{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T00:09:29Z","timestamp":1793318969966,"version":"4.5.0"},"reference-count":84,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T00:00:00Z","timestamp":1754956800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T00:00:00Z","timestamp":1754956800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Consejer\u00eda de Industria, Comercio y Empleo, Junta de Castilla y Le\u00f3n","award":["IN-VESTUN\/22\/LE\/0001"],"award-info":[{"award-number":["IN-VESTUN\/22\/LE\/0001"]}]},{"name":"Consejer\u00eda de Industria, Comercio y Empleo, Junta de Castilla y Le\u00f3n","award":["IN-VESTUN\/22\/LE\/0001"],"award-info":[{"award-number":["IN-VESTUN\/22\/LE\/0001"]}]},{"name":"Consejer\u00eda de Industria, Comercio y Empleo, Junta de Castilla y Le\u00f3n","award":["IN-VESTUN\/22\/LE\/0001"],"award-info":[{"award-number":["IN-VESTUN\/22\/LE\/0001"]}]},{"name":"Consejer\u00eda de Industria, Comercio y Empleo, Junta de Castilla y Le\u00f3n","award":["IN-VESTUN\/22\/LE\/0001"],"award-info":[{"award-number":["IN-VESTUN\/22\/LE\/0001"]}]},{"name":"Consejer\u00eda de Industria, Comercio y Empleo, Junta de Castilla y Le\u00f3n","award":["IN-VESTUN\/22\/LE\/0001"],"award-info":[{"award-number":["IN-VESTUN\/22\/LE\/0001"]}]},{"name":"Consejer\u00eda de Industria, Comercio y Empleo, Junta de Castilla y Le\u00f3n","award":["IN-VESTUN\/22\/LE\/0001"],"award-info":[{"award-number":["IN-VESTUN\/22\/LE\/0001"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-025-15636-y","type":"journal-article","created":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T07:20:53Z","timestamp":1754983253000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Effectiveness of cooling strategies for emergency personnel: a systematic review and meta-analysis"],"prefix":"10.1038","volume":"15","author":[{"given":"Jorge","family":"Guti\u00e9rrez-Arroyo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9157-1532","authenticated-orcid":false,"given":"Jose A.","family":"Rodr\u00edguez-Marroyo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fabio","family":"Garc\u00eda-Heras","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan","family":"Rodr\u00edguez-Medina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerardo","family":"Villa-Vicente","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2881-5645","authenticated-orcid":false,"given":"Bel\u00e9n","family":"Carballo-Leyenda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,8,12]]},"reference":[{"issue":"8","key":"15636_CR1","doi-asserted-by":"publisher","first-page":"839","DOI":"10.1007\/s00420-011-0614-y","volume":"84","author":"MJ Plat","year":"2011","unstructured":"Plat, M. J., Frings-Dresen, M. H. W. & Sluiter, J. K. A systematic review of job-specific workers\u2019 health surveillance activities for fire-fighting, ambulance, Police and military personnel. Int. Arch. Occup. Environ. Health. 84 (8), 839\u2013857 (2011).","journal-title":"Int. Arch. Occup. Environ. Health"},{"key":"15636_CR2","first-page":"521","volume":"63","author":"VR Nevola","year":"2019","unstructured":"Nevola, V. R., Lowe, M. D. & Marston, C. A. Review of methods to identify the critical job-tasks undertaken by the emergency services. Work 63, 521\u2013536 (2019).","journal-title":"Work"},{"issue":"9","key":"15636_CR3","doi-asserted-by":"publisher","first-page":"1465","DOI":"10.1080\/00140139.2013.818719","volume":"56","author":"GP Horn","year":"2013","unstructured":"Horn, G. P., Blevins, S., Fernhall, B. & Smith, D. L. Core temperature and heart rate response to repeated bouts of firefighting activities. Ergonomics 56 (9), 1465\u20131473 (2013).","journal-title":"Ergonomics"},{"issue":"2","key":"15636_CR4","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1007\/s00420-011-0661-4","volume":"85","author":"JA Rodr\u00edguez-Marroyo","year":"2012","unstructured":"Rodr\u00edguez-Marroyo, J. A. et al. Physiological work demands of Spanish wildland firefighters during wildfire suppression. Int. Arch. Occup. Environ. Health. 