{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T06:49:51Z","timestamp":1787726991637,"version":"build-2784847793"},"reference-count":71,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T00:00:00Z","timestamp":1754092800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T00:00:00Z","timestamp":1754092800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100009153","name":"University of Portsmouth","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100009153","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Carl Zeiss Microscopy GmbH"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Transmission of strain across the tendon-bone interface otherwise known as the enthesis, is crucial to the movement of the skeleton. Imaging the inner structure and understanding the way that strain is transmitted across this interface is crucial to understanding the way it responds to load, how it becomes injured through trauma and how intervention and materials can be used to repair the enthesis after injury. Micro-CT imaging and digital volume correlation (DVC) have been widely used for musculoskeletal biomechanics analysis. However, there are limitations for soft tissue visualization. Contrast agents (CA) are used to address this, but understanding their potential effects is essential to ensure accurate and reliable characterization of musculoskeletal tissues biomechanics. In this research, four different contrast-enhanced staining solutions (CESS) including Iodine (I<jats:sub>2<\/jats:sub>) in Dulbecco\u2019s modified eagle medium (DMEM), Phosphotungstic acid (PTA) in deionized water, PTA in ethanol, and Mercury II Chloride (HgCl<jats:sub>2<\/jats:sub>) in deionized water were used to visualize the tendon-to-bone interface using a combination of high resolution in-situ micro-computed tomography (micro-CT) imaging. The imaging was combined with DVC, nanoindentation, and quantitative 3D structural analysis to evaluate the effects of the CESS on the mechanical properties of the enthesis. The findings revealed significant alterations in mechanical behaviour and structural features of soft-to-hard tissue interfaces treated by CESS. The findings suggest that I\u2082 in DMEM provides a better balance between visualization and mechanical analysis. However, none of the CESSs completely preserved both structural and mechanical integrity.<\/jats:p>","DOI":"10.1038\/s41598-025-12729-6","type":"journal-article","created":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T17:24:40Z","timestamp":1754155480000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Evaluating the impact of contrast agents on micro and nano mechanics of soft-to-hard tissue interface"],"prefix":"10.1038","volume":"15","author":[{"given":"Atousa","family":"Moayedi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Katerina","family":"Karali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Markus","family":"Boese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jurgita","family":"Zekonyte","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jovana","family":"Radulovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gordon","family":"Blunn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,8,2]]},"reference":[{"key":"12729_CR1","doi-asserted-by":"publisher","first-page":"520","DOI":"10.1111\/j.1600-0838.2009.00906.x","volume":"19","author":"M Benjamin","year":"2009","unstructured":"Benjamin, M. & McGonagle, D. Entheses: tendon and ligament attachment sites. Scand. J. Med. Sci. Sports. 