{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T13:14:26Z","timestamp":1790774066187,"version":"4.1.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,2]],"date-time":"2025-07-02T00:00:00Z","timestamp":1751414400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,7,2]],"date-time":"2025-07-02T00:00:00Z","timestamp":1751414400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100004772","name":"Natural Science Foundation of Ningxia Province","doi-asserted-by":"publisher","award":["2023AAC02064"],"award-info":[{"award-number":["2023AAC02064"]}],"id":[{"id":"10.13039\/501100004772","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-025-07119-x","type":"journal-article","created":{"date-parts":[[2025,7,2]],"date-time":"2025-07-02T02:59:38Z","timestamp":1751425178000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Retrospective analysis of open reduction and locking plate fixation in three and four part proximal humeral fractures with efficacy and complications"],"prefix":"10.1038","volume":"15","author":[{"given":"Haiqiang","family":"Ma","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianbin","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xu","family":"Ma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhipeng","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huanhuan","family":"Sun","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Donghui","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liangguo","family":"Si","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peijie","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zewen","family":"Qiao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,2]]},"reference":[{"key":"7119_CR1","doi-asserted-by":"publisher","first-page":"1037","DOI":"10.1001\/jama.2015.1629","volume":"313","author":"A Rangan","year":"2015","unstructured":"Rangan, A. et al. Surgical vs nonsurgical treatment of adults with displaced fractures of the proximal humerus: the PROFHER randomized clinical trial. JAMA 313, 1037\u20131047 (2015).","journal-title":"JAMA"},{"key":"7119_CR2","doi-asserted-by":"publisher","first-page":"1713","DOI":"10.1007\/s00402-019-03252-1","volume":"139","author":"A Klug","year":"2019","unstructured":"Klug, A., Gramlich, Y., Wincheringer, D., Schmidt-Horloh\u00e9, K. & Hoffmann, R. Trends in surgical management of proximal humeral fractures in adults: a nationwide study of records in Germany from 2007 to 2016. Arch. Orthop. Trauma. Surg. 139, 1713\u20131721 (2019).","journal-title":"Arch. Orthop. Trauma. Surg."},{"key":"7119_CR3","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1186\/s13018-017-0639-3","volume":"12","author":"CJ Laux","year":"2017","unstructured":"Laux, C. J., Grubhofer, F., Werner, C. M. L., Simmen, H. P. & Osterhoff, G. Current concepts in locking plate fixation of proximal humerus fractures. J. Orthop. Surg. 12, 137 (2017).","journal-title":"J. Orthop. Surg."},{"key":"7119_CR4","doi-asserted-by":"publisher","first-page":"e374","DOI":"10.5435\/JAAOS-D-18-00360","volume":"28","author":"BW Sears","year":"2020","unstructured":"Sears, B. W., Hatzidakis, A. M. & Johnston, P. S. Intramedullary fixation for proximal humeral fractures. J. Am. Acad. Orthop. Surg. 28, e374\u2013e383 (2020).","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"7119_CR5","doi-asserted-by":"publisher","first-page":"42","DOI":"10.3928\/01477447-20080101-13","volume":"31","author":"JKM Fakler","year":"2008","unstructured":"Fakler, J. K. M., Hogan, C., Heyde, C. E. & John, T. Current concepts in the treatment of proximal humeral fractures. Orthopedics 31, 42\u201351 (2008).","journal-title":"Orthopedics"},{"key":"7119_CR6","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1177\/1941738114550988","volume":"7","author":"MM Khair","year":"2015","unstructured":"Khair, M. M., Dines, J. S. & Dines, D. M. Shoulder arthroplasty: return to sport. Sports Health. 