85 (2), 221\u2013228 (2012).","journal-title":"Int. Arch. Occup. Environ. Health"},{"issue":"9","key":"15636_CR5","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1136\/emermed-2011-200485","volume":"29","author":"N Callender","year":"2012","unstructured":"Callender, N., Ellerton, J. & Macdonald, J. H. Physiological demands of mountain rescue work. Emerg. Med. J. 29 (9), 753\u2013757 (2012).","journal-title":"Emerg. Med. J."},{"issue":"6","key":"15636_CR6","doi-asserted-by":"publisher","first-page":"1667","DOI":"10.1007\/s10694-015-0555-1","volume":"52","author":"JM Willi","year":"2016","unstructured":"Willi, J. M., Horn, G. P. & Madrzykowski, D. Characterizing a firefighter\u2019s immediate thermal environment in live-fire training scenarios. Fire Technol. 52 (6), 1667\u20131696 (2016).","journal-title":"Fire Technol."},{"key":"15636_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fphys.2019.00949","volume":"10","author":"B Carballo-Leyenda","year":"2019","unstructured":"Carballo-Leyenda, B. et al. Characterizing wildland firefighters\u2019 thermal environment during live-fire suppression. Front. Physiol. 10, 1\u20138 (2019).","journal-title":"Front. Physiol."},{"issue":"5","key":"15636_CR8","doi-asserted-by":"publisher","first-page":"329","DOI":"10.2165\/00007256-200029050-00004","volume":"29","author":"SS Cheung","year":"2000","unstructured":"Cheung, S. S., McLellan, T. M. & Tenaglia, S. The thermophysiology of uncompensable heat stress physiological manipulations and individual characteristics. Sports Med. 29 (5), 329\u2013359 (2000).","journal-title":"Sports Med."},{"key":"15636_CR9","doi-asserted-by":"publisher","first-page":"959","DOI":"10.7205\/MILMED-D-11-00052","volume":"176","author":"IB Stewart","year":"2011","unstructured":"Stewart, I. B., Rojek, A. M. & Hunt, A. P. Heat strain during explosive ordnance disposal. Mil Med. 176, 959\u2013963 (2011).","journal-title":"Mil Med."},{"key":"15636_CR10","doi-asserted-by":"publisher","first-page":"103064","DOI":"10.1016\/j.apergo.2020.103064","volume":"85","author":"MJ Maley","year":"2020","unstructured":"Maley, M. J. et al. Extending work tolerance time in the heat in protective ensembles with pre- and per-cooling methods. Appl. Ergon. 85, 103064 (2020).","journal-title":"Appl. Ergon."},{"issue":"1","key":"15636_CR11","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1016\/j.apergo.2009.07.001","volume":"41","author":"D Barr","year":"2010","unstructured":"Barr, D., Gregson, W. & Reilly, T. The thermal ergonomics of firefighting reviewed. Appl. Ergon. 41 (1), 161\u2013172 (2010).","journal-title":"Appl. Ergon."},{"key":"15636_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fphys.2018.01139","volume":"9","author":"B Carballo-Leyenda","year":"2018","unstructured":"Carballo-Leyenda, B. et al. Fractional contribution of wildland firefighters\u2019 personal protective equipment on physiological strain. Front. Physiol. 9, 1\u201310 (2018).","journal-title":"Front. Physiol."},{"issue":"6","key":"15636_CR13","doi-asserted-by":"publisher","first-page":"747","DOI":"10.1080\/00140130802550216","volume":"52","author":"SJ Petruzzello","year":"2009","unstructured":"Petruzzello, S. J. et al. Perceptual and physiological heat strain: examination in firefighters in laboratory- and field-based studies. Ergonomics 52 (6), 747\u2013754 (2009).","journal-title":"Ergonomics"},{"key":"15636_CR14","doi-asserted-by":"publisher","first-page":"442","DOI":"10.1016\/j.apergo.2016.10.001","volume":"59","author":"CL Butts","year":"2017","unstructured":"Butts, C. L. et al. Physiological and perceptual effects of a cooling garment during simulated industrial work in the heat. Appl. Ergon. 59, 442\u2013448 (2017).","journal-title":"Appl. Ergon."},{"key":"15636_CR15","doi-asserted-by":"publisher","first-page":"100420","DOI":"10.1016\/j.wace.2022.100420","volume":"35","author":"A Hall","year":"2022","unstructured":"Hall, A. et al. Spatial analysis of outdoor wet bulb Globe temperature under RCP4.5 and RCP8.5 scenarios for 2041\u20132080 across a range of temperate to hot climates. Weather Clim. Extrem. 