{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,19]],"date-time":"2025-11-19T11:55:28Z","timestamp":1763553328426,"version":"3.45.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,11,19]],"date-time":"2025-11-19T00:00:00Z","timestamp":1763510400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,11,19]],"date-time":"2025-11-19T00:00:00Z","timestamp":1763510400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/100007816","name":"Alcon","doi-asserted-by":"publisher","award":["IIT#67562399"],"award-info":[{"award-number":["IIT#67562399"]}],"id":[{"id":"10.13039\/100007816","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-025-23939-3","type":"journal-article","created":{"date-parts":[[2025,11,19]],"date-time":"2025-11-19T11:54:04Z","timestamp":1763553244000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Assessment of vivity with French clinical data related to the toric model study"],"prefix":"10.1038","volume":"15","author":[{"given":"Edouard","family":"Koch","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marion","family":"Morel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nathalie","family":"Duchateau","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,11,19]]},"reference":[{"key":"23939_CR1","doi-asserted-by":"publisher","first-page":"507","DOI":"10.3928\/1081597X-20180530-02","volume":"34","author":"B Cochener","year":"2018","unstructured":"Cochener, B., Boutillier, G., Lamard, M. & Auberger-Zagnoli, C. A comparative evaluation of a new generation of diffractive trifocal and extended depth of focus intraocular lenses. J. Refract. Surg. 34, 507\u2013514 (2018).","journal-title":"J. Refract. Surg."},{"key":"23939_CR2","doi-asserted-by":"publisher","first-page":"5","DOI":"10.21037\/aes.2019.01.01","volume":"4","author":"G Kondylis","year":"2019","unstructured":"Kondylis, G., Klavdianou, O. & Palioura, S. Multifocal and extended depth of focus intraocular lenses. Annals Eye Sci. 4, 5\u20135 (2019).","journal-title":"Annals Eye Sci."},{"key":"23939_CR3","doi-asserted-by":"publisher","first-page":"273","DOI":"10.3928\/1081597X-20180214-01","volume":"34","author":"X Liu","year":"2018","unstructured":"Liu, X., Xie, L. & Huang, Y. Comparison of the visual performance after implantation of bifocal and trifocal intraocular lenses having an identical platform. J. Refract. Surg. 34, 273\u2013280 (2018).","journal-title":"J. Refract. Surg."},{"key":"23939_CR4","first-page":"CD003169","volume":"12","author":"SR de Silva","year":"2016","unstructured":"de Silva, S. R., Evans, J. R., Kirthi, V., Ziaei, M. & Leyland, M. Multifocal versus monofocal intraocular lenses after cataract extraction. Cochrane Database Syst. Rev. 12, CD003169 (2016).","journal-title":"Cochrane Database Syst. Rev."},{"key":"23939_CR5","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/j.survophthal.2005.11.003","volume":"51","author":"B Wang","year":"2006","unstructured":"Wang, B. & Ciuffreda, K. J. Depth-of-focus of the human eye: theory and clinical implications. Surv. Ophthalmol. 51, 75\u201385 (2006).","journal-title":"Surv. Ophthalmol."},{"key":"23939_CR6","doi-asserted-by":"publisher","first-page":"194","DOI":"10.1097\/APO.0000000000000296","volume":"9","author":"P Kanclerz","year":"2020","unstructured":"Kanclerz, P., Toto, F., Grzybowski, A. & Alio, J. L. Extended Depth-of-Field intraocular lenses: an update. Asia Pac. J. Ophthalmol. (Phila). 9, 194\u2013202 (2020).","journal-title":"Asia Pac. J. Ophthalmol. (Phila)"},{"key":"23939_CR7","doi-asserted-by":"publisher","first-page":"2717","DOI":"10.1007\/s00417-021-05245-6","volume":"259","author":"A Arrigo","year":"2021","unstructured":"Arrigo, A. et al. Extended depth-of-focus (EDOF) AcrySof\u00ae IQ Vivity\u00ae intraocular lens implant: a real-life experience. Graefes Arch. Clin. Exp. Ophthalmol. 259, 2717\u20132722 (2021).","journal-title":"Graefes Arch. Clin. Exp. Ophthalmol."},{"key":"23939_CR8","doi-asserted-by":"publisher","first-page":"1297","DOI":"10.1097\/j.jcrs.0000000000000978","volume":"48","author":"C McCabe","year":"2022","unstructured":"McCabe, C. et al. Clinical outcomes in a U.S. Registration study of a new EDOF intraocular lens with a nondiffractive design. J. Cataract Refract. Surg. 48, 1297\u20131304 (2022).","journal-title":"J. Cataract Refract. Surg."