{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,24]],"date-time":"2025-11-24T16:46:58Z","timestamp":1764002818736,"version":"build-2065373602"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T00:00:00Z","timestamp":1760054400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T00:00:00Z","timestamp":1760054400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002957","name":"Technische Universit\u00e4t Dresden","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100002957","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:p>Active middle ear implants such as the Vibrant Soundbridge (VSB) represent effective treatment options for patients with conductive or mixed hearing loss when conventional hearing aids are insufficient. Nevertheless, postoperative speech intelligibility varies considerably, even among patients with comparable audiometric profiles. This first part of a two-part prospective observational study aimed to analyze outcomes and identify clinically accessible predictors of postoperative speech intelligibility. Twenty adults who underwent unilateral VSB implantation were included. Audiological assessments comprised postoperative bone conduction (BC), Vibrogram (VIB), free-field thresholds, maximum unaided speech intelligibility (WRS<jats:sub>max<\/jats:sub>), and aided speech intelligibility at 65 dB SPL (WRS<jats:sub>65dB<\/jats:sub>). Additional parameters included coupling efficiency, effective gain, dynamic range, loudness scaling, and patient-reported outcomes (PROMs; IOI-HA, SSQ12). Key predictors of WRS<jats:sub>65dB<\/jats:sub> were identified using Spearman correlation analysis (\u03c1). The mean postoperative WRS<jats:sub>65dB<\/jats:sub> was 81.5% (SD\u2009=\u20099.0%). The strongest correlations were observed with age (\u03c1 = \u2212\u20090.63) and two surrogate parameters of cochlear reserve - WRS<jats:sub>max<\/jats:sub> (\u03c1\u2009=\u20090.56) and postoperative BC<jats:sub>PTA4<\/jats:sub> (\u03c1 = \u2212\u20090.52). PROMs confirmed high subjective benefit and displayed correlations with audiological outcomes. Age, WRS<jats:sub>max<\/jats:sub> and postoperative BC<jats:sub>PTA4<\/jats:sub> will serve as the basis for the AI-based prediction model presented in part II. The correlation of PROMs with audiological outcomes highlights the importance of integrating objective and subjective measures in hearing rehabilitation.<\/jats:p>","DOI":"10.1038\/s41598-025-20966-y","type":"journal-article","created":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T09:08:57Z","timestamp":1760087337000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Comprehensive analysis of predictors and outcomes following Vibrant Soundbridge implantation \u2013 part 1 of a prospective study"],"prefix":"10.1038","volume":"15","author":[{"given":"Christoph","family":"M\u00fcller","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hannes","family":"Seidler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Anna","family":"Tsypina","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Janina","family":"Kuch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Zahnert","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Susen","family":"Lailach","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,10,10]]},"reference":[{"key":"20966_CR1","doi-asserted-by":"publisher","unstructured":"Rahne, T. & Plontke, S. K. Systematic and audiological indication criteria for bone conduction devices and active middle ear implants. Hear. Res. 108424 https:\/\/doi.org\/10.1016\/j.heares.2021.108424 (2022).","DOI":"10.1016\/j.heares.2021.108424"},{"key":"20966_CR2","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1159\/000453354","volume":"21","author":"S Busch","year":"2016","unstructured":"Busch, S., Lenarz, T. & Maier, H. Comparison of alternative coupling methods of the vibrant Soundbridge floating mass transducer. Audiol. Neurotol. 21, 347\u2013355 (2016).","journal-title":"Audiol. Neurotol"},{"key":"20966_CR3","first-page":"38","volume":"69","author":"WD Baumgartner","year":"2010","unstructured":"Baumgartner, W. D. et al. The vibrant Soundbridge for conductive and mixed hearing losses: European multicenter study results. Adv. Otorhinolaryngol. 69, 38\u201350 (2010).","journal-title":"Adv. Otorhinolaryngol."