{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T16:10:18Z","timestamp":1792858218437,"version":"4.5.0"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,8]],"date-time":"2025-07-08T00:00:00Z","timestamp":1751932800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,8]],"date-time":"2025-07-08T00:00:00Z","timestamp":1751932800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Antibiotic optimisation through therapeutic drug monitoring (TDM) is a key strategy in tackling antimicrobial resistance. However, current quantification methods rely on laboratory-based equipment, delaying timely dose adjustments. We developed a novel point-of-care lateral flow assay (LFA) for the quantification of vancomycin in serum. Unlike conventional LFAs with a single test and control line, this assay incorporates two test lines: one for vancomycin binding and one for avidin capture of excess conjugate. Gold nanoparticles were conjugated to biotinylated bovine serum albumin\u2013vancomycin, enabling competitive binding with anti-vancomycin antibodies and avidin capture. Signal ratios from smartphone-acquired images were quantified using an automated image analysis algorithm. Applied to vancomycin in serum, the LFA demonstrated a quantitative detection range of 2.88 to 45,000 ng\/mL, with good accuracy, reproducibility, and high recovery in spiked samples. This approach offers a promising solution for decentralised, rapid TDM in clinical settings, especially where timely dose optimisation is critical.<\/jats:p>","DOI":"10.1038\/s41598-025-09145-1","type":"journal-article","created":{"date-parts":[[2025,7,8]],"date-time":"2025-07-08T04:40:21Z","timestamp":1751949621000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Development of a novel quantitative lateral flow assay for vancomycin for therapeutic drug monitoring"],"prefix":"10.1038","volume":"15","author":[{"given":"Alaa","family":"Riezk","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vasin","family":"Vasikasin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard C.","family":"Wilson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy M.","family":"Rawson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony E. G.","family":"Cass","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alison H.","family":"Holmes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,8]]},"reference":[{"issue":"10459","key":"9145_CR1","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1016\/S0140-6736(24)01867-1","volume":"404","author":"GBDAR Collaborators","year":"2024","unstructured":"Collaborators, G. B. D. A. R. Global burden of bacterial antimicrobial resistance 1990\u20132021: a systematic analysis with forecasts to 2050. Lancet 404 (10459), 1199\u20131226 (2024).","journal-title":"Lancet"},{"issue":"12","key":"9145_CR2","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1038\/s41579-021-00578-9","volume":"19","author":"TM Rawson","year":"2021","unstructured":"Rawson, T. M. et al. Optimizing antimicrobial use: challenges, advances and opportunities. Nat. Rev. Microbiol. 19 (12), 747\u2013758 (2021).","journal-title":"Nat. Rev. Microbiol."},{"issue":"11","key":"9145_CR3","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1093\/ajhp\/zxaa036","volume":"77","author":"MJ Rybak","year":"2020","unstructured":"Rybak, M. J. et al. Therapeutic monitoring of Vancomycin for serious methicillin-resistant Staphylococcus aureus infections: A revised consensus guideline and review by the American society of Health-System pharmacists, the infectious diseases society of america, the pediatric infectious diseases society, and the society of infectious diseases pharmacists. Am. J. Health Syst. Pharm. 77 (11), 835\u2013864 (2020).","journal-title":"Am. J. Health Syst. Pharm."},{"key":"9145_CR4","doi-asserted-by":"crossref","unstructured":"Rose, W., Volk, C., Dilworth, T. J. & Sakoulas, G. Approaching 65 years: is it time to consider retirement of vancomycin for treating methicillin-resistant Staphylococcus aureus endovascular infections?? Open. Forum Infect. Dis. 9 (5). (2022).","DOI":"10.1093\/ofid\/ofac137"},{"issue":"5","key":"9145_CR5","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1007\/s10096-019-03769-8","volume":"39","author":"C Mabilat","year":"2020","unstructured":"Mabilat, C. et al. Diagnostic and medical needs for therapeutic drug monitoring of antibiotics. Eur. J. Clin. Microbiol. Infect. Dis. 39 (5), 791\u2013797 (2020).","journal-title":"Eur. J. Clin. Microbiol. Infect. Dis."