac (SI) screws combined with LC-2 screw (S<jats:sub>1<\/jats:sub>\u2009+\u2009LC-2), S<jats:sub>1<\/jats:sub> and S<jats:sub>2<\/jats:sub> SI screws combined with LC-2 screw (S<jats:sub>1<\/jats:sub>\u2009+\u2009S<jats:sub>2<\/jats:sub>\u2009+\u2009LC-2), and S<jats:sub>2<\/jats:sub>AI\u2009+\u2009LC-2. A 500\u00a0N load was applied, and the displacement of the crescent fracture fragments, the stress distribution of the implants, the displacement of the SI joint, and the maximum stress on the bone surrounding the screws were analyzed across the three FE models. After loading 500\u00a0N stress, the maximum displacement of the crescent fracture fragment and the maximum stress of bone around the implant in the S<jats:sub>2<\/jats:sub>AI\u2009+\u2009LC-2 group were the smallest in three groups. The displacement of SI joint in S<jats:sub>2<\/jats:sub>AI\u2009+\u2009LC-2 group was less than that in S<jats:sub>1<\/jats:sub>\u2009+\u2009LC-2 and S<jats:sub>1<\/jats:sub>\u2009+\u2009S<jats:sub>2<\/jats:sub>\u2009+\u2009LC-2 (P\u2009&lt;\u20090.001). The maximum stress of implants in each group is smaller than the yield stress of titanium. The maximum stress of the bone around the screws at SI joint in all models lower than the yield strength of cortical bone. The maximum stress of the bone around LC-2 screws in all models lower than the yield strength of cancellous bone. The S<jats:sub>2<\/jats:sub>AI\u2009+\u2009LC-2 group can achieve reliable stability of the SI joint, and the stress on the bone around the screw could be reduced. The S<jats:sub>2<\/jats:sub>AI\u2009+\u2009LC-2 group has good biomechanical stability and can be considered as a new implant to treat Day II CFDP. <\/jats:p>","DOI":"10.1038\/s41598-025-00156-6","type":"journal-article","created":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T09:31:17Z","timestamp":1747215077000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Biomechanical performance evaluation of S2AI combine with LC-2 screw for day II pelvic crescent fracture dislocation via finite element analysis"],"prefix":"10.1038","volume":"15","author":[{"given":"Xuan","family":"Pei","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jincheng","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhixun","family":"Fang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shenglong","family":"Qian","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Guodong","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianyin","family":"Lei","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ximing","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,5,14]]},"reference":[{"key":"156_CR1","doi-asserted-by":"publisher","first-page":"651","DOI":"10.1302\/0301-620X.89B5.18129","volume":"89","author":"AC Day","year":"2007","unstructured":"Day, A. C., Kinmont, C., Bircher, M. D. & Kumar, S. Crescent fracture-dislocation of the sacroiliac joint: a functional classification. J. Bone Joint Surg. Br. 89, 651\u2013658. https:\/\/doi.org\/10.1302\/0301-620X.89B5.18129 (2007).","journal-title":"J. Bone Joint Surg. Br."},{"key":"156_CR2","doi-asserted-by":"publisher","first-page":"e5614","DOI":"10.7759\/cureus.5614","volume":"11","author":"A Jatoi","year":"2019","unstructured":"Jatoi, A., Sahito, B., Kumar, D., RajputN H & Ali, M. Fixation of crescent pelvic fracture in a tertiary care hospital: a steep learning curve. Cureus 11, e5614. https:\/\/doi.org\/10.7759\/cureus.5614 (2019).","journal-title":"Cureus"},{"key":"156_CR3","first-page":"260","volume":"11","author":"V Bachhal","year":"2021","unstructured":"Bachhal, V., Jindal, K., Rathod, P. M. & Kumar, D. Bilateral crescent fracture-dislocation of the sacroiliac joint: a case-based discussion and review of literature. Int. J. Burns Trauma. 