35, 100420 (2022).","journal-title":"Weather Clim. Extrem"},{"issue":"5","key":"15636_CR16","doi-asserted-by":"publisher","first-page":"187","DOI":"10.3390\/atmos9050187","volume":"9","author":"D Newth","year":"2018","unstructured":"Newth, D. & Gunasekera, D. Projected changes in wet-bulb Globe temperature under alternative climate scenarios. Atmosphere 9 (5), 187 (2018).","journal-title":"Atmosphere"},{"issue":"9","key":"15636_CR17","doi-asserted-by":"publisher","first-page":"5675","DOI":"10.3390\/ijerph20095675","volume":"20","author":"AP Hunt","year":"2023","unstructured":"Hunt, A. P. et al. Climate change effects on the predicted heat strain and labour capacity of outdoor workers in Australia. Int. J. Environ. Res. Public. Health. 20 (9), 5675 (2023).","journal-title":"Int. J. Environ. Res. Public. Health"},{"issue":"5","key":"15636_CR18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/biology12050695","volume":"12","author":"M Brearley","year":"2023","unstructured":"Brearley, M. et al. A systematic review of post-work core temperature cooling rates conferred by passive rest. Biology 12 (5), 1\u201316 (2023).","journal-title":"Biology"},{"key":"15636_CR19","doi-asserted-by":"crossref","unstructured":"Hadid, A. et al. Effect of a personal ambient ventilation system on physiological strain during heat stress wearing a ballistic vest. Eur J. Appl. Physiol 311\u2013319 (2008).","DOI":"10.1007\/s00421-008-0716-8"},{"key":"15636_CR20","doi-asserted-by":"crossref","unstructured":"Alhadad, S. B., Tan, P. M. S. & Lee, J. K. W. Efficacy of heat mitigation strategies on core temperature and endurance exercise: a meta-analysis. Front Physiol 10 (2019).","DOI":"10.3389\/fphys.2019.00071"},{"issue":"3","key":"15636_CR21","doi-asserted-by":"publisher","first-page":"328","DOI":"10.1080\/001401398187071","volume":"41","author":"Y Aoyagi","year":"1998","unstructured":"Aoyagi, Y., McLellan, T. M. & Shephard, R. J. Effects of endurance training and heat acclimation on psychological strain in exercising men wearing protective clothing. Ergonomics 41 (3), 328\u2013357 (1998).","journal-title":"Ergonomics"},{"issue":"6","key":"15636_CR22","doi-asserted-by":"publisher","first-page":"377","DOI":"10.1136\/bjsports-2013-092928","volume":"49","author":"CCWG Bongers","year":"2015","unstructured":"Bongers, C. C. W. G. et al. Precooling and percooling (cooling during exercise) both improve performance in the heat: a meta-analytical review. Br. J. Sports Med. 49 (6), 377\u2013384 (2015).","journal-title":"Br. J. Sports Med."},{"issue":"1","key":"15636_CR23","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13728-015-0034-9","volume":"4","author":"M Brearley","year":"2015","unstructured":"Brearley, M. & Walker, A. Water immersion for post incident cooling of firefighters; a review of practical fire ground cooling modalities. Extrem Physiol. Med. 4 (1), 1\u201313 (2015).","journal-title":"Extrem Physiol. Med."},{"issue":"2","key":"15636_CR24","doi-asserted-by":"publisher","first-page":"241","DOI":"10.3109\/10903127.2012.749965","volume":"17","author":"SJ McEntire","year":"2013","unstructured":"McEntire, S. J., Suyama, J. & Hostler, D. Mitigation and prevention of exertional heat stress in firefighters: a review of cooling strategies for structural firefighting and hazardous materials responders. Prehosp Emerg. Care. 17 (2), 241\u2013260 (2013).","journal-title":"Prehosp Emerg. Care"},{"key":"15636_CR25","doi-asserted-by":"publisher","first-page":"103236","DOI":"10.1016\/j.jtherbio.2022.103236","volume":"106","author":"HHK Fullagar","year":"2022","unstructured":"Fullagar, H. H. K. et al. Cooling strategies for firefighters: effects on physiological, physical, and visuo-motor outcomes following fire-fighting tasks in the heat. J. Therm. Biol. 106, 103236 (2022).","journal-title":"J. Therm. Biol."},{"issue":"2","key":"15636_CR26","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1007\/s40279-023-01940-y","volume":"54","author":"TM van de Kerkhof","year":"2024","unstructured":"van de Kerkhof, T. M. et al. Performance benefits of pre- and per-cooling on self-paced versus constant workload exercise: a systematic review and meta-analysis. Sports Med. 54 (2), 447\u2013471 (2024).","journal-title":"Sports Med."