{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,3]],"date-time":"2026-11-03T10:28:46Z","timestamp":1793701726129,"version":"4.5.1"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T00:00:00Z","timestamp":1761609600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T00:00:00Z","timestamp":1761609600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"DOI":"10.1038\/s41598-025-24748-4","type":"journal-article","created":{"date-parts":[[2025,10,28]],"date-time":"2025-10-28T09:10:06Z","timestamp":1761642606000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Deep learning-assisted CBCT segmentation provides reliable volumetric assessment of mandibular defects compared with micro-CT for 3D printing and surgical planning"],"prefix":"10.1038","volume":"15","author":[{"given":"Mohsen","family":"Shalalvand","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sina","family":"Haghanifar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ehsan","family":"Moudi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Bijani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,10,28]]},"reference":[{"issue":"5","key":"24748_CR1","doi-asserted-by":"publisher","first-page":"e580","DOI":"10.4317\/medoral.20633","volume":"20","author":"MZ Adisen","year":"2015","unstructured":"Adisen, M. Z. et al. Evaluation of volumetric measurements on CBCT images using Stafne bone cavities as an example. Med. Oral Patol. Oral Cir. Bucal. 20 (5), e580\u2013e586 (2015).","journal-title":"Med. Oral Patol. Oral Cir. Bucal"},{"issue":"7","key":"24748_CR2","doi-asserted-by":"publisher","first-page":"1468","DOI":"10.1002\/jbmr.141","volume":"25","author":"ML Bouxsein","year":"2010","unstructured":"Bouxsein, M. L. et al. Guidelines for assessment of bone microstructure in rodents using micro\u2013computed tomography. J. Bone Miner. Res. 25 (7), 1468\u20131486 (2010).","journal-title":"J. Bone Miner. Res."},{"issue":"4","key":"24748_CR3","doi-asserted-by":"publisher","first-page":"399","DOI":"10.5624\/isd.20220102","volume":"52","author":"JAC Travessas","year":"2022","unstructured":"Travessas, J. A. C. et al. Validation and comparison of volume measurements using 1 multidetector computed tomography and 5 cone-beam computed tomography protocols: an in vitro study. Imaging Sci. Dent. 52 (4), 399\u2013408 (2022).","journal-title":"Imaging Sci. Dent."},{"key":"24748_CR4","unstructured":"Mallya, S. & Lam, E. White and Pharoah\u2019s Oral Radiology: Principles and Interpretation (Elsevier Health Sciences, 2018)."},{"issue":"29","key":"24748_CR5","doi-asserted-by":"publisher","first-page":"2302442","DOI":"10.1002\/adfm.202302442","volume":"33","author":"YP Zou","year":"2023","unstructured":"Zou, Y. P. et al. Precipitation-based silk fibroin fast gelling, highly adhesive, and magnetic nanocomposite hydrogel for repair of irregular bone defects. Adv. Funct. Mater. 33 (29), 2302442 (2023).","journal-title":"Adv. Funct. Mater."},{"issue":"1","key":"24748_CR6","doi-asserted-by":"publisher","first-page":"e41049","DOI":"10.2196\/41049","volume":"12","author":"C Fonseca","year":"2023","unstructured":"Fonseca, C., Cavadas, F. & Fonseca, P. Upper airway assessment in cone-beam computed tomography for screening of obstructive sleep apnea syndrome: development of an evaluation protocol in dentistry. JMIR Res. Protocols. 12 (1), e41049 (2023).","journal-title":"JMIR Res. Protocols"},{"issue":"3","key":"24748_CR7","doi-asserted-by":"publisher","first-page":"180","DOI":"10.4274\/TurkJOrthod.2022.2022.12","volume":"36","author":"YA \u00dcn\u00fcvar","year":"2023","unstructured":"\u00dcn\u00fcvar, Y. A. & K\u00f6se, E. Evaluation of maxillary sinus volume of class III individuals with different jaw positions by Cone-Beam computed tomography. Turkish J. Orthod. 36 (3), 180 (2023).","journal-title":"Turkish J. Orthod."},{"issue":"12","key":"24748_CR8","doi-asserted-by":"publisher","first-page":"1450","DOI":"10.1111\/clr.12488","volume":"26","author":"MN Favato","year":"2015","unstructured":"Favato, M. N. et al. Impact of human maxillary sinus volume on grafts dimensional changes used in maxillary sinus augmentation: a multislice tomographic study. Clin. Oral. Implants. Res. 26 (12), 1450\u20131455 (2015).","journal-title":"Clin. Oral. Implants. Res."