{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T13:52:32Z","timestamp":1781617952775,"version":"3.54.5"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T00:00:00Z","timestamp":1762992000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T00:00:00Z","timestamp":1762992000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>This study aimed to evaluate the anatomic feasibility of a novel off-the-shelf device (modular endograft with superior mesenteric artery fenestration, celiac scallop, and bilateral renal inner branches) designed for the treatment of juxtarenal and pararenal abdominal aortic aneurysms (AAAs). Digital computed tomography angiograms were analyzed from 170 consecutive patients with juxtarenal or pararenal AAAs who participated in imaging screening for a national multicenter clinical trial assessing the effectiveness of the WeFlow-JAAA system between February 2022 and January 2024. Anatomic feasibility was evaluated in accordance with the investigational protocols and the instructions for use. A proximal seal of \u2265\u200920\u00a0mm was achieved in 98.2% of patients, and renovisceral artery incorporation was observed in 73.5% (125\/170) of cases. According to the conservative instructions for use (IFU) criteria, anatomic feasibility was achieved in 34.7% (95%CI: 27.5%~41.9%) of patients. When applying the liberal IFU criteria, the suitability rate increased to 64.1% (95%CI: 56.8%~71.4%), with configurations A and B being suitable for 56.5% and 60.6% of cases, respectively. The WeFlow-JAAA endograft system exhibits a suitability rate of 64.1% for treating JRAAAs and PRAAAs with a healthy sealing zone of at least 5\u00a0mm below the SMA within the Chinese population. Nevertheless, the current design does not optimally allow for the incorporation of renovisceral arteries, indicating a need for further technical research in this domain.<\/jats:p>","DOI":"10.1038\/s41598-025-23485-y","type":"journal-article","created":{"date-parts":[[2025,11,13]],"date-time":"2025-11-13T22:41:09Z","timestamp":1763073669000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Anatomic feasibility of the WeFlow-JAAA endograft system for treating juxtarenal and pararenal abdominal aortic aneurysms"],"prefix":"10.1038","volume":"15","author":[{"given":"Jiang-Ping","family":"Gao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chun-An-Sheng","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hong-Peng","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li-Jun","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,11,13]]},"reference":[{"key":"23485_CR1","doi-asserted-by":"publisher","first-page":"2848","DOI":"10.1161\/CIRCULATIONAHA.110.014902","volume":"123","author":"A Schanzer","year":"2011","unstructured":"Schanzer, A. et al. Predictors of abdominal aortic aneurysm sac enlargement after endovascular repair. Circulation 123, 2848\u20132855 (2011).","journal-title":"Circulation"},{"key":"23485_CR2","doi-asserted-by":"publisher","first-page":"2482","DOI":"10.1016\/S0140-6736(17)30639-6","volume":"389","author":"P Ulug","year":"2017","unstructured":"Ulug, P., Sweeting, M. J., von Allmen, R. S., Thompson, S. G. & Powell, J. T. Morphological suitability for endovascular repair, non-intervention rates, and operative mortality in women and men assessed for intact abdominal aortic aneurysm repair: systematic reviews with meta-analysis. Lancet 389, 2482\u20132491 (2017).","journal-title":"Lancet"},{"key":"23485_CR3","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/j.jvs.2010.12.010","volume":"54","author":"AF Aburahma","year":"2011","unstructured":"Aburahma, A. F. et al. Clinical outcomes for hostile versus favorable aortic neck anatomy in endovascular aortic aneurysm repair using modular devices. J. Vasc Surg. 54, 13\u201321 (2011).","journal-title":"J. Vasc Surg."