{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,26]],"date-time":"2026-02-26T20:07:10Z","timestamp":1772136430162,"version":"3.50.1"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,9]],"date-time":"2025-07-09T00:00:00Z","timestamp":1752019200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,7,9]],"date-time":"2025-07-09T00:00:00Z","timestamp":1752019200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-025-08340-4","type":"journal-article","created":{"date-parts":[[2025,7,10]],"date-time":"2025-07-10T08:48:34Z","timestamp":1752137314000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Light-adapted electroretinograms of eyes with cataract recorded using the HE-2000 system before and after mydriasis"],"prefix":"10.1038","volume":"15","author":[{"given":"Yoshiaki","family":"Chiku","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takao","family":"Hirano","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shun","family":"Ito","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Keita","family":"Akahane","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshinori","family":"Murata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,7,9]]},"reference":[{"key":"8340_CR1","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1007\/bf00212649","volume":"62","author":"RW Massof","year":"1986","unstructured":"Massof, R. W. et al. Flicker electroretinogram in retinitis pigmentosa. Doc. Ophthalmol. 62, 231\u2013245. https:\/\/doi.org\/10.1007\/bf00212649 (1986).","journal-title":"Doc. Ophthalmol."},{"key":"8340_CR2","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1016\/0042-6989(87)90025-3","volume":"27","author":"DG Birch","year":"1987","unstructured":"Birch, D. G. & Sandberg, M. A. Dependence of cone b-wave implicit time on rod amplitude in retinitis pigmentosa. Vision Res. 27, 1105\u20131112. https:\/\/doi.org\/10.1016\/0042-6989(87)90025-3 (1987).","journal-title":"Vision Res."},{"key":"8340_CR3","doi-asserted-by":"publisher","first-page":"500","DOI":"10.1016\/0002-9394(88)90241-3","volume":"105","author":"SO Andr\u00e9asson","year":"1988","unstructured":"Andr\u00e9asson, S. O. et al. Narrow-band filtering for monitoring low-amplitude cone electroretinograms in retinitis pigmentosa. Am. J. Ophthalmol. 105, 500\u2013503. https:\/\/doi.org\/10.1016\/0002-9394(88)90241-3 (1988).","journal-title":"Am. J. Ophthalmol."},{"key":"8340_CR4","doi-asserted-by":"publisher","first-page":"1699","DOI":"10.1016\/0042-6989(95)00246-4","volume":"36","author":"DC Hood","year":"1996","unstructured":"Hood, D. C. & Birch, D. G. Abnormalities of the retinal cone system in retinitis pigmentosa. Vision Res. 36, 1699\u20131709. https:\/\/doi.org\/10.1016\/0042-6989(95)00246-4 (1996).","journal-title":"Vision Res."},{"key":"8340_CR5","doi-asserted-by":"publisher","first-page":"660","DOI":"10.1001\/archopht.1987.01060050078042","volume":"105","author":"GH Bresnick","year":"1987","unstructured":"Bresnick, G. H. & Palta, M. Temporal aspects of the electroretinogram in diabetic retinopathy. Arch. Ophthalmol. 105, 660\u2013664. https:\/\/doi.org\/10.1001\/archopht.1987.01060050078042 (1987).","journal-title":"Arch. Ophthalmol."},{"key":"8340_CR6","first-page":"204","volume":"37","author":"K Tahara","year":"1993","unstructured":"Tahara, K. et al. Diagnostic evaluation of diabetic retinopathy by 30-Hz flicker electroretinography. Jpn. J. Ophthalmol. 37, 204\u2013210 (1993).","journal-title":"Jpn. J. Ophthalmol."},{"key":"8340_CR7","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1001\/archopht.1993.01090060094030","volume":"111","author":"MA Johnson","year":"1993","unstructured":"Johnson, M. A. & McPhee, T. J. Electroretinographic findings in iris neovascularization due to acute central retinal vein occlusion. Arch. Ophthalmol. 111, 806\u2013814. https:\/\/doi.org\/10.1001\/archopht.1993.01090060094030 (1993).","journal-title":"Arch. Ophthalmol."},{"key":"8340_CR8","doi-asserted-by":"publisher","first-page":"1123","DOI":"10.1001\/archopht.1993.01090080119027","volume":"111","author":"ML Severns","year":"1993","unstructured":"Severns, M. L. & Johnson, M. A. Predicting outcome in central retinal vein occlusion using the flicker electroretinogram. Arch. Ophthalmol. 111, 1123\u20131130. https:\/\/doi.org\/10.1001\/archopht.1993.01090080119027 (1993).","journal-title":"Arch. Ophthalmol."},{"key":"8340_CR9","doi-asserted-by":"publisher","first-page":"683","DOI":"10.1136\/bjo.85.6.683","volume":"85","author":"J Larsson","year":"2001","unstructured":"Larsson, J. & Andr\u00e9asson, S. Photopic 30 Hz flicker ERG as a predictor for rubeosis in central retinal vein occlusion. Br. J. Ophthalmol. 