{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T15:07:19Z","timestamp":1780067239520,"version":"3.54.0"},"reference-count":29,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T00:00:00Z","timestamp":1762300800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T00:00:00Z","timestamp":1762300800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/100014985","name":"European Society of Radiology","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100014985","id-type":"DOI","asserted-by":"publisher"}]},{"name":"European Institute for Biomedical Imaging Research"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-025-22660-5","type":"journal-article","created":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T13:37:40Z","timestamp":1762349860000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Longitudinal assessment of renal allograft function in donors and pediatric recipients by arterial spin labeling MRI perfusion quantification"],"prefix":"10.1038","volume":"15","author":[{"given":"Tijana","family":"Radovic","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brankica","family":"Spasojevic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mirjana","family":"Cvetkovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gordana","family":"Milosevski-Lomic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Milica M.","family":"Jankovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ivana","family":"Gojkovic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Polina","family":"Pavicevic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,11,5]]},"reference":[{"key":"22660_CR1","first-page":"37","volume":"37","author":"K Landreneau","year":"2010","unstructured":"Landreneau, K., Lee, K. & Landreneau, M. D. Quality of life in patients undergoing hemodialysis and renal transplantation\u2014a meta-analytic review. Nephrol. Nurs. J. 37, 37\u201344 (2010).","journal-title":"Nephrol. Nurs. J."},{"issue":"9","key":"22660_CR2","doi-asserted-by":"publisher","first-page":"e256","DOI":"10.1097\/TP.0000000000004977","volume":"108","author":"S Hariharan","year":"2024","unstructured":"Hariharan, S. et al. Long-term kidney transplant survival across the globe. Transplantation 108(9):e254\u2013e263 (2024). https:\/\/doi.org\/10.1097\/TP.0000000000004977","journal-title":"Transplantation"},{"issue":"4","key":"22660_CR3","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1007\/BF00182077","volume":"14","author":"C Modlin","year":"2020","unstructured":"Modlin, C., Goldfarb, D. & Novick, A. C. Hyperfiltration nephropathy as a cause of late graft loss in renal transplantation. World J. Urol. 14(4):256\u2013264. https:\/\/doi.org\/10.1007\/BF00182077 (1996).","journal-title":"World J. Urol."},{"issue":"6","key":"22660_CR4","doi-asserted-by":"publisher","first-page":"1774","DOI":"10.1038\/ki.1996.265","volume":"49","author":"BM Brenner","year":"1996","unstructured":"Brenner, B. M., Lawler, E. V. & Mackenzie, H. S. The hyperfiltration theory: A paradigm shift in nephrology. Kidney Int. 49(6), 1774\u20131777. https:\/\/doi.org\/10.1038\/ki.1996.265 (1996).","journal-title":"Kidney Int."},{"key":"22660_CR5","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1007\/s10334-019-00800-z","volume":"33","author":"F Nery","year":"2020","unstructured":"Nery, F. et al. Consensus-based technical recommendations for clinical translation of renal ASL MRI. Magn. Reson. Mater. Phys., Biol. Med. 33, 141\u2013161 (2020).","journal-title":"Magn. Reson. Mater. Phys., Biol. Med."},{"key":"22660_CR6","doi-asserted-by":"publisher","first-page":"2","DOI":"10.3390\/diagnostics8010002","volume":"8","author":"F Nery","year":"2018","unstructured":"Nery, F., Gordon, I. & Thomas, D. L. Non-Invasive renal perfusion imaging using arterial spin labeling MRI: Challenges and opportunities. Diagnostics 8, 2. https:\/\/doi.org\/10.3390\/diagnostics8010002 (2018).","journal-title":"Diagnostics"},{"issue":"suppl_2","key":"22660_CR7","doi-asserted-by":"publisher","first-page":"ii15","DOI":"10.1093\/ndt\/gfy180","volume":"33","author":"A Odudu","year":"2018","unstructured":"Odudu, A. et al. Arterial spin labelling MRI to measure renal perfusion: A systematic review and statement paper. Nephrol. Dial Transpl. 33(suppl_2), ii15\u2013ii21. https:\/\/doi.org\/10.1093\/ndt\/gfy180 (2018).","journal-title":"Nephrol. Dial Transpl."},{"issue":"5","key":"22660_CR8","doi-asserted-by":"publisher","first-page":"2687","DOI":"10.1007\/s00330-020-07369-5","volume":"31","author":"W Wang","year":"2021","unstructured":"Wang, W. et al. Early detection of subclinical pathology in patients with stable kidney graft function by arterial spin labeling. Eur. Radiol. 31(5), 2687\u20132695. https:\/\/doi.org\/10.1007\/s00330-020-07369-5 (2021).","journal-title":"Eur. Radiol."