},{"key":"23485_CR4","doi-asserted-by":"crossref","unstructured":"Wanhainen, A. et al. (eds) \u2018s Choice - European Society for Vascular Surgery (ESVS) 2019 clinical practice guidelines on the management of abdominal aorto-iliac artery aneurysms. Eur. J. Vasc. Endovasc. Surg. 57, 8\u201393 (2019).","DOI":"10.1016\/j.ejvs.2020.09.004"},{"key":"23485_CR5","doi-asserted-by":"publisher","first-page":"e334","DOI":"10.1161\/CIR.0000000000001106","volume":"146","author":"EM Isselbacher","year":"2022","unstructured":"Isselbacher, E. M. et al. 2022 ACC\/AHA guideline for the diagnosis and management of aortic disease: a report of the American heart Association\/American college of cardiology joint committee on clinical practice guidelines. Circulation 146, e334\u2013e482 (2022).","journal-title":"Circulation"},{"key":"23485_CR6","doi-asserted-by":"publisher","first-page":"1673","DOI":"10.1016\/j.jvs.2017.10.055","volume":"67","author":"SS Dossabhoy","year":"2018","unstructured":"Dossabhoy, S. S. et al. Fenestrated endovascular aortic aneurysm repair using physician-modified endovascular grafts versus company-manufactured devices. J. Vasc Surg. 67, 1673\u20131683 (2018).","journal-title":"J. Vasc Surg."},{"key":"23485_CR7","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1016\/j.jvs.2018.09.063","volume":"70","author":"GS Oderich","year":"2019","unstructured":"Oderich, G. S. et al. Evolution from physician-modified to company-manufactured fenestrated-branched endografts to treat pararenal and thoracoabdominal aortic aneurysms. J. Vasc Surg. 70, 31\u201342e37 (2019).","journal-title":"J. Vasc Surg."},{"key":"23485_CR8","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1016\/j.jvs.2019.08.273","volume":"72","author":"E Gallitto","year":"2020","unstructured":"Gallitto, E. et al. The risk of aneurysm rupture and target visceral vessel occlusion during the lead period of custom-made fenestrated\/branched endograft. J. Vasc Surg. 72, 16\u201324 (2020).","journal-title":"J. Vasc Surg."},{"key":"23485_CR9","doi-asserted-by":"publisher","first-page":"839","DOI":"10.1016\/j.jvs.2014.04.038","volume":"60","author":"BC Mendes","year":"2014","unstructured":"Mendes, B. C. et al. Anatomic feasibility of off-the-shelf fenestrated stent grafts to treat juxtarenal and pararenal abdominal aortic aneurysms. J. Vasc Surg. 60, 839\u2013847 (2014). discussion 847\u2009\u2013\u2009838.","journal-title":"J. Vasc Surg."},{"key":"23485_CR10","doi-asserted-by":"publisher","first-page":"1409","DOI":"10.1016\/j.jvs.2019.03.026","volume":"70","author":"MA Farber","year":"2019","unstructured":"Farber, M. A., Oderich, G. S., Timaran, C., Sanchez, L. A. & Dawson, Z. Results from a prospective multicenter feasibility study of zenith p-branch stent graft. J. Vasc Surg. 70, 1409\u20131418e1403 (2019).","journal-title":"J. Vasc Surg."},{"key":"23485_CR11","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1016\/j.avsg.2023.03.017","volume":"96","author":"VC Gomes","year":"2023","unstructured":"Gomes, V. C. et al. Outcome analysis comparing asymptomatic juxtarenal aortic aneurysms treated with Custom-Manufactured Fenestrated-Branched devices and the Off-The-Shelf zenith p-Branch device. Ann. Vasc Surg. 96, 207\u2013214 (2023).","journal-title":"Ann. Vasc Surg."},{"key":"23485_CR12","doi-asserted-by":"crossref","unstructured":"Gao, J. P. et al. First-in-Human Clinical Trial of the WeFlow-JAAA Endograft System in Patients With Juxtarenal Abdominal Aortic Aneurysms. J Endovasc Ther. 32, 1526\u20131537 (2025)","DOI":"10.1177\/15266028231210480"},{"key":"23485_CR13","doi-asserted-by":"publisher","first-page":"1013834","DOI":"10.3389\/fcvm.2022.1013834","volume":"9","author":"JP Gao","year":"2022","unstructured":"Gao, J. P. et al. A prospective, multicenter, single-arm clinical trial cohort to evaluate the safety and effectiveness of a novel stent graft system (WeFlow-JAAA) for the treatment of juxtarenal abdominal aortic aneurysm: a study protocol. Front. Cardiovasc. Med. 9, 1013834 (2022).","journal-title":"Front. Cardiovasc. Med."},{"key":"23485_CR14","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.avsg.2025.06.007","volume":"122","author":"C Wang","year":"2025","unstructured":"Wang, C. et al. Early outcome of WeFlow-JAAA off-the-shelf endograft in the treatment of Juxtarenal\/Pararenal abdominal aortic aneurysms. Ann. Vasc Surg. 122, 187\u2013193 (2025).","journal-title":"Ann. Vasc Surg."},{"key":"23485_CR15","doi-asserted-by":"publisher","first-page":"4s","DOI":"10.1016\/j.jvs.2020.06.011","volume":"73","author":"GS Oderich","year":"2021","unstructured":"Oderich, G. S. et al. Reporting standards for endovascular aortic repair of aneurysms involving the renal-mesenteric arteries. J. Vasc Surg. 73, 4s\u201352s (2021).","journal-title":"J. Vasc Surg."