{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T16:38:24Z","timestamp":1794328704406,"version":"4.9.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,7,26]],"date-time":"2025-07-26T00:00:00Z","timestamp":1753488000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,7,26]],"date-time":"2025-07-26T00:00:00Z","timestamp":1753488000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>To evaluate the clinical efficacy of ZhuZheng robot-assisted versus C-arm fluoroscopy-guided percutaneous pedicle screw fixation (PPSF) in the treatment of thoracolumbar burst fractures. A retrospective analysis was conducted on 86 patients with thoracolumbar burst fractures treated at our institution between March 2022 and August 2023. The cohort included 46 males and 40 females, aged 27 to 69 years. Patients were assigned to either the robot-assisted group (<jats:italic>n<\/jats:italic>\u2009=\u200941) or the conventional C-arm fluoroscopy group (<jats:italic>n<\/jats:italic>\u2009=\u200945) according to intraoperative navigation method. Baseline characteristics, including gender ratio and body mass index (BMI), were comparable between the two groups (<jats:italic>P<\/jats:italic>\u2009&gt;\u20090.05). All patients underwent segmental fixation. Intraoperative parameters such as fluoroscopy frequency, operative time, and estimated blood loss were recorded. The accuracy of screw placement was assessed using postoperative CT at day 3 and graded according to the Gertzbein-Robbins scale. Pain was evaluated using the Visual Analogue Scale (VAS) preoperatively and at 1\u00a0day, 3 days, and 1 month postoperatively. Radiological assessments included Cobb angle and anterior vertebral height ratio at baseline, 3 days, 1 month, and 6 months postoperatively. Statistical analyses were performed using the t-test and Mann-Whitney U test. The robot-assisted group had significantly shorter operative time, reduced intraoperative blood loss, lower radiation dose, and fewer fluoroscopy exposures compared to the conventional group (all <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05). No perioperative complications occurred in either group during follow-up. The screw placement accuracy (grades A\u2009+\u2009B) was significantly higher in the robot-assisted group (98.4%, 242\/246) than in the conventional group (90.4%, 244\/270; <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.05). VAS pain scores at postoperative day 1 and day 3 were significantly lower in the robot-assisted group; no significant difference was observed at 1 month. There were no significant intergroup differences in the postoperative Cobb angle or anterior vertebral height ratio at any time point (<jats:italic>P<\/jats:italic>\u2009&gt;\u20090.05). Robot-assisted orthopedic surgery demonstrates significant advantages in improving screw placement accuracy, reducing intraoperative blood loss, shortening operative time, and minimizing radiation exposure and fluoroscopy frequency, thereby offering improved clinical outcomes in the management of thoracolumbar burst fractures.<\/jats:p>","DOI":"10.1038\/s41598-025-12549-8","type":"journal-article","created":{"date-parts":[[2025,7,26]],"date-time":"2025-07-26T06:09:50Z","timestamp":1753510190000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["A comparative study of robot-assisted navigation versus C-arm fluoroscopy in percutaneous pedicle screw fixation for the treatment of thoracolumbar fractures"],"prefix":"10.1038","volume":"15","author":[{"given":"Lichuan","family":"Liang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chen","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lei","family":"Luo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liehua","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pei","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongjian","family":"Gao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qiang","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,7,26]]},"reference":[{"key":"12549_CR1","doi-asserted-by":"publisher","first-page":"14878","DOI":"10.1038\/s41598-020-71498-6","volume":"10","author":"E Yilmaz","year":"2020","unstructured":"Yilmaz, E. et al. Functional outcome of traumatic spinopelvic instabilities treated with lumbopelvic fixation. Sci. Rep. 10, 14878. https:\/\/doi.org\/10.1038\/s41598-020-71498-6 (2020).","journal-title":"Sci. Rep."