},{"issue":"1","key":"22660_CR9","doi-asserted-by":"publisher","first-page":"276","DOI":"10.1002\/mrm.27723","volume":"82","author":"IK Bones","year":"2019","unstructured":"Bones, I. K. et al. Enabling free-breathing background suppressed renal pCASL using fat imaging and retrospective motion correction. Magn. Reson. Med. 82(1), 276\u2013288. https:\/\/doi.org\/10.1002\/mrm.27723 (2019).","journal-title":"Magn. Reson. Med."},{"issue":"2","key":"22660_CR10","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1097\/RLI.0000000000000210","volume":"51","author":"DJ Niles","year":"2016","unstructured":"Niles, D. J. et al. Longitudinal assessment of renal perfusion and oxygenation in transplant donor\u2013recipient pairs using arterial spin labeling and blood oxygen level-dependent magnetic resonance imaging. Invest. Radiol. 51(2), 113\u2013120 (2016).","journal-title":"Invest. Radiol."},{"issue":"4","key":"22660_CR11","doi-asserted-by":"publisher","first-page":"247","DOI":"10.7326\/0003-4819-145-4-200608150-00004","volume":"145","author":"AS Levey","year":"2006","unstructured":"Levey, A. S. et al. Using standardized serum creatinine values in the modification of diet in renal disease study equation for estimating glomerular filtration rate. Ann. Intern. Med. 145(4), 247\u2013254. https:\/\/doi.org\/10.7326\/0003-4819-145-4-200608150-00004 (2006).","journal-title":"Ann. Intern. Med."},{"issue":"3","key":"22660_CR12","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1681\/ASN.2008030287","volume":"20","author":"G Schwartz","year":"2020","unstructured":"Schwartz, G. J. et al. New equations to estimate GFR in children with CKD. J. Am. Soc. Nephrol. 20(3), 629\u2013637. https:\/\/doi.org\/10.1681\/ASN.2008030287 (2009).","journal-title":"J. Am. Soc. Nephrol."},{"key":"22660_CR13","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1007\/s10334-019-00806-7","volume":"33","author":"AA Harteveld","year":"2020","unstructured":"Harteveld, A. A. et al. Comparison of multi\u2013delay FAIR and pCASL labeling approaches for renal perfusion quantification at 3T MRI. Magn. Reson. Mater. Phys. Biol. Med. 33, 81\u201394 (2020).","journal-title":"Magn. Reson. Mater. Phys. Biol. Med."},{"key":"22660_CR14","doi-asserted-by":"publisher","first-page":"353","DOI":"10.1002\/mrm.10709","volume":"51","author":"P Marirosian","year":"2004","unstructured":"Marirosian, P., Klose, U., Mader, I. & Schick, F. FAIR true-FISP perfusion imaging of the kidneys. Magn. Reson. Med. 51, 353\u2013361 (2004).","journal-title":"Magn. Reson. Med."},{"key":"22660_CR15","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1007\/s10334-011-0286-3","volume":"25","author":"N Maleki","year":"2012","unstructured":"Maleki, N., Dai, W. & Alsop, D. C. Optimization of background suppression for arterial spin labelling perfusion imaging. Magn. Reson. Mater. Phys. 25, 127\u2013133 (2012).","journal-title":"Magn. Reson. Mater. Phys."},{"key":"22660_CR16","doi-asserted-by":"publisher","first-page":"702","DOI":"10.1002\/mrm.1910390506","volume":"39","author":"EC Wong","year":"1998","unstructured":"Wong, E. C., Buxton, R. B. & Frank, L. R. Quantitative imaging of perfusion using a single Subtraction (QUIPSS and QUIPSS II). Magn. Reson. Med. 39, 702\u2013708 (1998).","journal-title":"Magn. Reson. Med."},{"key":"22660_CR17","doi-asserted-by":"publisher","first-page":"570","DOI":"10.1002\/mrm.24692","volume":"71","author":"H Tan","year":"2014","unstructured":"Tan, H., Koktzoglou, I. & Prasad, P. V. Renal perfusion imaging with two-dimensional navigator gated arterial spin labeling. Magn. Reson. Med. 71, 570\u2013579 (2014).","journal-title":"Magn. Reson. Med."},{"key":"22660_CR18","unstructured":"Barrett, K. E., Brooks, H. L., Boitano, S. & Barman, S. M. Ganong\u2019s Review of Medical Physiology, 23rd ed, 643\u2013644. (McGraw-Hill Medical, 2010)."},{"issue":"5","key":"22660_CR19","doi-asserted-by":"publisher","first-page":"1777","DOI":"10.1002\/jmri.28926","volume":"59","author":"W Wang","year":"2024","unstructured":"Wang, W. et al. Significance of arterial spin labeling for reducing biopsies in patients with kidney allograft dysfunction. J. Magn. Reson. Imaging 59(5), 1777\u20131784. https:\/\/doi.org\/10.1002\/jmri.28926 (2024).","journal-title":"J. Magn. Reson. Imaging"},{"issue":"3","key":"22660_CR20","doi-asserted-by":"publisher","first-page":"2415","DOI":"10.21037\/qims-23-1577","volume":"14","author":"B Jiang","year":"2024","unstructured":"Jiang, B. et al. Arterial spin labeling combined with T1 mapping for assessment of kidney function and histopathology in patients with long-term renal transplant survival after kidney transplantation. Quant. Imaging Med. Surg. 14(3), 2415\u20132425. https:\/\/doi.org\/10.21037\/qims-23-1577 (2024).","journal-title":"Quant. Imaging Med. Surg."},{"issue":"1","key":"22660_CR21","doi-asserted-by":"publisher","first-page":"828","DOI":"10.1038\/s41598-022-04794-y","volume":"12","author":"T Radovic","year":"2022","unstructured":"Radovic, T. et al. Detection of impaired renal allograft function in paediatric and young adult patients using arterial spin labelling MRI (ASL-MRI). Sci. Rep. 12(1), 828. https:\/\/doi.org\/10.1038\/s41598-022-04794-y (2022).","journal-title":"Sci. Rep."