19, 520\u2013527 (2009).","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"12729_CR2","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.mechmat.2011.08.005","volume":"44","author":"YX Liu","year":"2012","unstructured":"Liu, Y. X., Thomopoulos, S., Birman, V., Li, J. S. & Genin, G. M. Bi-material attachment through a compliant interfacial system at the tendon-to-bone insertion site. Mech. Mater. 44, 83\u201392 (2012).","journal-title":"Mech. Mater."},{"key":"12729_CR3","doi-asserted-by":"publisher","first-page":"16534","DOI":"10.1038\/s41598-021-95917-4","volume":"11","author":"A Tits","year":"2021","unstructured":"Tits, A. et al. Local anisotropy in mineralized fibrocartilage and subchondral bone beneath the tendon-bone interface. Sci. Rep. 11, 16534 (2021).","journal-title":"Sci. Rep."},{"key":"12729_CR4","doi-asserted-by":"publisher","first-page":"471","DOI":"10.1111\/j.1469-7580.2006.00540.x","volume":"208","author":"M Benjamin","year":"2006","unstructured":"Benjamin, M. et al. Where tendons and ligaments Meet bone: attachment sites (\u2018entheses\u2019) in relation to exercise and\/or mechanical load. J. Anat. 208, 471\u2013490 (2006).","journal-title":"J. Anat."},{"key":"12729_CR5","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1111\/j.1600-0838.2007.00689.x","volume":"17","author":"HM Shaw","year":"2007","unstructured":"Shaw, H. M. & Benjamin, M. Structure\u2013function relationships of entheses in relation to mechanical load and exercise. Scand. J. Med. Sci. Sports. 17, 303\u2013315 (2007).","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"12729_CR6","first-page":"187","volume":"87","author":"P Sharma","year":"2005","unstructured":"Sharma, P. & Maffulli, N. Tendon injury and tendinopathy: healing and repair. JBJS 87, 187\u2013202 (2005).","journal-title":"JBJS"},{"key":"12729_CR7","doi-asserted-by":"publisher","first-page":"664","DOI":"10.1038\/nmat4863","volume":"16","author":"L Rossetti","year":"2017","unstructured":"Rossetti, L. et al. The microstructure and micromechanics of the tendon\u2013bone insertion. Nat. Mater. 16, 664\u2013670 (2017).","journal-title":"Nat. Mater."},{"key":"12729_CR8","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1016\/j.bpj.2014.09.049","volume":"108","author":"Y Hu","year":"2015","unstructured":"Hu, Y. et al. Stochastic interdigitation as a toughening mechanism at the interface between tendon and bone. Biophys. J. 108, 431\u2013437 (2015).","journal-title":"Biophys. J."},{"key":"12729_CR9","doi-asserted-by":"publisher","unstructured":"Calejo, I., Costa-Almeida, R., Reis, R. L. & Gomes, M. E. Enthesis tissue engineering: Biological requirements meet at the interface. Tissue Eng. Part B: Rev.  25 https:\/\/doi.org\/10.1089\/ten.teb.2018.0383 (2019).","DOI":"10.1089\/ten.teb.2018.0383"},{"key":"12729_CR10","doi-asserted-by":"publisher","first-page":"9253","DOI":"10.1038\/s41467-024-53542-5","volume":"15","author":"J Fang","year":"2024","unstructured":"Fang, J. et al. Decoding the mechanical characteristics of the human anterior cruciate ligament entheses through graduated mineralization interfaces. Nat. Commun. 15, 9253 (2024).","journal-title":"Nat. Commun."},{"key":"12729_CR11","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1016\/j.actbio.2023.04.018","volume":"166","author":"A Tits","year":"2023","unstructured":"Tits, A. et al. Structural and functional heterogeneity of mineralized fibrocartilage at the Achilles tendon-bone insertion. Acta Biomater. 166, 409\u2013418 (2023).","journal-title":"Acta Biomater."