},{"key":"12549_CR2","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1007\/s12306-020-00644-0","volume":"105","author":"M Muratore","year":"2021","unstructured":"Muratore, M. et al. Surgical treatment of traumatic thoracolumbar fractures: a retrospective review of 101 cases. Musculoskelet. Surg. 105, 49\u201359. https:\/\/doi.org\/10.1007\/s12306-020-00644-0 (2021).","journal-title":"Musculoskelet. Surg."},{"key":"12549_CR3","doi-asserted-by":"publisher","first-page":"729","DOI":"10.1016\/j.spinee.2013.06.038","volume":"14","author":"LA Westerveld","year":"2014","unstructured":"Westerveld, L. A., van Bemmel, J. C., Dhert, W. J., Oner, F. C. & Verlaan, J. J. Clinical outcome after traumatic spinal fractures in patients with ankylosing spinal disorders compared with control patients. Spine J. 14, 729\u2013740. https:\/\/doi.org\/10.1016\/j.spinee.2013.06.038 (2014).","journal-title":"Spine J."},{"key":"12549_CR4","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1051\/sicotj\/2019039","volume":"5","author":"AS Barakat","year":"2019","unstructured":"Barakat, A. S. et al. A comparative study between the universal spinal System((R)) (USS) and the CD Horizon((R)) legacy (CDH) in the management of thoracolumbar fractures. SICOT J. 5, 42. https:\/\/doi.org\/10.1051\/sicotj\/2019039 (2019).","journal-title":"SICOT J."},{"key":"12549_CR5","doi-asserted-by":"publisher","first-page":"891","DOI":"10.14245\/ns.2142640.320","volume":"18","author":"PJ Lai","year":"2021","unstructured":"Lai, P. J. et al. Percutaneous endoscopic interbody debridement and fusion for pyogenic lumbar spondylodiskitis: surgical technique and the comparison with percutaneous endoscopic drainage and debridement. Neurospine 18, 891\u2013902. https:\/\/doi.org\/10.14245\/ns.2142640.320 (2021).","journal-title":"Neurospine"},{"key":"12549_CR6","doi-asserted-by":"publisher","first-page":"1971","DOI":"10.1111\/os.12808","volume":"12","author":"L Li","year":"2020","unstructured":"Li, L. et al. Salvianic acid A sodium promotes the recovery of motor function after spinal cord injury in rats by reducing microglia inflammation through regulating MIP2\/Vdac1\/Ndufa12 signaling Axis. Orthop. Surg. 12, 1971\u20131979. https:\/\/doi.org\/10.1111\/os.12808 (2020).","journal-title":"Orthop. Surg."},{"key":"12549_CR7","doi-asserted-by":"crossref","unstructured":"Yu, J. et al. Learning curves of robot-assisted pedicle screw fixations based on the cumulative sum test. World J. Clin. Cases (2021).","DOI":"10.12998\/wjcc.v9.i33.10134"},{"key":"12549_CR8","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1016\/j.spinee.2020.09.007","volume":"21","author":"N Fatima","year":"2021","unstructured":"Fatima, N., Massaad, E., Hadzipasic, M., Shankar, G. M. & Shin, J. H. Safety and accuracy of robot-assisted placement of pedicle screws compared to conventional free-hand technique: a systematic review and meta-analysis. Spine J. 21, 181\u2013192. https:\/\/doi.org\/10.1016\/j.spinee.2020.09.007 (2021).","journal-title":"Spine J."},{"key":"12549_CR9","unstructured":"Chuchulo, A. & Ali, A. Is robotic-assisted surgery better? AMA J. Ethics (2023)."},{"key":"12549_CR10","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1007\/s11701-011-0246-y","volume":"5","author":"MD Gastrich","year":"2011","unstructured":"Gastrich, M. D., Barone, J., Bachmann, G., Anderson, M. & Balica, A. Robotic surgery: review of the latest advances, risks, and outcomes. J. Robot Surg. 5, 79\u201397. https:\/\/doi.org\/10.1007\/s11701-011-0246-y (2011).","journal-title":"J. Robot Surg."