11, 260\u2013266 (2021).","journal-title":"Int. J. Burns Trauma."},{"key":"156_CR4","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1186\/s13018-020-02197-1","volume":"16","author":"G Xiang","year":"2021","unstructured":"Xiang, G. et al. Comparison of percutaneous cross screw fixation versus open reduction and internal fixation for pelvic day type II crescent fracture-dislocation: case-control study. J. Orthop. Surg. Res. 16, 36. https:\/\/doi.org\/10.1186\/s13018-020-02197-1 (2021).","journal-title":"J. Orthop. Surg. Res."},{"key":"156_CR5","doi-asserted-by":"publisher","unstructured":"Shui, X. et al. Percutaneous screw fixation of crescent fracture-dislocation of the sacroiliac joint. Orthopedics. 38, e976-82. (2015). https:\/\/doi.org\/10.3928\/01477447-20151020-05","DOI":"10.3928\/01477447-20151020-05"},{"key":"156_CR6","doi-asserted-by":"publisher","first-page":"2545","DOI":"10.1111\/os.13453","volume":"14","author":"Y Wu","year":"2022","unstructured":"Wu, Y., Chen, H., Zhou, X. & Tang, P. Lateral compression type 2 pelvic fractures-a clinical study of fracture displacement measurement and closed reduction. Orthop. Surg. 14, 2545\u20132552. https:\/\/doi.org\/10.1111\/os.13453 (2022).","journal-title":"Orthop. Surg."},{"key":"156_CR7","doi-asserted-by":"publisher","first-page":"116","DOI":"10.1097\/00005131-200202000-00008","volume":"16","author":"AJ Starr","year":"2002","unstructured":"Starr, A. J., Walter, J. C., Harris, R. W., Reinert, C. M. & Jones, A. L. Percutaneous screw fixation of fractures of the Iliac wing and fracture-dislocations of the sacro-iliac joint (OTA types 61-B2.2 and 61-B2.3, or Young-Burgess lateral compression type II pelvic fractures). J. Orthop. Trauma. 16, 116\u2013123. https:\/\/doi.org\/10.1097\/00005131-200202000-00008 (2002).","journal-title":"J. Orthop. Trauma."},{"key":"156_CR8","doi-asserted-by":"publisher","unstructured":"Zwingmann, J. et al. Intra- and postoperative complications of navigated and conventional techniques in percutaneous iliosacral screw fixation after pelvic fractures: results from the German pelvic trauma registry. Injury 44:1765\u20131772. https:\/\/doi.org\/10.1016\/j.injury.2013.08.008(2013).","DOI":"10.1016\/j.injury.2013.08.008(2013"},{"key":"156_CR9","doi-asserted-by":"publisher","unstructured":"Boudissa, M. et al. Part 1: outcome of posterior pelvic ring injuries and associated prognostic factors - a five-year retrospective study of one hundred and Sixty five operated cases with closed reduction and percutaneous fixation. Int. Orthop. 44:1209\u20131215. https:\/\/doi.org\/10.1007\/s00264-020-04574-1(2020).","DOI":"10.1007\/s00264-020-04574-1(2020"},{"key":"156_CR10","doi-asserted-by":"publisher","first-page":"1821","DOI":"10.1002\/jor.25525","volume":"41","author":"W Zhang","year":"2023","unstructured":"Zhang, W. et al. Finite element analysis of sacral-alar-iliac screw fixation for sacroiliac joint dislocation. J. Orthop. Res. 41, 1821\u20131830. https:\/\/doi.org\/10.1002\/jor.25525 (2023).","journal-title":"J. Orthop. Res."},{"key":"156_CR11","doi-asserted-by":"publisher","first-page":"287","DOI":"10.3171\/2021.4.SPINE202035","volume":"36","author":"N Ikeda","year":"2021","unstructured":"Ikeda, N. et al. The degenerative changes of the sacroiliac joint after S2 alar-iliac screw placement. J. Neurosurg. Spine. 