7, 87\u201389 (2015).","journal-title":"Sports Health"},{"key":"7119_CR7","first-page":"137","volume":"52","author":"F Mauch","year":"2023","unstructured":"Mauch, F. & Huth, J. Revision of anatomic shoulder arthroplasty. Orthopadie Heidelb Ger. 52, 137\u2013143 (2023).","journal-title":"Orthopadie Heidelb Ger."},{"key":"7119_CR8","doi-asserted-by":"publisher","first-page":"S33","DOI":"10.1016\/j.otsr.2015.06.031","volume":"102","author":"P Boileau","year":"2016","unstructured":"Boileau, P. Complications and revision of reverse total shoulder arthroplasty. Orthop. Traumatol. Surg. Res. 102, S33\u2013S43 (2016).","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"7119_CR9","doi-asserted-by":"publisher","first-page":"408","DOI":"10.1016\/j.injury.2010.11.058","volume":"42","author":"RC Sproul","year":"2011","unstructured":"Sproul, R. C., Iyengar, J. J., Devcic, Z. & Feeley, B. T. A systematic review of locking plate fixation of proximal humerus fractures. Injury 42, 408\u2013413 (2011).","journal-title":"Injury"},{"key":"7119_CR10","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.1007\/s00590-021-03099-6","volume":"32","author":"R Ranson","year":"2022","unstructured":"Ranson, R. et al. No change in outcome ten years following locking plate repair of displaced proximal humerus fractures. Eur. J. Orthop. Surg. Traumatol. Orthop. Traumatol. 32, 1195\u20131200 (2022).","journal-title":"Eur. J. Orthop. Surg. Traumatol. Orthop. Traumatol."},{"key":"7119_CR11","doi-asserted-by":"publisher","first-page":"1931","DOI":"10.1016\/j.jse.2017.05.003","volume":"26","author":"EM Padegimas","year":"2017","unstructured":"Padegimas, E. M. et al. Defining optimal Calcar screw positioning in proximal humerus fracture fixation. J. Shoulder Elb. Surg. 26, 1931\u20131937 (2017).","journal-title":"J. Shoulder Elb. Surg."},{"key":"7119_CR12","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1111\/os.12564","volume":"11","author":"L Zhao","year":"2019","unstructured":"Zhao, L. et al. Comparison of the effects of proximal humeral internal locking system (PHILOS) alone and PHILOS combined with fibular allograft in the treatment of Neer three- or four-part proximal humerus fractures in the elderly. Orthop. Surg. 11, 1003\u20131012 (2019).","journal-title":"Orthop. Surg."},{"key":"7119_CR13","doi-asserted-by":"publisher","first-page":"536","DOI":"10.5435\/00124635-201109000-00004","volume":"19","author":"AS Neviaser","year":"2011","unstructured":"Neviaser, A. S. & Neviaser, R. J. Adhesive capsulitis of the shoulder. J. Am. Acad. Orthop. Surg. 19, 536\u2013542 (2011).","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"7119_CR14","doi-asserted-by":"publisher","first-page":"60","DOI":"10.4055\/cios.2020.12.1.60","volume":"12","author":"CH Cho","year":"2020","unstructured":"Cho, C. H. et al. Definition, diagnosis, treatment, and prognosis of frozen shoulder: a consensus survey of shoulder specialists. Clin. Orthop. Surg. 12, 60\u201367 (2020).","journal-title":"Clin. Orthop. Surg."},{"key":"7119_CR15","first-page":"160","volume":"1","author":"CR Constant","year":"1987","unstructured":"Constant, C. R. & Murley, A. H. A clinical method of functional assessment of the shoulder. Clin. Orthop. 1, 160\u2013164 (1987).","journal-title":"Clin. Orthop."},{"key":"7119_CR16","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1002\/(SICI)1097-0274(199606)29:6<602::AID-AJIM4>3.0.CO;2-L","volume":"29","author":"PL Hudak","year":"1996","unstructured":"Hudak, P. L., Amadio, P. C. & Bombardier, C. Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand) [corrected]. The upper extremity collaborative group (UECG). Am. J. Ind. Med. 29, 602\u2013608 (1996).","journal-title":"Am. J. Ind. Med."},{"key":"7119_CR17","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s12891-019-2399-1","volume":"20","author":"JE Plath","year":"2019","unstructured":"Plath, J. E. et al. Locking nail versus locking plate for proximal humeral fracture fixation in an elderly population: a prospective randomised controlled trial. BMC Musculoskelet. Disord. 