{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T18:42:32Z","timestamp":1790707352915,"version":"4.1.0"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,8,9]],"date-time":"2025-08-09T00:00:00Z","timestamp":1754697600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,8,9]],"date-time":"2025-08-09T00:00:00Z","timestamp":1754697600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>A humeral locking plate augmented with fibular strut allograft treated for proximal humeral fracture without internal structural support is satisfactory. While it is better clinically and biomechanically than the locking plate alone, it has disadvantages, including difficulty to obtain and the possibility of infection. Other alternative augmentation approaches are in demand. Therefore, the hypothesis of this study is whether intramedullary strut plate can replace fibular strut allograft as a surgical method while providing similar biomechanical performance. The finite element analysis (FEA) models were established based on three-dimensional computed tomography images. Computer-aided design implants were incorporated into the models. According to different implants, models were divided into four groups: the intact humerus, humeral locking plate alone (LP), humeral locking plate augmented with fibular strut allograft (FA), and humeral locking plate augmented with intramedullary strut plate (IMP). The displacements and von Mises stresses were measured on the models by simulating axial force, oblique force and torsion. Compared with the LP group, the displacements and von Mises stresses on the humerus and humeral locking plate in the FA, and IMP groups were all smaller in axial force, oblique force, and torsion. The biomechanical effects of FA and IMP in proximal humeral fracture without internal structural support were basically similar in terms of axial force, oblique force, and torsion. Findings provide useful new ideas for implant design. Our FEA simulation indicates that both the fibular strut allograft (FA) and intramedullary strut plate (IMP) offer similar biomechanical stability in treating proximal humeral fractures without internal structural support. This supports the hypothesis that the intramedullary strut plate can effectively replace the fibular strut allograft.<\/jats:p>","DOI":"10.1038\/s41598-025-09848-5","type":"journal-article","created":{"date-parts":[[2025,8,9]],"date-time":"2025-08-09T16:13:43Z","timestamp":1754756023000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Biomechanics of humeral locking plate augmented with fibular strut allograft and intramedullary strut plate using finite element analysis"],"prefix":"10.1038","volume":"15","author":[{"given":"Cheng-Hung","family":"Lee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li-Kun","family":"Hung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yu-Chun","family":"Yen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuo-Chih","family":"Su","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,8,9]]},"reference":[{"key":"9848_CR1","first-page":"330","volume":"42","author":"D Karataglis","year":"2011","unstructured":"Karataglis, D., Stavridis, S. I., Petsatodis, G., Papadopoulos, P. & Christodoulou, A. New trends in fixation of proximal humeral fractures: A review. Inj. 42, 330\u2013338 (2011).","journal-title":"Inj."},{"key":"9848_CR2","first-page":"312","volume":"44","author":"J Newman","year":"2015","unstructured":"Newman, J., Kahn, M. & Gruson, K. I. Reducing postoperative fracture displacement after locked plating of proximal humerus fractures: Current concepts. Am. J. Orthop. 44, 312\u2013320 (2015).","journal-title":"Am. J. Orthop."},{"key":"9848_CR3","doi-asserted-by":"publisher","first-page":"251","DOI":"10.2106\/JBJS.L.01293","volume":"96","author":"D Maier","year":"2014","unstructured":"Maier, D., Jaeger, M., Izadpanah, K., Strohm, P. C. & Suedkamp, N. P. Proximal humeral fracture treatment in adults. JBJS 96, 251\u2013261 (2014).","journal-title":"JBJS"},{"key":"9848_CR4","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.RVW.O.00003","volume":"4","author":"A Jawa","year":"2016","unstructured":"Jawa, A. & Burnikel, D. Treatment of proximal humeral fractures: A critical analysis review. JBJS Rev. 4, e2 (2016).","journal-title":"JBJS Rev."},{"key":"9848_CR5","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1007\/s00776-009-1382-3","volume":"14","author":"ID Micic","year":"2009","unstructured":"Micic, I. D. et al. Analysis of early failure of the locking compression plate in osteoporotic proximal humerus fractures. J. Orthop. Sci. 14, 596\u2013601 (2009).","journal-title":"J. Orthop. Sci."