85, 683\u2013685. https:\/\/doi.org\/10.1136\/bjo.85.6.683 (2001).","journal-title":"Br. J. Ophthalmol."},{"key":"8340_CR10","doi-asserted-by":"publisher","first-page":"5737","DOI":"10.1167\/iovs.10-6923","volume":"52","author":"S Yasuda","year":"2011","unstructured":"Yasuda, S. et al. Significant correlation between electroretinogram parameters and ocular vascular endothelial growth factor concentration in central retinal vein occlusion eyes. Invest. Ophthalmol. Vis. Sci. 52, 5737\u20135742. https:\/\/doi.org\/10.1167\/iovs.10-6923 (2011).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"8340_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s10633-014-9473-7","volume":"130","author":"DL McCulloch","year":"2015","unstructured":"McCulloch, D. L. et al. ISCEV standard for full-field clinical electroretinography (2015 update). Doc. Ophthalmol. 130, 1\u201312. https:\/\/doi.org\/10.1007\/s10633-014-9473-7 (2015).","journal-title":"Doc. Ophthalmol."},{"key":"8340_CR12","doi-asserted-by":"publisher","first-page":"1024","DOI":"10.1097\/jcma.0000000000000794","volume":"85","author":"TM Kuang","year":"2022","unstructured":"Kuang, T. M. et al. Changes in intraocular pressure after pharmacological pupil dilatation in an elderly Chinese population in Taiwan: The Shihpai eye study. J. Chin. Med. Assoc. 85, 1024\u20131027. https:\/\/doi.org\/10.1097\/jcma.0000000000000794 (2022).","journal-title":"J. Chin. Med. Assoc."},{"key":"8340_CR13","doi-asserted-by":"publisher","first-page":"104","DOI":"10.5005\/jp-journals-10078-1261","volume":"13","author":"MC Yang","year":"2019","unstructured":"Yang, M. C. & Lin, K. Y. Drug-induced acute angle-closure glaucoma: a review. J. Curr. Glaucoma Pract. 13, 104\u2013109. https:\/\/doi.org\/10.5005\/jp-journals-10078-1261 (2019).","journal-title":"J. Curr. Glaucoma Pract."},{"key":"8340_CR14","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1016\/0165-0270(90)90147-8","volume":"32","author":"P Lachapelle","year":"1990","unstructured":"Lachapelle, P. & Blain, L. A new speculum electrode for electroretinography. J. Neurosci. Methods 32, 245\u2013249. https:\/\/doi.org\/10.1016\/0165-0270(90)90147-8 (1990).","journal-title":"J. Neurosci. Methods"},{"key":"8340_CR15","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1007\/s10633-019-09684-9","volume":"138","author":"X Ji","year":"2019","unstructured":"Ji, X. et al. Hand-held, dilation-free, electroretinography in children under 3 years of age treated with vigabatrin. Doc. Ophthalmol. 138, 195\u2013203. https:\/\/doi.org\/10.1007\/s10633-019-09684-9 (2019).","journal-title":"Doc. Ophthalmol."},{"key":"8340_CR16","doi-asserted-by":"publisher","first-page":"2180","DOI":"10.1038\/s41433-020-01221-2","volume":"35","author":"P Carter","year":"2021","unstructured":"Carter, P. et al. Comparison of the handheld RETeval ERG system with a routine ERG system in healthy adults and in pediatric patients. Eye (Lond) 35, 2180\u20132189. https:\/\/doi.org\/10.1038\/s41433-020-01221-2 (2021).","journal-title":"Eye (Lond)"},{"key":"8340_CR17","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1007\/s10633-004-1751-3","volume":"109","author":"K Bradshaw","year":"2004","unstructured":"Bradshaw, K. et al. Comparison of ERGs recorded with skin and corneal-contact electrodes in normal children and adults. Doc. Ophthalmol. 109, 43\u201355. https:\/\/doi.org\/10.1007\/s10633-004-1751-3 (2004).","journal-title":"Doc. Ophthalmol."},{"key":"8340_CR18","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.2147\/OPTH.S104721","volume":"10","author":"N Nakamura","year":"2016","unstructured":"Nakamura, N. et al. Evaluation of cone function by a handheld non-mydriatic flicker electroretinogram device. Clin. Ophthalmol. 10, 1175\u20131185. https:\/\/doi.org\/10.2147\/OPTH.S104721 (2016).","journal-title":"Clin. Ophthalmol."},{"key":"8340_CR19","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1007\/s10633-007-9065-x","volume":"116","author":"ES Papathanasiou","year":"2008","unstructured":"Papathanasiou, E. S. & Papacostas, S. S. Flash electroretinography: normative values with surface skin electrodes and no pupil dilation using a standard stimulation protocol. Doc. Ophthalmol. 116, 61\u201373. https:\/\/doi.org\/10.1007\/s10633-007-9065-x (2008).","journal-title":"Doc. Ophthalmol."},{"key":"8340_CR20","unstructured":"Skin Electrode Electroretinogram, HE-2000. Available at http:\/\/www.ritz-med.co.jp\/info\/wp-content\/uploads\/2021\/02\/HE-2000.pdf."