},{"issue":"4","key":"15636_CR27","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1080\/00140130802707675","volume":"52","author":"D Barr","year":"2009","unstructured":"Barr, D., Gregson, W., Sutton, L. & Reilly, T. A practical cooling strategy for reducing the physiological strain associated with firefighting activity in the heat. Ergonomics 52 (4), 413\u2013420 (2009).","journal-title":"Ergonomics"},{"issue":"10","key":"15636_CR28","doi-asserted-by":"publisher","first-page":"1159","DOI":"10.1139\/apnm-2014-0038","volume":"39","author":"A Walker","year":"2014","unstructured":"Walker, A. et al. Cold-water immersion and iced-slush ingestion are effective at cooling firefighters following a simulated search and rescue task in a hot environment. Appl. Physiol. Nutr. Metab. 39 (10), 1159\u20131166 (2014).","journal-title":"Appl. Physiol. Nutr. Metab."},{"key":"15636_CR29","unstructured":"Bennett, B. L., Hagan, R. D., Huey, K. A. & Williams, F. Use of a cool vest to reduce heat strain during shipboard firefighting. Naval Health Res. Cent. (1994)."},{"key":"15636_CR30","unstructured":"Frim, J. & Morris, A. Evaluation of personal cooling systems in conjunction with explosive ordnance disposal suits. Def. Civ. Inst. Environ. Med. 1\u201364 (1992)."},{"key":"15636_CR31","doi-asserted-by":"publisher","first-page":"1207","DOI":"10.1007\/s00421-010-1748-4","volume":"111","author":"C Gao","year":"2011","unstructured":"Gao, C., Kuklane, K. & Holm\u00e9r, I. Cooling vests with phase change materials: the effects of melting temperature on heat strain alleviation in an extremely hot environment. Eur. J. Appl. Physiol. 111, 1207\u20131216 (2011).","journal-title":"Eur. J. Appl. Physiol."},{"key":"15636_CR32","unstructured":"Hagan, R. D., Huey, K. A. & Bennett, B. L. Cool vests work under firefighting ensemble. Def. Tech. Inf. Cent. (1994)."},{"issue":"2","key":"15636_CR33","doi-asserted-by":"publisher","first-page":"299","DOI":"10.1080\/001401399185667","volume":"42","author":"JB Carter","year":"1999","unstructured":"Carter, J. B. Effectiveness of rest pauses and cooling in alleviation of heat stress during simulated fire-fighting activity. Ergonomics 42 (2), 299\u2013213 (1999).","journal-title":"Ergonomics"},{"issue":"2","key":"15636_CR34","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1016\/j.jtherbio.2006.12.001","volume":"32","author":"JM Carter","year":"2007","unstructured":"Carter, J. M. et al. Strategies to combat heat strain during and after firefighting. J. Therm. Biol. 32 (2), 109\u2013116 (2007).","journal-title":"J. Therm. Biol."},{"issue":"2","key":"15636_CR35","doi-asserted-by":"publisher","first-page":"226","DOI":"10.3109\/10903127.2010.545482","volume":"15","author":"D Colburn","year":"2011","unstructured":"Colburn, D. et al. A comparison of cooling techniques in firefighters after a live burn evolution. Prehosp Emerg. Care. 15 (2), 226\u2013232 (2011).","journal-title":"Prehosp Emerg. Care"},{"issue":"1","key":"15636_CR36","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1136\/bjsports-2012-091739","volume":"49","author":"CJ Tyler","year":"2015","unstructured":"Tyler, C. J., Sunderland, C. & Cheung, S. S. The effect of cooling prior to and during exercise on exercise performance and capacity in the heat: a meta-analysis. Br. J. Sports Med. 49 (1), 7\u201313 (2015).","journal-title":"Br. J. Sports Med."},{"issue":"2","key":"15636_CR37","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1080\/00140139408963645","volume":"37","author":"SH Constable","year":"1994","unstructured":"Constable, S. H. et al. Intermittent microclimate cooling during rest increases work capacity and reduces heat stress. Ergonomics 37 (2), 277\u2013285 (1994).","journal-title":"Ergonomics"},{"issue":"6","key":"15636_CR38","doi-asserted-by":"publisher","first-page":"959","DOI":"10.1007\/s00421-010-1714-1","volume":"111","author":"D Barr","year":"2011","unstructured":"Barr, D., Reilly, T. & Gregson, W. The impact of different cooling modalities on the physiological responses in firefighters during strenuous work performed in high environmental temperatures. Eur. J. Appl. Physiol. 111 (6), 959\u2013967 (2011).","journal-title":"Eur. J. Appl. Physiol."