},{"key":"12729_CR12","doi-asserted-by":"crossref","unstructured":"Golman, M. et al. Toughening mechanisms for the attachment of architectured materials: the mechanics of the tendon enthesis. Sci. Adv. 7, (2021).","DOI":"10.1126\/sciadv.abi5584"},{"key":"12729_CR13","doi-asserted-by":"publisher","first-page":"1872","DOI":"10.1002\/jor.25210","volume":"40","author":"T Saito","year":"2022","unstructured":"Saito, T. et al. The effect of mechanical stress on enthesis homeostasis in a rat Achilles enthesis organ culture model. J. Orthop. Res.\u00ae 40, 1872\u20131882 (2022).","journal-title":"J. Orthop. Research\u00ae"},{"key":"12729_CR14","doi-asserted-by":"publisher","first-page":"1842","DOI":"10.1016\/j.jbiomech.2005.05.021","volume":"39","author":"S Thomopoulos","year":"2006","unstructured":"Thomopoulos, S., Marquez, J. P., Weinberger, B., Birman, V. & Genin, G. M. Collagen fiber orientation at the tendon to bone insertion and its influence on stress concentrations. J. Biomech. 39, 1842\u20131851 (2006).","journal-title":"J. Biomech."},{"key":"12729_CR15","doi-asserted-by":"crossref","unstructured":"Konofagou, E. E., Spalazzi, J. P. & Lu, H. H. Elastographic imaging of the strain distribution at the anterior cruciate ligament and ACL-bone insertions. In IEEE Engineering in Medicine and Biology 27th Annual Conference 972\u2013975  (IEEE, 2006).","DOI":"10.1109\/IEMBS.2005.1616579"},{"key":"12729_CR16","first-page":"1","volume":"23","author":"D Semwogerere","year":"2005","unstructured":"Semwogerere, D. & Weeks, E. R. Confocal microscopy. Encyclopedia Biomaterials Biomedical Eng. 23, 1\u201310 (2005).","journal-title":"Encyclopedia Biomaterials Biomedical Eng."},{"key":"12729_CR17","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.abb.2015.02.009","volume":"581","author":"A Rigort","year":"2015","unstructured":"Rigort, A. & Plitzko, J. M. Cryo-focused-ion-beam applications in structural biology. Arch. Biochem. Biophys. 581, 122\u2013130 (2015).","journal-title":"Arch. Biochem. Biophys."},{"key":"12729_CR18","doi-asserted-by":"publisher","first-page":"803","DOI":"10.1016\/j.cirp.2010.05.009","volume":"59","author":"DA Lucca","year":"2010","unstructured":"Lucca, D. A., Herrmann, K. & Klopfstein, M. J. Nanoindentation: measuring methods and applications. CIRP Ann. 59, 803\u2013819 (2010).","journal-title":"CIRP Ann."},{"key":"12729_CR19","doi-asserted-by":"publisher","first-page":"949","DOI":"10.1103\/RevModPhys.75.949","volume":"75","author":"F Giessibl","year":"2003","unstructured":"Giessibl, F. J. Advances in atomic force microscopy. Rev. Mod. Phys. 75, 949 (2003).","journal-title":"Rev. Mod. Phys."},{"key":"12729_CR20","doi-asserted-by":"publisher","first-page":"470","DOI":"10.1002\/mrm.26659","volume":"79","author":"J Braun","year":"2018","unstructured":"Braun, J. et al. A compact 0.5 T MR elastography device and its application for studying viscoelasticity changes in biological tissues during progressive formalin fixation. Magn. Reson. Med. 79, 470\u2013478 (2018).","journal-title":"Magn. Reson. Med."},{"key":"12729_CR21","doi-asserted-by":"crossref","unstructured":"Verma, N. & Pullela, M. Material models for finite element analysis of soft tissues. In Microbiology-2.0 Update for a Sustainable Future 427\u2013450 (Springer, (2024).","DOI":"10.1007\/978-981-99-9617-9_19"},{"key":"12729_CR22","doi-asserted-by":"publisher","first-page":"2051","DOI":"10.1007\/s11517-021-02432-9","volume":"59","author":"I Bojairami","year":"2021","unstructured":"Bojairami, I., El, Hamedzadeh, A. & Driscoll, M. Feasibility of extracting tissue material properties via cohesive elements: a finite element approach to probe insertion procedures in non-invasive spine surgeries. Med. Biol. Eng. Comput. 59, 2051\u20132061 (2021).","journal-title":"Med. Biol. Eng. Comput."