},{"key":"9145_CR6","doi-asserted-by":"publisher","first-page":"763686","DOI":"10.3389\/fchem.2021.763686","volume":"9","author":"L Bian","year":"2021","unstructured":"Bian, L. et al. Rapid monitoring of Vancomycin concentration in serum using europium (III) chelate Nanoparticle-Based lateral flow immunoassay. Front. Chem. 9, 763686 (2021).","journal-title":"Front. Chem."},{"issue":"3","key":"9145_CR7","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1007\/s12223-019-00752-w","volume":"65","author":"E Klapkova","year":"2020","unstructured":"Klapkova, E. et al. Vancomycin and its crystalline degradation products released from bone grafts and different types of bone cement. Folia Microbiol. (Praha)  65 (3), 475\u2013482 (2020).","journal-title":"Folia Microbiol. (Praha)"},{"key":"9145_CR8","doi-asserted-by":"crossref","unstructured":"Calucho, E., Parolo, C., Rivas, L., \u00c1lvarez-Diduk, R. & Merko\u00e7i, A. Chapter Ten - Nanoparticle-based lateral flow assays. In Comprehensive Analytical Chemistry (ed Merko\u00e7i, A.)  89,  313\u2013359. (Elsevier, 2020).","DOI":"10.1016\/bs.coac.2020.04.011"},{"issue":"3","key":"9145_CR9","doi-asserted-by":"publisher","first-page":"3593","DOI":"10.1021\/acsnano.0c10035","volume":"15","author":"Y Liu","year":"2021","unstructured":"Liu, Y., Zhan, L., Qin, Z., Sackrison, J. & Bischof, J. C. Ultrasensitive and highly specific lateral flow assays for Point-of-Care diagnosis. ACS Nano. 15 (3), 3593\u20133611 (2021).","journal-title":"ACS Nano"},{"issue":"3","key":"9145_CR10","doi-asserted-by":"publisher","first-page":"89","DOI":"10.3390\/bios9030089","volume":"9","author":"AE Urusov","year":"2019","unstructured":"Urusov, A. E., Zherdev, A. V. & Dzantiev, B. B. Towards lateral flow quantitative assays: detection approaches. Biosens. (Basel). 9 (3), 89 (2019).","journal-title":"Biosens. (Basel)"},{"issue":"3","key":"9145_CR11","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1007\/s11418-022-01605-6","volume":"76","author":"P Nuntawong","year":"2022","unstructured":"Nuntawong, P., Putalun, W., Tanaka, H., Morimoto, S. & Sakamoto, S. Lateral flow immunoassay for small-molecules detection in phytoproducts: a review. J. Nat. Med. 76 (3), 521\u2013545 (2022).","journal-title":"J. Nat. Med."},{"issue":"6","key":"9145_CR12","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1016\/j.jscs.2014.09.001","volume":"19","author":"M Sajid","year":"2015","unstructured":"Sajid, M., Kawde, A-N. & Daud, M. Designs, formats and applications of lateral flow assay: A literature review. J. Saudi Chem. Soc. 19 (6), 689\u2013705 (2015).","journal-title":"J. Saudi Chem. Soc."},{"issue":"3","key":"9145_CR13","doi-asserted-by":"publisher","first-page":"e0213859","DOI":"10.1371\/journal.pone.0213859","volume":"14","author":"MJ Jacinto","year":"2019","unstructured":"Jacinto, M. J. et al. Correction: Enhancement of lateral flow assay performance by electromagnetic relocation of reporter particles. PLOS ONE. 14 (3), e0213859 (2019).","journal-title":"PLOS ONE"},{"issue":"3","key":"9145_CR14","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1177\/0897190016642692","volume":"30","author":"CM Hale","year":"2017","unstructured":"Hale, C. M., Seabury, R. W., Steele, J. M., Darko, W. & Miller, C. D. Are Vancomycin trough concentrations of 15 to 20\u00a0mg\/l associated with increased attainment of an AUC\/MIC >\/= 400 in patients with presumed MRSA infection?? J. Pharm. Pract. 30 (3), 329\u2013335 (2017).","journal-title":"J. Pharm. Pract."},{"issue":"3","key":"9145_CR15","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1080\/09540105.2017.1293014","volume":"28","author":"D Kong","year":"2017","unstructured":"Kong, D. et al. Development of ic-ELISA and lateral-flow immunochromatographic assay strip for the detection of Vancomycin in Raw milk and animal feed. Food Agricultural Immunol. 28 (3), 414\u2013426 (2017).","journal-title":"Food Agricultural Immunol."