},{"issue":"8","key":"24748_CR9","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1038\/s41578-020-0204-2","volume":"5","author":"GL Koons","year":"2020","unstructured":"Koons, G. L., Diba, M. & Mikos, A. G. Materials design for bone-tissue engineering. Nat. Reviews Mater. 5 (8), 584\u2013603 (2020).","journal-title":"Nat. Reviews Mater."},{"issue":"10","key":"24748_CR10","doi-asserted-by":"publisher","first-page":"301","DOI":"10.3390\/jfb15100301","volume":"15","author":"C Weismann","year":"2024","unstructured":"Weismann, C. et al. Complete digital workflow for manufacturing presurgical orthodontic palatal plates in newborns and infants with cleft lip and\/or palate. J. Funct. Biomaterials. 15 (10), 301 (2024).","journal-title":"J. Funct. Biomaterials"},{"issue":"15","key":"24748_CR11","doi-asserted-by":"publisher","first-page":"4103","DOI":"10.3390\/ma14154103","volume":"14","author":"M Aretxabaleta","year":"2021","unstructured":"Aretxabaleta, M. et al. Accuracy evaluation of additively and subtractively fabricated palatal plate orthodontic appliances for newborns and infants\u2013an in vitro study. Materials 14 (15), 4103 (2021).","journal-title":"Materials"},{"issue":"1","key":"24748_CR12","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.ijom.2022.05.013","volume":"52","author":"R Steegman","year":"2023","unstructured":"Steegman, R. et al. Cone beam computed tomography volumetric airway changes after orthognathic surgery: a systematic review. Int. J. Oral Maxillofac. Surg. 52 (1), 60\u201371 (2023).","journal-title":"Int. J. Oral Maxillofac. Surg."},{"issue":"1","key":"24748_CR13","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1186\/s40001-025-02366-0","volume":"30","author":"X Zheng","year":"2025","unstructured":"Zheng, X. et al. To evaluate the clinical efficacy of decompression for large cystic lesions in mandible by digital technology. Eur. J. Med. Res. 30 (1), 104 (2025).","journal-title":"Eur. J. Med. Res."},{"key":"24748_CR14","doi-asserted-by":"publisher","first-page":"204173141877090","DOI":"10.1177\/2041731418770909","volume":"9","author":"A Aldaadaa","year":"2018","unstructured":"Aldaadaa, A., Owji, N. & Knowles, J. Three-dimensional printing in maxillofacial surgery: hype versus reality. J. Tissue Eng. 9, 2041731418770909 (2018).","journal-title":"J. Tissue Eng."},{"issue":"1","key":"24748_CR15","doi-asserted-by":"publisher","first-page":"66","DOI":"10.4103\/ijdr.IJDR_415_16","volume":"28","author":"S Patrick","year":"2017","unstructured":"Patrick, S. et al. Comparison of Gray values of cone-beam computed tomography with Hounsfield units of multislice computed tomography: an in vitro study. Indian J. Dent. Res. 28 (1), 66\u201370 (2017).","journal-title":"Indian J. Dent. Res."},{"issue":"8","key":"24748_CR16","doi-asserted-by":"publisher","first-page":"20200145","DOI":"10.1259\/dmfr.20200145","volume":"49","author":"H Ga\u00eata-Araujo","year":"2020","unstructured":"Ga\u00eata-Araujo, H. et al. Cone beam computed tomography in dentomaxillofacial radiology: a two-decade overview. Dentomaxillofacial Radiol. 49 (8), 20200145 (2020).","journal-title":"Dentomaxillofacial Radiol."},{"issue":"5","key":"24748_CR17","first-page":"282","volume":"14","author":"M Panjnoush","year":"2017","unstructured":"Panjnoush, M., Kheirandish, Y. & Zeini, N. Effect of Spatial position in the field of view on dimensional changes in cone beam computed tomography. J. Dentistry (Tehran Iran). 14 (5), 282 (2017).","journal-title":"J. Dentistry (Tehran Iran)"},{"issue":"4","key":"24748_CR18","doi-asserted-by":"publisher","first-page":"e25272","DOI":"10.5812\/iranjradiol.25272","volume":"12","author":"S Valizadeh","year":"2015","unstructured":"Valizadeh, S. et al. Effect of object position in cone beam computed tomography field of view for detection of root fractures in teeth with intra-canal posts. Iran. J. Radiol. 12 (4), e25272 (2015).","journal-title":"Iran. J. Radiol."