},{"key":"12729_CR23","doi-asserted-by":"publisher","first-page":"6207","DOI":"10.1038\/s41467-022-34048-4","volume":"13","author":"A Maes","year":"2022","unstructured":"Maes, A. et al. Cryogenic contrast-enhanced MicroCT enables nondestructive 3D quantitative histopathology of soft biological tissues. Nat. Commun. 13, 6207 (2022).","journal-title":"Nat. Commun."},{"key":"12729_CR24","unstructured":"Baruchel, J., Buffiere, J. Y. & Maire, E. X-ray tomography in material science. (2000)."},{"key":"12729_CR25","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1002\/1527-2648(200108)3:8<539::AID-ADEM539>3.0.CO;2-6","volume":"3","author":"E Maire","year":"2001","unstructured":"Maire, E. et al. On the application of X-ray microtomography in the field of materials science. Adv. Eng. Mater. 3, 539\u2013546 (2001).","journal-title":"Adv. Eng. Mater."},{"key":"12729_CR26","doi-asserted-by":"publisher","first-page":"343","DOI":"10.1038\/s41551-019-0477-1","volume":"4","author":"K Madi","year":"2020","unstructured":"Madi, K. et al. In situ characterization of nanoscale strains in loaded whole joints via synchrotron X-ray tomography. Nat. Biomed. Eng. 4, 343\u2013354 (2020).","journal-title":"Nat. Biomed. Eng."},{"key":"12729_CR27","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1016\/j.bone.2006.01.147","volume":"39","author":"PJ Thurner","year":"2006","unstructured":"Thurner, P. J. et al. Time-lapsed investigation of three-dimensional failure and damage accumulation in trabecular bone using synchrotron light. Bone 39, 289\u2013299 (2006).","journal-title":"Bone"},{"key":"12729_CR28","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1111\/jmi.12701","volume":"272","author":"CM Disney","year":"2018","unstructured":"Disney, C. M., Lee, P. D., Hoyland, J. A., Sherratt, M. J. & Bay, B. K. A review of techniques for visualising soft tissue microstructure deformation and quantifying strain ex vivo. J. Microsc. 272, 165\u2013179 (2018).","journal-title":"J. Microsc"},{"key":"12729_CR29","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1007\/BF02323555","volume":"39","author":"BK Bay","year":"1999","unstructured":"Bay, B. K., Smith, T. S., Fyhrie, D. P. & Saad, M. Digital volume correlation: three-dimensional strain mapping using X-ray tomography. Exp. Mech. 39, 217\u2013226 (1999).","journal-title":"Exp. Mech."},{"key":"12729_CR30","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1007\/s11340-010-9407-6","volume":"51","author":"H Leclerc","year":"2011","unstructured":"Leclerc, H., P\u00e9ri\u00e9, J. N., Roux, S. & Hild, F. Voxel-scale digital volume correlation. Exp. Mech. 51, 479\u2013490 (2011).","journal-title":"Exp. Mech."},{"key":"12729_CR31","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1007\/s00276-023-03295-5","volume":"46","author":"A Parrilli","year":"2024","unstructured":"Parrilli, A. et al. 3D visualization of the human anterior cruciate ligament combining micro-CT and histological analysis. Surg. Radiol. Anat. 46, 249\u2013258 (2024).","journal-title":"Surg. Radiol. Anat."},{"key":"12729_CR32","doi-asserted-by":"publisher","first-page":"6635","DOI":"10.1016\/j.biomaterials.2010.05.024","volume":"31","author":"SP Ho","year":"2010","unstructured":"Ho, S. P. et al. The Biomechanical characteristics of the bone-periodontal ligament-cementum complex. Biomaterials 31, 6635\u20136646 (2010).","journal-title":"Biomaterials"},{"key":"12729_CR33","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/j.jbiomech.2010.08.027","volume":"44","author":"NS Jeffery","year":"2011","unstructured":"Jeffery, N. S., Stephenson, R. S., Gallagher, J. A., Jarvis, J. C. & Cox, P. G. Micro-computed tomography with iodine staining resolves the arrangement of muscle fibres. J. Biomech. 