},{"key":"9145_CR16","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1186\/s40064-015-1411-y","volume":"4","author":"JC Odekerken","year":"2015","unstructured":"Odekerken, J. C. et al. ELISA-based detection of gentamicin and Vancomycin in protein-containing samples. Springerplus 4, 614 (2015).","journal-title":"Springerplus"},{"key":"9145_CR17","doi-asserted-by":"publisher","first-page":"21","DOI":"10.3390\/foods13213477","volume":"13","author":"Q Xie","year":"2024","unstructured":"Xie, Q., Huang, Y., Zhang, X., Xu, X. & Li, Z. Development of an indirect competitive ELISA based on a stable epitope of \u03b2-Lactoglobulin for its detection in hydrolyzed formula milk powder. Foods 13, 21 (2024).","journal-title":"Foods"},{"issue":"2","key":"9145_CR18","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1111\/j.1432-1033.1990.tb15569.x","volume":"190","author":"Y von Boxberg","year":"1990","unstructured":"von Boxberg, Y., W\u00fctz, R. & Schwarz, U. Use of the biotin-avidin system for labelling, isolation and characterization of neural cell-surface proteins. Eur. J. Biochem. 190 (2), 249\u2013256 (1990).","journal-title":"Eur. J. Biochem."},{"issue":"14","key":"9145_CR19","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.4155\/bio-2017-0059","volume":"9","author":"A De Nicolo","year":"2017","unstructured":"De Nicolo, A., Cantu, M. & D\u2019Avolio, A. Matrix effect management in liquid chromatography mass spectrometry: the internal standard normalized matrix effect. Bioanalysis 9 (14), 1093\u20131105 (2017).","journal-title":"Bioanalysis"},{"key":"9145_CR20","doi-asserted-by":"crossref","unstructured":"De Nicol\u00f2, A., Cantu, M. & D\u2019Avolio, A. Matrix effect management in liquid chromatography mass spectrometry: the internal standard normalized matrix effect. Bioanalysis 9  (2017).","DOI":"10.4155\/bio-2017-0059"},{"issue":"12","key":"9145_CR21","doi-asserted-by":"publisher","first-page":"6781","DOI":"10.1021\/acs.analchem.7b01149","volume":"89","author":"TT Le","year":"2017","unstructured":"Le, T. T. et al. Dual recognition element lateral flow assay toward multiplex strain specific influenza virus detection. Anal. Chem. 89 (12), 6781\u20136786 (2017).","journal-title":"Anal. Chem."},{"issue":"7","key":"9145_CR22","doi-asserted-by":"publisher","first-page":"979","DOI":"10.1093\/bioinformatics\/btq046","volume":"26","author":"G Pau","year":"2010","unstructured":"Pau, G., Fuchs, F., Sklyar, O., Boutros, M. & Huber, W. EBImage\u2014an R package for image processing with applications to cellular phenotypes. Bioinformatics 26 (7), 979\u2013981 (2010).","journal-title":"Bioinformatics"},{"issue":"6","key":"9145_CR23","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1039\/D2AY01276F","volume":"15","author":"A Riezk","year":"2023","unstructured":"Riezk, A. et al. A rapid, simple, high-performance liquid chromatography method for the clinical measurement of beta-lactam antibiotics in serum and interstitial fluid. Anal. Methods  15 (6), 829\u2013836 (2023).","journal-title":"Anal. Methods"},{"issue":"6","key":"9145_CR24","doi-asserted-by":"publisher","first-page":"746","DOI":"10.1039\/D2AY01459A","volume":"15","author":"A Riezk","year":"2023","unstructured":"Riezk, A. et al. Triple quadrupole LC\/MS method for the simultaneous quantitative measurement of Cefiderocol and meropenem in serum. Anal. Methods  15 (6), 746\u2013751 (2023).","journal-title":"Anal. Methods"},{"issue":"14","key":"9145_CR25","doi-asserted-by":"publisher","first-page":"1451","DOI":"10.4155\/bio-2016-0053","volume":"8","author":"T Verch","year":"2016","unstructured":"Verch, T., Christopher, R. & Shank-Retzlaff, M. Reduction of Dilution error in Elisas using an internal standard. Bioanalysis 8 (14), 1451\u20131464 (2016).","journal-title":"Bioanalysis"},{"issue":"17\u201318","key":"9145_CR26","doi-asserted-by":"publisher","first-page":"923","DOI":"10.1080\/17576180.2024.2352253","volume":"16","author":"W Li","year":"2024","unstructured":"Li, W., Yunlin, F. & Picard, F. Inclusion of Dilution quality control samples in quantitative LC-MS bioanalysis. Bioanalysis 16 (17\u201318), 923\u2013925 (2024).","journal-title":"Bioanalysis"},{"issue":"6","key":"9145_CR27","doi-asserted-by":"publisher","first-page":"6261","DOI":"10.1021\/acsnano.7b02466","volume":"11","author":"M You","year":"2017","unstructured":"You, M. et al. Household fluorescent lateral flow strip platform for sensitive and quantitative prognosis of heart failure using Dual-Color upconversion nanoparticles. ACS Nano. 11 (6), 6261\u20136270 (2017).","journal-title":"ACS Nano"},{"issue":"46","key":"9145_CR28","doi-asserted-by":"publisher","first-page":"40671","DOI":"10.1021\/acsami.7b12734","volume":"9","author":"N Cheng","year":"2017","unstructured":"Cheng, N. et al. Nanozyme-Mediated dual immunoassay integrated with smartphone for use in simultaneous detection of pathogens. ACS Appl. Mater. Interfaces. 