20, 20 (2019).","journal-title":"BMC Musculoskelet. Disord"},{"key":"7119_CR18","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1016\/j.jse.2009.09.005","volume":"19","author":"P Clavert","year":"2010","unstructured":"Clavert, P., Adam, P., Bevort, A., Bonnomet, F. & Kempf, J. F. Pitfalls and complications with locking plate for proximal humerus fracture. J. Shoulder Elb. Surg. 19, 489\u2013494 (2010).","journal-title":"J. Shoulder Elb. Surg."},{"key":"7119_CR19","doi-asserted-by":"publisher","first-page":"3108","DOI":"10.1111\/os.13887","volume":"15","author":"R She","year":"2023","unstructured":"She, R., Zhang, B., Jiang, K., Yang, S. & Zhang, Y. Cement-augmented screw fixation with PHILOS plating for osteoporotic proximal humeral fractures: an observation of mid- and long-term curative efficacy. Orthop. Surg. 15, 3108\u20133117 (2023).","journal-title":"Orthop. Surg."},{"key":"7119_CR20","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1016\/j.jse.2016.02.003","volume":"25","author":"MEC Gracitelli","year":"2016","unstructured":"Gracitelli, M. E. C. et al. Locking intramedullary nails compared with locking plates for two- and three-part proximal humeral surgical neck fractures: a randomized controlled trial. J. Shoulder Elb. Surg. 25, 695\u2013703 (2016).","journal-title":"J. Shoulder Elb. Surg."},{"key":"7119_CR21","doi-asserted-by":"publisher","first-page":"2771","DOI":"10.2106\/00004623-200911000-00040","volume":"91","author":"CM Court-Brown","year":"2009","unstructured":"Court-Brown, C. M. & McQueen, M. Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. J. Bone Joint Surg. Am. 91, 2771 (2009).","journal-title":"J. Bone Joint Surg. Am."},{"key":"7119_CR22","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1007\/s00264-017-3683-z","volume":"42","author":"Q Sun","year":"2018","unstructured":"Sun, Q. et al. Locking plates versus intramedullary nails in the management of displaced proximal humeral fractures: a systematic review and meta-analysis. Int. Orthop. 42, 641\u2013650 (2018).","journal-title":"Int. Orthop."},{"key":"7119_CR23","doi-asserted-by":"publisher","first-page":"1785","DOI":"10.1007\/s00264-020-04544-7","volume":"44","author":"Q Sun","year":"2020","unstructured":"Sun, Q., Wu, X., Wang, L. & Cai, M. The plate fixation strategy of complex proximal humeral fractures. Int. Orthop. 44, 1785\u20131795 (2020).","journal-title":"Int. Orthop."},{"key":"7119_CR24","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1097\/BOT.0b013e318206eb46","volume":"25","author":"C Voigt","year":"2011","unstructured":"Voigt, C., Geisler, A., Hepp, P., Schulz, A. P. & Lill, H. Are polyaxially locked screws advantageous in the plate osteosynthesis of proximal humeral fractures in the elderly? A prospective randomized clinical observational study. J. Orthop. Trauma. 25, 596\u2013602 (2011).","journal-title":"J. Orthop. Trauma."},{"key":"7119_CR25","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1186\/1471-2474-15-206","volume":"15","author":"T Lin","year":"2014","unstructured":"Lin, T., Xiao, B., Ma, X., Fu, D. & Yang, S. Minimally invasive plate osteosynthesis with a locking compression plate is superior to open reduction and internal fixation in the management of the proximal humerus fractures. BMC Musculoskelet. Disord. 15, 206 (2014).","journal-title":"BMC Musculoskelet. Disord"},{"key":"7119_CR26","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1007\/s12306-013-0267-y","volume":"98","author":"MA Verdano","year":"2014","unstructured":"Verdano, M. A. et al. Can the osteosynthesis with locking plates be a better treatment for unstable fractures of the proximal humerus? Musculoskelet. Surg. 98, 27\u201333 (2014).","journal-title":"Musculoskelet. Surg."},{"key":"7119_CR27","doi-asserted-by":"publisher","first-page":"837","DOI":"10.1016\/j.jse.2009.06.004","volume":"18","author":"C Thanasas","year":"2009","unstructured":"Thanasas, C., Kontakis, G., Angoules, A., Limb, D. & Giannoudis, P. Treatment of proximal humerus fractures with locking plates: a systematic review. J. Shoulder Elb. Surg. 18, 837\u2013844 (2009).","journal-title":"J. Shoulder Elb. Surg."