{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T11:11:14Z","timestamp":1769080274836,"version":"3.49.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,22]],"date-time":"2025-07-22T00:00:00Z","timestamp":1753142400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,7,22]],"date-time":"2025-07-22T00:00:00Z","timestamp":1753142400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-025-12183-4","type":"journal-article","created":{"date-parts":[[2025,7,22]],"date-time":"2025-07-22T07:02:44Z","timestamp":1753167764000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Advancing forensic accuracy: mitigating methemoglobin interference in postmortem carbon monoxide analysis using sodium dithionite reduction"],"prefix":"10.1038","volume":"15","author":[{"given":"Miyeon","family":"Lee","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Doyeon","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young-Hoon","family":"Jo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hyun Jee","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wooyong","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,7,22]]},"reference":[{"key":"12183_CR1","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/B978-0-444-62627-1.00024-X","volume":"131","author":"M Bleecker","year":"2015","unstructured":"Bleecker, M. Chap. 12 - Carbon monoxide intoxication. Elsevier Handb. Clin. Neurol. 131, 191\u2013203 (2015).","journal-title":"Elsevier Handb. Clin. Neurol."},{"key":"12183_CR2","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1164\/rccm.201606-1275CI","volume":"195","author":"JJ Rose","year":"2017","unstructured":"Rose, J. J. et al. Carbon monoxide poisoning: pathogenesis, management and future directions of therapy. Am. J. Respir Crit. Care Med. 195, 596\u2013606 (2017).","journal-title":"Am. J. Respir Crit. Care Med."},{"key":"12183_CR3","doi-asserted-by":"publisher","first-page":"585","DOI":"10.1124\/pr.57.4.3","volume":"57","author":"L Wu","year":"2005","unstructured":"Wu, L. & Wang, R. Carbon monoxide: endogenous production, physiological functions, and Pharmacological applications. Pharmacol. Rev. 57, 585\u2013630 (2005).","journal-title":"Pharmacol. Rev."},{"key":"12183_CR4","doi-asserted-by":"publisher","first-page":"275","DOI":"10.1080\/10915810591007256","volume":"24","author":"VA Boumba","year":"2005","unstructured":"Boumba, V. A. & Vougiouklakis, T. Evaluation of the methods used for carboxyhemoglobin analysis in postmortem blood. Int. J. Toxicol. 24, 275\u2013281 (2005).","journal-title":"Int. J. Toxicol."},{"key":"12183_CR5","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1016\/S0379-0738(96)02039-7","volume":"83","author":"S Oritani","year":"1996","unstructured":"Oritani, S., Nagai, K., Zhu, B. & Maeda, H. Estimation of carboxyhemoglobin concentrations in thermo-coagulated blood on a CO-oximeter system: an experimental study. Forensic Sci. Int. 83, 211\u2013218 (1996).","journal-title":"Forensic Sci. Int."},{"key":"12183_CR6","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1520\/JFS11867J","volume":"31","author":"LR Goldbaum","year":"1986","unstructured":"Goldbaum, L. R., Chace, D. H. & Lappas, N. T. Determination of carbon monoxide in blood by gas chromatography using a thermal conductivity detector. J. Forensic Sci. 31, 133\u2013142 (1986).","journal-title":"J. Forensic Sci."},{"key":"12183_CR7","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1093\/jat\/5.6.264","volume":"5","author":"JG Guillot","year":"1981","unstructured":"Guillot, J. G., Weber, J. P. & Savoie, J. Y. Quantitative determination of carbon monoxide in blood by headspace gas chromatography. J. Anal. Toxicol. 5, 264\u2013266 (1981).","journal-title":"J. Anal. Toxicol."},{"key":"12183_CR8","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1520\/JFS13618J","volume":"39","author":"J Van Dam","year":"1994","unstructured":"Van Dam, J. & Daenens, P. Microanalysis of carbon monoxide in blood by headspace capillary gas chromatography. J. Forensic Sci. 39, 479\u2013478 (1994).","journal-title":"J. Forensic Sci."},{"key":"12183_CR9","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1093\/jat\/17.4.193","volume":"17","author":"ZL Cardeal","year":"1993","unstructured":"Cardeal, Z. L. et al. New calibration method for gas chromatographic assay of carbon monoxide in blood. J. Anal. Toxicol. 