36, 287\u2013293. https:\/\/doi.org\/10.3171\/2021.4.SPINE202035 (2021).","journal-title":"J. Neurosurg. Spine"},{"key":"156_CR12","doi-asserted-by":"publisher","first-page":"739","DOI":"10.1016\/j.medengphy.2006.08.010","volume":"29","author":"ATM Phillips","year":"2007","unstructured":"Phillips, A. T. M. et al. W. Finite element modelling of the pelvic: inclusion of muscular and ligamentous boundary conditions. Med. Eng. Phys. 29, 739\u2013748. https:\/\/doi.org\/10.1016\/j.medengphy.2006.08.010 (2007).","journal-title":"Med. Eng. Phys."},{"key":"156_CR13","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1186\/s13018-022-03169-3","volume":"17","author":"H Hedelin","year":"2022","unstructured":"Hedelin, H. et al. Postoperative stability following a triple pelvic osteotomy is affected by implant configuration: a finite element analysis. J. Orthop. Surg. Res. 17, 275. https:\/\/doi.org\/10.1186\/s13018-022-03169-3 (2022).","journal-title":"J. Orthop. Surg. Res."},{"key":"156_CR14","doi-asserted-by":"publisher","first-page":"e0273351","DOI":"10.1371\/journal.pone.0273351","volume":"17","author":"Y Song","year":"2022","unstructured":"Song, Y., Shao, C., Yang, X. & Lin, F. Biomechanical study of anterior and posterior pelvic rings using pedicle screw fixation for tile C1 pelvic fractures: finite element analysis. PLoS One. 17, e0273351. https:\/\/doi.org\/10.1371\/journal.pone.0273351 (2022).","journal-title":"PLoS One"},{"key":"156_CR15","doi-asserted-by":"publisher","first-page":"2055","DOI":"10.1016\/j.injury.2014.10.052","volume":"45","author":"L Zhang","year":"2014","unstructured":"Zhang, L., Peng, Y., Du, C. & Tang, P. Biomechanical study of four kinds of percutaneous screw fixation in two types of unilateral sacroiliac joint dislocation: a finite element analysis. Injury 45, 2055\u20132059. https:\/\/doi.org\/10.1016\/j.injury.2014.10.052 (2014).","journal-title":"Injury"},{"key":"156_CR16","doi-asserted-by":"publisher","unstructured":"Eichenseer, P. H., Sybert, D. R. & Cotton, J. R. A finite element analysis of sacroiliac joint ligaments in response to different loading conditions. Spine (Phila Pa 36, E1446-52. (1976). https:\/\/doi.org\/10.1097\/BRS.0b013e31820bc705 (2011).","DOI":"10.1097\/BRS.0b013e31820bc705"},{"key":"156_CR17","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1002\/jor.1100050112","volume":"5","author":"JA Miller","year":"1987","unstructured":"Miller, J. A., Schultz, A. B. & Andersson, G. B. Load-displacement behavior of sacroiliac joints. J. Orthop. Res. 5, 92\u2013101. https:\/\/doi.org\/10.1002\/jor.1100050112 (1987).","journal-title":"J. Orthop. Res."},{"key":"156_CR18","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1186\/s13018-025-05676-5","volume":"20","author":"G Meiqi","year":"2025","unstructured":"Meiqi, G. et al. Finite element analysis of retrograde superior Ramus screw of pubis for the Treament of pelvic anterior ring fracture. J. Orthop. Surg. Res. 20, 263. https:\/\/doi.org\/10.1186\/s13018-025-05676-5 (2025).","journal-title":"J. Orthop. Surg. Res."},{"key":"156_CR19","doi-asserted-by":"publisher","first-page":"760","DOI":"10.1016\/j.msec.2016.07.051","volume":"69","author":"E Zhang","year":"2016","unstructured":"Zhang, E., Li, S., Ren, J., Zhang, L. & Han, Y. Effect of extrusion processing on the microstructure, mechanical properties, Biocorrosion properties and antibacterial properties of Ti-Cu sintered alloys. Mater. Sci. Eng. C Mater. Biol. Appl. 69, 760\u2013768. https:\/\/doi.org\/10.1016\/j.msec.2016.07.051 (2016).","journal-title":"Mater. Sci. Eng. C Mater. Biol. Appl."},{"key":"156_CR20","doi-asserted-by":"publisher","first-page":"2758","DOI":"10.1016\/j.jbiomech.2007.01.023","volume":"40","author":"Z Li","year":"2007","unstructured":"Li, Z. et al. Biomechanical response of the pubic symphysis in lateral pelvic impacts: a finite element stud. J. Biomech. 