{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T10:57:03Z","timestamp":1784285823482,"version":"3.55.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,11,25]],"date-time":"2025-11-25T00:00:00Z","timestamp":1764028800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,11,25]],"date-time":"2025-11-25T00:00:00Z","timestamp":1764028800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Kyoto University in the Translational Research Program from AMED","award":["JP23ym0126808"],"award-info":[{"award-number":["JP23ym0126808"]}]},{"name":"Kyoto University in the Translational Research Program from AMED","award":["JP23ym0126808"],"award-info":[{"award-number":["JP23ym0126808"]}]},{"name":"JST SPRING","award":["JPMJSP2101"],"award-info":[{"award-number":["JPMJSP2101"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Sci Rep"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Understanding object information during robotic hand grasping is a key goal in robotics. Researchers have integrated tactile sensors to replicate artificial haptics on humanoid robot fingertips, but robotic grasping has yet to be fully applied in palpation-based medical diagnosis. Current techniques, such as vibration-based ultrasound-assisted surgeries, face limitations in diagnosis due to anatomical constraints or surgical access issues. To address this, we explored palpation-assisted surgeries using a microfinger, a miniaturized version of a human finger. We developed micromachine-based palpation techniques for advanced minimally invasive diagnosis using endoscopes. Specifically, we developed a microfinger with artificial muscle and tactile sensors, designed to detect stiffness singularities in pseudo-biological tissues. Our microfinger, thin and small, exerted a pushing force greater than 1 N and performed directional palpation. Next, we proposed an algorithm for estimating three-dimensional coordinates, thus transcending the existing two-dimensional singularity-estimation method. Consequently, we achieved touch sensing on silicone gel blocks using a small rigid ball, with depth-estimation of approximately\u2009\u00b1\u20091.3\u00a0mm at a depth of 15\u00a0mm. The directivity of the microfinger enabled three-dimensional positional estimation of the singular point. We present a breakthrough for microfinger-based palpation technology for medical diagnosis, accelerating the advancement of robotics-based palpation-driven minimally invasive techniques.<\/jats:p>","DOI":"10.1038\/s41598-025-25774-y","type":"journal-article","created":{"date-parts":[[2025,11,25]],"date-time":"2025-11-25T14:53:48Z","timestamp":1764082428000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Depth-estimation of stiffness singularity in an elastic object via directional touch sensing using microfinger with tactile sensor"],"prefix":"10.1038","volume":"15","author":[{"given":"Y.","family":"Hori","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Konishi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,11,25]]},"reference":[{"key":"25774_CR1","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/S1367-5788(01)00011-6","volume":"25","author":"HG Stassen","year":"2001","unstructured":"Stassen, H. G., Dankelman, J., Grimbergen, K. A. & Meijer, D. W. Man-machine aspects of minimally invasive surgery. Annu. Rev. Control 25, 111\u2013122 (2001).","journal-title":"Annu. Rev. Control"},{"key":"25774_CR2","doi-asserted-by":"publisher","first-page":"1534","DOI":"10.2214\/AJR.07.3123","volume":"190","author":"SK Venkatesh","year":"2008","unstructured":"Venkatesh, S. K. et al. MR elastography of liver tumors: preliminary results. AJR Am. J. Roentgenol. 190, 1534\u20131540 (2008).","journal-title":"AJR Am. J. Roentgenol."},{"key":"25774_CR3","doi-asserted-by":"publisher","first-page":"1253","DOI":"10.1002\/bjs.4716","volume":"91","author":"M Van der Voort","year":"2004","unstructured":"Van der Voort, M., Heijnsdijk, E. A. M. & Gouma, D. J. Bowel injury as a complication of laparoscopy. Br. J. Surg. 91, 1253\u20131258 (2004).","journal-title":"Br. J. Surg."