{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T06:28:44Z","timestamp":1793687324800,"version":"4.5.1"},"reference-count":87,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,6,4]],"date-time":"2025-06-04T00:00:00Z","timestamp":1748995200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,6,4]],"date-time":"2025-06-04T00:00:00Z","timestamp":1748995200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Natural ventilation plays a vital role in the design of educational buildings, as it directly influences thermal comfort and, consequently, student performance, achievement, and health. This study investigates the impact of window parameters and various ventilation scenarios on indoor natural ventilation, aiming to enhance indoor air quality and thermal comfort in educational facilities in Aswan, Egypt. An experimental case study was conducted using a HOBO MX CO<jats:sub>2<\/jats:sub> data logger to measure air temperature, carbon dioxide (CO<jats:sub>2<\/jats:sub>) levels, and relative humidity. These parameters, along with the predicted mean vote (PMV), were analyzed through four distinct classroom scenarios simulated using the Design Builder software. The scenarios included: (1) single-side natural ventilation during air conditioning operation; (2) solely passive ventilation; (3) 20-minute cross-ventilation intervals between lectures; and (4) extended 60-minute cross-ventilation during lecture breaks to minimize disruptions. Results indicate that a window-to-wall ratio (WWR) of 20% with a window aspect ratio of 1:2 significantly improves air quality and thermal comfort. The findings suggest that windows should be opened for at least 60\u00a0min in summer and 20\u00a0min in winter, resulting in a temperature reduction of 1 to 2\u00a0\u00b0C and a 36% decrease in CO<jats:sub>2<\/jats:sub> concentrations. Additionally, acceptable PMV values were maintained for 40% of the total classroom hours. This research offers practical recommendations to optimize air quality and thermal comfort in educational buildings, thereby supporting student health and academic success. The study introduces a novel approach by integrating window design and WWR to achieve the balance between improving thermal comfort and enhancing natural ventilation in hot, arid climates.<\/jats:p>","DOI":"10.1038\/s41598-025-01362-y","type":"journal-article","created":{"date-parts":[[2025,6,4]],"date-time":"2025-06-04T09:15:34Z","timestamp":1749028534000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":25,"title":["Exploring the impact of window design and ventilation strategies on air quality and thermal comfort in arid educational buildings"],"prefix":"10.1038","volume":"15","author":[{"given":"Ayman","family":"Ragab","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mai Mostafa","family":"Hassieb","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdelaziz Farouk","family":"Mohamed","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,6,4]]},"reference":[{"key":"1362_CR1","doi-asserted-by":"publisher","first-page":"122542","DOI":"10.1016\/j.jclepro.2020.122542","volume":"272","author":"H Yang Liu","year":"2020","unstructured":"Yang Liu, H. et al. Energy consumption prediction and diagnosis of public buildings based on support vector machine learning: A case study in China. J. Clean. Prod. 272, 122542 (2020).","journal-title":"J. Clean. Prod."},{"key":"1362_CR2","doi-asserted-by":"crossref","unstructured":"Santamouris, M. & Vasilakopoulou, K. Present and future energy consumption of buildings: Challenges and opportunities towards decarbonisation, e-Prime-Advances in Electrical Engineering, Electronics and Energy, vol. 1, p. 100002, (2021).","DOI":"10.1016\/j.prime.2021.100002"},{"issue":"9","key":"1362_CR3","doi-asserted-by":"publisher","first-page":"2265","DOI":"10.1016\/j.rser.2007.05.001","volume":"12","author":"M Abdeen","year":"2008","unstructured":"Abdeen, M. & Omer Energy, environment and sustainable development. Renew. Sustain. Energy Rev. 12(9), 2265\u20132300 (2008).","journal-title":"Renew. Sustain. Energy Rev."},{"key":"1362_CR4","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1016\/j.egypro.2017.11.240","volume":"139","author":"M Hamdani","year":"2017","unstructured":"Hamdani, M., Bekkouche, S. M. A., Benouaz, T., Belarbi, R. & Cherier, M. K. The study natural ventilation by using buildings Windows: case study in a hot dry climate, Gharda\u00efa, Algeria. Energy Procedia. 