9 (46), 40671\u201340680 (2017).","journal-title":"ACS Appl. Mater. Interfaces"},{"issue":"17","key":"9145_CR29","doi-asserted-by":"publisher","first-page":"8908","DOI":"10.1021\/acs.analchem.7b01379","volume":"89","author":"X Li","year":"2017","unstructured":"Li, X., Yang, F., Wong, J. X. H. & Yu, H. Z. Integrated Smartphone-App-Chip system for On-Site Parts-Per-Billion-Level colorimetric quantitation of aflatoxins. Anal. Chem. 89 (17), 8908\u20138916 (2017).","journal-title":"Anal. Chem."},{"key":"9145_CR30","doi-asserted-by":"publisher","first-page":"28645","DOI":"10.1038\/srep28645","volume":"6","author":"TF Scherr","year":"2016","unstructured":"Scherr, T. F., Gupta, S., Wright, D. W. & Haselton, F. R. Mobile phone imaging and cloud-based analysis for standardized malaria detection and reporting. Sci. Rep. 6, 28645 (2016).","journal-title":"Sci. Rep."},{"key":"9145_CR31","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.snb.2018.03.110","volume":"266","author":"W Xiao","year":"2018","unstructured":"Xiao, W. et al. A simple and compact smartphone-based device for the quantitative readout of colloidal gold lateral flow immunoassay strips. Sens. Actuators B Chem. 266, 63\u201370 (2018).","journal-title":"Sens. Actuators B Chem."},{"issue":"2","key":"9145_CR32","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1007\/s00604-018-3195-6","volume":"186","author":"C Ruppert","year":"2019","unstructured":"Ruppert, C., Phogat, N., Laufer, S., Kohl, M. & Deigner, H. P. A smartphone readout system for gold nanoparticle-based lateral flow assays: application to monitoring of Digoxigenin. Mikrochim Acta. 186 (2), 119 (2019).","journal-title":"Mikrochim Acta"},{"issue":"18","key":"9145_CR33","doi-asserted-by":"publisher","first-page":"9629","DOI":"10.1021\/acs.analchem.7b03017","volume":"89","author":"E Guler","year":"2017","unstructured":"Guler, E. et al. Mobile phone sensing of cocaine in a lateral flow assay combined with a biomimetic material. Anal. Chem. 89 (18), 9629\u20139632 (2017).","journal-title":"Anal. Chem."},{"key":"9145_CR34","doi-asserted-by":"crossref","unstructured":"Saisin, L. et al. Significant sensitivity improvement for camera-based lateral flow immunoassay readers. Sens. (Basel) 18 (11). (2018).","DOI":"10.3390\/s18114026"},{"issue":"21","key":"9145_CR35","doi-asserted-by":"publisher","first-page":"17723","DOI":"10.1021\/acsomega.2c00793","volume":"7","author":"JH Park","year":"2022","unstructured":"Park, J. H., Park, E. K., Cho, Y. K., Shin, I. S. & Lee, H. Normalizing the optical signal enables robust assays with lateral flow biosensors. ACS Omega. 7 (21), 17723\u201317731 (2022).","journal-title":"ACS Omega"},{"issue":"10","key":"9145_CR36","doi-asserted-by":"publisher","first-page":"3314","DOI":"10.1039\/C9AN00374F","volume":"144","author":"Z Li","year":"2019","unstructured":"Li, Z., Chen, H. & Wang, P. Lateral flow assay ruler for quantitative and rapid point-of-care testing. Analyst 144 (10), 3314\u20133322 (2019).","journal-title":"Analyst"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-09145-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-09145-1","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-09145-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,8]],"date-time":"2025-07-08T04:40:24Z","timestamp":1751949624000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-09145-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,8]]},"references-count":36,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["9145"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-09145-1","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,8]]},"assertion":[{"value":"30 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"VV has received honoraria from Takeda (2024), Pfizer (2024) and MSD (2024). TMR has received honoraria from Sandoz (2020), BioMerieux (2021-2024), Pfizer (2024), and Roche Diagnostics (2021). All other authors declare no competing interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"24398"}}