},{"key":"25774_CR4","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1080\/13645700701820242","volume":"17","author":"EP Westebring-van der Putten","year":"2008","unstructured":"Westebring-van der Putten, E. P., Goossens, R. H., Jakimowicz, J. J. & Dankelman, J. Haptics in minimally invasive surgery\u2014A review. Minim. Invasive Ther. Allied Technol. 17, 3\u201316 (2008).","journal-title":"Minim. Invasive Ther. Allied Technol."},{"key":"25774_CR5","doi-asserted-by":"publisher","first-page":"S425","DOI":"10.1007\/s00464-006-0035-2","volume":"20","author":"JJ Jakimowicz","year":"2006","unstructured":"Jakimowicz, J. J. Intraoperative ultrasonography in open and laparoscopic abdominal surgery: an overview. Surg. Endosc. Other Interv. Tech. 20, S425\u2013S435 (2006).","journal-title":"Surg. Endosc. Other Interv. Tech."},{"key":"25774_CR6","doi-asserted-by":"publisher","first-page":"496","DOI":"10.1016\/j.nanoen.2018.07.001","volume":"51","author":"H Chen","year":"2018","unstructured":"Chen, H. et al. Hybrid porous micro structured finger skin inspired self-powered electronic skin system for pressure sensing and sliding detection. Nano Energy 51, 496\u2013503 (2018).","journal-title":"Nano Energy"},{"key":"25774_CR7","doi-asserted-by":"publisher","first-page":"10446","DOI":"10.1109\/JSEN.2022.3171218","volume":"22","author":"Y Qin","year":"2022","unstructured":"Qin, Y. et al. Dual-mode flexible capacitive sensor for proximity-tactile interface and wireless perception. IEEE Sens. J. 22, 10446\u201310453 (2022).","journal-title":"IEEE Sens. J."},{"key":"25774_CR8","doi-asserted-by":"crossref","unstructured":"Nakai, A. et al. MEMS 6-axis force-torque sensor attached to the tip of grasping forceps for identification of tumor in thoracoscopic surgery. In 2017 IEEE 30th International Conference on Micro Electro Mechanical Systems (MEMS), pp. 546\u2013548 (IEEE, 2017).","DOI":"10.1109\/MEMSYS.2017.7863464"},{"key":"25774_CR9","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1177\/0278364906065826","volume":"25","author":"T Kawahara","year":"2006","unstructured":"Kawahara, T., Tanaka, S. & Kaneko, M. Non-contact stiffness imager. Int. J. Robot. Res. 25, 537\u2013549 (2006).","journal-title":"Int. J. Robot. Res."},{"key":"25774_CR10","doi-asserted-by":"crossref","unstructured":"Talasaz, A. & Patel, R. V. Telerobotic palpation for tumor localization with depth estimation. In 2013 IEEE\/RSJ International Conference on Intelligent Robots and Systems, pp. 463\u2013468 (IEEE, 2013).","DOI":"10.1109\/IROS.2013.6696392"},{"key":"25774_CR11","first-page":"1","volume":"71","author":"Z Zhou","year":"2022","unstructured":"Zhou, Z. et al. Methods to recognize depth of hard inclusions in soft tissue using ordinal classification for robotic palpation. IEEE Trans. Instrum. Meas. 71, 1\u201312 (2022).","journal-title":"IEEE Trans. Instrum. Meas."},{"key":"25774_CR12","doi-asserted-by":"publisher","first-page":"1791","DOI":"10.1109\/TASE.2020.2978881","volume":"17","author":"B Xiao","year":"2020","unstructured":"Xiao, B. et al. Depth estimation of hard inclusions in soft tissue by autonomous robotic palpation using deep recurrent neural network. IEEE Trans. Autom. Sci. Eng. 17, 1791\u20131799 (2020).","journal-title":"IEEE Trans. Autom. Sci. Eng."},{"key":"25774_CR13","doi-asserted-by":"publisher","first-page":"15634","DOI":"10.1038\/s41598-019-52022-x","volume":"9","author":"S Konishi","year":"2019","unstructured":"Konishi, S. & Hirata, A. Flexible temperature sensor integrated with soft pneumatic microactuators for functional microfingers. Sci. Rep. 9, 15634 (2019).","journal-title":"Sci. Rep."