139, 475\u2013480 (2017).","journal-title":"Energy Procedia"},{"key":"1362_CR5","doi-asserted-by":"publisher","first-page":"203","DOI":"10.1016\/j.enbuild.2013.10.006","volume":"72","author":"P Svoboda","year":"2014","unstructured":"J\u00f6rn von Grabe, Svoboda, P., Armin & B\u00e4umler Window ventilation efficiency in the case of buoyancy ventilation. Energy Build. 72, 203\u2013211 (2014).","journal-title":"Energy Build."},{"issue":"2","key":"1362_CR6","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1016\/j.buildenv.2009.06.012","volume":"45","author":"W Yin","year":"2010","unstructured":"Yin, W., Zhang, G., Yang, W. & Wang, X. Natural ventilation potential model considering solution multiplicity, window opening percentage, air velocity and humidity in China. Build. Environ. 45(2), 338\u2013344 (2010).","journal-title":"Build. Environ."},{"key":"1362_CR7","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1016\/j.buildenv.2019.02.043","volume":"154","author":"Tianqi Liu","year":"2019","unstructured":"Tianqi Liu & Lee, W. L. Using response surface regression method to evaluate the influence of window types on ventilation performance of Hong Kong residential buildings. Build. Environ. 154, 167\u2013181 (2019).","journal-title":"Build. Environ."},{"key":"1362_CR8","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1016\/j.enbuild.2015.04.033","volume":"101","author":"N Ardalan Aflaki","year":"2015","unstructured":"Ardalan Aflaki, N., Mahyuddin, Z. A. C., Mahmoud & Mohamad Rizal Baharum A review on natural ventilation applications through Building fa\u00e7ade components and ventilation openings in tropical climates. Energy Build. 101, 153\u2013162 (2015).","journal-title":"Energy Build."},{"issue":"2","key":"1362_CR9","first-page":"101","volume":"49","author":"SA Zaki","year":"2018","unstructured":"Zaki, S. A., Kasim, N. F. M., Ikegaya, N., Hagishima, A. & Ali, M. S. M. Numerical simulation on wind-driven cross ventilation in square arrays of urban buildings with different opening positions. J. Adv. Res. Fluid Mech. Therm. Sci. 49(2), 101\u2013114 (2018).","journal-title":"J. Adv. Res. Fluid Mech. Therm. Sci."},{"issue":"5","key":"1362_CR10","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1016\/j.enbuild.2005.08.008","volume":"38","author":"Gianpiero Evola and Viktor Popov","year":"2006","unstructured":"Gianpiero Evola and Viktor Popov. Computational analysis of wind driven natural ventilation in buildings. Energy Build. 38(5), 491\u2013501 (2006).","journal-title":"Energy Build."},{"issue":"4","key":"1362_CR11","doi-asserted-by":"publisher","first-page":"961","DOI":"10.1016\/j.buildenv.2010.10.029","volume":"46","author":"CF Gao and Wai Ling Lee","year":"2011","unstructured":"CF Gao and Wai Ling Lee. Evaluating the influence of openings configuration on natural ventilation performance of residential units in Hong Kong. Build. Environ. 46(4), 961\u2013969 (2011).","journal-title":"Build. Environ."},{"key":"1362_CR12","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1016\/j.buildenv.2012.03.024","volume":"56","author":"VD Giuli","year":"2012","unstructured":"Giuli, V. D., Pos, O. D. & Carli, M. D. Indoor environmental quality and pupil perception in Italian primary schools. Build. Environ. 56, 335\u2013345 (2012).","journal-title":"Build. Environ."},{"key":"1362_CR13","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1016\/j.solener.2016.03.031","volume":"132","author":"Francesco","year":"2016","unstructured":"Francesco & Goia Search for the optimal window-to-wall ratio in office buildings in different European climates and the implications on total energy saving potential. Sol. Energy. 132, 467\u2013492 (2016).","journal-title":"Sol. Energy"},{"issue":"10","key":"1362_CR14","doi-asserted-by":"publisher","first-page":"1833","DOI":"10.1016\/j.enbuild.2008.04.002","volume":"40","author":"M Santamouris","year":"2008","unstructured":"Santamouris, M. et al. Experimental investigation of the air flow and indoor carbon dioxide concentration in classrooms with intermittent natural ventilation. Energy Build. 40(10), 1833\u20131843 (2008).","journal-title":"Energy Build."},{"key":"1362_CR15","unstructured":"Hoegh-Guldberg, O., Jacob, D. & Taylor, M. Special Report on Global Warming of 1.5\u25e6 C-Chap. 3: Impacts of 1.5\u25e6 C Global Warming on Natural and Human Systems 243 Ed (DOI, 2018)."