{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T15:47:50Z","timestamp":1774626470703,"version":"3.50.1"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T00:00:00Z","timestamp":1759449600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T00:00:00Z","timestamp":1759449600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Carl Gustav Carus Dresden an der Technischen Universit\u00e4t Dresden"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>To investigate the repeatability and reproducibility of manual measurements of the reflectivity of retinal layers in healthy eyes and in eyes with acute retinal vessel occlusion via spectral-domain optical coherence tomography (SD-OCT). To reflect the full spectrum of different reflectivities seen in OCT images, for each of the following conditions, exactly one patient with a healthy and an affected eye was selected: non-ischemic central retinal vein occlusion (CRVO), ischemic CRVO, incomplete, subtotal and total central retinal artery occlusion (CRAO). For all the patients, OCT images of the healthy and affected eyes were used. Each image was presented 10 times in a randomly changing sequence to all examiners (one experienced, two nonexperienced). The obtained values were analyzed via two statistical methods: Gage Repeatability &amp; Reproducibility (Gage R&amp;R, a measurement system analysis) and Lin\u2019s concordance correlation coefficient (Lin\u2019s CCC). The total gage R&amp;R values were as follows: vitreous body (VB) 1.11%, innermost retinal layer (IMRL) 0.94%, middle retinal layer (MRL) 4.94%, inner retinal layer (IRL) 2.56% and outer retinal layer (ORL) 3.77%. The repeatability values were 0.79, 0.62, 2.80, 1.42 And 2.60, respectively. The reproducibility values were 0.32, 0.33, 2.41, 1.14 and 1.16, respectively. Our previously described method of manual measurement of SD-OCT images of retinal layers determining the level of reflectivity (and hence ischemia) in the retina without any invasive examination is reliable, repeatable, reproducible and feasible for clinical use. Registry: ClinicalTrials.gov, Protocol ID: EK 417,102,016, TRN: NCT03061526, Registration date: 19 February 2017.<\/jats:p>","DOI":"10.1038\/s41598-025-20086-7","type":"journal-article","created":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T08:45:19Z","timestamp":1759481119000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Manual measurement of SD-OCT images of hyperreflective retinal layers in acute retinal vessel occlusion is reliable, repeatable and reproducible"],"prefix":"10.1038","volume":"15","author":[{"given":"Egbert","family":"Matth\u00e9","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dierk","family":"Wittig","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias","family":"Kuhn","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peggy","family":"Eulitz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katharina","family":"Schoen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dirk","family":"Sandner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Olga","family":"Furashova","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,10,3]]},"reference":[{"key":"20086_CR1","doi-asserted-by":"publisher","first-page":"139","DOI":"10.1159\/000455278","volume":"58","author":"JB Jonas","year":"2017","unstructured":"Jonas, J. B., Mon\u00e9s, J., Glacet-Bernard, A. & Coscas, G. Retinal vein occlusions. Dev. Ophthalmol. 58, 139\u2013167 (2017).","journal-title":"Dev. Ophthalmol."},{"key":"20086_CR2","doi-asserted-by":"publisher","unstructured":"Mohamed, Q., McIntosh, R. L., Saw, S. M. & Wong, T. Y. Interventions for Central Retinal Vein Occlusion. An Evidence-Based Systematic Review. Ophthalmology vol. 114 507\u2013519 at (2007). https:\/\/doi.org\/10.1016\/j.ophtha.2006.11.011","DOI":"10.1016\/j.ophtha.2006.11.011"},{"key":"20086_CR3","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1186\/s42466-022-00193-w","volume":"4","author":"C Hoyer","year":"2022","unstructured":"Hoyer, C. et al. Current diagnosis and treatment practice of central retinal artery occlusion: results from a survey among German stroke units. Neurol. Res. Pract. 