},{"key":"20966_CR4","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1097\/MAO.0000000000002418","volume":"41","author":"JL Spiegel","year":"2020","unstructured":"Spiegel, J. L. et al. Long-term stability and functional outcome of an active middle ear implant regarding different coupling sites. Otol Neurotol. 41, 60\u201367 (2020).","journal-title":"Otol Neurotol"},{"key":"20966_CR5","doi-asserted-by":"publisher","first-page":"391","DOI":"10.3109\/14992027.2014.986690","volume":"54","author":"H Mojallal","year":"2015","unstructured":"Mojallal, H., Schwab, B., Hinze, A. L., Giere, T. & Lenarz, T. Retrospective audiological analysis of bone conduction versus round window vibratory stimulation in patients with mixed hearing loss. Int. J. Audiol. 54, 391\u2013400 (2015).","journal-title":"Int. J. Audiol."},{"key":"20966_CR6","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1097\/MAO.0000000000001412","volume":"38","author":"A M\u00fcller","year":"2017","unstructured":"M\u00fcller, A. et al. Influence of floating-mass transducer coupling efficiency for active middle-ear implants on speech recognition. Otol Neurotol. 38, 809\u2013814 (2017).","journal-title":"Otol Neurotol"},{"key":"20966_CR7","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1097\/AUD.0000000000001258","volume":"44","author":"C M\u00fcller","year":"2023","unstructured":"M\u00fcller, C. et al. Influence of the coupling on the hearing outcome after implantation of an active middle ear implant: comparison of the transmission behavior in Temporal bone experiments with clinical data. Ear Hear. 44, 135\u2013145 (2023).","journal-title":"Ear Hear."},{"key":"20966_CR8","doi-asserted-by":"publisher","first-page":"e906","DOI":"10.1097\/MAO.0000000000002484","volume":"41","author":"L Fr\u00f6hlich","year":"2020","unstructured":"Fr\u00f6hlich, L., Plontke, S. K. & Rahne, T. A quantitative approach for the objective assessment of coupling efficiency for an active middle ear implant by recording auditory steady-state responses. Otology Neurotology. 41, e906\u2013e911 (2020).","journal-title":"Otology Neurotology"},{"key":"20966_CR9","doi-asserted-by":"publisher","first-page":"105","DOI":"10.1159\/000490878","volume":"23","author":"H Maier","year":"2018","unstructured":"Maier, H. et al. Minimal reporting standards for active middle ear hearing implants. Audiol. Neurootol. 23, 105\u2013115 (2018).","journal-title":"Audiol. Neurootol"},{"key":"20966_CR10","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1177\/108471380300700302","volume":"7","author":"F Kuk","year":"2003","unstructured":"Kuk, F. & Ludvigsen, C. Reconsidering the concept of the aided threshold for nonlinear hearing AIDS. Trends Amplif. 7, 77\u201397 (2003).","journal-title":"Trends Amplif."},{"key":"20966_CR11","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1007\/s00106-020-00873-6","volume":"69","author":"H Maier","year":"2021","unstructured":"Maier, H. Audiologische zielparameter Bei klinischen studien Mit implantierbaren h\u00f6rsystemen. HNO 69, 483\u2013490 (2021).","journal-title":"HNO"},{"key":"20966_CR12","doi-asserted-by":"publisher","first-page":"e912","DOI":"10.1097\/MAO.0000000000002797","volume":"41","author":"N Lasurashvili","year":"2020","unstructured":"Lasurashvili, N. et al. Fully implantable active middle ear implants after subtotal petrosectomy with fat obliteration: preliminary clinical results. Otology Neurotology. 41, e912\u2013e920 (2020).","journal-title":"Otology Neurotology"},{"key":"20966_CR13","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1177\/108471380200600302","volume":"6","author":"AM Amlani","year":"2002","unstructured":"Amlani, A. M., Punch, J. L. & Ching, T. Y. C. Methods and applications of the audibility index in hearing aid selection and fitting. Trends Amplif. 6, 81\u2013129 (2002).","journal-title":"Trends Amplif."},{"key":"20966_CR14","first-page":"316","volume":"23","author":"T Zahnert","year":"2018","unstructured":"Zahnert, T. et al. Long-term outcomes of vibroplasty coupler implantations to treat mixed\/conductive hearing loss. AUD 23, 316\u2013325 (2018).","journal-title":"AUD"},{"key":"20966_CR15","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1097\/MAO.0000000000000943","volume":"37","author":"SP Schraven","year":"2016","unstructured":"Schraven, S. P. et al. Long-term stability of the active middle-ear implant with floating-mass transducer technology: a single-center study. Otol Neurotol. 