17, 193\u2013195 (1993).","journal-title":"J. Anal. Toxicol."},{"key":"12183_CR10","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1016\/j.jchromb.2011.11.028","volume":"880","author":"V Varlet","year":"2012","unstructured":"Varlet, V., Lagroy De Croutte, E., Augsburger, M. & Mangin, P. Accuracy profile validation of a new method for carbon monoxide measurement in the human blood using headspace-gas-chromatography-mass spectrometry (HS-GC-MS). J. Chromatogr. B Analyt Technol. Biomed. Life Sci. 880, 125\u2013131 (2012).","journal-title":"J. Chromatogr. B Analyt Technol. Biomed. Life Sci."},{"key":"12183_CR11","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1093\/jat\/16.1.42","volume":"16","author":"SC Wu","year":"1992","unstructured":"Wu, S. C., Levine, B., Goodin, J. C., Caplan, Y. H. & Smith, M. L. Analysis of spleen specimens for carbon monoxide. J. Anal. Toxicol. 16, 42\u201344 (1992).","journal-title":"J. Anal. Toxicol."},{"key":"12183_CR12","doi-asserted-by":"crossref","unstructured":"Toffaletti, J. & Rackley, C. Chap. 1 - Introduction to blood-gas tests and blood-gas physiology,Blood Gases and Critical Care Testing, third ed., Academic Press. 1\u201321 (2022).","DOI":"10.1016\/B978-0-323-89971-0.00002-1"},{"key":"12183_CR13","first-page":"S1","volume":"7","author":"I Alagha","year":"2022","unstructured":"Alagha, I., Doman, G., Aouthmanyzx, S. & Methemoglobinemia J. Ed. Teach. Emerg. Med. 7, S1\u2013S26 (2022).","journal-title":"J. Ed. Teach. Emerg. Med."},{"key":"12183_CR14","doi-asserted-by":"publisher","first-page":"1388","DOI":"10.1093\/clinchem\/25.8.1388","volume":"25","author":"FL Rodkey","year":"1979","unstructured":"Rodkey, F. L., Hill, T. A., Pitts, L. L. & Robertson, R. F. Spectrophotometric measurement of carboxyhemoglobin and methemoglobin in blood. Clin. Chem. 25, 1388\u20131393 (1979).","journal-title":"Clin. Chem."},{"key":"12183_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1093\/jat\/5.1.1","volume":"5","author":"LK Pannell","year":"1981","unstructured":"Pannell, L. K., Thomson, B. M. & Wilkinson, L. F. A modified method for the analysis of carbon monoxide in postmortem blood. J. Anal. Toxicol. 5, 1\u20135 (1981).","journal-title":"J. Anal. Toxicol."},{"key":"12183_CR16","doi-asserted-by":"publisher","first-page":"636","DOI":"10.1111\/1556-4029.14206","volume":"62","author":"M Zanaboni","year":"2020","unstructured":"Zanaboni, M. et al. Comparison of different analytical methods for the determination of carbon monoxide in postmortem blood. J. Forensic Sci. 62, 636\u2013640 (2020).","journal-title":"J. Forensic Sci."},{"key":"12183_CR17","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1093\/jat\/28.1.59","volume":"28","author":"RJ Lewis","year":"2004","unstructured":"Lewis, R. J., Johnson, R. D. & Canfield, D. V. An accurate method for the determination of carbon monoxide in postmortem blood using GC-TCD. J. Anal. Toxicol. 28, 59\u201362 (2004).","journal-title":"J. Anal. Toxicol."},{"key":"12183_CR18","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.1111\/j.1556-4029.2006.00212.x","volume":"51","author":"HJ Vreman","year":"2006","unstructured":"Vreman, H. J. et al. Concentration of carbon monoxide (CO) in postmortem human tissues: effect of environmental CO exposure. J. Forensic Sci. 51, 1182\u20131190 (2006).","journal-title":"J. Forensic Sci."},{"key":"12183_CR19","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.jchromb.2018.05.019","volume":"1090","author":"S Oliverio","year":"2018","unstructured":"Oliverio, S. & Varlet, V. Carbon monoxide analysis method in human blood by airtight gas Syringe - gas Chromatography - Mass spectrometry (AGS-GC-MS): relevance for postmortem poisoning diagnosis. J. Chromatogr. B Analyt Technol. Biomed. Life Sci. 1090, 81\u201389 (2018).","journal-title":"J. Chromatogr. B Analyt Technol. Biomed. Life Sci."},{"key":"12183_CR20","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1093\/clinchem\/14.2.162","volume":"14","author":"H Collison","year":"1968","unstructured":"Collison, H., Rodkey, F. & O\u2019Neal, J. Determination of carbon monoxide in blood by gas chromatography. Clin. Chem. 14, 162\u2013171 (1968).","journal-title":"Clin. Chem."