4, 30 (2022).","journal-title":"Neurol. Res. Pract."},{"key":"20086_CR4","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1016\/j.preteyeres.2011.05.001","volume":"30","author":"SS Hayreh","year":"2011","unstructured":"Hayreh, S. S. Acute retinal arterial occlusive disorders. Prog Retin Eye Res. 30, 359\u2013394 (2011).","journal-title":"Prog Retin Eye Res."},{"key":"20086_CR5","doi-asserted-by":"publisher","first-page":"376e1","DOI":"10.1016\/j.ajo.2005.03.038","volume":"140","author":"SS Hayreh","year":"2005","unstructured":"Hayreh, S. S. & Zimmerman, M. B. Central retinal artery occlusion: visual outcome. Am. J. Ophthalmol. 140, 376e1\u2013376e (2005).","journal-title":"Am. J. Ophthalmol."},{"key":"20086_CR6","first-page":"1301","volume":"23","author":"DP Schmidt","year":"2002","unstructured":"Schmidt, D. P., Schulte-M\u00f6nting, J. & Schumacher, M. Prognosis of central retinal artery occlusion: local intraarterial fibrinolysis versus Conservative treatment. Am. J. Neuroradiol. 23, 1301\u20131307 (2002).","journal-title":"Am. J. Neuroradiol."},{"key":"20086_CR7","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1076\/noph.20.3.125.4155","volume":"20","author":"D Schmidt","year":"1998","unstructured":"Schmidt, D. & Schumacher, M. Stage-dependent efficacy of intra-arterial fibrinolysis in central retinal artery occlusion (CRAO). Neuro-Ophthalmology 20, 125\u2013141 (1998).","journal-title":"Neuro-Ophthalmology"},{"key":"20086_CR8","doi-asserted-by":"publisher","first-page":"1139","DOI":"10.1016\/S0161-6420(91)32165-1","volume":"98","author":"KA Kwiterovich","year":"1991","unstructured":"Kwiterovich, K. A. et al. Frequency of adverse systemic reactions after fluorescein angiography: results of a prospective study. Ophthalmology 98, 1139\u20131142 (1991).","journal-title":"Ophthalmology"},{"key":"20086_CR9","doi-asserted-by":"publisher","first-page":"5209","DOI":"10.1167\/iovs.17-22411","volume":"58","author":"O Furashova","year":"2017","unstructured":"Furashova, O. & Matth\u00e9, E. Retinal changes in different grades of retinal artery occlusion: an optical coherence tomography study. Investig Opthalmology Vis. Sci. 58, 5209 (2017).","journal-title":"Investig Opthalmology Vis. Sci."},{"key":"20086_CR10","doi-asserted-by":"publisher","first-page":"1118","DOI":"10.1097\/IAE.0000000000002527","volume":"40","author":"E Matth\u00e9","year":"2020","unstructured":"Matth\u00e9, E., Eulitz, P., Furashova, O., Acute retinal ischemia in central versus branch retinal artery occlusion: Changes in retinal layers\u2019 thickness on Spectral-Domain optical coherence tomography in different grades of retinal ischemia. Retina 40, 1118\u20131123 (2020).","journal-title":"Retina"},{"key":"20086_CR11","doi-asserted-by":"publisher","first-page":"1113","DOI":"10.1016\/j.ophtha.2010.01.060","volume":"117","author":"RL McIntosh","year":"2010","unstructured":"McIntosh, R. L. et al. Natural history of central retinal vein occlusion: an Evidence-Based systematic review. Ophthalmology 117, 1113\u20131123 (2010)","journal-title":"Ophthalmology"},{"key":"20086_CR12","doi-asserted-by":"publisher","first-page":"1425","DOI":"10.1016\/S0161-6420(95)30849-4","volume":"102","author":"JG Clarkson","year":"1995","unstructured":"Clarkson, J. G. et al. Evaluation of grid pattern photocoagulation for macular edema in central vein occlusion: the central vein occlusion study group M report. Ophthalmology 102, 1425\u20131433 (1995).","journal-title":"Ophthalmology"},{"key":"20086_CR13","doi-asserted-by":"crossref","unstructured":"The Central Vein Occlusion Study Group N Report. A Randomized Clinical Trial of Early Panretinal Photocoagulation for Ischermic Central Vein Occlusion. Ophthalmology vol. 102. (1995).","DOI":"10.1016\/S0161-6420(95)30848-2"},{"key":"20086_CR14","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1016\/j.preteyeres.2004.12.001","volume":"24","author":"SS Hayreh","year":"2005","unstructured":"Hayreh, S. S. Prevalent misconceptions about acute retinal vascular occlusive disorders. Prog Retin Eye Res. 24, 493\u2013519 (2005).","journal-title":"Prog Retin Eye Res."