},{"key":"1362_CR16","doi-asserted-by":"publisher","first-page":"110669","DOI":"10.1016\/j.rser.2020.110669","volume":"138","author":"P Tariq Ahmed","year":"2021","unstructured":"Tariq Ahmed, P., Kumar & Mottet, L. Natural ventilation in warm climates: the challenges of thermal comfort, heatwave resilience and indoor air quality. Renew. Sustain. Energy Rev. 138, 110669 (2021).","journal-title":"Renew. Sustain. Energy Rev."},{"key":"1362_CR17","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1016\/j.atmosenv.2015.10.032","volume":"122","author":"P Kumar","year":"2015","unstructured":"Kumar, P., Khare, M., Harrison, R. M., Bloss, W. J. & Lewis, A. Hugh Coe, and Lidia Morawska, new directions: air pollution challenges for developing megacities like Delhi. Atmos. Environ. 122, 657\u2013661 (2015).","journal-title":"Atmos. Environ."},{"key":"1362_CR18","doi-asserted-by":"crossref","unstructured":"Prashant Kumar, M. F., Andrade, R., Ynoue, A., Fornaro, J. & Martins. . Lidia Morawska, New directions: From biofuels to wood stoves: The modern and ancient air quality challenges in the megacity of S\u00e3o Paulo, Atmospheric Environment, vol. 140, pp. 364\u2013369, (2016).","DOI":"10.1016\/j.atmosenv.2016.05.059"},{"key":"1362_CR19","doi-asserted-by":"publisher","first-page":"730","DOI":"10.1016\/j.proeng.2017.10.003","volume":"205","author":"G Feng","year":"2017","unstructured":"Feng, G. et al. Study on the influence of window-wall ratio on the energy consumption of nearly zero energy buildings. Procedia Eng. 205, 730\u2013737 (2017).","journal-title":"Procedia Eng."},{"key":"1362_CR20","unstructured":"Derek, G. et al. Associations between classroom CO2 concentrations and student attendance in Washington and Idaho, (2004)."},{"key":"1362_CR21","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/j.scs.2014.04.009","volume":"13","author":"M Tanzia Sharmin","year":"2014","unstructured":"Tanzia Sharmin, M. et al. Monitoring Building energy consumption, thermal performance, and indoor air quality in a cold climate region. Sustainable Cities Soc. 13, 57\u201368 (2014).","journal-title":"Sustainable Cities Soc."},{"issue":"2","key":"1362_CR22","first-page":"302","volume":"48","author":"Ayman Ragab Abdel Radi","year":"2020","unstructured":"Ayman Ragab Abdel Radi. The impact of phase change materials on the Buildings enegy efficiency in the hot desert areas the annexed rooms of the traffic Building in new Aswan City as a case study. JES J. Eng. Sci. 48(2), 302\u2013316 (2020).","journal-title":"JES J. Eng. Sci."},{"key":"1362_CR23","doi-asserted-by":"publisher","first-page":"100917","DOI":"10.1016\/j.jobe.2019.100917","volume":"26","author":"C Heracleous","year":"2019","unstructured":"Heracleous, C. & Michael, A. Experimental assessment of the impact of natural ventilation on indoor air quality and thermal comfort conditions of educational buildings in the Eastern mediterranean region during the heating period. J. Building Eng. 26, 100917 (2019).","journal-title":"J. Building Eng."},{"key":"1362_CR24","doi-asserted-by":"publisher","first-page":"113746","DOI":"10.1016\/j.ijheh.2021.113746","volume":"234","author":"C Claudia","year":"2021","unstructured":"Claudia, C. et al. From spontaneous to strategic natural window ventilation: improving indoor air quality in Swiss schools. Int. J. Hyg. Environ Health. 234, 113746 (2021).","journal-title":"Int. J. Hyg. Environ Health"},{"issue":"6","key":"1362_CR25","doi-asserted-by":"publisher","first-page":"1039","DOI":"10.1111\/ina.12403","volume":"27","author":"J William","year":"2017","unstructured":"William, J. & Fisk The ventilation problem in schools: literature review. Indoor Air. 27(6), 1039\u20131051 (2017).","journal-title":"Indoor Air"},{"key":"1362_CR26","doi-asserted-by":"crossref","unstructured":"Joan, M., Daisey, W. J., Angell & Apte, M. G. Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information, Indoor air, vol. 13, no. LBNL-48287, (2003).","DOI":"10.1034\/j.1600-0668.2003.00153.x"},{"key":"1362_CR27","doi-asserted-by":"crossref","unstructured":"Jan & Sundell On the history of indoor air quality and health, Indoor air, vol. 14, no. s 7, pp. 51\u201358, (2004).","DOI":"10.1111\/j.1600-0668.2004.00273.x"},{"issue":"8","key":"1362_CR28","first-page":"513","volume":"11","author":"S Irena Buka","year":"2006","unstructured":"Irena Buka, S., Koranteng, Alvaro, R. & Osornio-Vargas The effects of air pollution on the health of children. Paediatr. Child Health. 