},{"issue":"1","key":"24748_CR19","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1186\/s12903-021-01595-z","volume":"21","author":"N Ibrahim","year":"2021","unstructured":"Ibrahim, N. et al. Comparison of anterior and posterior trabecular bone microstructure of human mandible using cone-beam CT and micro CT. BMC Oral Health. 21 (1), 249 (2021).","journal-title":"BMC Oral Health"},{"issue":"10","key":"24748_CR20","doi-asserted-by":"publisher","first-page":"1021","DOI":"10.1016\/j.bjoms.2015.09.030","volume":"53","author":"C Rostetter","year":"2015","unstructured":"Rostetter, C. et al. Comparison of in vivo cone-beam and multidetector computed tomographic scans by three-dimensional merging software. Br. J. Oral Maxillofac. Surg. 53 (10), 1021\u20131026 (2015).","journal-title":"Br. J. Oral Maxillofac. Surg."},{"issue":"8","key":"24748_CR21","doi-asserted-by":"publisher","first-page":"20170325","DOI":"10.1259\/dmfr.20170325","volume":"47","author":"G S\u00f6nmez","year":"2018","unstructured":"S\u00f6nmez, G., Ko\u00e7, C. & Kamburo\u011flu, K. Accuracy of linear and volumetric measurements of artificial ERR cavities by using CBCT images obtained at 4 different voxel sizes and measured by using 4 different software: an ex vivo research. Dentomaxillofac Radiol. 47 (8), 20170325 (2018).","journal-title":"Dentomaxillofac Radiol."},{"issue":"1","key":"24748_CR22","doi-asserted-by":"publisher","first-page":"8324","DOI":"10.1038\/s41598-025-93250-8","volume":"15","author":"S Shetty","year":"2025","unstructured":"Shetty, S. et al. Accuracy of deep learning models in the detection of accessory ostium in coronal cone beam computed tomographic images. Sci. Rep. 15 (1), 8324 (2025).","journal-title":"Sci. Rep."},{"key":"24748_CR23","doi-asserted-by":"publisher","first-page":"105130","DOI":"10.1016\/j.jdent.2024.105130","volume":"147","author":"G Dot","year":"2024","unstructured":"Dot, G. et al. DentalSegmentator: robust open source deep learning-based CT and CBCT image segmentation. J. Dent. 147, 105130 (2024).","journal-title":"J. Dent."},{"issue":"4","key":"24748_CR24","doi-asserted-by":"publisher","first-page":"2816","DOI":"10.21037\/qims-23-1617","volume":"14","author":"S Wang","year":"2024","unstructured":"Wang, S. et al. Fully automated deep learning system for osteoporosis screening using chest computed tomography images. Quant. Imaging Med. Surg. 14 (4), 2816\u20132827 (2024).","journal-title":"Quant. Imaging Med. Surg."},{"issue":"12","key":"24748_CR25","doi-asserted-by":"publisher","first-page":"e0000191","DOI":"10.1371\/journal.pdig.0000191","volume":"2","author":"C Macfadyen","year":"2023","unstructured":"Macfadyen, C., Duraiswamy, A. & Harris-Birtill, D. Classification of hyper-scale multimodal imaging datasets. PLOS Digit. Health. 2 (12), e0000191 (2023).","journal-title":"PLOS Digit. Health"},{"issue":"1","key":"24748_CR26","doi-asserted-by":"publisher","first-page":"20140204","DOI":"10.1259\/dmfr.20140204","volume":"44","author":"D Br\u00fcllmann","year":"2015","unstructured":"Br\u00fcllmann, D. & Schulze, R. Spatial resolution in CBCT machines for dental\/maxillofacial applications\u2014what do we know today? Dentomaxillofacial Radiol. 44 (1), 20140204 (2015).","journal-title":"Dentomaxillofacial Radiol."},{"issue":"4","key":"24748_CR27","doi-asserted-by":"publisher","first-page":"334","DOI":"10.4103\/jisp.jisp_675_18","volume":"23","author":"E Moudi","year":"2019","unstructured":"Moudi, E. et al. Evaluation of the cone-beam computed tomography accuracy in measuring soft tissue thickness in different areas of the jaws. J. Indian Soc. Periodontology. 23 (4), 334\u2013338 (2019).","journal-title":"J. Indian Soc. Periodontology"},{"issue":"2","key":"24748_CR28","doi-asserted-by":"publisher","first-page":"133","DOI":"10.5624\/isd.20210274","volume":"52","author":"A Selvaraj","year":"2022","unstructured":"Selvaraj, A. et al. Correlation between Gray values of cone-beam computed tomograms and Hounsfield units of computed tomograms: A systematic review and meta-analysis. Imaging Sci. Dentistry. 