},{"key":"20086_CR15","doi-asserted-by":"publisher","first-page":"753","DOI":"10.1016\/j.oret.2022.02.007","volume":"6","author":"MR Munk","year":"2022","unstructured":"Munk, M. R. et al. Recommendations for OCT angiography reporting in retinal vascular disease. Ophthalmol. Retin. 6, 753\u2013761 (2022).","journal-title":"Ophthalmol. Retin"},{"key":"20086_CR16","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1186\/s12886-022-02637-y","volume":"22","author":"W An","year":"2022","unstructured":"An, W., Zhao, Q., Yu, R. & Han, J. The role of optical coherence tomography angiography in distinguishing ischemic versus non-ischemic central retinal vein occlusion. BMC Ophthalmol. 22, 413 (2022).","journal-title":"BMC Ophthalmol."},{"key":"20086_CR17","doi-asserted-by":"publisher","first-page":"1562","DOI":"10.1097\/IAE.0000000000001737","volume":"38","author":"D Seknazi","year":"2018","unstructured":"Seknazi, D. et al. Optical coherence tomography angiography in retinal vein occlusion. Retina 38, 1562\u20131570 (2018).","journal-title":"Retina"},{"key":"20086_CR18","doi-asserted-by":"publisher","first-page":"2018","DOI":"10.1161\/STROKEAHA.119.028743","volume":"51","author":"B Mac Grory","year":"2020","unstructured":"Mac Grory, B. et al. Intravenous fibrinolysis for central retinal artery occlusion. Stroke 51, 2018\u20132025 (2020).","journal-title":"Stroke"},{"key":"20086_CR19","unstructured":"ClinicalTrials.gov: Identifier NCT03197194. A, Phase, I. I. I. & Randomized Blind, Double Dummy, Multicenter Study Assessing the Efficacy and Safety of IV THrombolysis (Alteplase) in Patients With acutE Central retInal Artery Occlusion. (2017)."},{"key":"20086_CR20","unstructured":"ClinicalTrials.gov: Identifier NCT04965038. Early Reperfusion Therapy With Intravenous Alteplase for Recovery of VISION in Acute Central Retinal Artery Occlusion. (2021)."},{"key":"20086_CR21","unstructured":"Seong, O. et al. Efficacy and Safety of Intra-Arterial Thrombolysis in Central Retinal Artery. (2013)."},{"key":"20086_CR22","doi-asserted-by":"publisher","first-page":"38","DOI":"10.3928\/23258160-20131220-05","volume":"45","author":"G Dotan","year":"2014","unstructured":"Dotan, G. et al. The use of Spectral-Domain optical coherence tomography for differentiating Long-standing central retinal artery occlusion and nonarteritic anterior ischemic optic neuropathy. Ophthalmic Surg. Lasers Imaging Retin. 45, 38\u201344 (2014).","journal-title":"Ophthalmic Surg. Lasers Imaging Retin"},{"key":"20086_CR23","doi-asserted-by":"publisher","first-page":"502","DOI":"10.3928\/15428877-20061101-12","volume":"37","author":"SM Falkenberry","year":"2006","unstructured":"Falkenberry, S. M., Ip, M. S., Blodi, B. A. & Gunther, J. B. Optical coherence tomography findings in central retinal artery occlusion. Ophthalmic Surg. Lasers Imaging. 37, 502\u2013505 (2006).","journal-title":"Ophthalmic Surg. Lasers Imaging"},{"key":"20086_CR24","doi-asserted-by":"publisher","first-page":"110","DOI":"10.1097\/00006982-200601000-00021","volume":"26","author":"H Ozdemir","year":"2006","unstructured":"Ozdemir, H., Karacorlu, S. & Karacorlu, M. Optical coherence tomography findings in central retinal artery occlusion. Retina 26, 110\u2013112 (2006).","journal-title":"Retina"},{"key":"20086_CR25","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1016\/j.ajo.2015.01.001","volume":"159","author":"SJ Ahn","year":"2015","unstructured":"Ahn, S. J. et al. Retinal and choroidal changes and visual outcome in central retinal artery occlusion: an optical coherence tomography study. Am. J. Ophthalmol. 