44, 189\u2013192 (2011).","journal-title":"J. Biomech."},{"key":"12729_CR34","doi-asserted-by":"publisher","first-page":"425","DOI":"10.1016\/j.crvi.2015.04.009","volume":"338","author":"M Nierenberger","year":"2015","unstructured":"Nierenberger, M., R\u00e9mond, Y., Ahzi, S. & Choquet, P. Assessing the three-dimensional collagen network in soft tissues using contrast agents and high resolution micro-CT: application to Porcine Iliac veins. C R Biol. 338, 425\u2013433 (2015).","journal-title":"C R Biol."},{"key":"12729_CR35","doi-asserted-by":"publisher","unstructured":"Clark, J. N. et al. Exploratory full-field mechanical analysis across the osteochondral tissue\u2014Biomaterial interface in an ovine model. Materials 13 https:\/\/doi.org\/10.3390\/ma13183911 (2020).","DOI":"10.3390\/ma13183911"},{"key":"12729_CR36","doi-asserted-by":"publisher","first-page":"2100085","DOI":"10.1002\/adem.202100085","volume":"23","author":"J Sartori","year":"2021","unstructured":"Sartori, J., K\u00f6hring, S., Bruns, S., Moosmann, J. & Hammel, J. U. Gaining insight into the deformation of Achilles tendon entheses in mice. Adv. Eng. Mater. 23, 2100085 (2021).","journal-title":"Adv. Eng. Mater."},{"key":"12729_CR37","doi-asserted-by":"publisher","first-page":"104806","DOI":"10.1016\/j.jmbbm.2021.104806","volume":"124","author":"JN Clark","year":"2021","unstructured":"Clark, J. N. et al. High resolution three-dimensional strain measurements in human articular cartilage. J. Mech. Behav. Biomed. Mater. 124, 104806 (2021).","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"12729_CR38","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1002\/jor.1100130214","volume":"13","author":"BK Bay","year":"1995","unstructured":"Bay, B. K. Texture correlation: a method for the measurement of detailed strain distributions within trabecular bone. J. Orthop. Res. 13, 258\u2013267 (1995).","journal-title":"J. Orthop. Res."},{"key":"12729_CR39","doi-asserted-by":"publisher","first-page":"13234","DOI":"10.1021\/ja9053306","volume":"131","author":"NS Joshi","year":"2009","unstructured":"Joshi, N. S., Bansal, P. N., Stewart, R. C., Snyder, B. D. & Grinstaff, M. W. Effect of contrast agent charge on visualization of articular cartilage using computed tomography: exploiting electrostatic interactions for improved sensitivity. J. Am. Chem. Soc. 131, 13234\u201313235 (2009).","journal-title":"J. Am. Chem. Soc."},{"key":"12729_CR40","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1002\/ar.23716","volume":"301","author":"E Dickinson","year":"2018","unstructured":"Dickinson, E., Stark, H. & Kupczik, K. N on-D estructive D etermination of M Uscle A rchitectural V Ariables T Hrough the U se of D ice CT. Anat. Rec. 301, 363\u2013377 (2018).","journal-title":"Anat. Rec"},{"key":"12729_CR41","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/j.jtbi.2015.06.034","volume":"382","author":"K Kupczik","year":"2015","unstructured":"Kupczik, K. et al. Reconstruction of muscle fascicle architecture from iodine-enhanced MicroCT images: A combined texture mapping and streamline approach. J. Theor. Biol. 382, 34\u201343 (2015).","journal-title":"J. Theor. Biol."},{"key":"12729_CR42","doi-asserted-by":"publisher","first-page":"e105552","DOI":"10.1371\/journal.pone.0105552","volume":"9","author":"TD Butters","year":"2014","unstructured":"Butters, T. D. et al. Optimal iodine staining of cardiac tissue for X-ray computed tomography. PLoS One. 9, e105552 (2014).","journal-title":"PLoS One"},{"key":"12729_CR43","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1002\/cmmi.238","volume":"3","author":"M Almajdub","year":"2008","unstructured":"Almajdub, M., Magnier, L., Juillard, L. & Janier, M. Kidney volume quantification using contrast-enhanced in vivo X\u2010ray micro\u2010CT in mice. Contrast Media Mol. Imaging. 