52 (2), 133 (2022).","journal-title":"Imaging Sci. Dentistry"},{"issue":"6","key":"24748_CR29","doi-asserted-by":"publisher","first-page":"20140001","DOI":"10.1259\/dmfr.20140001","volume":"43","author":"LB Petersen","year":"2014","unstructured":"Petersen, L. B. et al. Image and surgery-related costs comparing cone beam CT and panoramic imaging before removal of impacted mandibular third molars. Dentomaxillofacial Radiol. 43 (6), 20140001 (2014).","journal-title":"Dentomaxillofacial Radiol."},{"issue":"1","key":"24748_CR30","doi-asserted-by":"publisher","first-page":"1472","DOI":"10.1186\/s12903-024-05259-6","volume":"24","author":"M Ozdede","year":"2024","unstructured":"Ozdede, M. et al. Repeatability and effect of different voxel sizes on linear and volumetric tooth and pulp measurements using cone-beam computed tomography. BMC Oral Health. 24 (1), 1472 (2024).","journal-title":"BMC Oral Health"},{"issue":"3","key":"24748_CR31","doi-asserted-by":"publisher","first-page":"20200400","DOI":"10.1259\/dmfr.20200400","volume":"50","author":"A Ko\u00e7","year":"2021","unstructured":"Ko\u00e7, A. & Kaya, S. Is it possible to estimate volume of bone defects formed on dry sheep mandibles more practically by secondarily reconstructing section thickness of cone beam computed tomography images? Dentomaxillofac Radiol. 50 (3), 20200400 (2021).","journal-title":"Dentomaxillofac Radiol."},{"issue":"3","key":"24748_CR32","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.jot.2015.05.002","volume":"3","author":"Y Li","year":"2015","unstructured":"Li, Y. et al. Bone defect animal models for testing efficacy of bone substitute biomaterials. J. Orthop. Translat. 3 (3), 95\u2013104 (2015).","journal-title":"J. Orthop. Translat"},{"key":"24748_CR33","doi-asserted-by":"crossref","unstructured":"Krull, A., Buchholz, T. O. & Jug, F. Noise2void-learning denoising from single noisy images. in Proceedings of the IEEE\/CVF Conference on computer vision and pattern recognition. (2019).","DOI":"10.1109\/CVPR.2019.00223"},{"issue":"10","key":"24748_CR34","doi-asserted-by":"publisher","first-page":"983","DOI":"10.1038\/nmeth.4405","volume":"14","author":"M Chen","year":"2017","unstructured":"Chen, M. et al. Convolutional neural networks for automated annotation of cellular cryo-electron tomograms. Nat. Methods. 14 (10), 983\u2013985 (2017).","journal-title":"Nat. Methods"},{"key":"24748_CR35","doi-asserted-by":"publisher","first-page":"2235","DOI":"10.1007\/s00784-018-2665-x","volume":"23","author":"MA Tayman","year":"2019","unstructured":"Tayman, M. A. et al. Comparison of linear and volumetric measurements obtained from periodontal defects by using cone beam-CT and micro-CT: an in vitro study. Clin. Oral Invest. 23, 2235\u20132244 (2019).","journal-title":"Clin. Oral Invest."},{"issue":"6","key":"24748_CR36","doi-asserted-by":"publisher","first-page":"538","DOI":"10.1111\/iej.12023","volume":"46","author":"M Ahlowalia","year":"2013","unstructured":"Ahlowalia, M. et al. Accuracy of CBCT for volumetric measurement of simulated periapical lesions. Int. Endod. J. 46 (6), 538\u2013546 (2013).","journal-title":"Int. Endod. J."},{"issue":"10","key":"24748_CR37","doi-asserted-by":"publisher","first-page":"959","DOI":"10.1111\/iej.12390","volume":"48","author":"P Da Silveira","year":"2015","unstructured":"Da Silveira, P. et al. CBCT-based volume of simulated root resorption\u2013influence of FOV and voxel size. Int. Endod. J. 48 (10), 959\u2013965 (2015).","journal-title":"Int. Endod. J."},{"issue":"8","key":"24748_CR38","doi-asserted-by":"publisher","first-page":"1091","DOI":"10.4103\/njcp.njcp_678_18","volume":"22","author":"F Yilmaz","year":"2019","unstructured":"Yilmaz, F. et al. Accuracy of CBCT images in the volumetric assessment of residual root Canal filling material: effect of voxel size. Niger J. Clin. Pract. 22 (8), 1091\u20131098 (2019).","journal-title":"Niger J. Clin. Pract."},{"issue":"2","key":"24748_CR39","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1007\/s11282-023-00731-5","volume":"40","author":"YM El-Beblawy","year":"2024","unstructured":"El-Beblawy, Y. M., Bakry, A. M. & Mohamed, M. E. A. Accuracy of formula-based volume and image segmentation-based volume in calculation of preoperative cystic jaw lesions\u2019 volume. Oral Radiol. 