},{"key":"12549_CR11","doi-asserted-by":"publisher","first-page":"1120831","DOI":"10.3389\/fped.2023.1120831","volume":"11","author":"H Mei","year":"2023","unstructured":"Mei, H. & Tang, S. Robotic-assisted surgery in the pediatric surgeons\u2019 world: current situation and future prospectives. Front. Pediatr. 11, 1120831. https:\/\/doi.org\/10.3389\/fped.2023.1120831 (2023).","journal-title":"Front. Pediatr."},{"key":"12549_CR12","doi-asserted-by":"crossref","unstructured":"MagerP, F., Gertzbein, M. A. S. D. & Harms, J., and S. Nazarian A comprehensive classification of thoracic and lumbar injuries. Eur Spine J (1994).","DOI":"10.1007\/BF02221591"},{"key":"12549_CR13","doi-asserted-by":"publisher","first-page":"e2262","DOI":"10.1002\/rcs.2262","volume":"17","author":"J Zhang","year":"2021","unstructured":"Zhang, J., Li, W., Hu, L., Yu, Z. & Wang, T. A robotic system for spine surgery positioning and pedicle screw placement. Int. J. Med. Robot. 17, e2262. https:\/\/doi.org\/10.1002\/rcs.2262 (2021).","journal-title":"Int. J. Med. Robot"},{"key":"12549_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/rcs.2171","volume":"16","author":"Y Luo","year":"2020","unstructured":"Luo, Y. et al. A novel fluoroscopy-based robot system for pedicle screw fixation surgery. Int. J. Med. Robot. 16, 1\u20138. https:\/\/doi.org\/10.1002\/rcs.2171 (2020).","journal-title":"Int. J. Med. Robot"},{"key":"12549_CR15","doi-asserted-by":"publisher","first-page":"1373","DOI":"10.1016\/j.spinee.2017.06.022","volume":"17","author":"FY Tsuang","year":"2017","unstructured":"Tsuang, F. Y. et al. Percutaneous pedicle screw placement under single dimensional fluoroscopy with a designed pedicle finder-a technical note and case series. Spine J. 17, 1373\u20131380. https:\/\/doi.org\/10.1016\/j.spinee.2017.06.022 (2017).","journal-title":"Spine J."},{"key":"12549_CR16","doi-asserted-by":"publisher","first-page":"1918","DOI":"10.1007\/s00586-018-5587-z","volume":"27","author":"T Tajsic","year":"2018","unstructured":"Tajsic, T., Patel, K., Farmer, R., Mannion, R. J. & Trivedi, R. A. Spinal navigation for minimally invasive thoracic and lumbosacral spine fixation: implications for radiation exposure, operative time, and accuracy of pedicle screw placement. Eur. Spine J. 27, 1918\u20131924. https:\/\/doi.org\/10.1007\/s00586-018-5587-z (2018).","journal-title":"Eur. Spine J."},{"key":"12549_CR17","doi-asserted-by":"publisher","first-page":"422","DOI":"10.3171\/2014.11.SPINE14181","volume":"22","author":"SM Spitz","year":"2015","unstructured":"Spitz, S. M., Sandhu, F. A. & Voyadzis, J. M. Percutaneous K-wireless pedicle screw fixation technique: an evaluation of the initial experience of 100 screws with assessment of accuracy, radiation exposure, and procedure time. J. Neurosurg. Spine. 22, 422\u2013431. https:\/\/doi.org\/10.3171\/2014.11.SPINE14181 (2015).","journal-title":"J. Neurosurg. Spine"},{"key":"12549_CR18","doi-asserted-by":"publisher","first-page":"e1057","DOI":"10.1016\/j.wneu.2019.01.243","volume":"125","author":"S Feng","year":"2019","unstructured":"Feng, S., Tian, W., Sun, Y., Liu, Y. & Wei, Y. Effect of Robot-Assisted surgery on lumbar pedicle screw internal fixation in patients with osteoporosis. World Neurosurg. 125, e1057\u2013e1062. https:\/\/doi.org\/10.1016\/j.wneu.2019.01.243 (2019).","journal-title":"World Neurosurg."},{"key":"12549_CR19","doi-asserted-by":"publisher","first-page":"920","DOI":"10.31616\/asj.2019.0033","volume":"13","author":"JKT Kam","year":"2019","unstructured":"Kam, J. K. T. et al. Learning curve for Robot-Assisted percutaneous pedicle screw placement in thoracolumbar surgery. Asian Spine J. 13, 920\u2013927. https:\/\/doi.org\/10.31616\/asj.2019.0033 (2019).","journal-title":"Asian Spine J."},{"key":"12549_CR20","doi-asserted-by":"publisher","first-page":"e417","DOI":"10.1016\/j.wneu.2019.06.107","volume":"130","author":"MI Siddiqui","year":"2019","unstructured":"Siddiqui, M. I., Wallace, D. J., Salazar, L. M. & Vardiman, A. B. Robot-Assisted pedicle screw placement: learning curve experience. World Neurosurg. 