11(8), 513\u2013516 (2006).","journal-title":"Paediatr. Child Health"},{"key":"1362_CR29","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.buildenv.2015.03.006","volume":"93","author":"RJ Ulla Haverinen-Shaughnessy","year":"2015","unstructured":"Ulla Haverinen-Shaughnessy, R. J. et al. An assessment of indoor environmental quality in schools and its association with health and performance. Build. Environ. 93, 35\u201340 (2015).","journal-title":"Build. Environ."},{"key":"1362_CR30","doi-asserted-by":"publisher","first-page":"469","DOI":"10.1016\/j.scs.2018.06.003","volume":"41","author":"I Ferdinando Salata","year":"2018","unstructured":"Ferdinando Salata, I. et al. On the necessities to analyse the thermohygrometric perception in aged people. A review about indoor thermal comfort, health and energetic aspects and a perspective for future studies. Sustainable Cities Soc. 41, 469\u2013480 (2018).","journal-title":"Sustainable Cities Soc."},{"key":"1362_CR31","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1016\/j.buildenv.2014.09.028","volume":"82","author":"M Mohammad Taleghani","year":"2014","unstructured":"Mohammad Taleghani, M., Tenpierik, Andy & van den Dobbelsteen Indoor thermal comfort in urban courtyard block dwellings in the Netherlands. Build. Environ. 82, 566\u2013579 (2014).","journal-title":"Build. Environ."},{"key":"1362_CR32","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.buildenv.2017.07.041","volume":"124","author":"Rog\u00e9rio","year":"2017","unstructured":"Rog\u00e9rio & Duarte Maria Da gl\u00f3ria Gomes, and Ant\u00f3nio Moret Rodrigues, classroom ventilation with manual opening of Windows: findings from a two-year-long experimental study of a Portuguese secondary school. Build. Environ. 124, 118\u2013129 (2017).","journal-title":"Build. Environ."},{"key":"1362_CR33","doi-asserted-by":"crossref","unstructured":"Wei You, M., Qin & Ding, W. Improving Building facade design using integrated simulation of daylighting, thermal performance and natural ventilation, in Building Simulation, vol. 6, 269\u2013282 : Springer. (2013).","DOI":"10.1007\/s12273-013-0135-6"},{"issue":"2","key":"1362_CR34","doi-asserted-by":"publisher","first-page":"391","DOI":"10.3130\/jaabe.11.391","volume":"11","author":"C Jinkyun Cho","year":"2012","unstructured":"Jinkyun Cho, C., Yoo & Kim, Y. Effective opening area and installation location of windows for single sided natural ventilation in high-rise residences. J. Asian Archit. Building Eng. 11(2), 391\u2013398 (2012).","journal-title":"J. Asian Archit. Building Eng."},{"key":"1362_CR35","doi-asserted-by":"crossref","unstructured":"Yu, X., Zhang, Q., Kang, J. & Cui, F. Predicting integrated thermal and acoustic performance in naturally ventilated high-rise buildings using CFD and FEM simulation, in Building Simulation, vol. 11, 507\u2013518 : Springer. (2018).","DOI":"10.1007\/s12273-017-0423-7"},{"issue":"4","key":"1362_CR36","first-page":"233","volume":"19","author":"Rania Elghamry and Hamdy Hassan","year":"2020","unstructured":"Rania Elghamry and Hamdy Hassan. Impact of window parameters on the Building envelope on the thermal comfort, energy consumption and cost and environment. Int. J. Vent. 19(4), 233\u2013259 (2020).","journal-title":"Int. J. Vent."},{"key":"1362_CR37","doi-asserted-by":"crossref","unstructured":"Nari Yoon, M. A., Piette, J. M., Han, W., Wu & Malkawi, A. Optimization of window positions for wind-driven natural ventilation performance, Energies, vol. 13, no. 10, p. 2464, (2020).","DOI":"10.3390\/en13102464"},{"issue":"5","key":"1362_CR38","doi-asserted-by":"publisher","first-page":"462","DOI":"10.1080\/01430750.2017.1318782","volume":"39","author":"S Manigandan","year":"2018","unstructured":"Manigandan, S., Gunasekar, P., Devipriya, J., Anderson, A. & Nithya, S. Energy-saving potential by changing window position and size in an isolated Building. Int. J. Ambient Energy. 39(5), 462\u2013466 (2018).","journal-title":"Int. J. Ambient Energy"},{"issue":"2","key":"1362_CR39","first-page":"93","volume":"17","author":"Sherzad Hawendi","year":"2018","unstructured":"Sherzad Hawendi & Gao, S. Impact of windward inlet-opening positions on fluctuation characteristics of wind-driven natural cross ventilation in an isolated house using LES. Int. J. Vent. 17(2), 93\u2013119 (2018).","journal-title":"Int. J. Vent."},{"key":"1362_CR40","doi-asserted-by":"publisher","first-page":"386","DOI":"10.1016\/j.enbuild.2012.07.028","volume":"54","author":"H Wang","year":"2012","unstructured":"Wang, H. & Chen, Q. A new empirical model for predicting single-sided, wind-driven natural ventilation in buildings. Energy Build. 