},{"issue":"3","key":"15636_CR39","doi-asserted-by":"publisher","first-page":"300","DOI":"10.3109\/10903121003770654","volume":"14","author":"D Hostler","year":"2010","unstructured":"Hostler, D. et al. Comparison of active cooling devices with passive cooling for rehabilitation of firefighters performing exercise in thermal protective clothing: a report from the fireground rehab evaluation (FIRE) trial. Prehosp Emerg. Care. 14 (3), 300\u2013309 (2010).","journal-title":"Prehosp Emerg. Care"},{"issue":"8","key":"15636_CR40","doi-asserted-by":"publisher","first-page":"521","DOI":"10.1080\/15459620490475216","volume":"1","author":"GA Selkirk","year":"2004","unstructured":"Selkirk, G. A., McLellan, T. M. & Wong, J. Active versus passive cooling during work in warm environments while wearing firefighting protective clothing. J. Occup. Environ. Hyg. 1 (8), 521\u2013531 (2004).","journal-title":"J. Occup. Environ. Hyg."},{"issue":"11","key":"15636_CR41","doi-asserted-by":"publisher","first-page":"927","DOI":"10.4085\/1062-6050-51.10.09","volume":"51","author":"S Yeargin","year":"2016","unstructured":"Yeargin, S. et al. Physiological and perceived effects of forearm or head cooling during simulated firefighting activity and rehabilitation. J. Athl Train. 51 (11), 927\u2013935 (2016).","journal-title":"J. Athl Train."},{"issue":"2","key":"15636_CR42","doi-asserted-by":"publisher","first-page":"66","DOI":"10.15171\/hpp.2017.13","volume":"7","author":"R Hemmatjo","year":"2017","unstructured":"Hemmatjo, R. et al. The effect of practical cooling strategies on physiological response and cognitive function during simulated firefighting tasks. Health Promot Perspect. 7 (2), 66\u201373 (2017).","journal-title":"Health Promot Perspect."},{"key":"15636_CR43","first-page":"4521","volume":"92","author":"J Li","year":"2021","unstructured":"Li, J. et al. Efficacy of cooling garments on exertional heat strain recovery in firefighters: a systematic review and meta-analysis. Text. Res. J. 92, 4521\u20134535 (2021).","journal-title":"Text. Res. J."},{"key":"15636_CR44","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1002\/ajim.23672","volume":"68","author":"EJ Tetzlaff","year":"2025","unstructured":"Tetzlaff, E. J. et al. Practical considerations for using personal cooling garments for heat stress management in physically demanding occupations: a systematic review and meta-analysis using realist evaluation. Am. J. Ind. Med. 68, 3\u201325 (2025).","journal-title":"Am. J. Ind. Med."},{"key":"15636_CR45","doi-asserted-by":"publisher","first-page":"n71","DOI":"10.1136\/bmj.n71","volume":"372","author":"MJ Page","year":"2021","unstructured":"Page, M. J. et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ 372, n71 (2021).","journal-title":"BMJ"},{"key":"15636_CR46","doi-asserted-by":"publisher","first-page":"1019","DOI":"10.1016\/j.apergo.2013.12.006","volume":"45","author":"SY Son","year":"2014","unstructured":"Son, S. Y. et al. Comparison of firefighters and non-firefighters and the test methods used regarding the effects of personal protective equipment on individual mobility. Appl. Ergon. 45, 1019\u20131027 (2014).","journal-title":"Appl. Ergon."},{"key":"15636_CR47","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.jtherbio.2015.01.007","volume":"49\u201350","author":"APC Chan","year":"2015","unstructured":"Chan, A. P. C., Song, W. & Yang, Y. Meta-analysis of the effects of microclimate cooling systems on human performance under thermal stressful environments: potential applications to occupational workers. J. Therm. Biol. 49\u201350, 16\u201332 (2015).","journal-title":"J. Therm. Biol."},{"issue":"5","key":"15636_CR48","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1017\/S1049023X15005038","volume":"30","author":"T Keene","year":"2015","unstructured":"Keene, T. et al. Accuracy of tympanic temperature measurement in firefighters completing a simulated structural firefighting task. Prehosp Disaster Med. 30 (5), 461\u2013465 (2015).","journal-title":"Prehosp Disaster Med."},{"issue":"3","key":"15636_CR49","first-page":"333","volume":"42","author":"DJ Casa","year":"2007","unstructured":"Casa, D. J. et al. Validity of devices that assess body temperature during outdoor exercise in the heat. J. Athl Train. 42 (3), 333 (2007).","journal-title":"J. Athl Train."