130, e417\u2013e422. https:\/\/doi.org\/10.1016\/j.wneu.2019.06.107 (2019).","journal-title":"World Neurosurg."},{"key":"12549_CR21","doi-asserted-by":"publisher","first-page":"E10","DOI":"10.3171\/2021.10.FOCUS21509","volume":"52","author":"A Naik","year":"2022","unstructured":"Naik, A. et al. Evaluating robotic pedicle screw placement against conventional modalities: a systematic review and network meta-analysis. Neurosurg. Focus. 52, E10. https:\/\/doi.org\/10.3171\/2021.10.FOCUS21509 (2022).","journal-title":"Neurosurg. Focus"},{"key":"12549_CR22","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1016\/j.wneu.2016.11.133","volume":"99","author":"B Ozdemir","year":"2017","unstructured":"Ozdemir, B. et al. Restoration of anterior vertebral height by Short-Segment pedicle screw fixation with screwing of fractured vertebra for the treatment of unstable thoracolumbar fractures. World Neurosurg. 99, 409\u2013417. https:\/\/doi.org\/10.1016\/j.wneu.2016.11.133 (2017).","journal-title":"World Neurosurg."},{"key":"12549_CR23","doi-asserted-by":"publisher","first-page":"669","DOI":"10.21037\/atm-21-881","volume":"9","author":"W Yao","year":"2021","unstructured":"Yao, W. et al. A comparison of monoaxial pedicle screw versus polyaxial pedicle screw in short-segment posterior fixation for the treatment of thoracolumbar fractured vertebra. Ann. Transl Med. 9, 669. https:\/\/doi.org\/10.21037\/atm-21-881 (2021).","journal-title":"Ann. Transl Med."},{"key":"12549_CR24","doi-asserted-by":"publisher","first-page":"1060","DOI":"10.1016\/j.injury.2020.10.014","volume":"52","author":"S Ding","year":"2021","unstructured":"Ding, S., Lu, X., Liu, Z. & Wang, Y. Reduce the fractured central endplate in thoracolumbar fractures using percutaneous pedicle screws and instrumentational maneuvers: technical strategy and radiological outcomes. Injury 52, 1060\u20131064. https:\/\/doi.org\/10.1016\/j.injury.2020.10.014 (2021).","journal-title":"Injury"},{"key":"12549_CR25","doi-asserted-by":"publisher","first-page":"e423","DOI":"10.1016\/j.wneu.2024.09.116","volume":"192","author":"Y Wang","year":"2024","unstructured":"Wang, Y., Li, G., Hu, X., Xu, N. & Ma, W. Influence of screw length and cement position within the injured vertebra on fixation strength in Short-Segment fixation of osteoporotic thoracolumbar burst fractures. World Neurosurg. 192, e423\u2013e434. https:\/\/doi.org\/10.1016\/j.wneu.2024.09.116 (2024).","journal-title":"World Neurosurg."},{"key":"12549_CR26","doi-asserted-by":"publisher","first-page":"1398","DOI":"10.1080\/10255842.2023.2243360","volume":"27","author":"C Xu","year":"2024","unstructured":"Xu, C., Bai, X., Ruan, D. & Zhang, C. Comparative finite element analysis of posterior short segment fixation constructs with or without intermediate screws in the fractured vertebrae for the treatment of type a thoracolumbar fracture. Comput. Methods Biomech. Biomed. Engin. 27, 1398\u20131409. https:\/\/doi.org\/10.1080\/10255842.2023.2243360 (2024).","journal-title":"Comput. Methods Biomech. Biomed. Engin"},{"key":"12549_CR27","unstructured":"Guduru, A. V., Sujir, I. K. P., Jain, M. K. & Sodavarapu, P. Effect of pedicle screw placement into the fractured vertebra in management of unstable thoracolumbar and lumbar fractures. Int. J. Burns Trauma (2022)."},{"key":"12549_CR28","doi-asserted-by":"publisher","first-page":"90","DOI":"10.13004\/kjnt.2023.19.e9","volume":"19","author":"M Rezvani","year":"2023","unstructured":"Rezvani, M., Asadi, J., Sourani, A., Foroughi, M. & Tehrani, D. S. In-Fracture pedicular screw placement during ligamentotaxis following traumatic spine injuries, a randomized clinical trial on outcomes. Korean J. Neurotrauma. 19, 90\u2013102. https:\/\/doi.org\/10.13004\/kjnt.2023.19.e9 (2023).","journal-title":"Korean J. Neurotrauma"},{"key":"12549_CR29","doi-asserted-by":"publisher","first-page":"712","DOI":"10.14444\/8660","volume":"18","author":"M Bhimreddy","year":"2024","unstructured":"Bhimreddy, M. et al. Accuracy of pedicle screw placement using the ExcelsiusGPS robotic navigation platform: an analysis of 728 screws. Int. J. Spine Surg. 18, 712\u2013720. https:\/\/doi.org\/10.14444\/8660 (2024).","journal-title":"Int. J. Spine Surg."