54, 386\u2013394 (2012).","journal-title":"Energy Build."},{"key":"1362_CR41","doi-asserted-by":"crossref","unstructured":"Bramiana, C. N., Aminuddin, A. M. R., Ismail, M. A., Widiastuti, R. & Pramesti, P. U. The Effect of Window Placement on Natural Ventilation Capability in a Jakarta High-Rise Building Unit, Buildings, vol. 13, no. 5, p. 1141, (2023).","DOI":"10.3390\/buildings13051141"},{"issue":"1","key":"1362_CR42","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1016\/j.ijsbe.2015.02.003","volume":"4","author":"D Prakash","year":"2015","unstructured":"Prakash, D. & Ravikumar, P. Analysis of thermal comfort and indoor air flow characteristics for a residential Building room under generalized window opening position at the adjacent walls. Int. J. Sustainable Built Environ. 4(1), 42\u201357 (2015).","journal-title":"Int. J. Sustainable Built Environ."},{"issue":"1","key":"1362_CR43","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1016\/j.apm.2011.05.052","volume":"36","author":"GM Stavrakakis","year":"2012","unstructured":"Stavrakakis, G. M., Zervas, P. L., Sarimveis, H. & Markatos, N. C. Optimization of window-openings design for thermal comfort in naturally ventilated buildings. Appl. Math. Model. 36(1), 193\u2013211 (2012).","journal-title":"Appl. Math. Model."},{"key":"1362_CR44","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1016\/j.enbuild.2017.02.055","volume":"141","author":"A Ghada Elshafei","year":"2017","unstructured":"Ghada Elshafei, A. et al. Numerical and experimental investigations of the impacts of window parameters on indoor natural ventilation in a residential Building. Energy Build. 141, 321\u2013332 (2017).","journal-title":"Energy Build."},{"key":"1362_CR45","doi-asserted-by":"publisher","first-page":"2689","DOI":"10.1016\/j.egypro.2017.12.212","volume":"142","author":"VK Venkiteswaran","year":"2017","unstructured":"Venkiteswaran, V. K., Liman, J., Saqaff, A. & Alkaff Comparative study of passive methods for reducing cooling load. Energy Procedia. 142, 2689\u20132697 (2017).","journal-title":"Energy Procedia"},{"key":"1362_CR46","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1016\/j.enbuild.2011.12.016","volume":"47","author":"A Pino","year":"2012","unstructured":"Pino, A., Bustamante, W., Escobar, R. & Pino, F. E. Thermal and lighting behavior of office buildings in Santiago of Chile. Energy Build. 47, 441\u2013449 (2012).","journal-title":"Energy Build."},{"key":"1362_CR47","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1016\/j.renene.2012.07.029","volume":"50","author":"JW Lee","year":"2013","unstructured":"Lee, J. W., Jung, H. J., Park, J. Y., Lee, J. B. & Yoon, Y. Optimization of Building window system in Asian regions by analyzing solar heat gain and daylighting elements. Renew. Energy. 50, 522\u2013531 (2013).","journal-title":"Renew. Energy"},{"key":"1362_CR48","doi-asserted-by":"publisher","first-page":"2458","DOI":"10.1016\/j.egypro.2015.11.229","volume":"78","author":"Magyar","year":"2015","unstructured":"Norbert Harmati and Zolt\u00e1n & Magyar Influence of WWR, WG and glazing properties on the annual heating and cooling energy demand in buildings. Energy Procedia. 78, 2458\u20132463 (2015).","journal-title":"Energy Procedia"},{"key":"1362_CR49","doi-asserted-by":"publisher","first-page":"1151","DOI":"10.1016\/j.egypro.2018.08.027","volume":"148","author":"P Silvia Cesari","year":"2018","unstructured":"Silvia Cesari, P., Valdiserri, M., Coccagna & Mazzacane, S. Energy savings in hospital patient rooms: the role of windows size and glazing properties. Energy Procedia. 148, 1151\u20131158 (2018).","journal-title":"Energy Procedia"},{"key":"1362_CR50","doi-asserted-by":"publisher","first-page":"506","DOI":"10.1016\/j.solener.2018.10.057","volume":"176","author":"F Bano","year":"2018","unstructured":"Bano, F. & Sehgal, V. Evaluation of energy-efficient design strategies: comparison of the thermal performance of energy-efficient office buildings in composite climate. India Solar Energy. 176, 506\u2013519 (2018).","journal-title":"India Solar Energy"},{"key":"1362_CR51","doi-asserted-by":"publisher","first-page":"456","DOI":"10.1016\/j.scs.2016.05.014","volume":"26","author":"AR Amaral","year":"2016","unstructured":"Amaral, A. R. Eug\u00e9nio Rodrigues, Ad\u00e9lio Rodrigues Gaspar, and \u00c1lvaro Gomes, A thermal performance parametric study of window type, orientation, size and shadowing effect. Sustainable Cities Soc. 26, 456\u2013465 (2016).","journal-title":"Sustainable Cities Soc."