},{"issue":"2","key":"15636_CR50","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1177\/0145445516673998","volume":"41","author":"D Drevon","year":"2017","unstructured":"Drevon, D., Fursa, S. R. & Malcolm, A. L. Intercoder reliability and validity of webplotdigitizer in extracting graphed data. Behav. Modif. 41 (2), 323\u2013339 (2017).","journal-title":"Behav. Modif."},{"key":"15636_CR51","doi-asserted-by":"crossref","unstructured":"Liberati, A. et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. PLoS Med 6(7) (2009).","DOI":"10.1371\/journal.pmed.1000100"},{"issue":"1","key":"15636_CR52","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1080\/23328940.2016.1277003","volume":"4","author":"CCWG Bongers","year":"2017","unstructured":"Bongers, C. C. W. G., Hopman, M. T. E. & Eijsvogels, T. M. H. Cooling interventions for athletes: an overview of effectiveness, physiological mechanisms, and practical considerations. Temperature 4 (1), 60\u201378 (2017).","journal-title":"Temperature"},{"issue":"7","key":"15636_CR53","doi-asserted-by":"publisher","first-page":"668","DOI":"10.1016\/j.jclinepi.2005.01.002","volume":"58","author":"SK Bhogal","year":"2005","unstructured":"Bhogal, S. K. et al. The PEDro scale provides a more comprehensive measure of methodological quality than the Jadad scale in stroke rehabilitation literature. J. Clin. Epidemiol. 58 (7), 668\u2013673 (2005).","journal-title":"J. Clin. Epidemiol."},{"issue":"12","key":"15636_CR54","doi-asserted-by":"publisher","first-page":"3488","DOI":"10.1519\/JSC.0b013e3181fb3e15","volume":"24","author":"GF Ranalli","year":"2010","unstructured":"Ranalli, G. F. et al. Effect of body cooling on subsequent aerobic and anaerobic exercise performance: a systematic review. Strength. Cond. 24 (12), 3488\u20133496 (2010).","journal-title":"Strength. Cond"},{"key":"15636_CR55","unstructured":"Higgins, J. P. T. et al. Cochrane Handbook for Systematic Reviews of Interventions version 6.4. Cochrane; (2023). www.training.cochrane.org\/handbook"},{"key":"15636_CR56","doi-asserted-by":"crossref","unstructured":"Borenstein, M. et al. Introduction To meta-analysis (Wiley, 2021).","DOI":"10.1002\/9781119558378"},{"key":"15636_CR57","unstructured":"Cohen, J. S. Statistical Power Analysis for the Behavioral Sciences 2nd edn (Lawrence Erlbaum, 1988)."},{"issue":"3","key":"15636_CR58","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/0197-2456(86)90046-2","volume":"7","author":"R DerSimonian","year":"1986","unstructured":"DerSimonian, R. & Laird, N. Meta-analysis in clinical trials. Control Clin. Trials. 7 (3), 177\u2013188 (1986).","journal-title":"Control Clin. Trials"},{"issue":"7414","key":"15636_CR59","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","volume":"327","author":"JPT Higgins","year":"2003","unstructured":"Higgins, J. P. T. Measuring inconsistency in meta-analyses. BMJ 327 (7414), 557\u2013560 (2003).","journal-title":"BMJ"},{"issue":"7109","key":"15636_CR60","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1136\/bmj.315.7109.629","volume":"315","author":"M Egger","year":"1997","unstructured":"Egger, M. et al. Bias in meta-analysis detected by a simple, graphical test. BMJ 315 (7109), 629\u2013634 (1997).","journal-title":"BMJ"},{"key":"15636_CR61","doi-asserted-by":"publisher","first-page":"322","DOI":"10.1007\/BF00865029","volume":"70","author":"BL Bennett","year":"1995","unstructured":"Bennett, B. L. et al. Comparison of two cool vests on heat-strain reduction while wearing a firefighting ensemble. Eur. J. Appl. Physiol. Occup. Physiol. 70, 322\u2013328 (1995).","journal-title":"Eur. J. Appl. Physiol. Occup. Physiol."},{"key":"15636_CR62","unstructured":"Ram\u00edrez, L. R. et al. Cool Vest Worn Under Firefighting Ensemble Reduces Heat Strain during Exercise and Recovery (Naval Health Research Center, 1994)."},{"issue":"11","key":"15636_CR63","doi-asserted-by":"publisher","first-page":"936","DOI":"10.4085\/1062-6050-51.10.13","volume":"51","author":"JM Sefton","year":"2016","unstructured":"Sefton, J. M. et al. Evaluation of 2 heat-mitigation methods in army trainees. J. Athl Train. 51 (11), 936\u2013945 (2016).","journal-title":"J. Athl Train."