3, 120\u2013126 (2008).","journal-title":"Contrast Media Mol. Imaging"},{"key":"12729_CR44","doi-asserted-by":"crossref","unstructured":"Sartori, J., K\u00f6hring, S., Witte, H., Fischer, M. S. & L\u00f6ffler, M. Three-dimensional imaging of the fibrous microstructure of Achilles tendon entheses in Mus musculus. J. Anat. 233, (2018).","DOI":"10.1111\/joa.12837"},{"key":"12729_CR45","doi-asserted-by":"publisher","first-page":"238","DOI":"10.32098\/mltj.02.2014.26","volume":"4","author":"T Shearer","year":"2014","unstructured":"Shearer, T. et al. X-ray computed tomography of the anterior cruciate ligament and patellar tendon. Muscles Ligaments Tendons J. 4, 238 (2014).","journal-title":"Muscles Ligaments Tendons J."},{"key":"12729_CR46","doi-asserted-by":"publisher","first-page":"e0153552","DOI":"10.1371\/journal.pone.0153552","volume":"11","author":"R Balint","year":"2016","unstructured":"Balint, R., Lowe, T. & Shearer, T. Optimal contrast agent staining of ligaments and tendons for X-ray computed tomography. PLoS One. 11, e0153552 (2016).","journal-title":"PLoS One"},{"key":"12729_CR47","doi-asserted-by":"publisher","first-page":"100038","DOI":"10.1016\/j.tmater.2024.100038","volume":"6","author":"M P\u00e9tr\u00e9","year":"2024","unstructured":"P\u00e9tr\u00e9, M. et al. Screening staining agents for contrast-enhanced MicroCT of vascular tissues: assessing the effect on microstructural and mechanical properties. Tomography Mater. Struct. 6, 100038 (2024).","journal-title":"Tomography Mater. Struct."},{"key":"12729_CR48","doi-asserted-by":"publisher","first-page":"64033","DOI":"10.1117\/1.2147155","volume":"10","author":"PL Hsiung","year":"2006","unstructured":"Hsiung, P. L., Nambiar, P. R. & Fujimoto, J. G. Effect of tissue preservation on imaging using ultrahigh resolution optical coherence tomography. J. Biomed. Opt. 10, 64033 (2006).","journal-title":"J. Biomed. Opt."},{"key":"12729_CR49","doi-asserted-by":"publisher","first-page":"19781","DOI":"10.1038\/s41598-021-99202-2","volume":"11","author":"Y Dawood","year":"2021","unstructured":"Dawood, Y. et al. Reducing soft-tissue shrinkage artefacts caused by staining with lugol\u2019s solution. Sci. Rep. 11, 19781 (2021).","journal-title":"Sci. Rep."},{"key":"12729_CR50","doi-asserted-by":"crossref","unstructured":"Kaiho, T. Iodine Chemistry and Applications (Wiley, 2014).","DOI":"10.1002\/9781118909911"},{"key":"12729_CR51","doi-asserted-by":"crossref","unstructured":"Orhan, K. Micro-Computed Tomography (Micro-CT) in Medicine and Engineering. (2020).","DOI":"10.1007\/978-3-030-16641-0"},{"key":"12729_CR52","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1016\/0022-2836(79)90251-1","volume":"133","author":"T Nemetschek","year":"1979","unstructured":"Nemetschek, T., Riedl, H. & Jonak, R. Topochemistry of the binding of phosphotungstic acid to collagen. J. Mol. Biol. 133, 67\u201383 (1979).","journal-title":"J. Mol. Biol."},{"key":"12729_CR53","doi-asserted-by":"publisher","first-page":"1057394","DOI":"10.3389\/fphys.2023.1057394","volume":"14","author":"A Hanly","year":"2023","unstructured":"Hanly, A. et al. Phosphotungstic acid (PTA) preferentially binds to collagen-rich regions of Porcine carotid arteries and human atherosclerotic plaques observed using contrast enhanced micro-computed tomography (CE-\u00b5CT). Front. Physiol. 