},{"issue":"1","key":"1362_CR52","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1016\/j.jksues.2017.03.001","volume":"31","author":"Mamdooh Alwetaishi","year":"2019","unstructured":"Mamdooh Alwetaishi Impact of glazing to wall ratio in various Climatic regions: A case study. J. King Saud University-Engineering Sci. 31(1), 6\u201318 (2019).","journal-title":"J. King Saud University-Engineering Sci."},{"key":"1362_CR53","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.solener.2019.07.037","volume":"189","author":"M Tajda Potr\u010d Obrecht","year":"2019","unstructured":"Tajda Potr\u010d Obrecht, M., Premrov & Vesna \u017degarac, L. Influence of the orientation on the optimal glazing size for passive houses in different European climates (for non-cardinal directions). Sol. Energy. 189, 15\u201325 (2019).","journal-title":"Sol. Energy"},{"key":"1362_CR54","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1016\/j.jobe.2017.04.003","volume":"11","author":"K Samah","year":"2017","unstructured":"Samah, K., Alghoul, H. G., Rijabo, Mohamed, E. & Mashena Energy consumption in buildings: A correlation for the influence of window to wall ratio and window orientation in Tripoli, Libya. J. Building Eng. 11, 82\u201386 (2017).","journal-title":"J. Building Eng."},{"issue":"4","key":"1362_CR55","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.1016\/j.enbuild.2010.12.032","volume":"43","author":"A Gasparella","year":"2011","unstructured":"Gasparella, A., Pernigotto, G., Cappelletti, F., Romagnoni, P. & Baggio, P. Analysis and modelling of window and glazing systems energy performance for a well insulated residential Building. Energy Build. 43(4), 1030\u20131037 (2011).","journal-title":"Energy Build."},{"key":"1362_CR56","doi-asserted-by":"crossref","unstructured":"Abdullah Alsehail and Abdulbasit Almhafdy. The effect of Window-To-Wall ratio (WWR) and window orientation (WO) on the thermal performance: a preliminary overview, Environment-Behaviour Proceedings Journal, vol. 5, no. 15, pp. 165\u2013173, (2020).","DOI":"10.21834\/ebpj.v5i15.2500"},{"key":"1362_CR57","doi-asserted-by":"crossref","unstructured":"Taib, N. S. M., Zaki, S. A., Rijal, H. B. & Razak, A. A. Fitri Yakub, and Mohamed Sukri Mat Ali, Effect of Office Design Characteristics and Anthropometrics on Thermal Comfort in Malaysian Universities Air-Conditioned Buildings, in E3S Web of Conferences, vol. 396, p. 01004: EDP Sciences. (2023).","DOI":"10.1051\/e3sconf\/202339601004"},{"key":"1362_CR58","doi-asserted-by":"publisher","first-page":"104575","DOI":"10.1016\/j.jobe.2022.104575","volume":"54","author":"NSM Taib","year":"2022","unstructured":"Taib, N. S. M., Zaki, S. A., Rijal, H. B., Razak, A. A. & Hagishima, A. Waqas Khalid, and Mohamed Sukri mat Ali, associating thermal comfort and preference in Malaysian universities\u2019 air-conditioned office rooms under various set-point temperatures. J. Building Eng. 54, 104575 (2022).","journal-title":"J. Building Eng."},{"key":"1362_CR59","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1016\/j.buildenv.2017.06.016","volume":"122","author":"SA Zaki","year":"2017","unstructured":"Zaki, S. A., Damiati, S. A. & Rijal, H. B. Aya Hagishima, and Azli Abd Razak, adaptive thermal comfort in university classrooms in Malaysia and Japan. Build. Environ. 122, 294\u2013306 (2017).","journal-title":"Build. Environ."},{"key":"1362_CR60","doi-asserted-by":"publisher","first-page":"581","DOI":"10.1016\/j.buildenv.2012.10.007","volume":"59","author":"P Wargocki","year":"2013","unstructured":"Wargocki, P., David, P. & Wyon Providing better thermal and air quality conditions in school classrooms would be cost-effective. Build. Environ. 59, 581\u2013589 (2013).","journal-title":"Build. Environ."},{"key":"1362_CR61","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1016\/j.jobe.2017.07.014","volume":"13","author":"MK Nematchoua","year":"2017","unstructured":"Nematchoua, M. K. et al. Thermal comfort and comparison of some parameters coming from hospitals and shopping centers under natural ventilation: the case of Madagascar Island. J. Building Eng. 13, 196\u2013206 (2017).","journal-title":"J. Building Eng."