37, 252\u2013266 (2016).","journal-title":"Otol Neurotol"},{"key":"20966_CR16","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1007\/s00405-020-06064-x","volume":"278","author":"T Rahne","year":"2021","unstructured":"Rahne, T. et al. A retrospective European multicenter analysis of the functional outcomes after active middle ear implant surgery using the third generation vibroplasty couplers. Eur. Arch. Otorhinolaryngol. 278, 67\u201375 (2021).","journal-title":"Eur. Arch. Otorhinolaryngol."},{"key":"20966_CR17","doi-asserted-by":"publisher","first-page":"E940","DOI":"10.1002\/lary.28771","volume":"131","author":"U Hoppe","year":"2021","unstructured":"Hoppe, U., Hocke, T., Hast, A. & Iro, H. Cochlear implantation in candidates with moderate-to-severe hearing loss and poor speech perception. Laryngoscope 131, E940\u2013E945 (2021).","journal-title":"Laryngoscope"},{"key":"20966_CR18","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1007\/s00106-019-0648-0","volume":"67","author":"U Hoppe","year":"2019","unstructured":"Hoppe, U., Hocke, T., Hast, A. & Iro, H. Maximum preimplantation monosyllabic score as predictor of cochlear implant outcome. HNO 67, 62\u201368 (2019).","journal-title":"HNO"},{"key":"20966_CR19","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1016\/j.heares.2012.12.010","volume":"301","author":"H Maier","year":"2013","unstructured":"Maier, H., Salcher, R., Schwab, B. & Lenarz, T. The effect of static force on round window stimulation with the direct acoustic cochlea stimulator. Hear. Res. 301, 115\u2013124 (2013).","journal-title":"Hear. Res."},{"key":"20966_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.heares.2014.04.001","volume":"314","author":"R Salcher","year":"2014","unstructured":"Salcher, R., Schwab, B., Lenarz, T. & Maier, H. Round window stimulation with the floating mass transducer at constant pretension. Hear. Res. 314, 1\u20139 (2014).","journal-title":"Hear. Res."},{"key":"20966_CR21","doi-asserted-by":"publisher","first-page":"538","DOI":"10.1111\/coa.13017","volume":"43","author":"AO Gostian","year":"2018","unstructured":"Gostian, A. O. et al. Influence of backside loading on the floating mass transducer: an in vitro experimental study. Clin. Otolaryngol. 43, 538\u2013543 (2018).","journal-title":"Clin. Otolaryngol."},{"key":"20966_CR22","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000000655","author":"AO Gostian","year":"2014","unstructured":"Gostian, A. O. et al. Impact of coupling techniques of an active middle ear device to the round window membrane for the backward stimulation of the cochlea. Otol Neurotol. https:\/\/doi.org\/10.1097\/MAO.0000000000000655 (2014).","journal-title":"Otol Neurotol"},{"key":"20966_CR23","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1044\/2022_AJA-21-00208","volume":"31","author":"M Cebulla","year":"2022","unstructured":"Cebulla, M., Herrmann, D. P., Hagen, R. & Rak, K. Intraoperative auditory brainstem response measurements via the vibrant Soundbridge active middle ear implant: comparison of two methods. Am. J. Audiol. 31, 261\u2013267 (2022).","journal-title":"Am. J. Audiol."},{"key":"20966_CR24","doi-asserted-by":"publisher","DOI":"10.1097\/MAO.0000000000003491","author":"H Maier","year":"2022","unstructured":"Maier, H. et al. Consensus statement on bone conduction devices and active middle ear implants in conductive and mixed hearing loss. Otology Neurotology. https:\/\/doi.org\/10.1097\/MAO.0000000000003491 (2022).","journal-title":"Otology Neurotology"},{"key":"20966_CR25","doi-asserted-by":"crossref","first-page":"S3","DOI":"10.1055\/a-1647-8616","volume":"101","author":"S Lailach","year":"2022","unstructured":"Lailach, S. & Zahnert, T. Results and quality of life after implantation of active middle ear implants. Laryngorhinootologie 101, S3\u2013S35 (2022).","journal-title":"Laryngorhinootologie"},{"key":"20966_CR26","doi-asserted-by":"publisher","first-page":"30","DOI":"10.3109\/14992020209101309","volume":"41","author":"RM Cox","year":"2002","unstructured":"Cox, R. M. & Alexander, G. C. The international outcome inventory for hearing aids (IOI-HA): psychometric properties of the English version: El inventario international de resultados Para auxiliares auditivos (IOI-HA): propiedades Psicometricas de La version En ingles. Int. J. Audiol. 41, 30\u201335 (2002).","journal-title":"Int. J. Audiol."