14, 1057394 (2023).","journal-title":"Front. Physiol."},{"key":"12729_CR54","first-page":"270","volume":"4","author":"MY Eisa","year":"2015","unstructured":"Eisa, M. Y., Al Dabbas, M. & Abdulla, F. H. Quantitative identification of phosphate using X-ray diffraction and fourier transform infrared (FTIR) spectroscopy. Int. J. Curr. Microbiol. App Sci. 4, 270\u2013283 (2015).","journal-title":"Int. J. Curr. Microbiol. App Sci."},{"key":"12729_CR55","doi-asserted-by":"publisher","first-page":"1259","DOI":"10.1021\/ma062140k","volume":"40","author":"D Tranchida","year":"2007","unstructured":"Tranchida, D., Piccarolo, S., Loos, J. & Alexeev, A. Mechanical characterization of polymers on a nanometer scale through nanoindentation. A study on pile-up and viscoelasticity. Macromolecules 40, 1259\u20131267 (2007).","journal-title":"Macromolecules"},{"key":"12729_CR56","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1557\/jmr.2004.19.1.3","volume":"19","author":"WC Oliver","year":"2004","unstructured":"Oliver, W. C. & Pharr, G. M. Measurement of hardness and elastic modulus by instrumented indentation: advances in Understanding and refinements to methodology. J. Mater. Res. 19, 3\u201320 (2004).","journal-title":"J. Mater. Res."},{"key":"12729_CR57","doi-asserted-by":"publisher","first-page":"1564","DOI":"10.1557\/JMR.1992.1564","volume":"7","author":"WC Oliver","year":"1992","unstructured":"Oliver, W. C. & Pharr, G. M. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments. J. Mater. Res. 7, 1564\u20131583 (1992).","journal-title":"J. Mater. Res."},{"key":"12729_CR58","doi-asserted-by":"publisher","first-page":"749","DOI":"10.2320\/matertrans.M2016437","volume":"58","author":"E Hasenhuetl","year":"2017","unstructured":"Hasenhuetl, E. et al. Evaluation of ion-irradiation hardening of tungsten single crystals by nanoindentation technique considering material pile-up effect. Mater. Trans. 58, 749\u2013756 (2017).","journal-title":"Mater. Trans."},{"key":"12729_CR59","doi-asserted-by":"publisher","first-page":"1010056","DOI":"10.3389\/fbioe.2022.1010056","volume":"10","author":"E Dall\u2019Ara","year":"2022","unstructured":"Dall\u2019Ara, E. & Tozzi, G. Digital volume correlation for the characterization of musculoskeletal tissues: current challenges and future developments. Front. Bioeng. Biotechnol. 10, 1010056 (2022).","journal-title":"Front. Bioeng. Biotechnol."},{"key":"12729_CR60","doi-asserted-by":"publisher","first-page":"915","DOI":"10.1002\/ar.21381","volume":"294","author":"PG Cox","year":"2011","unstructured":"Cox, P. G. & Jeffery, N. Reviewing the morphology of the jaw-closing musculature in squirrels, rats, and guinea pigs with contrast\u2010enhanced MicroCT. Anat. Record: Adv. Integr. Anat. Evolutionary Biology. 294, 915\u2013928 (2011).","journal-title":"Anat. Record: Adv. Integr. Anat. Evolutionary Biology"},{"key":"12729_CR61","doi-asserted-by":"publisher","first-page":"1208","DOI":"10.1017\/S1431927614001329","volume":"20","author":"J Buytaert","year":"2014","unstructured":"Buytaert, J., Goyens, J., De Greef, D., Aerts, P. & Dirckx, J. Volume shrinkage of bone, brain and muscle tissue in sample Preparation for micro-CT and light sheet fluorescence microscopy (LSFM). Microsc. Microanal. 20, 1208\u20131217 (2014).","journal-title":"Microsc. Microanal."},{"key":"12729_CR62","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1111\/joa.12068","volume":"223","author":"P Vickerton","year":"2013","unstructured":"Vickerton, P., Jarvis, J. & Jeffery, N. Concentration-dependent specimen shrinkage in iodine\u2010enhanced micro CT. J. Anat. 223, 185\u2013193 (2013).","journal-title":"J. Anat."