},{"key":"25774_CR14","doi-asserted-by":"crossref","unstructured":"Otake, S., Mori, F. & Konishi, S. Common flexible channel structure for integration of three-axis force sensor and soft micro actuator. In 2019 IEEE 32nd International Conference on Micro Electro Mechanical Systems (MEMS), pp. 652\u2013655 (IEEE, 2019).","DOI":"10.1109\/MEMSYS.2019.8870621"},{"key":"25774_CR15","doi-asserted-by":"publisher","first-page":"395","DOI":"10.3390\/mi12040395","volume":"12","author":"S Konishi","year":"2021","unstructured":"Konishi, S., Mori, F., Shimizu, A. & Hirata, A. Structural reinforcement effect of a flexible strain sensor integrated with pneumatic balloon actuators for soft microrobot fingers. Micromachines 12, 395 (2021).","journal-title":"Micromachines"},{"key":"25774_CR16","doi-asserted-by":"publisher","first-page":"16963","DOI":"10.1038\/s41598-022-21188-2","volume":"12","author":"S Konishi","year":"2022","unstructured":"Konishi, S. et al. Active tactile sensing of small insect force by a soft microfinger toward microfinger-insect interactions. Sci. Rep. 12, 16963 (2022).","journal-title":"Sci. Rep."},{"key":"25774_CR17","doi-asserted-by":"publisher","first-page":"21374","DOI":"10.1038\/s41598-022-25847-2","volume":"12","author":"S Konishi","year":"2022","unstructured":"Konishi, S., Kakehi, Y. & Hori, Y. Directional touch sensing for stiffness singularity search in an object using microfinger with tactile sensor. Sci. Rep. 12, 21374 (2022).","journal-title":"Sci. Rep."},{"key":"25774_CR18","doi-asserted-by":"publisher","first-page":"1128","DOI":"10.1002\/tee.70029","volume":"20","author":"Y Hori","year":"2025","unstructured":"Hori, Y. & Konishi, S. Searching for stiffness singularity using directional palpation by a microfinger and its scanning condition dependence. IEEJ Trans. Electr. Electron. Eng. 20, 1128\u20131133 (2025).","journal-title":"IEEJ Trans. Electr. Electron. Eng."},{"key":"25774_CR19","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/S0924-4247(00)00533-1","volume":"89","author":"S Konishi","year":"2001","unstructured":"Konishi, S., Kawai, F. & Cusin, P. Thin flexible end-effector using pneumatic balloon actuator. Sens. Actuators A 89, 28\u201335 (2001).","journal-title":"Sens. Actuators A"},{"key":"25774_CR20","unstructured":"Jeong, O. C., Kusuda, S. & Konishi, S. All PDMS pneumatic balloon actuators for bidirectional motion of micro finger. In 18th IEEE International Conference on Micro Electro Mechanical Systems, 2005. MEMS 2005, pp. 407\u2013410 (IEEE, 2005)."},{"key":"25774_CR21","doi-asserted-by":"publisher","first-page":"12038","DOI":"10.1038\/s41598-020-68458-5","volume":"10","author":"S Konishi","year":"2020","unstructured":"Konishi, S. & Kosawa, H. High-output bending motion of a soft inflatable microactuator with an actuation conversion mechanism. Sci. Rep. 10, 12038 (2020).","journal-title":"Sci. Rep."},{"key":"25774_CR22","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1038\/s41378-023-00526-y","volume":"9","author":"Y Hori","year":"2023","unstructured":"Hori, Y. & Konishi, S. Design improvement of the conversion mechanism from balloon inflation to bending motion for inflatable film actuators. Microsyst. Nanoeng. 9, 55 (2023).","journal-title":"Microsyst. Nanoeng."},{"key":"25774_CR23","doi-asserted-by":"publisher","first-page":"867","DOI":"10.1002\/tee.24008","volume":"19","author":"Y Hori","year":"2024","unstructured":"Hori, Y., Suzuki, S., Katsura, T. & Konishi, S. High efficiency actuation conversion mechanism for high-output bending motion of a soft inflatable microactuator. IEEJ Trans. Electr. Electron. Eng. 19, 867\u2013871 (2024).","journal-title":"IEEJ Trans. Electr. Electron. Eng."}],"container-title":["Scientific Reports"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-25774-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-25774-y","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-25774-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,25]],"date-time":"2025-11-25T14:53:50Z","timestamp":1764082430000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.nature.com\/articles\/s41598-025-25774-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,11,25]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["25774"],"URL":"https:\/\/doi.org\/10.1038\/s41598-025-25774-y","relation":{},"ISSN":["2045-2322"],"issn-type":[{"value":"2045-2322","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,11,25]]},"assertion":[{"value":"23 June 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 October 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 November 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"41852"}}