40 (2), 259\u2013268 (2024).","journal-title":"Oral Radiol."},{"issue":"3","key":"24748_CR40","doi-asserted-by":"publisher","first-page":"165","DOI":"10.5624\/isd.2017.47.3.165","volume":"47","author":"CW Park","year":"2017","unstructured":"Park, C. W. et al. Volumetric accuracy of cone-beam computed tomography. Imaging Sci. Dent. 47 (3), 165\u2013174 (2017).","journal-title":"Imaging Sci. Dent."},{"issue":"2","key":"24748_CR41","doi-asserted-by":"publisher","first-page":"93","DOI":"10.5624\/isd.20200320","volume":"51","author":"BR Terrabuio","year":"2021","unstructured":"Terrabuio, B. R. et al. Cone-beam computed tomography artifacts in the presence of dental implants and associated factors: an integrative review. Imaging Sci. Dentistry. 51 (2), 93 (2021).","journal-title":"Imaging Sci. Dentistry"},{"issue":"1","key":"24748_CR42","doi-asserted-by":"publisher","first-page":"14902","DOI":"10.1038\/s41598-020-71651-1","volume":"10","author":"JY Shi","year":"2020","unstructured":"Shi, J. Y. et al. Accuracy assessment of a novel semiautomatic method evaluating bone grafts around the dental implant: an in vitro and ex vivo study. Sci. Rep. 10 (1), 14902 (2020).","journal-title":"Sci. Rep."},{"issue":"3","key":"24748_CR43","doi-asserted-by":"publisher","first-page":"1995","DOI":"10.1109\/JBHI.2024.3505262","volume":"29","author":"J Xu","year":"2025","unstructured":"Xu, J. et al. Automatic segmentation of bone graft in maxillary sinus via distance constrained network guided by prior anatomical knowledge. IEEE J. Biomed. Health Inf. 29 (3), 1995\u20132005 (2025).","journal-title":"IEEE J. Biomed. Health Inf."},{"issue":"5","key":"24748_CR44","doi-asserted-by":"publisher","first-page":"921","DOI":"10.3390\/diagnostics13050921","volume":"13","author":"T Kamio","year":"2023","unstructured":"Kamio, T. & Kawai, T. CBCT images to an STL model: exploring the critical factors to binarization thresholds in STL data creation. Diagnostics 13 (5), 921 (2023).","journal-title":"Diagnostics"},{"issue":"8","key":"24748_CR45","doi-asserted-by":"publisher","first-page":"20230187","DOI":"10.1259\/dmfr.20230187","volume":"52","author":"A Yadegari","year":"2023","unstructured":"Yadegari, A. et al. Assessment of CBCT Gray value in different regions-of-interest and fields-of-view compared to Hounsfield unit. Dentomaxillofacial Radiol. 52 (8), 20230187 (2023).","journal-title":"Dentomaxillofacial Radiol."},{"issue":"6","key":"24748_CR46","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1093\/dmfr\/twae026","volume":"53","author":"J Koivisto","year":"2024","unstructured":"Koivisto, J. et al. Assessment of cone-beam CT technical image quality indicators and radiation dose for optimal STL model used in visual surgical planning. Dentomaxillofacial Radiol. 53 (6), 423\u2013433 (2024).","journal-title":"Dentomaxillofacial Radiol."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-24748-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-24748-4","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-24748-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T21:02:39Z","timestamp":1762030959000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-24748-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,10,28]]},"references-count":46,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["24748"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-24748-4","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,10,28]]},"assertion":[{"value":"16 April 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 October 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 October 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"All stages of the study were conducted after obtaining approval from the Ethics Committee of Babol University of Medical Sciences (approval code: IR.MUBABOL.AEC.1403.015).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}}],"article-number":"37561"}}