},{"key":"20966_CR27","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1007\/s00405-013-2387-2","volume":"271","author":"A Atas","year":"2014","unstructured":"Atas, A., Tutar, H., Gunduz, B. & Bayaz\u0131t, Y. A. Vibrant sound Bridge application to middle ear windows versus conventional hearing aids: a comparative study based on international outcome inventory for hearing aids. Eur. Arch. Otorhinolaryngol. 271, 35\u201340 (2014).","journal-title":"Eur. Arch. Otorhinolaryngol."},{"key":"20966_CR28","doi-asserted-by":"publisher","first-page":"81","DOI":"10.3766\/jaaa.23.2.2","volume":"23","author":"J Banh","year":"2012","unstructured":"Banh, J., Singh, G. & Pichora-Fuller, M. K. Age affects responses on the speech, spatial, and qualities of hearing scale (SSQ) by adults with minimal audiometric loss. j. am. acad. audiol. 23, 81\u201391 (2012).","journal-title":"j. am. acad. audiol."},{"key":"20966_CR29","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1080\/14992020400050014","volume":"43","author":"S Gatehouse","year":"2004","unstructured":"Gatehouse, S. & Noble, W. The speech, Spatial and qualities of hearing scale (SSQ). Int. J. Audiol. 43, 85\u201399 (2004).","journal-title":"Int. J. Audiol."},{"key":"20966_CR30","doi-asserted-by":"publisher","first-page":"322","DOI":"10.14639\/0392-100X-N2659","volume":"44","author":"Y Liu","year":"2024","unstructured":"Liu, Y. et al. Long-term safety and subjective satisfaction of Bonebridge and vibrant Soundbridge in congenital unilateral conductive hearing loss. Acta Otorhinolaryngol. Ital. 44, 322 (2024).","journal-title":"Acta Otorhinolaryngol. Ital."},{"key":"20966_CR31","doi-asserted-by":"publisher","first-page":"2387","DOI":"10.1007\/s00405-022-07741-9","volume":"280","author":"A Ratuszniak","year":"2023","unstructured":"Ratuszniak, A. et al. New technology can benefit established middle ear implant users: Samba 2 vs previous models of audio processors for vibrant Soundbridge. Eur. Arch. Otorhinolaryngol. 280, 2387\u20132396 (2023).","journal-title":"Eur. Arch. Otorhinolaryngol."},{"key":"20966_CR32","doi-asserted-by":"publisher","first-page":"6215","DOI":"10.3390\/jcm12196215","volume":"12","author":"U Hoppe","year":"2023","unstructured":"Hoppe, U., Hast, A., Hornung, J. & Hocke, T. Evolving a model for cochlear implant outcome. J. Clin. Med. 12, 6215 (2023).","journal-title":"J. Clin. Med."},{"key":"20966_CR33","doi-asserted-by":"publisher","first-page":"409","DOI":"10.3109\/14992027.2013.781278","volume":"52","author":"W Noble","year":"2013","unstructured":"Noble, W., Jensen, N. S., Naylor, G., Bhullar, N. & Akeroyd, M. A. A short form of the speech, Spatial and qualities of hearing scale suitable for clinical use: the SSQ12. Int. J. Audiol. 52, 409\u2013412 (2013).","journal-title":"Int. J. Audiol."},{"key":"20966_CR34","doi-asserted-by":"crossref","unstructured":"Cohen, J. Statistical Power Analysis for the Behavioral Sciences (routledge, 2013).","DOI":"10.4324\/9780203771587"},{"key":"20966_CR35","doi-asserted-by":"publisher","first-page":"100S","DOI":"10.1097\/AUD.0b013e31803150f4","volume":"28","author":"N Cohen","year":"2007","unstructured":"Cohen, N. The totally implantable cochlea implant. Ear Hear. 28, 100S\u2013101S (2007).","journal-title":"Ear Hear."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-20966-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-20966-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-20966-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T09:09:00Z","timestamp":1760087340000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-20966-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,10]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["20966"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-20966-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,10]]},"assertion":[{"value":"4 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 October 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"The study followed the review and approval of the local ethics committee at the Technische Universit\u00e4t Dresden (BO-EK-51012023). Informed consent was obtained from all subjects and\/or their legal guardian(s) prior to participation in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Approval of local ethics committee and informed consent"}}],"article-number":"35403"}}