},{"key":"12729_CR63","doi-asserted-by":"crossref","unstructured":"Dey, P. Springer,. Connective tissue stain: principle and procedure. In Basic and advanced laboratory techniques in histopathology and cytology 101\u2013111 (2023).","DOI":"10.1007\/978-981-19-6616-3_10"},{"key":"12729_CR64","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1093\/toxres\/tfad039","volume":"12","author":"SA Rupa","year":"2023","unstructured":"Rupa, S. A. et al. Interaction of mercury species with proteins: towards possible mechanism of mercurial toxicology. Toxicol. Res. (Camb). 12, 355\u2013368 (2023).","journal-title":"Toxicol. Res. (Camb)"},{"key":"12729_CR65","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1093\/rheumatology\/keg448","volume":"43","author":"G Riley","year":"2004","unstructured":"Riley, G. The pathogenesis of tendinopathy. A molecular perspective. Rheumatology 43, 131\u2013142 (2004).","journal-title":"Rheumatology"},{"key":"12729_CR66","doi-asserted-by":"publisher","first-page":"2642","DOI":"10.3390\/polym13162642","volume":"13","author":"R Naomi","year":"2021","unstructured":"Naomi, R., Ridzuan, P. M. & Bahari, H. Current insights into collagen type I. Polym. (Basel). 13, 2642 (2021).","journal-title":"Polym. (Basel)"},{"key":"12729_CR67","doi-asserted-by":"publisher","first-page":"4191","DOI":"10.1242\/dev.114777","volume":"142","author":"A Subramanian","year":"2015","unstructured":"Subramanian, A. & Schilling, T. F. Tendon development and musculoskeletal assembly: emerging roles for the extracellular matrix. Development 142, 4191\u20134204 (2015).","journal-title":"Development"},{"key":"12729_CR68","doi-asserted-by":"publisher","first-page":"116094","DOI":"10.1016\/j.bone.2021.116094","volume":"152","author":"E Goff","year":"2021","unstructured":"Goff, E. et al. Large-scale quantification of human osteocyte lacunar morphological biomarkers as assessed by ultra-high-resolution desktop micro-computed tomography. Bone 152, 116094 (2021).","journal-title":"Bone"},{"key":"12729_CR69","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1111\/nyas.13460","volume":"1409","author":"AH Lee","year":"2017","unstructured":"Lee, A. H. & Elliott, D. M. Freezing does not alter multiscale tendon mechanics and damage mechanisms in tension. Ann. N Y Acad. Sci. 1409, 85\u201394 (2017).","journal-title":"Ann. N Y Acad. Sci."},{"key":"12729_CR70","doi-asserted-by":"crossref","unstructured":"Liu, L. & Morgan, E. F. Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone. J. Biomech. 40, (2007).","DOI":"10.1016\/j.jbiomech.2007.04.019"},{"key":"12729_CR71","doi-asserted-by":"crossref","unstructured":"Palanca, M. et al. Local displacement and strain uncertainties in different bone types by digital volume correlation of synchrotron microtomograms. J. Biomech. 58, (2017).","DOI":"10.1016\/j.jbiomech.2017.04.007"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-12729-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-12729-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-12729-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,8]],"date-time":"2025-09-08T12:53:23Z","timestamp":1757336003000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-12729-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,2]]},"references-count":71,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["12729"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-12729-6","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,2]]},"assertion":[{"value":"30 January 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 July 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"28267"}}