},{"issue":"1","key":"1362_CR62","first-page":"45","volume":"1","author":"A David","year":"2002","unstructured":"David, A., Coley & Beisteiner, A. Carbon dioxide levels and ventilation rates in schools. Int. J. Vent. 1(1), 45\u201352 (2002).","journal-title":"Int. J. Vent."},{"issue":"4","key":"1362_CR63","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1016\/j.enbuild.2007.04.013","volume":"40","author":"M Griffiths","year":"2008","unstructured":"Griffiths, M. & Eftekhari, M. Control of CO2 in a naturally ventilated classroom. Energy Build. 40(4), 556\u2013560 (2008).","journal-title":"Energy Build."},{"key":"1362_CR64","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1016\/j.proeng.2017.10.176","volume":"205","author":"Amr Sayed Hassan Abdallah","year":"2017","unstructured":"Amr Sayed Hassan Abdallah. Thermal monitoring and evaluation of indoor CO2 concentration in classrooms of two primary governmental schools in new Assiut City. Egypt. Procedia Eng. 205, 1093\u20131099 (2017).","journal-title":"Egypt. Procedia Eng."},{"key":"1362_CR65","unstructured":"WORLD METEOROLOGICAL ORGANIZATION. World Weather Information Service. (2022). Available: https:\/\/worldweather.wmo.int\/en\/pilot.html"},{"issue":"1","key":"1362_CR66","first-page":"154","volume":"48","author":"MAS Eid","year":"2020","unstructured":"Eid, M. A. S., Hassan, M. H., Othman, M. & EVALUATION OF HYBRID VENTILATION EFFICIENCY TO IMPROVE THE INDOOR AIR QUALITY FOR PATIENTS\u2019ROOMS IN HOSPITALS OF ASWAN CITY. Ayman Rajab Abdel Radi, and Israa SyedJES J. Eng. Sci., 48, 1, 154\u2013168, (2020).","journal-title":"JES J. Eng. Sci."},{"key":"1362_CR67","doi-asserted-by":"crossref","unstructured":"Mostafa, H. S. & Abd Elrady, A. R. The impact of updates the Nubian architecture on internal ventilation, in Vernacular Architecture: Towards a Sustainable Future: CRC, 529\u2013534. (2014).","DOI":"10.1201\/b17393-91"},{"key":"1362_CR68","unstructured":"ANSI, A. S. H. R. A. E. Standard 62.1\u20132019, Ventilation for Acceptable Indoor Air Quality, American Society of Heating, Refrigerating, and Air-Conditioning Engineers (Atlanta, GA, USA,, 2022)."},{"key":"1362_CR69","doi-asserted-by":"crossref","unstructured":"Mohamed, A. F., Gomaa, M. M., Amir, A. A. & Ragab, A. Energy, Thermal, and Economic Benefits of Aerogel Glazing Systems for Educational Buildings in Hot Arid Climates, Sustainability, vol. 15, no. 8, p. 6332, (2023).","DOI":"10.3390\/su15086332"},{"key":"1362_CR70","doi-asserted-by":"crossref","unstructured":"Abdelhafez, M. H. H., Aldersoni, A. A., Gomaa, M. M., Noaime, E. & Alnaim, M. M. Mohammed Alghaseb, and Ayman Ragab, Investigating the Thermal and Energy Performance of Advanced Glazing Systems in the Context of Hail City, KSA, Buildings, vol. 13, no. 3, p. 752, (2023).","DOI":"10.3390\/buildings13030752"},{"key":"1362_CR71","doi-asserted-by":"crossref","unstructured":"Ayman Ragab, N. et al. Environmental and economic benefits of using pomegranate peel waste for insulation bricks, Materials, vol. 16, no. 15, p. 5372, (2023).","DOI":"10.3390\/ma16155372"},{"key":"1362_CR72","unstructured":"Standard, A. S. H. R. A. E. Thermal environmental conditions for human occupancy. ANSI\/ASHRAE, 55, 5, (2023)."},{"key":"1362_CR73","unstructured":"DIN - Deutsches Institut f\u00fcr Normung e.V. and CEN - European Committee for Standardization, DIN EN 16798-3, Energetische Bewertung von Geb\u00e4uden_- L\u00fcftung von Geb\u00e4uden_- Teil_3: L\u00fcftung von Nichtwohngeb\u00e4uden_- Leistungsanforderungen an L\u00fcftungs- und Klimaanlagen und Raumk\u00fchlsysteme (Module M5-1, M5-4); Deutsche Fassung EN_16798-3:2017. Berlin: Deutsches Institut f\u00fcr Normung e.V. & European Committee for Standardization, (2017)."},{"key":"1362_CR74","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1016\/j.enbuild.2011.12.007","volume":"47","author":"R Jing Liu","year":"2012","unstructured":"Jing Liu, R., Yao & McCloy, R. A method to weight three categories of adaptive thermal comfort. Energy Build. 47, 312\u2013320 (2012).","journal-title":"Energy Build."},{"key":"1362_CR75","unstructured":"Technical Requirements for Ventilation Systems,, (1992)."},{"key":"1362_CR76","unstructured":"Heating, Ventilation and Air Conditioning, (1994)."},{"key":"1362_CR77","unstructured":"DIN EN. Ventilation for non-residential buildings-Performance Requirements for Ventilation and room-conditioning Systems Ed (European Committee for Standardization Brussels, 2007)."