},{"issue":"7","key":"22660_CR22","doi-asserted-by":"publisher","first-page":"908","DOI":"10.1016\/j.mri.2016.04.022","volume":"34","author":"T Ren","year":"2016","unstructured":"Ren, T. et al. Evaluation of renal allografts function early after transplantation using intravoxel incoherent motion and arterial spin labeling MRI. Magn. Reson. Imaging. 34 (7), 908\u2013914. https:\/\/doi.org\/10.1016\/j.mri.2016.04.022 (2016).","journal-title":"Magn. Reson. Imaging"},{"issue":"8","key":"22660_CR23","doi-asserted-by":"publisher","first-page":"2390","DOI":"10.1007\/s00330-015-3594-6","volume":"25","author":"M Cutajar","year":"2015","unstructured":"Cutajar, M. et al. Renal blood flow using arterial spin labelling MRI and calculated filtration fraction in healthy adult kidney donors pre-nephrectomy and post-nephrectomy. Eur. Radiol. 25(8), 2390\u20132396. https:\/\/doi.org\/10.1007\/s00330-015-3594-6 (2015).","journal-title":"Eur. Radiol."},{"key":"22660_CR24","first-page":"851","volume-title":"Renal Radionuclides and in Vitro Quantitation","author":"MG Campbell","year":"2003","unstructured":"Campbell, M. G. & Powers, T. A. Diagnostic nuclear medicine. In Renal Radionuclides and in Vitro Quantitation (eds Sandler, M. P., Coleman, R. E., Patton, J. A., Wackers, F. J. T. & Gottschalk, A.), 851\u2013864 (Lippincott Williams & Wilkins, Philadelphia, 2003)."},{"key":"22660_CR25","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1186\/1471-2369-15-23","volume":"15","author":"KA Gillis","year":"2014","unstructured":"Gillis, K. A. et al. Inter-study reproducibility of arterial spin labelling magnetic resonance imaging for measurement of renal perfusion in healthy volunteers at 3 Tesla. BMC Nephrol. 15, 23 (2014).","journal-title":"BMC Nephrol."},{"issue":"7","key":"22660_CR26","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.mri.2010.07.018","volume":"29","author":"NS Artz","year":"2011","unstructured":"Artz, N. S. et al. Arterial spin labeling MRI for assessment of perfusion in native and transplanted kidneys. Magn. Reson. Imaging 29(7), 74\u201382 (2011).","journal-title":"Magn. Reson. Imaging"},{"key":"22660_CR27","doi-asserted-by":"publisher","first-page":"1320","DOI":"10.1007\/s00330-012-2382-9","volume":"22","author":"PS Tofts","year":"2012","unstructured":"Tofts, P. S., Cutajar, M., Mendichovszky, I. A., Peters, A. M. & Gordon, I. Precise measurement of renal filtration and vascular parameters using a two-compartment model for dynamic contrast-enhanced MRI of the kidney gives realistic normal values. Eur. Radiol. 22, 1320\u20131330 (2012).","journal-title":"Eur. Radiol."},{"issue":"6","key":"22660_CR28","doi-asserted-by":"publisher","first-page":"1300","DOI":"10.1007\/s00330-014-3130-0","volume":"24","author":"M Cutajar","year":"2014","unstructured":"Cutajar, M. et al. Comparison of ASL and DCE MRI for the non-invasive measurement of renal blood flow: Quantification and reproducibility. Eur. Radiol. 24(6), 1300\u20131308. https:\/\/doi.org\/10.1007\/s00330-014-3130-0 (2014).","journal-title":"Eur. Radiol."},{"key":"22660_CR29","unstructured":"Feinberg, D. A. & G\u00fcnther, M. Cerebral blood flow imaging with 3D GRASE ASL sequence increases SNR and shortens acquisition time. In MAGNETOM Flash, Vol. 3 62\u201369 (2009)."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-22660-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-22660-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-22660-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T13:37:42Z","timestamp":1762349862000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-22660-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,5]]},"references-count":29,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["22660"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-22660-5","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,5]]},"assertion":[{"value":"23 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 September 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"All procedures performed in the study involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and the 1964 Helsinki declaration and its later amendments or comparable ethical standards. This prospective study was approved by the University Children\u2019s Hospital Ethics Committee (reference number 16\/238\/08\/10\/2024).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"All of the authors have approved the content of this paper and have agreed to the Scientific Reports\u2019 submission policies as well as the responsible authorities at the institute where the research has been carried out.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Written informed consent was obtained from all participants and their guardians if necessary.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}}],"article-number":"38809"}}