},{"key":"12183_CR21","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1093\/jat\/17.1.11","volume":"17","author":"RA Middleberg","year":"1993","unstructured":"Middleberg, R. A., Easterling, D. E., Zelonis, S. F., Rieders, F. & Rieders, M. F. Estimation of perimortal percent carboxy-heme in nonstandard postmortem specimens using analysis of carbon monoxide by GC\/MS and iron by flame atomic absorption spectrophotometry. J. Anal. Toxicol. 17, 11\u201313 (1993).","journal-title":"J. Anal. Toxicol."},{"key":"12183_CR22","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/S0378-4347(01)00460-1","volume":"766","author":"AM Sundin","year":"2002","unstructured":"Sundin, A. M. & Larsson, J. E. Rapid and sensitive method for the analysis of carbon monoxide in blood using gas chromatography with flame ionisation detection. J. Chromatogr. B Analyt Technol. Biomed. Life Sci. 766, 115\u2013121 (2002).","journal-title":"J. Chromatogr. B Analyt Technol. Biomed. Life Sci."},{"key":"12183_CR23","first-page":"21","volume":"4","author":"SG Walch","year":"2010","unstructured":"Walch, S. G., Lachenmeier, D. W., Sohnius, E., Madea, B. & Musshoff, F. Rapid determination of carboxyhemoglobin in postmortem blood using fully-automated headspace gas chromatography with methaniser and FID. Open. Toxicol. J. 4, 21\u201325 (2010).","journal-title":"Open. Toxicol. J."},{"key":"12183_CR24","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1039\/an9709500439","volume":"95","author":"DJ Blackmore","year":"1970","unstructured":"Blackmore, D. J. The determination of carbon monoxide in blood and tissue. Analyst 95, 439\u2013458 (1970).","journal-title":"Analyst"},{"key":"12183_CR25","doi-asserted-by":"publisher","first-page":"11","DOI":"10.25135\/jcm.58.21.04.2055","volume":"15","author":"AB Shehata","year":"2021","unstructured":"Shehata, A. B., Alyami, N. H., Alowaysi, A. S. & Alaskar, A. R. Preparation and certification of carbon monoxide gas reference material for the quality of CO emission measurements. J. Chem. Metrol. 15, 11\u201324 (2021).","journal-title":"J. Chem. Metrol."},{"key":"12183_CR26","doi-asserted-by":"crossref","unstructured":"Varlet, V., Ryser, E., Augsburger, M. & Palmiere, C. Stability of postmortem methemoglobin: artifactual changes caused by storage conditions. Forensic Sci. Int. 283, 21\u201328 (2018).","DOI":"10.1016\/j.forsciint.2017.12.009"},{"key":"12183_CR27","doi-asserted-by":"publisher","first-page":"13996","DOI":"10.3390\/ijerph192113996","volume":"19","author":"M Padovano","year":"2002","unstructured":"Padovano, M. et al. Sodium nitrite intoxication and death: summarizing evidence to facilitate diagnosis. Int. J. Environ. Res. Public. Health. 19, 13996 (2002).","journal-title":"Int. J. Environ. Res. Public. Health"},{"key":"12183_CR28","doi-asserted-by":"publisher","first-page":"112107","DOI":"10.1016\/j.forsciint.2024.112107","volume":"361","author":"L Miyeon","year":"2024","unstructured":"Miyeon, L. et al. Forensic utility of carboxyhemoglobin levels in postmortem spleen specimens in South Korea. Forensic Sci. Int. 361, 112107 (2024).","journal-title":"Forensic Sci. Int."}],"updated-by":[{"DOI":"10.1038\/s41598-025-19405-9","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T00:00:00Z","timestamp":1757635200000}}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-12183-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-12183-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-12183-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,12]],"date-time":"2025-09-12T09:44:23Z","timestamp":1757670263000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-12183-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,22]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["12183"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-12183-4","relation":{"correction":[{"id-type":"doi","id":"10.1038\/s41598-025-19405-9","asserted-by":"object"}]},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,22]]},"assertion":[{"value":"8 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 September 2025","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1038\/s41598-025-19405-9","URL":"https:\/\/doi.org\/10.1038\/s41598-025-19405-9","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"26564"}}