},{"key":"1362_CR78","doi-asserted-by":"crossref","unstructured":"Mostafa Ahmed Hilal, Ali, M. & Nadi Mostafa Abdelkarem Evaluation of the thermal performance of spaces for drawing halls in building, of architecture department, faculty of engineering, Assiut University Assiut University bulletin for Environmental Research, p. Vol. 23 No, (2020).","DOI":"10.21608\/auber.2020.145530"},{"key":"1362_CR79","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.envsoft.2011.11.009","volume":"30","author":"WD Bert Blocken","year":"2012","unstructured":"Bert Blocken, W. D., Janssen & van Hooff, T. CFD simulation for pedestrian wind comfort and wind safety in urban areas: general decision framework and case study for the Eindhoven university campus. Environ. Model. Softw. 30, 15\u201334 (2012).","journal-title":"Environ. Model. Softw."},{"key":"1362_CR80","doi-asserted-by":"crossref","unstructured":"Ayyad, Y. N. & Sharples, S. Envi-MET validation and sensitivity analysis using field measurements in a hot arid climate, in IOP Conference Series: Earth and Environmental Science, vol. 329, no. 1, p. 012040: IOP Publishing. (2019).","DOI":"10.1088\/1755-1315\/329\/1\/012040"},{"key":"1362_CR81","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1016\/j.enbuild.2014.08.052","volume":"87","author":"G Jordi Cipriano","year":"2015","unstructured":"Jordi Cipriano, G. et al. Evaluation of a multi-stage guided search approach for the calibration of Building energy simulation models. Energy Build. 87, 370\u2013385 (2015).","journal-title":"Energy Build."},{"key":"1362_CR82","doi-asserted-by":"publisher","first-page":"3698","DOI":"10.1016\/j.egypro.2017.03.855","volume":"105","author":"J Taehoon Hong","year":"2017","unstructured":"Taehoon Hong, J., Kim, J., Jeong, M., Lee & Ji, C. Automatic calibration model of a Building energy simulation using optimization algorithm. Energy Procedia. 105, 3698\u20133704 (2017).","journal-title":"Energy Procedia"},{"issue":"15","key":"1362_CR83","doi-asserted-by":"publisher","first-page":"8475","DOI":"10.1021\/es2043855","volume":"46","author":"TH JiMin Kim","year":"2012","unstructured":"JiMin Kim, T. H., Koo, C. W. & Hong, and Economic and environmental evaluation model for selecting the optimum design of green roof systems in elementary schools. Environ. Sci. Technol. 46(15), 8475\u20138483 (2012).","journal-title":"Environ. Sci. Technol."},{"key":"1362_CR84","doi-asserted-by":"publisher","first-page":"109262","DOI":"10.1016\/j.buildenv.2022.109262","volume":"221","author":"P Zheng","year":"2022","unstructured":"Zheng, P., Wu, H., Liu, Y., Ding, Y. & Yang, L. Thermal comfort in temporary buildings: A review. Build. Environ. 221, 109262 (2022).","journal-title":"Build. Environ."},{"key":"1362_CR85","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1016\/j.egypro.2015.12.229","volume":"85","author":"L Mihaela Simion","year":"2016","unstructured":"Mihaela Simion, L., Socaciu & Unguresan, P. Factors which influence the thermal comfort inside of vehicles. Energy Procedia. 85, 472\u2013480 (2016).","journal-title":"Energy Procedia"},{"key":"1362_CR86","doi-asserted-by":"crossref","unstructured":"Pourshaghaghy, A. & Omidvari, M. Examination of thermal comfort in a hospital using PMV\u2013PPD model, Applied ergonomics, vol. 43, no. 6, pp. 1089\u20131095, (2012).","DOI":"10.1016\/j.apergo.2012.03.010"},{"issue":"6","key":"1362_CR87","doi-asserted-by":"publisher","first-page":"533","DOI":"10.1016\/S0378-7788(02)00003-8","volume":"34","author":"PO Fanger","year":"2002","unstructured":"Fanger, P. O., J\u00f8rn & Toftum Extension of the PMV model to non-air-conditioned buildings in warm climates. Energy Build. 34(6), 533\u2013536 (2002).","journal-title":"Energy Build."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-01362-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-01362-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-01362-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,8]],"date-time":"2025-06-08T21:01:51Z","timestamp":1749416511000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-01362-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6,4]]},"references-count":87,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["1362"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-01362-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,6,4]]},"assertion":[{"value":"16 April 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 May 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 June 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"19596"}}