},{"key":"9848_CR6","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1097\/BOT.0b013e31815b3922","volume":"22","author":"MJ Gardner","year":"2008","unstructured":"Gardner, M. J., Boraiah, S., Helfet, D. L. & Lorich, D. G. Indirect medial reduction and strut support of proximal humerus fractures using an endosteal implant. J. Orthop. Trauma 22, 195\u2013200 (2008).","journal-title":"J. Orthop. Trauma"},{"key":"9848_CR7","first-page":"460","volume":"36","author":"MJ Gardner","year":"2007","unstructured":"Gardner, M. J., Lorich, D. G., Werner, C. & Helfet, D. L. Second-generation concepts for locked plating of proximal humerus fractures. Am. J. Orthop. (Belle Mead. NJ) 36, 460\u2013465 (2007).","journal-title":"Am. J. Orthop. (Belle Mead. NJ)"},{"key":"9848_CR8","doi-asserted-by":"publisher","first-page":"884","DOI":"10.1016\/j.jse.2021.11.004","volume":"31","author":"SP Dasari","year":"2022","unstructured":"Dasari, S. P. et al. Improved outcomes for proximal humerus fracture open reduction internal fixation augmented with a fibular allograft in elderly patients: a systematic review and meta-analysis. J. Shoulder Elbow Surg. 31, 884\u2013894 (2022).","journal-title":"J. Shoulder Elbow Surg."},{"key":"9848_CR9","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1007\/s00402-020-03604-2","volume":"142","author":"Y-K Kim","year":"2022","unstructured":"Kim, Y.-K., Kang, S.-W., Jung, K.-H. & Oh, Y.-K. The potential of locking plate with intramedullary fibular allograft to manage proximal humeral fracture with an unstable medial column. Arch. Orthop. Trauma Surg. 142, 91\u201397 (2022).","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"9848_CR10","first-page":"186","volume":"35","author":"D Tang","year":"2022","unstructured":"Tang, D., Zhong, H.-Z. & Liang, K.-L. Locking plate fixation with fibular strut allograft versus locking plate fixation alone for the treatment of proximal humeral fractures in adults: A meta-analysis. Zhongguo Gu Shang 35, 186\u2013193 (2022).","journal-title":"Zhongguo Gu Shang"},{"key":"9848_CR11","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1302\/0301-620X.93B7.26125","volume":"93","author":"J-H Bae","year":"2011","unstructured":"Bae, J.-H. et al. The biomechanical performance of locking plate fixation with intramedullary fibular strut graft augmentation in the treatment of unstable fractures of the proximal humerus. J. Bone Joint Surg. Br. 93, 937\u2013941 (2011).","journal-title":"J. Bone Joint Surg. Br."},{"key":"9848_CR12","doi-asserted-by":"publisher","first-page":"642","DOI":"10.1016\/j.clinbiomech.2010.04.006","volume":"25","author":"C Mathison","year":"2010","unstructured":"Mathison, C. et al. Biomechanical analysis of proximal humeral fixation using locking plate fixation with an intramedullary fibular allograft. Clin. Biomech. 25, 642\u2013646 (2010).","journal-title":"Clin. Biomech."},{"key":"9848_CR13","doi-asserted-by":"publisher","first-page":"1350055","DOI":"10.1142\/S0219519413500553","volume":"13","author":"C-H Lee","year":"2013","unstructured":"Lee, C.-H. et al. Biomechanical comparison of the role of inlay graft in proximal humerus fracture fixed with conventional plate and locking plate. J. Mech. Med. Biol. 13, 1350055 (2013).","journal-title":"J. Mech. Med. Biol."},{"key":"9848_CR14","first-page":"484","volume":"14","author":"R Zamborsky","year":"2016","unstructured":"Zamborsky, R., Svec, A., Bohac, M., Kilian, M. & Kokavec, M. Infection in bone allograft transplants. Exp. Clin. Transplant. 14, 484\u2013490 (2016).","journal-title":"Exp. Clin. Transplant."},{"key":"9848_CR15","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.jhin.2021.10.020","volume":"123","author":"N Baseri","year":"2022","unstructured":"Baseri, N., Meysamie, A., Campanile, F., Hamidieh, A. & Jafarian, A. Bacterial contamination of bone allografts in the tissue banks: A systematic review and meta-analysis. J. Hosp. Infect. 123, 156\u2013173 (2022).","journal-title":"J. Hosp. Infect."},{"key":"9848_CR16","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1097\/BTH.0000000000000260","volume":"24","author":"JE Manzi","year":"2020","unstructured":"Manzi, J. E. et al. Failed proximal humerus osteosynthesis using intramedullary fibular strut allograft conversion to reverse shoulder arthroplasty. Tech. Hand Up. Extrem. Surg. 24, 7\u201312 (2020).","journal-title":"Tech. Hand Up. Extrem. Surg."