},{"issue":"4","key":"15636_CR64","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1080\/00140130600558007","volume":"49","author":"GA Selkirk","year":"2006","unstructured":"Selkirk, G. A., McLellan, T. M. & Wong, J. The impact of various rehydration volumes for firefighters wearing protective clothing in warm environments. Ergonomics 49 (4), 418\u2013433 (2006).","journal-title":"Ergonomics"},{"issue":"1","key":"15636_CR65","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/1348-9585.12263","volume":"63","author":"S Tabuchi","year":"2021","unstructured":"Tabuchi, S. et al. Efficacy of ice slurry and carbohydrate\u2013electrolyte solutions for firefighters. J. Occup. Health. 63 (1), 1\u201311 (2021).","journal-title":"J. Occup. Health"},{"issue":"8","key":"15636_CR66","doi-asserted-by":"publisher","first-page":"811","DOI":"10.1139\/apnm-2015-0067","volume":"40","author":"PJ Wallace","year":"2015","unstructured":"Wallace, P. J. et al. The effects of cranial cooling during recovery on subsequent uncompensable heat stress tolerance. Appl. Physiol. Nutr. Metab. 40 (8), 811\u2013816 (2015).","journal-title":"Appl. Physiol. Nutr. Metab."},{"issue":"11","key":"15636_CR67","doi-asserted-by":"publisher","first-page":"1660","DOI":"10.1111\/sms.13521","volume":"29","author":"W Douzi","year":"2019","unstructured":"Douzi, W. et al. Cooling during exercise enhances performances, but the cooled body areas matter: a systematic review with meta-analyses. Scand. J. Med. Sci. Sports. 29 (11), 1660\u20131676 (2019).","journal-title":"Scand. J. Med. Sci. Sports"},{"key":"15636_CR68","doi-asserted-by":"crossref","unstructured":"Douzi, W. et al. Per-cooling (using cooling systems during physical exercise) enhances physical and cognitive performances in hot environments. Int J. Environ. Res. Public. Health 17(3) (2020).","DOI":"10.3390\/ijerph17031031"},{"issue":"4","key":"15636_CR69","doi-asserted-by":"publisher","first-page":"1873","DOI":"10.1152\/physrev.00038.2020","volume":"101","author":"JD P\u00e9riard","year":"2021","unstructured":"P\u00e9riard, J. D., Eijsvogels, T. M. H. & Daanen, H. A. M. Exercise under heat stress: thermoregulation, hydration, performance implications, and mitigation strategies. Physiol. Rev. 101 (4), 1873\u20131879 (2021).","journal-title":"Physiol. Rev."},{"issue":"7","key":"15636_CR70","doi-asserted-by":"publisher","first-page":"545","DOI":"10.2165\/11630550-000000000-00000","volume":"42","author":"M Wegmann","year":"2012","unstructured":"Wegmann, M. et al. Pre-cooling and sports performance: a meta-analytical review. Sports Med. 42 (7), 545\u2013564 (2012).","journal-title":"Sports Med."},{"issue":"S1","key":"15636_CR71","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1007\/s40279-017-0842-8","volume":"48","author":"O Jay","year":"2018","unstructured":"Jay, O. & Morris, N. B. Does cold water or ice slurry ingestion during exercise elicit a net body cooling effect in the heat? Sports Med. 48 (S1), 17\u201329 (2018).","journal-title":"Sports Med."},{"issue":"1\u20132","key":"15636_CR72","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1007\/PL00013782","volume":"81","author":"B Drust","year":"2000","unstructured":"Drust, B., Cable, N. T. & Reilly, T. Investigation of the effects of the pre-cooling on the physiological responses to soccer-specific intermittent exercise. Eur. J. Appl. Physiol. Occup. Physiol. 81 (1\u20132), 11\u201317 (2000).","journal-title":"Eur. J. Appl. Physiol. Occup. Physiol."},{"key":"15636_CR73","doi-asserted-by":"publisher","first-page":"1883","DOI":"10.1002\/j.2040-4603.2011.tb00385.x","volume":"1","author":"MN Sawka","year":"2011","unstructured":"Sawka, M. N. et al. Integrated physiological mechanisms of exercise performance, adaptation, and maladaptation to heat stress. Compr. Physiol. 1, 1883\u20131928 (2011).","journal-title":"Compr. Physiol."},{"issue":"1","key":"15636_CR74","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1249\/MSS.0b013e3181e93210","volume":"43","author":"MLR Ross","year":"2011","unstructured":"Ross, M. L. R. et al. Novel precooling strategy enhances time trial cycling in the heat. Med. Sci. Sports Exerc. 43 (1), 123\u2013133 (2011).","journal-title":"Med. Sci. Sports Exerc."