},{"key":"7119_CR28","doi-asserted-by":"publisher","first-page":"e1606","DOI":"10.3928\/01477447-20121023-17","volume":"35","author":"F Martetschl\u00e4ger","year":"2012","unstructured":"Martetschl\u00e4ger, F. et al. Plating of proximal humeral fractures. Orthopedics 35, e1606\u2013e1612 (2012).","journal-title":"Orthopedics"},{"key":"7119_CR29","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1186\/1471-2474-14-102","volume":"14","author":"WB Jung","year":"2013","unstructured":"Jung, W. B., Moon, E. S., Kim, S. K., Kovacevic, D. & Kim, M. S. Does medial support decrease major complications of unstable proximal humerus fractures treated with locking plate? BMC Musculoskelet. Disord. 14, 102 (2013).","journal-title":"BMC Musculoskelet. Disord"},{"key":"7119_CR30","doi-asserted-by":"publisher","first-page":"1283","DOI":"10.1016\/j.injury.2011.01.017","volume":"42","author":"D Krappinger","year":"2011","unstructured":"Krappinger, D. et al. Predicting failure after surgical fixation of proximal humerus fractures. Injury 42, 1283\u20131288 (2011).","journal-title":"Injury"},{"key":"7119_CR31","first-page":"1235","volume":"69","author":"J Lescheid","year":"2010","unstructured":"Lescheid, J., Zdero, R., Shah, S., Kuzyk, P. R. T. & Schemitsch, E. H. The biomechanics of locked plating for repairing proximal humerus fractures with or without medial cortical support. J. Trauma. 69, 1235\u20131242 (2010).","journal-title":"J. Trauma."},{"key":"7119_CR32","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1097\/BOT.0b013e318169ef2a","volume":"22","author":"KA Egol","year":"2008","unstructured":"Egol, K. A. et al. Early complications in proximal humerus fractures (OTA types 11) treated with locked plates. J. Orthop. Trauma. 22, 159\u2013164 (2008).","journal-title":"J. Orthop. Trauma."},{"key":"7119_CR33","doi-asserted-by":"publisher","first-page":"455","DOI":"10.2147\/TCRM.S131945","volume":"13","author":"A Moayeri","year":"2017","unstructured":"Moayeri, A. et al. Fracture risk in patients with type 2 diabetes mellitus and possible risk factors: a systematic review and meta-analysis. Ther. Clin. Risk Manag. 13, 455\u2013468 (2017).","journal-title":"Ther. Clin. Risk Manag"},{"key":"7119_CR34","first-page":"1465","volume":"36","author":"J Ma","year":"2022","unstructured":"Ma, J. et al. Effectiveness analysis of proximal humerus internal locking system plate combined with rotator cuff reinforcement suture in treatment of Neer type IV proximal humerus fracture. J. Reparative Reconstr. Surg. 36, 1465\u20131470 (2022).","journal-title":"J. Reparative Reconstr. Surg."},{"key":"7119_CR35","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1097\/BOT.0b013e3180333094","volume":"21","author":"MJ Gardner","year":"2007","unstructured":"Gardner, M. J. et al. The importance of medial support in locked plating of proximal humerus fractures. J. Orthop. Trauma. 21, 185\u2013191 (2007).","journal-title":"J. Orthop. Trauma."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-07119-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-07119-x","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-07119-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,2]],"date-time":"2025-07-02T02:59:39Z","timestamp":1751425179000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-07119-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,2]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["7119"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-07119-x","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,2]]},"assertion":[{"value":"11 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"This study followed the standards of the Declaration of Helsinki and was approved by the Ethics Committee of the General Hospital of Ningxia Medical University (KYLL-2024-1460).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all subjects and\/or their legal guardian(s).","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}],"article-number":"23081"}}