},{"key":"9848_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13018-017-0573-4","volume":"12","author":"Y He","year":"2017","unstructured":"He, Y., Zhang, Y., Wang, Y., Zhou, D. & Wang, F. Biomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support. J. Orthop. Surg. Res. 12, 1\u201310 (2017).","journal-title":"J. Orthop. Surg. Res."},{"key":"9848_CR18","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12938-017-0432-x","volume":"17","author":"A Jabran","year":"2018","unstructured":"Jabran, A., Peach, C. & Ren, L. Biomechanical analysis of plate systems for proximal humerus fractures: A systematic literature review. Biomed. Eng. Online 17, 1\u201330 (2018).","journal-title":"Biomed. Eng. Online"},{"key":"9848_CR19","doi-asserted-by":"publisher","first-page":"1816","DOI":"10.1016\/j.jse.2019.02.013","volume":"28","author":"JW Fletcher","year":"2019","unstructured":"Fletcher, J. W., Windolf, M., Richards, R. G., Gueorguiev, B. & Varga, P. Screw configuration in proximal humerus plating has a significant impact on fixation failure risk predicted by finite element models. J. Shoulder Elbow Surg. 28, 1816\u20131823 (2019).","journal-title":"J. Shoulder Elbow Surg."},{"key":"9848_CR20","doi-asserted-by":"publisher","first-page":"4349","DOI":"10.3390\/app10124349","volume":"10","author":"TS Goh","year":"2020","unstructured":"Goh, T. S., Lim, B.-Y., Lee, J. S. & Lee, C.-S. Identification of surgical plan for syndesmotic fixation procedure based on finite element method. Appl. Sci. 10, 4349 (2020).","journal-title":"Appl. Sci."},{"key":"9848_CR21","doi-asserted-by":"publisher","DOI":"10.1097\/MD.0000000000001775","volume":"94","author":"Y He","year":"2015","unstructured":"He, Y. et al. Application of additional medial plate in treatment of proximal humeral fractures with unstable medial column: A finite element study and clinical practice. Medicine 94, e1775 (2015).","journal-title":"Medicine"},{"key":"9848_CR22","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0080236","volume":"8","author":"Q Liu","year":"2013","unstructured":"Liu, Q. et al. Analysis of the stress and displacement distribution of inferior tibiofibular syndesmosis injuries repaired with screw fixation: a finite element study. PLoS ONE 8, e80236 (2013).","journal-title":"PLoS ONE"},{"key":"9848_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12891-017-1421-8","volume":"18","author":"C-K Hsiao","year":"2017","unstructured":"Hsiao, C.-K. et al. Intramedullary cortical bone strut improves the cyclic stability of osteoporotic proximal humeral fractures. BMC Musculoskelet. Disord. 18, 1\u20137 (2017).","journal-title":"BMC Musculoskelet. Disord."},{"key":"9848_CR24","doi-asserted-by":"publisher","first-page":"335","DOI":"10.3390\/sym10080335","volume":"10","author":"JA L\u00f3pez-Campos","year":"2018","unstructured":"L\u00f3pez-Campos, J. A. et al. Finite element study of a threaded fastening: the case of surgical screws in bone. Symmetry 10, 335 (2018).","journal-title":"Symmetry"},{"key":"9848_CR25","doi-asserted-by":"publisher","first-page":"1836","DOI":"10.1016\/j.jbiomech.2016.04.021","volume":"49","author":"JA Inzana","year":"2016","unstructured":"Inzana, J. A., Varga, P. & Windolf, M. Implicit modeling of screw threads for efficient finite element analysis of complex bone-implant systems. J. Biomech. 49, 1836\u20131844 (2016).","journal-title":"J. Biomech."},{"key":"9848_CR26","doi-asserted-by":"publisher","first-page":"1425643","DOI":"10.3389\/fbioe.2024.1425643","volume":"12","author":"Y Lv","year":"2024","unstructured":"Lv, Y. et al. Finite element analysis and biomechanical study of \u201csandwich\u201d fixation in the treatment of elderly proximal humerus fractures. Front. Bioeng. Biotechnol. 12, 1425643 (2024).","journal-title":"Front. Bioeng. Biotechnol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-09848-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-09848-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-09848-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T22:37:02Z","timestamp":1757371022000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-09848-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,9]]},"references-count":26,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["9848"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-09848-5","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,9]]},"assertion":[{"value":"22 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 June 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"29211"}}