},{"key":"12549_CR30","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1007\/s11701-024-01874-1","volume":"18","author":"Z Yang","year":"2024","unstructured":"Yang, Z., Sun, Y., Deng, C., Dong, X. & Hao, L. Comparative efficacy of robotic-assisted and freehand techniques for pedicle screw placement in spinal disorders: a meta-analysis and systematic review. J. Robot Surg. 18, 121. https:\/\/doi.org\/10.1007\/s11701-024-01874-1 (2024).","journal-title":"J. Robot Surg."},{"key":"12549_CR31","doi-asserted-by":"publisher","first-page":"841","DOI":"10.3171\/2021.8.SPINE21330","volume":"36","author":"JI Liounakos","year":"2022","unstructured":"Liounakos, J. I. et al. Ninety-day complication, revision, and readmission rates for current-generation robot-assisted thoracolumbar spinal fusion surgery: results of a multicenter case series. J. Neurosurg. Spine. 36, 841\u2013848. https:\/\/doi.org\/10.3171\/2021.8.SPINE21330 (2022).","journal-title":"J. Neurosurg. Spine"},{"key":"12549_CR32","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1007\/s00586-011-2011-3","volume":"21","author":"ID Gelalis","year":"2012","unstructured":"Gelalis, I. D. et al. Accuracy of pedicle screw placement: a systematic review of prospective in vivo studies comparing free hand, fluoroscopy guidance and navigation techniques. Eur. Spine J. 21, 247\u2013255. https:\/\/doi.org\/10.1007\/s00586-011-2011-3 (2012).","journal-title":"Eur. Spine J."},{"key":"12549_CR33","doi-asserted-by":"publisher","first-page":"e0020","DOI":"10.2106\/JBJS.ST.19.00020","volume":"10","author":"IH Lieberman","year":"2020","unstructured":"Lieberman, I. H., Kisinde, S. & Hesselbacher, S. Robotic-Assisted pedicle screw placement during spine surgery. JBJS Essent. Surg. Tech. 10, e0020. https:\/\/doi.org\/10.2106\/JBJS.ST.19.00020 (2020).","journal-title":"JBJS Essent. Surg. Tech."},{"key":"12549_CR34","doi-asserted-by":"publisher","first-page":"101421","DOI":"10.1016\/j.eclinm.2022.101421","volume":"48","author":"FL Wei","year":"2022","unstructured":"Wei, F. L. et al. Association of robot-assisted techniques with the accuracy rates of pedicle screw placement: A network pooling analysis. EClinicalMedicine 48, 101421. https:\/\/doi.org\/10.1016\/j.eclinm.2022.101421 (2022).","journal-title":"EClinicalMedicine"},{"key":"12549_CR35","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1016\/j.spinee.2022.10.006","volume":"23","author":"AV Matur","year":"2023","unstructured":"Matur, A. V. et al. Robotic and navigated pedicle screws are safer and more accurate than fluoroscopic freehand screws: a systematic review and meta-analysis. Spine J. 23, 197\u2013208. https:\/\/doi.org\/10.1016\/j.spinee.2022.10.006 (2023).","journal-title":"Spine J."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-12549-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-12549-8","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-12549-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T18:04:55Z","timestamp":1753898695000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-12549-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,7,26]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["12549"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-12549-8","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,7,26]]},"assertion":[{"value":"8 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 July 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"This study adheres to all relevant ethical guidelines and regulatory standards. The research protocols were reviewed and approved by the Ethics Committee of the Third Affiliated Hospital of Chongqing Medical University. Prior to their participation, informed consent was obtained from all participants involved in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}],"article-number":"27214"}}