},{"key":"23939_CR9","doi-asserted-by":"publisher","first-page":"14832","DOI":"10.1038\/s41598-020-69318-y","volume":"10","author":"DW Paik","year":"2020","unstructured":"Paik, D. W., Park, J. S., Yang, C. M., Lim, D. H. & Chung, T-Y. Comparing the visual outcome, visual quality, and satisfaction among three types of multi-focal intraocular lenses. Sci. Rep. 10, 14832 (2020).","journal-title":"Sci. Rep."},{"key":"23939_CR10","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1016\/S0886-3350(13)80824-3","volume":"17","author":"HV Gimbel","year":"1991","unstructured":"Gimbel, H. V. Divide and conquer nucleofractis phacoemulsification: development and variations. J. Cataract Refract. Surg. 17, 281\u2013291 (1991).","journal-title":"J. Cataract Refract. Surg."},{"key":"23939_CR11","doi-asserted-by":"publisher","first-page":"524","DOI":"10.1016\/S0886-3350(13)80617-7","volume":"19","author":"NA Alpins","year":"1993","unstructured":"Alpins, N. A. A new method of analyzing vectors for changes in astigmatism. J. Cataract Refract. Surg. 19, 524\u2013533 (1993).","journal-title":"J. Cataract Refract. Surg."},{"key":"23939_CR12","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1186\/s12886-018-0920-1","volume":"18","author":"M Gauvin","year":"2018","unstructured":"Gauvin, M. & Wallerstein, A. AstigMATIC: an automatic tool for standard astigmatism vector analysis. BMC Ophthalmol. 18, 255 (2018).","journal-title":"BMC Ophthalmol."},{"key":"23939_CR13","doi-asserted-by":"publisher","first-page":"5537","DOI":"10.1167\/iovs.10-5341","volume":"51","author":"C McAlinden","year":"2010","unstructured":"McAlinden, C., Pesudovs, K. & Moore, J. E. The development of an instrument to measure quality of vision: the quality of vision (QoV) questionnaire. Invest. Ophthalmol. Vis. Sci. 51, 5537\u20135545 (2010).","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"23939_CR14","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1016\/j.ajo.2021.10.023","volume":"237","author":"K Lasch","year":"2022","unstructured":"Lasch, K. et al. Development and validation of a visual Symptom-Specific Patient-Reported outcomes instrument for adults with cataract intraocular lens implants. Am. J. Ophthalmol. 237, 91\u2013103 (2022).","journal-title":"Am. J. Ophthalmol."},{"key":"23939_CR15","unstructured":"US FDA. AcrySof\u2122 IQ Vivity\u2122 extended vision Intraocular Lens (IOL): Summary of safety and effectiveness data.\u00a0https:\/\/www.accessdata.fda.gov\/cdrh_docs\/pdf\/P930014S126B.pdf (2021)."},{"key":"23939_CR16","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1097\/j.jcrs.0000000000000712","volume":"48","author":"C Bala","year":"2022","unstructured":"Bala, C. et al. Multicountry clinical outcomes of a new nondiffractive presbyopia-correcting IOL. J. Cataract Refract. Surg. 48, 136\u2013143 (2022).","journal-title":"J. Cataract Refract. Surg."},{"key":"23939_CR17","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1097\/j.jcrs.0000000000000826","volume":"48","author":"T Kohnen","year":"2022","unstructured":"Kohnen, T. et al. Nondiffractive wavefront-shaping extended depth-of-focus intraocular lens: visual performance and patient-reported outcomes. J. Cataract Refract. Surg. 48, 144\u2013150 (2022).","journal-title":"J. Cataract Refract. Surg."},{"key":"23939_CR18","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1016\/j.jcjo.2023.05.010","volume":"59","author":"MTD Nguyen","year":"2024","unstructured":"Nguyen, M. T. D., Yuan, P. H. S., Bachour, K., Sierra, M. C. A. & Durr, G. M. Visual outcomes and rotational stability of a new non-diffractive extended-vision toric intraocular lens. Can. J. Ophthalmol. 59, 234\u2013240 (2024).","journal-title":"Can. J. Ophthalmol."},{"key":"23939_CR19","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1186\/s40662-024-00380-7","volume":"11","author":"F Pastor-Pascual","year":"2024","unstructured":"Pastor-Pascual, F. et al. Non-diffractive, toric, extended depth-of-focus intraocular lenses in eyes with low corneal astigmatism. Eye Vis. (Lond). 11, 14 (2024).","journal-title":"Eye Vis. (Lond)"},{"key":"23939_CR20","doi-asserted-by":"publisher","first-page":"2737","DOI":"10.1007\/s10792-023-02673-7","volume":"43","author":"KM Barber","year":"2023","unstructured":"Barber, K. M., O\u2019Connor, S., Mackinder, P., Chih, A. & Jones, B. Rotational stability and refractive outcomes of the DFT\/DATx15 toric, extended depth of focus intraocular lens. Int. Ophthalmol. 