},{"key":"15636_CR75","doi-asserted-by":"crossref","unstructured":"Bach, A. J. E. et al. An evaluation of personal cooling systems for reducing thermal strain whilst working in chemical\/biological protective clothing. Front Physiol 10 (2019).","DOI":"10.3389\/fphys.2019.00424"},{"issue":"8","key":"15636_CR76","first-page":"802","volume":"70","author":"T McLellan","year":"1999","unstructured":"McLellan, T., Frim, J. & Bell, D. G. Efficacy of air and liquid cooling during light and heavy exercise while wearing NBC clothing. Aviat. Space Environ. Med. 70 (8), 802\u2013811 (1999).","journal-title":"Aviat. Space Environ. Med."},{"issue":"2","key":"15636_CR77","first-page":"25","volume":"20","author":"M Brearley","year":"2012","unstructured":"Brearley, M. Crushed ice ingestion-A practical strategy for Lowering core body temperature. J. Mil Veterans Health. 20 (2), 25\u201330 (2012).","journal-title":"J. Mil Veterans Health"},{"issue":"4","key":"15636_CR78","doi-asserted-by":"publisher","first-page":"717","DOI":"10.1249\/MSS.0b013e3181bf257a","volume":"42","author":"R Siegel","year":"2010","unstructured":"Siegel, R. et al. Ice slurry ingestion increases core temperature capacity and running time in the heat. Med. Sci. Sports Exerc. 42 (4), 717\u2013725 (2010).","journal-title":"Med. Sci. Sports Exerc."},{"issue":"S1","key":"15636_CR79","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1111\/sms.12366","volume":"25","author":"PMS Tan","year":"2015","unstructured":"Tan, P. M. S. & Lee, J. K. W. The role of fluid temperature and form on endurance performance in the heat. Scand. J. Med. Sci. Sports. 25 (S1), 39\u201351 (2015).","journal-title":"Scand. J. Med. Sci. Sports"},{"issue":"2","key":"15636_CR80","doi-asserted-by":"publisher","first-page":"241","DOI":"10.3109\/10903127.2014.959221","volume":"19","author":"RR Pryor","year":"2015","unstructured":"Pryor, R. R. et al. The effects of ice slurry ingestion before exertion in wildland firefighting gear. Prehosp Emerg. Care. 19 (2), 241\u2013246 (2015).","journal-title":"Prehosp Emerg. Care"},{"key":"15636_CR81","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1016\/j.apergo.2018.01.011","volume":"70","author":"ER Watkins","year":"2018","unstructured":"Watkins, E. R. et al. Practical pre-cooling methods for occupational heat exposure. Appl. Ergon. 70, 26\u201333 (2018).","journal-title":"Appl. Ergon."},{"key":"15636_CR82","doi-asserted-by":"crossref","unstructured":"Carballo-Leyenda, B. et al. Perceptions of heat stress, heat strain and mitigation practices in wildfire suppression across Southern Europe and Latin America. Int J. Environ. Res. Public. Health 19(19) (2022).","DOI":"10.3390\/ijerph191912288"},{"key":"15636_CR83","doi-asserted-by":"publisher","first-page":"103449","DOI":"10.1016\/j.apergo.2021.103449","volume":"95","author":"HHK Fullagar","year":"2021","unstructured":"Fullagar, H. H. K. et al. Australian firefighters perceptions of heat stress, fatigue and recovery practices during fire-fighting tasks in extreme environments. Appl. Ergon. 95, 103449 (2021).","journal-title":"Appl. Ergon."},{"issue":"4","key":"15636_CR84","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1080\/23328940.2018.1493907","volume":"5","author":"AJE Bach","year":"2018","unstructured":"Bach, A. J. E. et al. Occupational cooling practices of emergency first responders in the united states: a survey. Temperature 5 (4), 348\u2013358 (2018).","journal-title":"Temperature"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-15636-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-15636-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-15636-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,9]],"date-time":"2025-09-09T00:59:51Z","timestamp":1757379591000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-15636-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,12]]},"references-count":84,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["15636"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-15636-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,12]]},"assertion":[{"value":"10 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 August 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 August 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"29492"}}