159, 667\u2013676e1 (2015).","journal-title":"Am. J. Ophthalmol."},{"key":"20086_CR26","doi-asserted-by":"publisher","first-page":"2453","DOI":"10.2147\/OPTH.S260000","volume":"14","author":"O Furashova","year":"2020","unstructured":"Furashova, O. & Matth\u00e8, E. Hyperreflectivity of inner retinal layers as a quantitative parameter of ischemic damage in acute retinal vein occlusion (RVO): an optical coherence tomography study. Clin. Ophthalmol. 14, 2453\u20132462 (2020).","journal-title":"Clin. Ophthalmol."},{"key":"20086_CR27","doi-asserted-by":"publisher","first-page":"9269","DOI":"10.1038\/srep09269","volume":"5","author":"H Chen","year":"2015","unstructured":"Chen, H. et al. Quantitative analysis of retinal layers\u2019 optical intensities on 3D optical coherence tomography for central retinal artery occlusion. Sci. Rep. 5, 9269 (2015).","journal-title":"Sci. Rep."},{"key":"20086_CR28","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1007\/s00417-011-1860-0","volume":"250","author":"M Ota","year":"2012","unstructured":"Ota, M. et al. Retinal sensitivity after resolution of the macular edema associated with retinal vein occlusion. Graefe\u2019s Arch. Clin. Exp. Ophthalmol. 250, 635\u2013644 (2012).","journal-title":"Graefe\u2019s Arch. Clin. Exp. Ophthalmol."},{"key":"20086_CR29","unstructured":"Automotive Industry Action Group (AIAG). Measurement System Analysis. in Automotive Industry Action Group (AIAG) Reference Manual. (2002)."},{"key":"20086_CR30","doi-asserted-by":"publisher","first-page":"342","DOI":"10.1080\/00224065.2003.11980232","volume":"35","author":"RK Burdick","year":"2003","unstructured":"Burdick, R. K., Borror, C. M. & Montgomery, D. C. A review of methods for measurement systems capability analysis. J. Qual. Technol. 35, 342\u2013354 (2003).","journal-title":"J. Qual. Technol."},{"key":"20086_CR31","doi-asserted-by":"publisher","unstructured":"Vardeman, S. B. & Jobe, J. M. Statistical Methods for Quality Assurance (Springer New York, 2016). https:\/\/doi.org\/10.1007\/978-0-387-79106-7","DOI":"10.1007\/978-0-387-79106-7"},{"key":"20086_CR32","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1080\/00224065.1998.11979835","volume":"30","author":"KK Dolezal","year":"1998","unstructured":"Dolezal, K. K., Burdick, R. K. & Birch, N. J. Analysis of a Two-Factor R&R study with fixed operators. J. Qual. Technol. 30, 163\u2013170 (1998).","journal-title":"J. Qual. Technol."},{"key":"20086_CR33","first-page":"1","volume":"20","author":"S Goffnett","year":"2004","unstructured":"Goffnett, S. Understanding six sigma: implications for industry and education. J. Ind. Technol. 20, 1\u201310 (2004).","journal-title":"J. Ind. Technol."},{"key":"20086_CR34","doi-asserted-by":"publisher","first-page":"289","DOI":"10.1080\/08982119308918725","volume":"6","author":"DC Montgomery","year":"1993","unstructured":"Montgomery, D. C. & Runger, G. C. Gauge capability analysis and designed experiments. part ii: experimental design models and variance component estimation. Qual. Eng. 6, 289\u2013305 (1993).","journal-title":"Qual. Eng."},{"key":"20086_CR35","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1080\/08982119308918710","volume":"6","author":"DC Montgomery","year":"1993","unstructured":"Montgomery, D. C. & Runger, G. C. Gauge Capability and designed experiments. part i: basic methods Qual. Eng. 6, 115\u2013135 (1993).","journal-title":"Qual. Eng."},{"key":"20086_CR36","doi-asserted-by":"publisher","first-page":"672","DOI":"10.1108\/02656710410542061","volume":"21","author":"J Pan","year":"2004","unstructured":"Pan, J. Determination of the optimal allocation of parameters for gauge repeatability and reproducibility study. Int. J. Qual. Reliab. Manag. 