43, 2737\u20132747 (2023).","journal-title":"Int. Ophthalmol."},{"key":"23939_CR21","first-page":"327","volume":"111","author":"W Lubi\u0144ski","year":"2009","unstructured":"Lubi\u0144ski, W., Gronkowska-Serafin, J., Podboraczy\u0144ska-Jodko, K. & Karczewicz, D. Cataract surgery with bilateral multifocal rezoom intraocular lens implantation\u2013comparison of 3 and 12 month follow-up. Klin. Oczna. 111, 327\u2013331 (2009).","journal-title":"Klin. Oczna"},{"key":"23939_CR22","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1016\/j.ajo.2020.07.019","volume":"220","author":"D Schartm\u00fcller","year":"2020","unstructured":"Schartm\u00fcller, D. et al. Comparison of Long-Term rotational stability of three commonly implanted intraocular lenses. Am. J. Ophthalmol. 220, 72\u201381 (2020).","journal-title":"Am. J. Ophthalmol."},{"key":"23939_CR23","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.mjafi.2020.03.014","volume":"78","author":"A Singh","year":"2022","unstructured":"Singh, A., Kapoor, G., Baranwal, V. K. & Kalra, N. Rotational stability of toric intraocular lenses. Med. J. Armed Forces India. 78, 68\u201373 (2022).","journal-title":"Med. J. Armed Forces India"},{"key":"23939_CR24","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1001\/archopht.1960.01840010504005","volume":"64","author":"E Wolf","year":"1960","unstructured":"Wolf, E. Glare and age. Arch. Ophthalmol. 64, 502\u2013514 (1960).","journal-title":"Arch. Ophthalmol."},{"key":"23939_CR25","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1097\/j.jcrs.0000000000000364","volume":"47","author":"T Kohnen","year":"2021","unstructured":"Kohnen, T. & Suryakumar, R. Measures of visual disturbance in patients receiving extended depth-of-focus or trifocal intraocular lenses. J. Cataract Refract. Surg. 47, 245\u2013255 (2021).","journal-title":"J. Cataract Refract. Surg."},{"key":"23939_CR26","doi-asserted-by":"publisher","first-page":"168","DOI":"10.3928\/1081597X-20220104-01","volume":"38","author":"L Fern\u00e1ndez-Vega-Cueto","year":"2022","unstructured":"Fern\u00e1ndez-Vega-Cueto, L. et al. Optical and clinical outcomes of an extended range of vision intraocular lens. J. Refract. Surg. 38, 168\u2013176 (2022).","journal-title":"J. Refract. Surg."},{"key":"23939_CR27","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1186\/s40662-024-00424-y","volume":"12","author":"G Savini","year":"2025","unstructured":"Savini, G. et al. Influence of preoperative variables on the 3-month functional outcomes of the vivity extended depth-of-focus intraocular lens: a prospective case series. Eye Vis. (Lond). 12, 8 (2025).","journal-title":"Eye Vis. (Lond)"}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-23939-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-23939-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-23939-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,19]],"date-time":"2025-11-19T11:54:05Z","timestamp":1763553245000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-23939-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,19]]},"references-count":27,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["23939"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-23939-3","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,19]]},"assertion":[{"value":"29 May 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 October 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Dr Edouard Koch reports being a consultant for Alcon Healthcare.Dr Nathalie Duchateau and Marion Morel declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"UIVA: uncorrected distance intermediate visual acuity, DCIVA: corrected distance intermediate visual acuity; * statistically significant differences (\n                      p\n                      \u2009<\u20090.05).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"This study followed the tenets of the Decalaration of Helsinki and was approved by the Ethics Committee of the of the H\u00f4tel-Dieu Hospital in Paris (ID-RCB No: 2022-A00089-34, NCT: 05416177).\n                      \n                      . Registered 01 september 2022. All recruited patients received a written information letter prior to enrollment. This study has been registered in the European Clinical Trials Register (EUdraCT: 2022-A00089-34).","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}}],"article-number":"40691"}}