40, 2758\u20132766. https:\/\/doi.org\/10.1016\/j.jbiomech.2007.01.023 (2007).","journal-title":"J. Biomech."},{"key":"156_CR21","doi-asserted-by":"publisher","unstructured":"Calafi, L. A., Routt, M. & L (CHIP). Posterior iliac crescent fracture-dislocation: what morphological variations are amenable to iliosacral screw fixation? Injury. 44, 194-8. (2013). https:\/\/doi.org\/10.1016\/j.injury.2012.10.028","DOI":"10.1016\/j.injury.2012.10.028"},{"key":"156_CR22","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.jot.2019.08.002","volume":"20","author":"L Cai","year":"2019","unstructured":"Cai, L. et al. A novel percutaneous crossed screws fixation in treatment of day type II crescent fracture-dislocation: a finite element analysis. J. Orthop. Translat. 20, 37\u201346. https:\/\/doi.org\/10.1016\/j.jot.2019.08.002 (2019).","journal-title":"J. Orthop. Translat"},{"key":"156_CR23","doi-asserted-by":"publisher","first-page":"2163","DOI":"10.1007\/s00264-015-3106-y","volume":"40","author":"I Carrera","year":"2016","unstructured":"Carrera, I. et al. Fixation of a split fracture of the lateral tibial plateau with a locking screw plate instead of cannulated screws would allow early weight bearing: a computational exploration. Int. Orthop. 40, 2163\u20132169. https:\/\/doi.org\/10.1007\/s00264-015-3106-y (2016).","journal-title":"Int. Orthop."},{"key":"156_CR24","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1186\/s13018-021-02618-9","volume":"16","author":"Z-H Pan","year":"2021","unstructured":"Pan, Z-H., Chen, F-C., Huang, J-M., Sun, C-Y. & Ding, S-L. Modified pedicle screw-rod versus anterior subcutaneous internal pelvic fixation for unstable anterior pelvic ring fracture: a retrospective study and finite element analysis. J. Orthop. Surg. Res. 16, 467. https:\/\/doi.org\/10.1186\/s13018-021-02618-9 (2021).","journal-title":"J. Orthop. Surg. Res."},{"key":"156_CR25","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1186\/s13018-021-02581-5","volume":"16","author":"Y Peng","year":"2021","unstructured":"Peng, Y. et al. Biomechanical study of transsacral-transiliac screw fixation versus lumbopelvic fixation and bilateral triangular fixation for H- and U-type sacrum fractures with traumatic spondylopelvic dissociation: a finite element analysis study. J. Orthop. Surg. Res. 16, 428. https:\/\/doi.org\/10.1186\/s13018-021-02581-5 (2021).","journal-title":"J. Orthop. Surg. Res."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-00156-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-00156-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-00156-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,14]],"date-time":"2025-05-14T09:31:18Z","timestamp":1747215078000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-00156-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,5,14]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["156"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-00156-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,5,14]]},"assertion":[{"value":"15 June 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 April 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 May 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"This study was carried out in accordance with the Code of Ethics of the World Medical Association (Declaration of Helsinki) and approved by the Ethics Committee of General Hospital of Central Theater Command of PLA (ref. no. 2020\u2013027). Computed tomography (CT) scan of pelvic was obtained after t informed consent of the volunteers, and authorized relevant data can be used for scholarly communication.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics statement"}}],"article-number":"16765"}}