},{"key":"8340_CR21","doi-asserted-by":"publisher","first-page":"317","DOI":"10.1007\/s10792-016-0240-5","volume":"37","author":"T Yamashita","year":"2017","unstructured":"Yamashita, T. et al. A novel method to reduce noise in electroretinography using skin electrodes: A study of noise level, inter-session variability, and reproducibility. Int. Ophthalmol. 37, 317\u2013324. https:\/\/doi.org\/10.1007\/s10792-016-0240-5 (2017).","journal-title":"Int. Ophthalmol."},{"key":"8340_CR22","doi-asserted-by":"publisher","first-page":"3684","DOI":"10.1167\/iovs.14-16349","volume":"56","author":"K Kato","year":"2015","unstructured":"Kato, K. et al. Effect of pupil size on flicker ERGs recorded with RETeval system: New mydriasis-free full-field ERG system. Invest. Ophthalmol. Vis. Sci. 56, 3684\u20133690. https:\/\/doi.org\/10.1167\/iovs.14-16349 (2015).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"8340_CR23","doi-asserted-by":"publisher","first-page":"1405","DOI":"10.1016\/s0042-6989(03)00118-4","volume":"43","author":"M Rufiange","year":"2003","unstructured":"Rufiange, M. et al. The photopic ERG luminance-response function (photopic hill): Method of analysis and clinical application. Vision Res. 43, 1405\u20131412. https:\/\/doi.org\/10.1016\/s0042-6989(03)00118-4 (2003).","journal-title":"Vision Res."},{"key":"8340_CR24","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s12886-016-0200-x","volume":"16","author":"G Miura","year":"2016","unstructured":"Miura, G. et al. Effects of cataracts on flicker electroretinograms recorded with RETeval system: New mydriasis-free ERG device. BMC Ophthalmol. 16, 22. https:\/\/doi.org\/10.1186\/s12886-016-0200-x (2016).","journal-title":"BMC Ophthalmol."},{"key":"8340_CR25","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1007\/s10633-017-9572-3","volume":"134","author":"CQ Davis","year":"2017","unstructured":"Davis, C. Q. et al. Constant luminance (cd.s\/m2) versus constant retinal illuminance (Td.s) stimulation in flicker ERGs. Doc. Ophthalmol. 134, 75\u201387. https:\/\/doi.org\/10.1007\/s10633-017-9572-3 (2017).","journal-title":"Doc. Ophthalmol."},{"key":"8340_CR26","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1111\/aos.14618","volume":"99","author":"A Sugawara","year":"2021","unstructured":"Sugawara, A. et al. Effects of recording sequence on flicker electroretinographics recorded with natural pupils corrected for pupil area. Acta Ophthalmol. 99, 411\u2013417. https:\/\/doi.org\/10.1111\/aos.14618 (2021).","journal-title":"Acta Ophthalmol."},{"key":"8340_CR27","unstructured":"Emery, J. M. & Little, J. H. Phacoemulsification and Aspiration of Cataracts: Surgical Techniques, Complications, and Results. 45\u201348 (St. Louis, Mosby, 1979)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-08340-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-08340-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-08340-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,10]],"date-time":"2025-07-10T08:48:36Z","timestamp":1752137316000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-08340-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,9]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["8340"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-08340-4","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-5315258\/v1","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,9]]},"assertion":[{"value":"23 October 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Takao Hirano received personal fees from Novartis Pharma K.K., Bayer, Canon, Kowa Pharmaceutical, Senju Pharmaceutical, Chugai Pharmaceutical, and Santen Phar-maceutical. Toshinori Murata received personal fees from Novartis Pharma K.K., Bayer, Canon, Kowa Pharmaceutical, Senju Pharmaceutical, Chugai Pharmaceutical, Kyowa Kirin, and Santen Pharmaceutical. Other authors have no conflicts of interest to disclose.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"This study was a retrospective review of hospital medical records and was conducted in accordance with the principles outlined in the Declaration of Helsinki. The study protocol was approved by the Ethics Committee of Suwa Red Cross Hospital (approval no. 4-3). Informed consent was waived by the Ethics Committee, as the research involved a retrospective analysis of de-identified patient data without any intervention that would affect patient care. In line with the ethics committee\u2019s directives, an opt-out option was made available on the hospital\u2019s website.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}],"article-number":"24695"}}