},{"key":"23485_CR16","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1016\/j.jvs.2011.12.062","volume":"56","author":"F Bastos Gon\u00e7alves","year":"2012","unstructured":"Bastos Gon\u00e7alves, F. et al. The influence of neck thrombus on clinical outcome and aneurysm morphology after endovascular aneurysm repair. J. Vasc Surg. 56, 36\u201344 (2012).","journal-title":"J. Vasc Surg."},{"key":"23485_CR17","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1583\/11-3772.1","volume":"19","author":"J Sobocinski","year":"2012","unstructured":"Sobocinski, J. et al. Off-the-shelf fenestrated endografts: a realistic option for more than 70% of patients with juxtarenal aneurysms. J. Endovasc Ther. 19, 165\u2013172 (2012).","journal-title":"J. Endovasc Ther."},{"key":"23485_CR18","doi-asserted-by":"publisher","first-page":"559","DOI":"10.1016\/j.ejvs.2021.02.010","volume":"61","author":"BME Mees","year":"2021","unstructured":"Mees, B. M. E. Off the shelf fenestrated stent grafts: Mind the gap? Eur. J. Vasc Endovasc Surg. 61, 559 (2021).","journal-title":"Eur. J. Vasc Endovasc Surg."},{"key":"23485_CR19","doi-asserted-by":"publisher","first-page":"579","DOI":"10.1016\/j.jvs.2014.03.258","volume":"60","author":"MA Farber","year":"2014","unstructured":"Farber, M. A., Vallabhaneni, R. & Marston, W. A. Off-the-shelf devices for complex aortic aneurysm repair. J. Vasc Surg. 60, 579\u2013584 (2014).","journal-title":"J. Vasc Surg."},{"key":"23485_CR20","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1016\/j.jvs.2014.09.068","volume":"61","author":"TM Mastracci","year":"2015","unstructured":"Mastracci, T. M., Eagleton, M. J., Kuramochi, Y., Bathurst, S. & Wolski, K. Twelve-year results of fenestrated endografts for juxtarenal and group IV thoracoabdominal aneurysms. J. Vasc Surg. 61, 355\u2013364 (2015).","journal-title":"J. Vasc Surg."},{"key":"23485_CR21","doi-asserted-by":"publisher","first-page":"1732","DOI":"10.1016\/j.jvs.2021.01.053","volume":"74","author":"M Han","year":"2021","unstructured":"Han, M. et al. Meta-analysis of outcomes after intentional coverage of Celiac artery in thoracic endovascular aortic repair. J. Vasc Surg. 74, 1732\u20131739e1733 (2021).","journal-title":"J. Vasc Surg."},{"key":"23485_CR22","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1016\/j.jvs.2013.04.003","volume":"58","author":"J Jim","year":"2013","unstructured":"Jim, J., Caputo, F. J. & Sanchez, L. A. Intentional coverage of the Celiac artery during thoracic endovascular aortic repair. J. Vasc Surg. 58, 270\u2013275 (2013).","journal-title":"J. Vasc Surg."},{"key":"23485_CR23","doi-asserted-by":"publisher","first-page":"1153","DOI":"10.1016\/j.jvs.2010.06.105","volume":"52","author":"M Mehta","year":"2010","unstructured":"Mehta, M. et al. Outcomes of planned Celiac artery coverage during TEVAR. J. Vasc Surg. 52, 1153\u20131158 (2010).","journal-title":"J. Vasc Surg."},{"key":"23485_CR24","doi-asserted-by":"publisher","first-page":"417","DOI":"10.1016\/j.ejvs.2023.11.005","volume":"67","author":"HP Zhang","year":"2024","unstructured":"Zhang, H. P., Ge, Y. Y., Wang, J. B., Fan, T. T. & Guo, W. Off the shelf multibranched endograft for Thoraco-Abdominal and pararenal abdominal aortic aneurysms: a prospective, single centre study of the G-branch endograft. Eur. J. Vasc Endovasc Surg. 67, 417\u2013425 (2024).","journal-title":"Eur. J. Vasc Endovasc Surg."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-23485-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-23485-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-23485-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T12:59:44Z","timestamp":1781614784000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-23485-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,13]]},"references-count":24,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["23485"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-23485-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,13]]},"assertion":[{"value":"19 December 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 October 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"39818"}}