21, 672\u2013682 (2004).","journal-title":"Int. J. Qual. Reliab. Manag"},{"key":"20086_CR37","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1007\/s11135-005-1100-y","volume":"40","author":"JN Pan","year":"2006","unstructured":"Pan, J. N. Evaluating the gauge repeatability and reproducibility for different industries. Qual. Quant. 40, 499\u2013518 (2006).","journal-title":"Qual. Quant."},{"key":"20086_CR38","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1080\/08982119608919020","volume":"9","author":"M Persijn","year":"1996","unstructured":"Persijn, M., Nuland, Y. & Van Relation between measurement system capability and process capability. Qual. Eng. 9, 95\u201398 (1996).","journal-title":"Qual. Eng."},{"key":"20086_CR39","unstructured":"Smith, R. R., McCrary, S. W. & Callahan, R. N. Gauge repeatability and reproducibility studies and measurement system analysis: A multimethod exploration of the state of practice. J. Technol. Manag. Appl. Eng. 23 (2007)."},{"key":"20086_CR40","doi-asserted-by":"publisher","first-page":"255","DOI":"10.2307\/2532051","volume":"45","author":"L Lin","year":"1989","unstructured":"Lin, L. I. A concordance correlation coefficient to evaluate reproducibility. Biometrics 45, 255\u2013268 (1989).","journal-title":"Biometrics"},{"key":"20086_CR41","doi-asserted-by":"publisher","first-page":"599","DOI":"10.2307\/2532314","volume":"48","author":"LIK Lin","year":"1992","unstructured":"Lin, L. I. K. Assay validation using the concordance correlation coefficient. Biometrics 48, 599 (1992).","journal-title":"Biometrics"},{"key":"20086_CR42","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1111\/j.0006-341X.2000.00324.x","volume":"56","author":"L Lin","year":"2000","unstructured":"Lin, L. I.-K. A note on the concordance correlation coefficient. Biometrics 56, 324\u2013325 (2000).","journal-title":"Biometrics"},{"key":"20086_CR43","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1111\/j.0006-341X.2000.00324.x","volume":"56","author":"LIK Lin","year":"2000","unstructured":"Lin, L. I. K. Answer to note on the concordance correlation coefficient. Biometrics 56, 324\u2013325 (2000).","journal-title":"Biometrics"},{"key":"20086_CR44","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1198\/016214502753479392","volume":"97","author":"L L","year":"2002","unstructured":"L, L., Hedayat, A., M, Y. & B, S. & Statistical methods in assessing agreement: models, issues, and tools. J. Am. Stat. Assoc. 97, 257\u2013270 (2002).","journal-title":"J. Am. Stat. Assoc."},{"key":"20086_CR45","first-page":"307","volume":"2005-062 45","author":"GB McBride","year":"2005","unstructured":"McBride, G. B. A proposal for strength-of-agreement criteria for lin\u2019s concordance correlation coefficient. NIWA Client Rep. HAM. 2005-062 45, 307\u2013310 (2005).","journal-title":"NIWA Client Rep. HAM"},{"key":"20086_CR46","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/s12551-011-0054-7","volume":"3","author":"DP Popescu","year":"2011","unstructured":"Popescu, D. P. et al. Optical coherence tomography: fundamental principles, instrumental designs and biomedical applications. Biophys. Rev. 3, 155\u2013169 (2011).","journal-title":"Biophys. Rev."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-20086-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-20086-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-20086-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,3]],"date-time":"2025-10-03T08:45:21Z","timestamp":1759481121000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-20086-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,3]]},"references-count":46,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["20086"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-20086-7","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,3]]},"assertion":[{"value":"12 July 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 October 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"34471"}}